Chevin A500, A700v User Manual

USER MANUAL
for
PROFESSIONAL POWER AMPLIFIERS:
A500 • A700v • A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 A5000 • A5003 • A6000 • Q6 • Q900 • Q1004 • QB1000/600 • Line250 • Line500
CONTENTS
Installation.................................................. 2
Box contents, positioning & power................ 2
Inputs ........................................................... 3
Outputs ........................................................ 4
Speaker power ratings .................................. 5
Speaker impedances ..................................... 5
Mono bridge mode....................................... 6
Bridge input & output wiring ........................6
Operation ...................................................7
Protection systems ........................................ 7
Servicing.......................................................7
Front & rear panels .......................................8
Specications.............................................. 14
Warranty & mono bridge loadings ..............16
3

Installation

Box contents

In addition to your amplier and this manual, the carton should contain the following items:
Neutrik® Speakon® plugs, depending on your amplier model:
• Line250, Line500 no Speakon plugs
• A700v: one Speakon plug
• Q6, Q1004, QB1000/600, Q900: four Speakon plugs
• All other models: two Speakon plugs
A500 and A700v only. Detachable power cable with IEC connector.
Warranty card. Please complete this card and return it to Chevin Research. Failure to register may result in delays if you require warranty service. See rear cover for warranty.

Positioning

• Your amplier must have good ventilation. Air is drawn in at the rear panel and is expelled at the front. It is vital to keep front and rear of unit free from obstruction.
• Your amplier may be used free-standing or installed in a 19” rack. If installed in a rack, the rear of the chassis should be supported. Rear rack-mount supports are integral on all models except the A500 & A700v.
Power
Wiring
• EARTHING: All Chevin ampliers must be earthed.
• A500 & A700v models connect to the mains supply via a supplied detachable power cable.
• All other models have xed power cables, colour coded to European standards:
Green/Yellow = Earth Blue=Neutral Brown= Live
• The A5000, A6000 and Q900 have 2 power cables.
• The live connector in certain 115V models is coloured RED.
• The amplier must be connected to a 3-pin grounded outlet via a 3-pin connector of sufcient voltage and current rating. If the connector has provision for a fuse, a suitable fuse must be tted.
Mains supply
• The power rating of the supply should be at least twice the total audio output of the system.
• VOLTAGE SELECTION: Your amplier is factory set to your local supply voltage and should be changed only by an authorised Chevin dealer.
• ELECTRIC SHOCK/FIRE HAZARD: The unit must be connected to an adequately rated grounded outlet. All related cables, connectors and switch gear must be sufciently rated to avoid risk of overheating and re.
2
Power (continued)
Three phase systems
IMPORTANT: The neutral current will not balance on three-phase systems.
• Use individual neutral connections from each phase outlet back to the distribution point.
• Alternatively, ensure the neutral conductor is of sufcient capacity to handle a return current equal to the sum total of the current in the three phases.

Inputs

• XLR connectors are used on all amplier inputs except for Line250 and Line500 models.
• Do not directly connect any channel to more than one signal source, these are not mixing ampliers.
• All inputs are electronically balanced and can accept signals from balanced and unbalanced sources. Maintain the same phase polarity on all equipment in the signal chain.
Inputs from balanced sources
Use shielded cable with XLR connectors at both ends (except Line250 and Line500):
• Ground/screen: Connect cable braid to XLR pin 1.
• HOT (+) signal: XLR pin 2
• COLD (–) signal: XLR pin 3
Inputs from unbalanced sources
Use shielded cable with an XLR connector at the amplier end (except Line250 and Line500) and either a jack plug, phono plug or XLR connector, as appropriate:
• Ground/screen and COLD (–): At the source end, connect the COLD signal wire and cable braid to the sleeve of jack plug or phono connector, or pin 1 of an XLR connector (if used).
• At the source end of the cable, connect the HOT (+) signal to the tip of the jack plug, the pin of the phono plug or pin 2 of an XLR connector (if used).
• Connect the XLR at the amplier end as per ‘Inputs from balanced sources’ above.
Inputs to Line250 and Line500 models
The Line250 and Line500 models use block connectors at the rear panel. Use connections at the source end as explained above for balanced or unbalanced sources. At the amplier end, make wire connections rather than using an XLR connector.
Mono bridging
Various models can have their channels bridged together (except A700v, A5000, A6000, QB1000/600, Line250 or Line500). For details about the necessary wiring, see page 6.
Speakon is a registered trademark of Neutrik AG XLR is a registered trademark of ITT Cannon Ltd.
3
5

