All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Chieftronic GPU-1050FC
General Data-
Manufacturer (OEM)CWT
PCB TypeDouble Sided
Primary Side-
Transient Filter6x Y caps, 2x X caps, 2x CM chokes, 1x MOV
Inrush ProtectionNTC Thermistor (SCK-085) & Relay
Bridge Rectifier(s)2xGBJ2506P (600V, 25A @ 100°C)
APFC MOSFETs2x ISCTK25A60X5(600V, 25A @ 25°C, 0.14Ohm), 1x Sync PowerSPN5003FET (for reduced no-load consumption)
APFC Boost Diode2x ON Semiconductor FFSP0665A (650V, 6A @ 153°C)
Hold-up Cap(s)2x Nichicon (400V, 680uF & 560uF each or 1,240uF combined, 2,000h @ 105°C, GG)
Main Switchers4x (550V, 15A @ 100°C, 0.14Ohm)
IC Drivers2xSilicon LabsSi8233BD
Digital Controllers2x Texas InstrumentsUCD3138A
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency89.659%
Efficiency With 10W (≤500W) or 2% (>500W)60.492
Average Efficiency 5VSB77.124%
Standby Power Consumption (W)0.0431377
Average PF0.993
Avg Noise Output35.06 dB(A)
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-S+
230V
Average Efficiency91.473%
Average Efficiency 5VSB77.010%
Standby Power Consumption (W)0.0769939
Average PF0.939
Avg Noise Output35.19 dB(A)
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-S+
Chieftronic GPU-1050FC
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)19.7
AC Loss to PWR_OK Hold Up Time (ms)18.5
PWR_OK Inactive to DC Loss Delay (ms)1.2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Chieftronic GPU-1050FC
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 4/15
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Chieftronic GPU-1050FC
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.225
69.018%
4.992V0.326115.16V
0.090A0.449
73.486%
4.991V0.611115.16V
0.550A2.742
78.075%
4.984V3.512115.16V
1.000A4.977
77.283%
4.976V6.440115.16V
1.500A7.453
77.185%
4.968V9.656115.15V
3.001A14.824
76.570%
4.940V19.360115.15V
0.027
0.050
0.236
0.342
0.405
0.483
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.225
61.813%
4.995V0.364230.19V
0.090A0.449
69.183%
4.993V0.649230.22V
0.550A2.741
76.671%
4.984V3.575230.20V
1.000A4.977
77.247%
4.976V6.443230.20V
1.500A7.453
77.321%
4.968V9.639230.20V
3.001A14.826
77.303%
4.941V19.179230.20V
0.009
0.016
0.085
0.145
0.202
0.315
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/15
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ 11 hidden pages