Geberit Manufacturing, Inc.
1100 Boone Dr., Michigan City, IN 46360 USA
U.S.: Phone: 219.879.4466 • Toll-free: 800.225.7217 • Fax: 219.872.8003
Canada: Toll-free: 866.748.4646 • Fax: 514.648.8509
www.us.geberit.com
Model 115.845.21.1 - 1.6
Right Hand
Model 115.847.21.1 - 1.6
Left Hand
DC Power Source
1.6 gpf volume flush (6 liters)
Product Specifications
Flushometer valve housing shall be chrome plated
die-cast metal.
Valve shall feature: dual infrared sensors, turbine
metering system, electro-mechanical flush override
button, four “AA” alkaline batteries providing 100,000
cycle life; batteries shall be replaceable without water
source shut-off; low battery indicator integral with
sensor array; range and flush volume adjustments
shall be made without disassembly. Flush volumes
shall be adjustable in 1/10th gallon (0.38 liter) increments without disassembly; valve factory set for 1.6
gpf (6 liter) flush.
Options
Service remote control
Clean remote control
Features
• Patented turbine flow meter water control system
• Adjustable infrared ranging without disassembly
• Range 15˝-42˝ (38.1-106.7 cm) – Factory setting 30˝
(76.2 cm)
• DC power – 4 “AA” alkaline batteries included
• Battery life expectancy – 100,000 cycles
• Stainless steel particulate filter
• Consistent flush regardless of pressure fluctuations
• Minimum operating pressure – 15 PSI (1.0 bar)
• Maximum operating pressure – 100 PSI (7 bar)
• Low battery warning system
• Dual infrared sensor system
• Flush volume adjustable in 1/10th gallon (0.38 liter)
increments
• Adjustable reseal volume for toilet
• Electro-mechanical override flush button
• Complies with ADA requirements
• Clean remote allows unit shut-off for 10 minutes
• Automatically turns itself back on after 10 minutes
if clean remote not activated
• Statistical feedback (with optional service remote)
• Flush tube, vacuum breaker, escutcheons and
attachment hardware included
• Stop valve included
Warranty
• Full three-year limited warranty on solenoid
• Five-year limited warranty on all other mechanicals
Compliance
• ASSE 1037
• ADA compliant
Note:
Pressurized plumbing fixture flushing devices
(flushometers) shall be installed in accordance with
manufacturer’s recommendations. The supply piping
to these devices shall be securely anchored to the
building structure to prevent the installed device from
unnecessary movement when operated by the user.
Care shall be exercised when installing the device to
prevent marring the exposed significant surface.