Outputs

Connections are made to the amplier load using Neutrik Speakon sockets (except for Line250 and Line500 models). As with input connectors, maintain phase polarity throughout the system.
IMPORTANT: High voltages are present at output terminals during operation and for a period afterwards. Do not connect the amplier to any other amplier output or to any equipment other than a speaker system.
Take great care to note the wiring specications particular to your amplier model:
A700v
One Speakon socket per channel, wired as follows: 1+ = HOT 2+ = NO CONNECTION
1– = COLD (not Ground) 2– = NO CONNECTION
WARNING: The A700v output is permanently connected in bridge mode. Both hot and cold outputs carry high level signal. Further bridging is impossible. No terminal of the speaker socket is connected to ground. Do not connect any part of the speaker system to ground.
A500 • A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 • A5003 • Q900
Two parallel-connected Speakon sockets (A500: one socket) per channel, wired as follows: 1+ = HOT 2+ = NO CONNECTION
1– = GROUND 2– = GROUND
A5000 • A6000
Two parallel-connected Speakon sockets per channel, wired as follows: 1+ = HOT 2+ = NO CONNECTION
1– = COLD (not Ground) 2– = COLD (not Ground)
WARNING: The A5000 / A6000 outputs are permanently connected in bridge mode. Both hot and cold outputs carry high level signal. Further bridging is impossible. Do not connect any part of the A5000 or A6000 outputs to ground. Take care when using loudspeaker controllers or processors.
Q6 • Q1004
One Speakon socket per channel, parallel connected in channel pairs: A & B, C & D. Each socket in the pair carries the output of both channels, wired as follows:
Channel A & B sockets:
1+ = HOT A 2+ = HOT B
1– = GROUND 2– = GROUND
Channel C & D sockets:
1+ = HOT C 2+ = HOT D
1– = GROUND 2– = GROUND
QB1000/600
One Speakon socket per channel, parallel connected in pairs: A & B, C & D. Each socket in the pair carries the output of both channels, wired as follows:
Channel A & B sockets:
1+ = HOT B 1000W 2+ = HOT A 600W
1– = GROUND 2– = GROUND
Channel C & D sockets:
1+ = HOT C 1000W 2+ = HOT D 600W
1– = GROUND 2– = GROUND
Line250 • Line500
Connect load to output connector blocks using the 0v terminal and either the 70v or 100v HOT terminals, as appropriate to the system.
4

Speaker power ratings

Suggested speaker ratings per amplier channel, in watts.
Model 16 8 4 2
A500 115 230 460 – A700v 450 900 – A750 160 300 600 – A1000 • Q6 230 450 900 – A1004 • Q1004 400 750 1500 – A1500 500 1000 1900 – QB1000/600 A&D 230 450 900
B&C 400 750 1500
A2000 230 500 1000 1800 A3000 350 650 1300 2300 A4000 450 800 1500 3000 A5000 • A5003 500 1000 2000 3600 A6000 800 1200 2600 4500 Q900 350 650 1300 2300

Speaker impedances

Correct loadings for all models are shown here. Multiple speakers are connected in parallel.
A700v
WARNING: Do not use a system with a total impedance less than 8.
The A700v can be used to drive a 70 volt distribution system (maximum loading 600W) or a 100 volt line system at a reduced output. Note: Do not connect a transformer between the A700v output and distribution system. Where line transformers are used to match speakers to the distribution system, adjust to suit the characteristics of the speaker.
A500 • A750 • A1000 • A1004 • A1500 • Q6 • Q1004 • QB1000/600 (per channel)
WARNING: Do not use a system with a total impedance per channel less than 4. 4 or less OR 2 or less OR 1 speaker
speakers of 16 speakers of 8 of 4
A2000 • A3000 • A4000 • A5000 • A5003 • A6000 • Q900 (per channel)
WARNING: Do not use a system with a total impedance per channel less than 2. 8 or less OR 4 or less OR 2 or less OR 1 speaker
speakers of 16 speakers of 8 speakers of 4 of 2
Note: The A5000 and A6000 models both incorporate an adjustable output limiting control, concealed behind the front panel. Consult an authorised Chevin dealer to enable this feature.
5
7

Mono bridge mode

WARNING: You cannot bridge the A700v, A5000, A6000, QB1000/600, Line250 or Line500.

