Chief XFD1U Installation Guide

Page 1
I N S T A L L A T I O N I N S T R U C T I O N S
Instrucciones de instalación Installationsanleitung Instruções de Instalação
Istruzioni di installazione Installatie-instructies Instructions d´installation
Spanish Product Description German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
XFD1U
Page 2
XFD1U Installation Instructions
DISCLAIMER
Legrand | AV and its affiliated corporations and subsidiaries (collectively “Legrand | AV”), intend to make this manual accurate and complete. However, Legrand | AV makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Legrand | AV makes no representation of warranty, expressed or implied, regarding the information contained herein. Legrand | AV assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.
DEFINITIONS
WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the corresponding instructions.
DANGER alerts you to an imminently
hazardous situation which, if not avoided, will result in death or serious injury.
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting system such as a video camera, CPU, screen, display, projector, etc.
DANGER: TO REDUCE THE RISK OF
ELECTRIC SHOCK:
1. Always turn off power at source before cleaning.
WARNING: TO REDUCE THE RISK OF
BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
1. Unplug from outlet before putting on or taking off parts.
2. Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
3. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
4. Never operate this mounting system if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the mounting system to a service center for examination and repair.
5. Keep the cord away from heated surfaces.
6. Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, and the like.
7. Never drop or insert any object into any opening.
8. Do not use outdoors.
9. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
10. To disconnect, turn all controls to the off position, then remove plug from outlet.
WARNING: Failure to provide adequate
structural strength for this mounting system can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this mounting system is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the mounting system.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: FAILURE TO READ AND FOLLOW
THE FOLLOWING INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY, DAMAGE TO EQUIPMENT OR VOIDING OF FACTORY WARRANTY. It is the installer’s responsibility to make sure all components are properly assembled and installed using the instructions provided.
When using an electrical mounting system, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT!!!!
2
WARNING: Exceeding the weight capacity
can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the weight of all components attached to the XFD1U does not exceed 310 lbs (140.6 kg).
WARNING: Use this mounting system only
for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
WARNING: Never operate this mounting
system if it is damaged. Return the mounting system to a service center for examination and repair.
Page 3
Installation Instructions XFD1U
IMPORTANT ! : The XFD1U is designed to be mounted to:
a bare concrete wall with a minimum thickness of 8" (203mm):
a bare 8" x 8" x 16" (203mm x 203mm x 406mm) concrete block wall; or
wood studs spaced 16" on center with a maximum drywall covering of 5/8”.
a 2" x 4"-25ga minimum steel stud wall.
a bare drywall wall with a minimum thickness of 1/2" (12.7mm).
NOTE: The XFD1U stand has no user serviceable parts.
NOTE: The XFD1U stand can support screen sizes up to a
maximum of 100" wide.
NOTE: The XFD1U stand is intended for Institutional Use.
NOTE: To reduce the risk of electric shock, this furnishing has
a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
NOTE: This product is a double-insulated, cord-connected
product and must be serviced accordingly. In a double­insulated product, two systems of insulation are provided instead of grounding. No grounding means for grounding to be added to the product Servicing a double-insulated product requires extreme care and knowledge of the system, and is to be done only by qualified service personnel. Replacement parts for a double-insulated product must be identical to the parts they replace. A double-insulated product is marked
with the symbol (square within a square)
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Changes or modifications to this
unit not expressly approved by the manufacturer can void the units FCC compliance rating and make the unit illegal to operate.
Responsible Party:
Legrand | AV 6436 City West Parkway Eden Prairie, MN 55344 866-977-3901 av.support@legrand.com
CAN ICES-3 (B)/NMB-3(B)
--SAVE THESE INSTRUCTIONS--
Electrical Specifications
Input voltage, frequency
Duty Cycle
100-240 V~, 50-60 Hz, 450W
Intermittent: 10%; max 2 minutes on/18 minutes off
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
3
Page 4
XFD1U Installation Instructions
21.95
DIMENSIONS
557.6
ACCESSORY MOUNTING PATTERN 3.93 [100mm]
61.55
1563.4
20.37
517.5
MAX
16.00
406.3
MIN 7.94 [201.6]
MAX33.94 [862]
35.96
913.4
26.50
673.1
WEIGHT RATING : 310 lbs. (140 kg)
ELECTRICAL RATI NG:
100-240 VAC, 50-60HZ, 450W
Int. 10 %, Max. 2 min/18min.
