Mouse 3 or 5 buttons with 1 hot key, 1 link switch, 1 channel switch (Option) and 1 DC
jack (Option)
Receiver 1 link button
3.6 Mechanical Performance
3.6.1 Operating force of mouse buttons: 60 ± 20gf
3.6.2 Operating force of side buttons on mouse: 60 ± 20gf
3.6.3 Operating force of browser switch: 200 ± 40gf
3.6.4 Operating torque of wheel scrolling: 50 ± 30gf.cm
3.6.5 Operating force of mo vable: 20 ± 10gf
3.6.6 Mouse Weight: 140 ± 25g (with Batteries)
3.6.7 Receiver Weight: 70 ± 20g (with Cable)
4.Electrical Specification:
4.1 Compatibility
The PS/2 mode shall be compatible with IBM PC/XT/AT/386/486/PENTIUM and works with
operating system such as DOS, Windows 95/98/2000/ME/XP , and NT as well as the most
software applications.
The USB mode is using the low speed interface defined in the USB specification.
It’s compliant to the USB specification as well as to the HID class specification REV 1.1.
The USB mode shall be compatible with IBM PC/PENTIUM and works with operating system
such as Windows 98/2000/ME/XP as well as the most software applications.
4.2 USB/PS2 Mode Changeable
Combo mode included USB and PS/2 operation modes, using the adapter to change the either
one mode on the receiver.
4.3 Technical on Mouse
Optical sensor for X/Y axis, the precise sensor detects motion on hundreds of surfaces, including
wood, plastic, and even your pants leg. Scroll wheel uses a mechanical encoder.
4.4 Sensor Report Rate on Mouse
1500 times per second
4.5 Sensor Light on Mouse
Red LED
4.6 Mouse Resolution
Tel:886‑2‑82265111(Rep.),Fax:886‑2‑82265222,
The mouse shall have a resolution of 800 ± 50 counts per inch of motion as measured by
counting state transitions at the processor-input pins.
4.7.2 USB Mode
Voltage range: 4.4V to 5.25VDC
Operating current: 30mA (max.)
Consumption in suspend mode (generic) less than 0.5mA in average value
Data transfer rate: 1.5MHz
Maximal polling rate: every 10ms (limit for low speed device on USB)
4.8 Cable
The length and color of the cable on receiver are defined by ID.
4.9 Operation Angle
The mouse operation angle is 360 degrees.
4.10 Operation Distance
The RF mouse operation distance is more than 1 meter (mous e to receiver set).
4.11 Channel Changeable (for Dual Channels)
The channels are changed by slide switch on mouse.
The IDs are changed by link button on mouse and receiver.
4.13 Battery
4.13.1 Battery Type: AA * 2
4.13.2 Battery Consumption: Mouse will be on sleep mode, while non-used after 10 minutes.
Mouse works again, need to push any button on it.
Operation mode 100mA (max.)
Stand-by mode 10mA (max.)
Sleep mode 0.20mA (max.)
4.13.3 Battery Low Indicator: when the battery voltage is less than 2.3V, the indicator on the
rubber wheel should be light while moving the mouse.
4.14 Tracking Speed
The unit shall be capable of tracking between 50mm/s and 254mm/s of hand movement on the
matt white paper without loss of data.
4.15 Charging
Tel:886‑2‑82265111(Rep.),Fax:886‑2‑82265222,
Must use 2pcs of the AAA type rechargeable battery in battery compartment. While 1’st using,
should charge 6~8hrs at least. The charge LED on the mouse will be light steadily in charging
mode.
4.15.1 Power from Adapter: AC to DC adapter plugs in the mouse.
4.15.1.1 Input: 120V/AC 60Hz
Output: 6V/DC 300mA
4.15.1.2 Input: 230V/AC 50Hz
Output: 6V/DC 300mA
4.15.2 Power from USB Charger: Connect USB port of PC and mouse by USB Charger.
4.16 Data Transmission for Mouse
The indicator for data transmission is green LED on the receiver. While moving the mouse or
changing the ID number, the LED will be flash. Otherwise, the indicator lights steadily.