Inputs

A500
1 Make a lead from the source with two XLR plugs at the amplier end.
2 HOT output from the source goes to pin 2 of Channel A XLR and pin 3 of Channel B XLR.
3 COLD output from the source goes to pin 3 of Channel A XLR and pin 2 of Channel B XLR.
4 The cable screen goes to pin 1 of both XLR plugs.
Q6 • Q1004
1 Make two leads, one for each source channel. Each lead needs 2 XLR plugs at the amplier end.
2 In each lead, HOT output from the source goes to pin 2 of the rst XLR & pin 3 of the second XLR.
3 In each lead, COLD output from the source goes to pin 3 of rst XLR & pin 2 of second XLR.
4 The cable screen goes to pin 1 of both XLR plugs.
5 In each lead, rst XLR goes to INPUT A (INPUT C) and second XLR goes to INPUT B (INPUT D).
A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 • A5003 • Q900
1 Bring the input signal into channel A as usual.
2 Make a lead with an inline XLR socket to go to the Channel A LINK connector and an XLR plug
to go to the Channel B INPUT socket.
3 Connect socket pin 2 to plug pin 3 and similarly, socket pin 3 to plug pin 2.
Q900: Make a second lead as above for channels C & D.
Outputs
A500 • A750 • A1000 • A1004 • A1500 • A2000 • A3000 • A4000 • A5003 • Q900
1 Split the speaker cable by separating the two conductors for a distance of 20cm along
cable.
2 Connect the red conductor to terminal 1+ of the Channel A Speakon connector.
3 Connect the black connector to terminal 1+ of the Channel B Speakon connector.
Do not make connections to any other terminals. Q900: Repeat the above for channels C & D.
Q6 • Q1004
1 Connect the red conductor of the speaker cable to terminal 1+ of channel A (C) Speakon conn.
2 Connect the black conductor of the speaker cable to terminal 2+ of channel B (D) Speakon conn.
WARNING: Do not make connections to terminals 1– or 2–.
Operation
Set the gain controls of both channels in the same position (preferably at maximum), and control the gain from elsewhere in the system. This ensures the load is shared equally between channels.
Loading and power output
Please see the rear page for mono bridge loading and power output values.
6

Operation & Servicing

Switching on
1 Turn the gain controls to the minimum positions.
2 Connect the unit to a mains supply of sufcient power and click the front panel switch(es)
to the ON position. Depending on the internal temperature, the fans may run.
• The green Power indicators will illuminate.
• The red Clip indicators will illuminate if overdriving is imminent.
WARNING: Keep sound levels down. High levels of sound can damage hearing.
Switching off
• Turn the gain control(s) to the minimum position(s). Click the front panel switch(es) to the OFF position and disconnect from the mains supply.
WARNING: High voltages are present at output terminals for a period after switching off.
Protection systems
• Mains power supply failure: When power is restored, the amp will AutoMute for ve seconds. Do not increase gain settings during this period. Note: A500, A700v, Line250 and Line500 do not AutoMute.
• Shorted output: The unit can operate indenitely into a shorted output. Normal operation will resume upon removal of the short circuit.
• Low load impedance: Protection is immediate.
• Clipping: The affected channel’s red Clip indicator will illuminate shortly before clipping.
A further increase in signal level will activate the SoftClip circuit.
• RF, DC or very low frequency signal at output: A self resetting circuit will activate to protect the load.
• Cooling systems: The internal fans react to both high signal level and temperature inside the unit. If the ambient temperature is high, fan speed will increase even in the absence of a signal.