6.90 MIN
7.06
MAX
179.2
1.01
25.6
7.00
177.8
4
Page 5
Installation Instructions XFD1U
LEGEND
Tighten Fastener
Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme
Pencil Mark
Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon
Drill Hole
Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou
Adjust
Ajustar Einstellen Ajustar Regolare Afstellen Ajuster
Open-Ended Wrench
Llave de boca Gabelschlüssel Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche
By Hand
A mano Von Hand Com a mão A mano Met de hand À la main
Hex-Head Wrench
Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale
Remove
Quitar Entfernen Remover Rimuovere Verwijderen Retirez
Optional
Opcional Optional Opcional Opzionale Optie En option
Security Wrench
Llave de seguridad Sicherheitsschlüssel Chave de segurança Chiave di sicurezza Veiligheidssleutel Clé de sécurité
5
Page 6
XFD1U Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
7/32" (5.3mm) - wood studs 3/8" (10mm) - concrete/drywall
1/2" (12.7mm) - steel studs
1/2" (deep)
PARTS
1/8” (included)
3/16” (included)
A (1)
[Strap with buckle]
B (1)
#10-24
+ installation instructions
C (1)
#10
#2
D (1)
[Column assembly]
Q (1) - Display interface + hardware
(See interface parts list on page 7)
G (1)
[Power cable]
M (2)
#10-24 x 3/8"
R (1)
[Double-sided foam tape]
N (1) [Hardware bag]
N1 (4)
5/16 x 2 1/2"
H (4)
[Cable clip]
N2 (4)
Ux10x60mm
E (8)
[Cable tie]
J (2)
[Large spacer]
N3 (4)
[5/16" slotted washer]
(not used)
F (1)
[Component bracket]
K (1)
P (1) [Steel stud hardware bag]
P1 (4)
1/4-20 x 2 1/2"
3/16”
P2 (4)
1/4"
[1/4-20 toggle anchor]
L (1)
1/8”
P3 (4)
6
Page 7
Installation Instructions XFD1U
Hardware Kit
PARTS - DISPLAY INTERFACE
QR (2) [Vertical bracket]
Bag A
QA (4)
M4 x 12mm
Bag D
QD (4) M5 x 12mm
Bag G
QG (4) M6 x 12mm M6 x 20mm
Bag J
QJ (4) M8 x 12mm
Bag M
QMA (8)
[Nesting spacer]
Bag B
QB (4) M4 x 20mm
Bag E
QE (4) M5 x 20mm
Bag H
QH (4)
Bag K
QK (4) M8 x 20mm
Bag C
QC (4) M4 x 25mm
Bag F
QF (4) M5 x 25mm
Bag I
QI (4)
M6 x 25mm
Bag L
QL (4) M8 x 30mm
QMB (4)
[Universal spacer]
QQ (2) [Horizontal bracket]
QN (8)
#10-24 x 1/2"
QP (1) 1/8”
7
Page 8
XFD1U Installation Instructions
Assembly And Installation
Stand Assembly/Setup
IMPORTANT ! : The XFD1U packaging was designed to
help make the installation and setup easier. Do NOT remove assembly prior to reading installation instructions!
1. Remove all parts and extra packaging from sides of box leaving only the column assembly (D) in the box. (See Figure 1)
2. Lift column assembly (D) up using the two finger tabs at the bottom of the assembly. (See Figure 1)
3. Carefully set column assembly (D) base on the edge of box. (See Figure 1) and (See Figure 2)
(D)
remove parts and packaging
control pad bracket
control pad
5
Figure 3
1
2
2
3
1
3
Figure 1
4. Remove stand from box by tipping it from the top onto its base. (See Figure 2)
4
6. Remove bottom two screws from back cover. (See Figure 4)
7. Loosen top two screws from back cover. (See Figure 4)
8. Remove back cover by lifting cover up and out. (See Figure
4)
8
7
loosen x 2
Figure 2
5. Secure control pad into control pad bracket. (See Figure 3)
NOTE: Control pad may be relocated to under display if control
pad cable is removed from side channel and re-routed through main channel. Proceed to "Control Pad
Relocation" Section.
