Chicago Faucet 937-CHLEOAGV User Manual

MECHANICAL FAUCETS 937-CHLEOAGV
Needle Valves
Product Type
___________________________________________________
Panel Mounted Single Needle Valves Needle Valve
Job Name ________________________________________________
Features & Specifications
___________________________________________________
• Single Needle Valves
• 2-1/2" Cross Handle
• Needle Valve Compression Operating Cartridge
• 3/8" - 18 NPT Male Thread Inlet
• May Be Used with Most Laboratory Gases
• 937 Valve is Certified for Gas Service per ANSI Z21.15b-2006/CSA 9.1b-2006 by the Canadian Standards Association
Performance Specification
___________________________________________________
• Rated Operating Pressure: 0-0.5 PSI
Warranty
___________________________________________________
• Lifetime Limited Faucet Warranty
• 5-Year Limited Cartridge Warranty
• 1-Year Limited Finish Warranty
Item Number _____________________________________________
Section/Tag ______________________________________________
Model Specified ___________________________________________
Architect _________________________________________________
Engineer _________________________________________________
Contractor ________________________________________________
[ ] Submitted as Shown [ ] Submitted with Variations
Last Revision: 03/22/2013 • Date Printed: 07/10/2013 • Product specifications subject to change without notice
2100 South Clearwater Drive
Des Plaines, IL P: 847/803-5000 F: 847/803-5454
Technical: 800/TEC-TRUE
www.chicagofaucets.com
937-CHLEOAGV
Needle Valves
Architect/Engineer Specification
________________________________________________________________________________________________________
Chicago Faucets No. 937-CHLEOAGV, Panel Mounted Single Needle Valves Needle Valve, Chrome Plated solid brass construction. 2-1/2" Metal Cross handle(s) with Eight Point Tapered Broach and AIR, GAS or VAC Button. 3/8" - 18 NPT Male Thread Inlet. May Be Used with Most Laboratory Gases. 937 Valve is Certified for Gas Service per ANSI Z21.15b-2006/CSA 9.1b-2006 by the Canadian Standards Association. Mounting hardware included.
Operation and Maintenance
________________________________________________________________________________________________________
Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning the product. Do not use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap and warm water for cleaning and protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair parts documents that are located at www.chicagofaucets.com.
Chicago Faucets, member of the Geberit Group, is the leading brand of commercial faucets and fittings in the United States, offering a complete range of products for schools, laboratories, hospitals, office buildings, food service, airports and sport facilities. Call 1.800.TECTRUE or 1.847.803.5000 Option 1 for installation or other technical assistance.
2100 South Clearwater Drive
Technical: 800/TEC-TRUE
www.chicagofaucets.com
Last Revision: 03/22/2013 • Date Printed: 07/10/2013 • Product specifications subject to change without notice
Des Plaines, IL P: 847/803-5000 F: 847/803-5454