Servicing

WARNING: All servicing and internal maintenance must be referred to an authorised Chevin dealer. Chevin Research accepts no responsibility or liability relating to injury or damages suffered as a result of misuse or unauthorised tampering with ampliers.
• Do not remove any covers or touch any internal parts. Do not allow any objects (e.g. screwdrivers, cable ends, etc.) to enter the unit.
• If the unit of any other electrical equipment in the system becomes wet during operation, disconnect the power source immediately. Do not touch the amplier. Consult a qualied engineer.
• If there are any signs of mechanical damage, disconnect the power source and consult a qualied engineer.
7
9
CHANNEL B
CHANNEL A
LINEAR AMPLIFIER
POWER
CLIP
SIGNAL
POWER
A500
GAIN
LINEAR AMPLIFIER
POWER
CLIP
SIGNAL
POWER
A700v
CHANNEL A CHANNEL CCHANNEL B CHANNEL D
POWER
ATTENUATION dB ATTENUATION dB
POWER POWER
CLIP CLIP
SIGNAL SIGNAL
INF INF
20 20
10 10
6 6
3 3
1 1
0 0
ATTENUATION dB ATTENUATION dB
INF INF
20 20
10 10
6 6
3 3
1 1
0 0
Q1004
600W 1000W
CHANNEL A
1000
QB
600
CHANNEL B
POWER
ATTENUATION dB
POWER
CLIP
SIGNAL
INF
20
10
6
3
1
0
ATTENUATION dB
INF
20
10
6
3
1
0
1000W 600W
CHANNEL C CHANNEL D
ATTENUATION dB
POWER
CLIP
SIGNA
L
INF
20
10
6
3
1
0
ATTENUATION dB
INF
20
10
6
3
1
0
A500
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
A700v
Q1004 • QB1000/600
Q1004QB1000/600
Channel A
gain
control
Power, Clip
and Signal
indicators
gain
control
Power, Clip
and Signal
indicators
Power, Clip
and Signal
indicators
Channel B
gain
control
Channel B
Power switchChannel A
gain
control
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
Power switchGain
control
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANELS
Channel C
gain
control
Power, Clip
and Signal
indicators
Channel D
gain
control
Power switch
8
600W
(Channel A)
gain control
Power, Clip
and Signal
indicators
1000W (Channel B) gain control
1000W (Channel C) gain control
Power, Clip
and Signal
indicators
600W (Channel D) gain control
Power switch
SN:
FUSE
I N P U T
I N P U T
O U T P U T
O U T P U T
CHANNEL A
CONNECTORWIRING
INPU
T
2 HOT 3 COLD 1 GND
OUTPUT
1+HOT 1-COLD
MINIMUM LOAD 4 OHMS
CHANNEL B
CONNECTORWIRING
INPUT
2 HOT 3 COLD 1 GND
OUTPUT
1+HOT 1-COLD
MINIMUM LOAD 4 OHMS
FUSE RATIN
G 110-120V = 16A 220-240V = 7A
PLEASE SEE
MANUAL
MADE IN ENGLAND BY
CHEVIN RESEARCH LT
D
OTLEY LS21 3LP
LINEAR AUDIO POWER
AMPLIFIER MODEL:A500
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
SN:
FUSE
I N P U T
O U T P U T
CONNECTORWIRING
INPU
T
2 HOT 3 COLD 1 GND
OUTPUT
1+HOT 1-COLD
MINIMUM LOAD 4 OHMS
FUSE RATIN
G 110-120V = 16A 220-240V = 7A
PLEASE SEE
MANUAL
MADE IN ENGLAND BY
CHEVIN RESEARCH LT
D
OTLEY LS21 3L
P
LINEAR AUDIO POWER
AMPLIFIER MODEL:A
700v
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
CONNECTORWIRING
2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECT
ORWIRING CONNECTORWIRING
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
LINEAR AUDIO POWER AMPLIFIER MODEL:QB1004
SN
INPUT D INPUT C INPUT B INPUT A
OUTPUTS OUTPUTSOUTPUTS OUTPUTS
CHANNEL C+D CHANNEL A+B
MADE IN ENGLAND BY
CHEVIN RESEARCH LT
D
OTLEY LS21 3LP
FUSE RATING 220-240V = 40A
PLEASE SEE MANUAL
LOAD 4 OHMS MINIMUM
CH.D:1+ HOT 1- COLD CH.C:2+ HOT 2- COLD
CH.A:1+ HOT 1- COLD CH.B:2+ HOT 2- COLD
CONNECTORWIRING
2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECT
ORWIRING CONNECTORWIRING