8
Figure 4
6
x 2
Page 9
Installation Instructions XFD1U
9. Plug in power cable (G) to power supply. Provide strain
relief using the cable tie (E) on nearest cable clip. (See Figure 5)
9
(G)
Figure 5
10. (Optional) Place component bracket (F) in mounting
position. (See Figure 6)
11. (Optional) Use two #10-24 x 3/8" button head cap screws
(M) to secure component bracket. (See Figure 6)
NOTE: Strap with buckle (A) and/or cable ties (E) may be used
to secure components to component bracket (F).
NOTE: If lifting mechanism does not function properly refer to
"Troubleshooting" Section.
"UP"
"DOWN"
"PRESETS"
"SAVE"
Figure 7
14. Remove bottom two screws from front cover. (See Figure 8)
15. Use finger tabs to pull front cover out and slide down. Cover must be flexed to remove pins from uprights in order to remove. (See Figure 8)
(F)
10
11
(M) x 2
Figure 6
12. Press and hold "DOWN" button for three seconds to initialize lift mechanism. (See Figure 7)
13. Press and hold "UP" button until mount reaches it’s maximum height. (See Figure 7)
14
15
x 2
Figure 8
9
Page 10
XFD1U Installation Instructions
16. Attach display and signal cables to power source. Use cable clips (H) and cable ties (E) to route as necessary. (See Figure 9)
IMPORTANT ! : Make sure to install cables when lift is at the highest position and so that there is enough length to reach input locations for display and signal.
enough distance to
reach inputs
16
recommended strain relief
(pre-installed cable clips)
locations
17. (Optional) Relocate control pad to the front center of display if desired following these steps. (See Figure 10)
A. Unplug control box cable from control box.
B. Remove cable through side cable cover.
C. Pull cable out through opening at bottom of
cable cover.
D. Feed removed cable down through center
channel.
E. Plug cable back into control box.
F. Use double-sided foam tape (R) to attach
control pad to bottom of display in the center.
B
signal cable to signal box
(example)
power cable
(example)
F
D
A
C
additional cable tie locations
if extra cable clips (H) are used
recommended strain relief
locations
(pre-installed cable clips)
10
additional cable tie locations
if extra cable clips (H) are used
Figure 9
E
recommended strain relief
locations
(pre-installed cable clips)
Figure 10
Page 11
Installation Instructions XFD1U
18. Reinstall front cover by using two screws removed in Step
14. (See Figure 11)
18
18
x 2
Figure 11
19. Reinstall rear cover and secure by installing screws removed in Step 6. (See Figure 12)
20. Tighten screws that were loosened in Step 7. (See Figure
12)
19
20
tighten x 2
19
x 2
Figure 12
21. Lower mount to its lowest position and move it to desired mounting location.
11
Page 12
XFD1U Installation Instructions
Attachment to Wall
The XFD1U is designed to be mounted to:
a bare concrete wall with a minimum thickness of 8" (203mm):
a bare 8" x 8" x 16" (203mm x 203mm x 406mm) concrete block wall; or
wood studs spaced 16" on center with a maximum drywall covering of 5/8”.
a 2" x 4"-25ga minimum steel stud wall.
a bare drywall wall with a minimum thickness of 1/2" (12.7mm).
NOTE: Space can be created behind the mount (on any
substrate) by using large spacers (J) or nesting spacers included with PSBU behind installation tabs during installation. Large spacers (J) will provide 0.75" while two nesting spacers will provide 0.375".
Installing to Wood Stud Wall
1. Use a stud-finder to locate 16" studs.
2. Place column assembly against wall making sure to line up attachment brackets with studs. (See Figure 13)
3. Mark hole locations at each mounting location. (See Figure
13)
4. Drill two 7/32” holes at marked hole locations. (See Figure
13)
4
3
5
(N1) x 2
7/32” (5.3mm)
Installing to a Concrete Wall
1. Place column assembly against wall at desired mounting location. (See Figure 14)
2. Mark hole locations at each mounting location. (See Figure
14)
3. Drill two 3/8” holes at marked hole locations. (See Figure
14)
4. Install an anchor (N2) into each pilot hole using a hammer, making sure that the anchor is flush with the wall. (See Figure 14)
2
3
5
5. Install two 5/16 x 2 1/2” hex head cap screws (N1) through holes on attachment brackets and into anchors (N2) on wall. (See Figure 14)
(N1) x 2
Figure 14
3/8"
4
(N2) x 2
Figure 13
5. Install two 5/16 x 2 1/2” hex head cap screws (N1) through holes on attachment brackets and into drilled holes on wall. (See Figure 13)
Installing to Steel Studs/Drywall
NOTE: The installation procedure is the same for installing to
steel studs and drywall only except that a pilot hole does not need to be drilled if installing to drywall only.