5.Software:
Buttons Definition (Default):
Button Left (1) Right (2) Wheel (3) S-Left (4) S-Right (5) Hot Key
Individual units must pass any and all of the following tests. The order of testing is subject to the
tester. Passing the test is defined as functioning properly without significant damage; including but
not limited to mechanical failure, electrical failure, chips or cracks in the housing or significant
changes in the tactile feel.
6.1 Mean Time Between Failure (MTBF)
The unit shall have an expected MTBF under operating conditions of not less than 150,000
hours (on condition 6 hours per day operation, 250 days per year with 99% confidence level).
6.2 Button Switch Activation
The unit shall survive a minimum of 1,000,000 times (for all of the micro switches on mouse).
Tested at 1.5 cycles per second.
6.3 Scroll Rotation
The unit shall be rotated a minimum of 100,000 cycles at a speed of 10 cycles per minute at least
without electrical load after which measurement shall be made.
6.4 Tracking Life
Tel:886‑2‑82265111(Rep.),Fax:886‑2‑82265222,
The unit shall survive a minimum of 100km at a speed of 10cm per second.
6.5 Drop Shock with Bare Unit
Drop the unit from 76cm height onto a concrete floor, on the top, bottom and 3 sides without
cable side of the unit (1 time for each side). The unit should be without damage. Damage is
defined as failure of the unit to function properly, chips in the housing, or mechanical failure of
any of the parts.
6.6 Drop Shock in Gift Box
Drop the unit in box from 91cm o nto a concrete floor, on the 4 corners and 6 sides of the box (1
time for each side). Resulting damage should be minimal and shall not allow for contents to
escape from packaging.
6.7 Drop Shock in Carton
Unit shall survive a drop test in the weight of product carton on 1 corner, 3 edges and 6 sides
from the height onto a concrete floor (1 time for each side).
</= 9.5kg------91cm
</= 18.6kg------76.2cm
</= 27.6kg------61cm
</= 45.3kg------45.7cm
6.8 High Temperature Test for Operating Pattern
The unit is kept at the temperature of 0 to 40 degrees Celsius and relative humidity of 0% to
95% for 250 hours and then left at ambient room temperature for 1 hour.
-40 degrees Celsius to 65 degrees Celsius under 0% to 90% relative humidity with total time of
40 hours, and then left at ambient room temperature for 2 hours.
6.10 Cable Bending Strength
The cable must withstand bending 60 degrees any direction from its centerline; the detail testing
conditions as followed:
Load: 100 grams force
Angle: +/-60 degrees around 25.4mm diameter
Speed: 30 cycles/min
Criteria: Min 5,000 cycles, with no visible damage and no breakage in each wire.
6.11 Vibration
Unit shall survive a vibration within a frequency range of oscillation: 5~55Hz with amplitude
0.38mm(p-p) for X, Y and Z axis, each 30min.
7.Reliability Performance:
Tel:886‑2‑82265111(Rep.),Fax:886‑2‑82265222,
After having been subjected to any and all of the reliability tests outlined in section 6.0, the unit
shall meet the following performance specifications:
Button Actuation:
25~55 grams force at outer edge of button (minimum force of actuation)
40~80 grams force in the center of the button.
The buttons must be free from both pre-travel and over-travel.
Pre-travel occurs when the button or the keycap is permitted to move before it contacts the switch.
Over-travel occurs when the button or keycap continues to compress the switch after it is completely
depressed.
8.Environmental Standards:
8.1 Operating temperature and humidity
Temperature: 0º C ~ 40º C
Humidity: 0% ~ 85% RH
8.2 Storage temperature and humidity
Temperature: -30º C ~ 60º C
Humidity: 0% ~ 90% RH
9.Safety and Standards:
The mouse is certified to comply with the limits for class B computing device pursuant, to subpart