PRODUCT TYPE
Wall mounted single inlet fitting
FEATURES &SPECIFICATIONS
• Polished chrome plated finish
• Solid brass body construction
• 3 1/2" C-C Rigid/Swing field convertable gooseneck
spout, catalog #GN1A
• 2.2 GPM (8.3 L/min) pressure compensating aerator
outlet, catalog #E3
• 1⁄2" NPT female inlet
PERFORMANCE SPECIFICATION
• Rated Operating Pressure: 20-125 PSI
• Rated Operating Temperature: 40-140° F
WARRANTY
• Lifetime Limited Faucet Warranty
• 5-Year Limited Cartridge Warranty
• 1-Year Limited Finish Warranty
COMPLIANT TO
• ASME A112.18.1M • CSA B125
• NSF 61, Sec. 9 • ADA
629-E3CP
Wall Mounted Single lnlet Fitting
9/08
2100 South Clearwater Drive
Des Plaines, IL 60018
P: 847/803-5000
F: 847/803-5454
Technical: 800/TEC-TRUE
www.chicagofaucets.com
U
.
S
.
G
R
E
E
N
B
U
I
L
D
I
N
G
C
O
U
N
C
I
L
M
E
M
B
E
R
Job Name ____________________________________________________
Item Number _________________________________________________
Section/Tag __________________________________________________
Model Specified ______________________________________________
Architect _____________________________________________________
Engineer _____________________________________________________
Contractor ___________________________________________________
❏ Submitted as Shown ❏ Submitted with Variations
Date _________________________________________________________
MANUAL FAUCETS
629-E3CP
Wall Mounted Single Inlet Fitting
ARCHITECT/ENGINEER SPECIFICATION
Chicago Faucets No. 629-E3CP, Polished chrome plated solid brass construction. 3 1/2" C-C rigid/swing field convertible
gooseneck spout. 2.2 GPM pressure compensating aerator outlet. 1/2" NPT female inlet. This product meets ADA requirements
and is tested and certified to industry standards: ASME A112.18.1, NSF 61, Sec. 9 and CSA B125.
10?
" [54mm]
DIA. FLANGE
2-1/8
"
[57mm]
2-1/4
"
[225mm]
8-7/8
"
[89mm]
3-1/2
"
[156mm]
6-1/8
1/2" NPT FEMALE
THREAD INLET
9/08 Product specifications subject to change without notice.
2100 South Clearwater Drive
Des Plaines, IL 60018
P: 847/803-5000
F: 847/803-5454
Technical: 800/TEC-TRUE
www.chicagofaucets.com
C US
®
OPERATION AND MAINTENANCE
Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove
spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning this product. Do not
use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap and warm water for cleaning and
protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair
parts documents that are located at www.chicagofaucets.com
.
Chicago Faucets, member of the Geberit Group, is the leading brand of commercial faucets and fittings in the United States, offering
a complete range of products for schools, laboratories, hospitals, office buildings, food service, airports and sport facilities.
Call 1.800.TECTRUE or 1.847.803.5000 Option 1 for installation or other technical assistance.