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
LINEAR AUDIO POWER AMPLIFIER MODEL:QB1000/600
SN
INPUT D INPUT C INPUT B INPUT A
OUTPUT C/D OUTPUT A/BOUTPUT C/D OUTPUT A/B
CHANNEL C+D CHANNEL A+B
MADE IN ENGLAND BY
CHEVIN RESEARCH LT
D
OTLEY LS21 3LP
FUSE RATING 220-240V = 20A 110-120V = 40A
PLEASE SEE MANUAL
LOAD 4 OHMS MINIMUM
CH.D:2+ HOT 2- COLD (600W)
CH.C:1+ HOT 1- COLD (1000W)
CH.D:2+ HOT 2- COLD (600W)
CH.C:1+ HOT 1- COLD (1000W)
CH.A:2+ HOT 2- COLD (600W)
CH.B:1+ HOT 1- COLD (1000W)
CH.A:2+ HOT 2- COLD (600W)
CH.B:1+ HOT 1- COLD (1000W
)
A500
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
Channel B
Output
connector
Input
connector
A700v
Output
connector
connector
Q1004 • QB1000/600
Q1004QB1000/600
Vari speed
cooling fan
Channel C & D
input XLR
sockets
Mains inputFuseChannel B
Channel A
Input
connector
Channel A
Output
connector
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
FuseInput
Mains input
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANELS
Channel C & D
output Speakon
sockets (1 per ch)
Fuse
Channel A & B
output Speakon
sockets (1 per ch)
Channel A & B
input XLR
sockets
Vari speed
cooling fan
Vari speed
cooling fan
Channel C & D
input XLR
sockets
Speakon sockets
Channel C & D
dual output
Fuse
Channel A & B
Speakon sockets
dual output
Channel A & B
input XLR
sockets
Vari speed
cooling fan
9
11
A750 • A1000 • A1004 • A1500 • A2000 • A3000
CHANNEL A CHANNEL B
POWER
LINEAR AMPLIFIER
Axxxx
ATTENUATION dB ATTENUATION dB
POWER
CLIP
SIGNAL
INF INF
20 20
10 10
6 6
3 3
1 1
0 0
CHANNEL A CHANNEL B
POWER
LINEAR AMPLIFIER
Axxxx
ATTENUATION dB
POWER
CLIP
SIGNAL
INF
20
10
6
3
1
0
ATTENUATION dB
INF
20
10
6
3
1
0
CHANNEL A
CHANNEL
B
POWER
POWER
LINEAR POWER
AMPLIFIER
A6000
POWER ON
POWER ON
LIMITER
LIMITER
RMS
OUTPUT
VOLT
S
RMS
OUTPUT
VOLTS
12
12
24
24
36
36
48
48
60
60
72
72
84
84
SEE PAGE 6 • FRONT PANEL
Channel A
gain
control
Power, Clip
and Signal
indicators
A4000 • A5003
Channel A
gain
control
Power, Clip and Signal
indicators
A5000 • A6000
Model shown is A6000. Signal indicator values are different for A5000.
gain
Power switchChannel B
control
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
Power switchChannel B
gain
control
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
The Limiter indicator lights when amp is being driven into clip and shows SoftClip system is active. If clip threshold is exceeded, the intensity of this LED gives an indication of the degree of overdrive.
10
Power, Signal
& Limiter
indicators
Channel A
gain
control
Channel B
gain
Channel A and B
Power switches
control
A750 • A1000 • A1004 • A1500 • A2000 • A3000
INPUT INPUT
CONNECTORWIRING
2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECTORWIRING
1+ HOT 1- COLD
CONNECTORWIRING
1+ HOT 1- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
PLEASE SEE MANU
AL SN
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
LINEAR AUDIO POWER AMPLIFIER MODEL:Axxxx
LINK LINKOUTPUTS OUTPUTSOUTPUTS OUTPUTS
FUSE
CHANNEL B CHANNEL A
MADE IN ENGLAND BY
OTLEY LS21 3L
P
CHEVIN RESEARCH LT
D
CONNECTORWIRING
2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECT
ORWIRING
1+ HOT 1- COLD
CONNECTORWIRING
1+ HOT 1- COLD
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
LINEAR AUDIO POWER AMPLIFIER MODEL:Axxxx
SN
LINK LINKINPUT INPUT
OUTPUT OUTPUTOUTPUT OUTPUT
CHANNEL B CHANNEL A
MADE IN ENGLAND BY
CHEVIN RESEARCH LT