12
Page 13
Installation Instructions XFD1U
Site Requirements (Steel Studs)
16" (on center) Studs
XFD1U Installation Location
(Must be centered over two studs)
If back side of wall is unfinished, drywall must be installed to a minimum of one stud left and right of the studs being used to install the mount. Drywall must be secured to studs with screws 12" on center
Drywall
**1/2" minimum
Drywall Thickness
(Both Sides of Stud)
**See hazard statement
on page 2!
There must be a minimum of
FRONT
Steel Stud (2 x 4 / 25ga minimum) Stud type and structural strength must conform to the North American Specification for the Design of Cold-Formed Steel Structural Members.
[362, 125 18, C-Shape, S - Stud Section]
1-7/8" (48mm) clearance inside wall
13
Page 14
XFD1U Installation Instructions
1. Drill a 1/2" hole at the desired mounting locations.
2. Hold metal channel on anchor (P3) flat alongside plastic straps and slide channel through hole. (See Figure 15)
Drywall Plastic Straps
(P3)
2
Figure 15
3. Holding plastic straps on anchor (P3), pull anchor away from wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud. (See Figure
16)
4. Slide plastic cap on anchor (P3) towards wall until flange of cap is flush with wall. (See Figure 16)
Steel Stud
Drywall
WARNING: IMPROPER INSTALLATION CAN LEAD TO
EQUIPMENT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT! Overtightening of mounting hardware can damage the steel studs. DO NOT overtighten mounting hardware!
8. Insert two 1/4-20 x 2 1/4" hex head tapping bolts (P1) through two 1/4" washers (P2), corresponding mounting holes on mount and into anchors (P3) and tighten until flush against mount. DO NOT overtighten! (See Figure 18)
(P2) x 2
Steel Studs
8
(P1) x 2
Figure 18
Plastic Cap
4
3
(P3)
Anchor Metal Channel
SIDE VIEW
Figure 16
5. Snap off plastic straps on anchor at wall by pushing side to side, snapping off straps level with flange of plastic cap. (See Figure 17)
6. Repeat Steps 1 through 5 for the other mounting hole.
Steel Stud
Drywall
5
Plastic Cap
Display Installation
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all accessories and components attached to the XFD1U head assembly up to (and including) the display does not exceed 310 lbs (140.6 kg).
1. Make sure height is at the lowest possible position.
2. Make sure latching flags are in "open" position.
WARNING: IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT! DO NOT substitute hardware. Only use hardware provided or specified by manufacturer.
Plastic Straps
Anchor Metal Channel
SIDE VIEW
Figure 17
7. Place mount over anchors and align mounting holes on mount with holes in anchors. (See Figure 18)
14
Page 15
Installation Instructions XFD1U
3. Determine and mark the vertical center position between
the Left side Upper and Lower mounting holes in display. (See Figure 19)
4. Determine and mark the vertical center position between
the Right side Upper and Lower mounting holes in display. (See Figure 19)
(QR) x 2
Mounting holes
3
6
Mounting Slots
7. Adjust vertical mounting bracket (QR) position until mark made in Step 1 aligns with center mark in vertical mounting bracket (QR).
8. Select correct screws, nesting spacers (if necessary) and universal washers (if required) from the hardware bag (QA­QM) and attach brackets to back of screen. (See Figure 21)
IMPORTANT ! : The M8 screws do NOT require a washer. Use the universal washer (QMB) only with M4, M5 and M6 screws.
NOTE: The nesting spacers (QMA) may be used separately,
or put two together in different configurations to create different size spacers. (See Figure 20)
(Single) (Nested) (Stacked)
0.375
[9.5]
0.563 [14.3]
0.750 [19.1]
Figure 20
9. If the display has a recessed mounting surface, protrusions or a power box, a spacer and longer mounting hardware must be placed between the display and vertical mounting bracket (QR). (See Figure 21)
10. Repeat Steps 5 through 8 for Right side vertical mounting bracket using the same hole locations to align brackets horizontally.