D
OTLEY LS21 3LP
FUSE RATING
220-240V = 30A (40A
)
PLEASE SEE MANUAL
LOAD 2 OHMS MINIMUM
INPUT
INPUT
LINK
LINK
OUTPUTS
OUTPUTS
OUTPUTS
OUTPUTS
FUSE
FUSE
CHANNEL A INPUT
CHANNEL B INPUT
CHANNEL A OUTPUT
CHANNEL B OUTPUT
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECT
ORWIRING
2 HOT 3 COLD 1 GND
CONNECT
ORWIRING
1+ HOT 1- COLD
CONNECT
ORWIRING
1+ HOT 1- COLD
LOAD 2 OHMS MINIMUM
LOAD 2 OHMS MINIMUM SN
FUSE RATING
SEE LEGEND ON AMPLIFIER
FUSE RATING
SEE LEGEND ON AMPLIFIER
PLEASE SEE MANU
AL
PLEASE SEE MANU
AL
LINEAR AUDIO POWER AMPLIFIER MODEL:Axxxx
MADE IN ENGLAND BY
OTLEY LS21 3LP
CHEVIN RESEARCH LTD
MADE IN ENGLAND BY
OTLEY LS21 3LP
CHEVIN RESEARCH LT
D
WARNING
THE 2 CHANNELS OFTHIS AMPLIFIER
MUST NOT BE BRIDGED
OF ELECTRIC SHOCK
WHEN COVERS REMOVED
DANGER
SEE PAGES 3, 4 & 5 • REAR PANEL
Vari speed
cooling fan
input and link
connectors
A4000 • A5003
Vari speed
cooling fan
input and link
connectors
A5000 • A6000
Channel B
dual output
connectors
FuseChannel B
Channel A
dual output
connectors
Channel A
input and link
connectors
Vari speed
cooling fan
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
Channel B
dual output
connectors
FuseChannel B
Channel A
dual output
connectors
Channel A
input and link
connectors
Vari speed
cooling fan
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
Vari speed
cooling fans
FusesChannel A
dual output
input and link
connectors
Channel B
input and link
connectors
Channel B
connectors
Channel A dual output connectors
Vari speed
cooling fans
11
13
Q6
CHANNEL CCHANNEL A CHANNEL DCHANNEL B
Q-6
POWER
ATTENUATION dBATTENUATION dB ATTENUATION dBATTENUATION dB
POWERPOWER
CLIPCLIP
SIGNALSIGNAL
INFINF INFINF
2020 2020
1010 1010
66 66
33 33
11 11
00 00
POWER
POWER
Q900
CHANNEL B
CHANNEL
D
CHANNEL
A
CHANNEL
C
POWER
POWER
CLIP
CLIP
SIGNAL
SIGNAL
line amplifier
CHANNEL A CHANNEL B
ATTENUATION dB ATTENUATION dB
SIGNAL
CLIP
POWER
CLIP
SIGNA
L
INF INF
20 20
10 10
6 6
3 3
1 1
0 0
Line
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
Channel A
gain
control
Power, Clip
and Signal indicators
Q900
Channel A
gain
control
Channel C
control
Line250 • Line500
gain
Channel B
gain
control
Power, Clip and Signal
indicators
Channel C
gain
control
Power, Clip
and Signal
indicators
Channel D
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
Channel D
gain
control
Channel B
gain
control
SEE PAGE 6 FOR OPERATION DETAILS • FRONT PANEL
gain
control
Channel A/B
and C/D Power
switches
Power switch
12
Channel A
gain
control
Power, Clip
and Signal
indicators
Power switchChannel B
gain
control
Q6
INPUT D INPUT A
CONNECTORWIRING
2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECTORWIRING CH.C:1+ HOT 1- COLD CH.D:2+ HOT 2- COLD
CONNECTORWIRING CH.A:1+ HOT 1- COLD CH.B:2+ HOT 2- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
PLEASE SEE MANU
AL SN
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
LINEAR AUDIO POWER AMPLIFIER MODEL:Q6
INPUT C INPUT BOUTPUTS OUTPUTSOUTPUTS OUTPUTS
FUSE
CHANNEL C+D CHANNEL A+B
MADE IN ENGLAND BY
OTLEY LS21 3L
P
CHEVIN RESEARCH LT
D
INPUT
INPUT
INPUT
INPUT
CONNECTORWIRING
2 HOT 3 COLD 1 GND
CONNECT
ORWIRING
2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECTORWIRING 2 HOT 3 COLD 1 GND
CONNECT
ORWIRING
1+ HOT 1- COLD
CONNECT
ORWIRING
1+ HOT 1- COLD
CONNECT
ORWIRING
1+ HOT 1- COLD
CONNECT
ORWIRING
1+ HOT 1- COLD
FUSE RATING
SEE LEGEND ON AMPLIFIER