Figure 19
5. Orient vertical mounting bracket (QR) so that mounting holes are on top and mounting slots are on bottom. (See Figure 19)
6. Align mounting holes in vertical mounting bracket (QR) with upper and lower mounting holes in display.
10
8
(QR) x 2
(QMA) x 4
(QMB) x 4
(QR)
(QA through QL)
x 4
Figure 21
15
Page 16
XFD1U Installation Instructions
11. Determine and mark the horizontal center position between the Left and Right TOP mounting holes in display. (See Figure 22)
12. Determine and mark the horizontal center position between the Left and Right BOTTOM mounting holes in display. (See Figure 22)
13. Orient upper horizontal mounting bracket (QQ) so that flanges are facing towards display and resting in recessed area of left and right vertical mounting brackets (QR). (See Figure 22)
14. Adjust Upper horizontal mounting bracket (QQ) position until center diamond in horizontal mounting bracket (QU) aligns with mark made in Step 9, and mounting holes and slots in horizontal mounting bracket (QQ) are aligned with threaded holes in mounting tabs of left and right vertical mounting brackets (QR). (See Figure 22) and (See Figure
23)
15. Use 1/8" hex key (QP) to secure upper horizontal mounting bracket (QQ) to left and right vertical mounting brackets (QR) using four button head flanged screws (QN). (See Figure 23)
16. Repeat Steps 12 through 15 for lower horizontal mounting bracket (QQ).
IMPORTANT ! : The orientation of, and mounting holes used,
when installing the lower horizontal mounting bracket must be the same as the upper horizontal mounting bracket. Vertically align upper and lower brackets by aligning holes or end of slots. (See Figure 23)
IMPORTANT ! : Whenever possible install mounting screws diagonally as shown in detail in Figure 23 below.
17. Install display with attached universal interface to mount following the installation instructions provided with the mount.
11
(QQ) x 2
(QR) x 2
Figure 22
12
Center Mark
(QR) x 2
15
(QR) x 2
15
14
(QN) x 8
(QQ) x 2
Figure 23
16
Page 17
Installation Instructions XFD1U
18. Make sure latching flags are in "closed" position prior to
using cart!
IMPORTANT ! : Manufacturer recommends using cable ties (Z) to secure the latching flags in closed position on both sides if padlock is not being used. (See Figure 24)
(Z) x 2
Figure 24
Adjustments
Height Adjustment
1. Press "UP" or "DOWN" buttons to raise or lower height as
desired. (See Figure 25)
"UP"
"DOWN"
"PRESETS"
Figure 25
Save Height Levels
1. Adjust height until desired preset level is reached using
"UP" and "DOWN" buttons. (See Figure 25)
2. Press "SAVE" button. (See Figure 25)
3. Press one of three preset buttons (., .. or ...) to save preset
position. (See Figure 25)
4. Repeat Steps 1-3 as desired.
"SAVE"
Troubleshooting
If lifting function does not work properly, try to following troubleshooting steps. If none of these work, contact customer service.
1. If there is uneven movement, initialize the control box
2. If there is no movement, check the following
3. If there is slight movement and then reverse travel, check
4. Contact customer service if none of the above steps fix the
Using Remote and Dongle
Refer to installation instructions included with remote (B) and dongle (C) to set up remote system.
lower
raise
Figure 26
(reset)
Hold "Down" button until lift has reached it’s lower limit.
Briefly release "Down" button
Press and hold "Down" for five seconds, wait until all movement has stopped, then release
Check all cable connectors between controllers and actuators.
Check power cable connection to control box.
for any obstructions that may be interfering such as cables or peripheral devices.
problem.
Leveling Adjustment
1. Use 3/16" hex key to adjust leveling adjustment screws on top of stand. (See Figure 26)
Turn Counterclockwise to lower
Turn Clockwise to raise
17
Page 18
XFD1U Installation Instructions
18
Page 19
Installation Instructions XFD1U
19
Page 20
XFD1U Installation Instructions
8800-003012 Rev06 2019 Legrand | AV
www.legrandav.com
03/19
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000 F 877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P +31 (0) 495 580 852 F +31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099 F 852 2145 4477
Loading...