FUSE RATING
SEE LEGEND ON AMPLIFIER
PLEASE SEE MANU
AL
PLEASE SEE MANU
ALSNSN
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
DANGER OF ELECTRIC SHOCK WHEN COVERS REMOVED
LINEAR AUDIO POWER AMPLIFIER MODEL:Q900
LINK
LINK
LINK
LINK
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
OUTPUT
FUSE
FUSE
CHANNEL B
CHANNEL
D
CHANNEL
A
CHANNEL
C
MADE IN ENGLAND BY
OTLEY LS21 3LP
CHEVIN RESEARCH LT
D
DANGER OF ELECTRIC SHOCK
WHEN COVERS REMOVED
LINE AMPLIFIER MODEL:LINE 500/250
SN
0v
1 1
0v
OUTPUT OUTPUT
INPUT INPUT 1 GND 2 HO
T
3 COLD
1 GND 2 HO
T
3 COLD
70v
2 2
70v100v
3 3
100v
CHANNEL B CHANNEL A
MADE IN ENGLAND BY CHEVIN RESEARCH LT
D
OTLE
Y
LS21 3LP
FUSE
FUSE RATIN
G
LIN
E
220 - 240v
110 - 120v
50
0 20A 16A
250 10A 7A
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
Vari speed
cooling fan
C & D input
connectors
Q900
Vari speed
cooling fans
input & link
connectors
Line250 • Line500
Channel C+D
dual output
connectors
FuseChannel
Channel A+B
dual output
connectors
Channel A & B input connectors
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
Channel D
input & link
connectors
Channel B & channel D dual output
connectors
FusesChannel B
Channel A
& channel C
dual output connectors
Channel C
input & link
connectors
Channel A
input & link
connectors
SEE PAGE 3 FOR INPUT WIRING • SEE PAGES 4 & 5 FOR OUTPUT WIRING • REAR PANEL
Vari speed
cooling fan
Vari speed
cooling fans
Vari speed
cooling fan
FuseChannel B output
Channel A input connector block
connector block
Channel B input
connector block
Channel A output
connector block
Vari speed
cooling fan
13
15
10k
10k
10k
10k
10k
10k
14
10k
10k
1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS
dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear
(per chan.) 350W n/a 425W 600W 1000W 1250W 600W 1000W 2x1000W/2x600W
(per chan.) 200W 600W 250W 350W 600W 650W 350W 600W 2x600W/2x350W
into 4
General specications A500 A700v A750 A1000 A1004 A1500 Q6 Q1004 QB1000/600
into 8
RMS power output
No. of channels 2 1 2 2 2 2 4 4 4
Power bandwidth +0dB, -3dB 2Hz - 40kHz 2Hz - 40kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz
Slew rate in excess of 40V/µS 40V/µS 75V/µS 75V/µS 75V/µS 60V/µS 75V/µS 75V/µS 75V/µS
typical @ 1dB below clip 0.06% 0.06% 0.04% 0.04% 0.04% 0.04% 0.04% 0.04% 0.04%
20kHz @ 1dB below clip 0.08% 0.08% 0.07% 0.07% 0.07% 0.07% 0.07% 0.07% 0.07%
typ. ref. full output, unweighted -120dB -120dB 125dB -125dB -125dB -125dB -125dB -125dB -125dB
Worst case 10Hz - 30kHz -95dB -95dB -95dB -95dB -95dB -95dB -95dB -95dB -95dB
typical -115dB n/a -115dB -115dB -115dB -115dB -115dB -115dB -115dB
Gain x37.5 x70 x40 x50 x65 x70 x50 x65 x65 / x50
Total harmonic distortion
Signal to noise ratio
worst case 10Hz - 30kHz -95dB n/a -95dB -95dB -95dB -95dB -95dB -95dB -95dB
Crosstalk
electronically balanced 10k
Damping factor 400 400 400 400 400 400 400 400 400
Input impedance
ref. full output into 4
clipping soft soft soft soft soft soft soft soft soft
load below 2.4
shorted output, DC or RF at output immediate immediate immediate immediate immediate immediate immediate immediate immediate
50/60Hz AC in volts 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V
internally selectable for 100-120V 100-120V 100-120V 100-120V 100-120V 100-120V 100-120V n/a 100-120V
rack units 1U 1U 2U 2U 2U 2U 2U 3U 3U
height x width x depth (inches) 1.75x19x8.5 1.75x19x8.5 3.5x19x15 3.5x19x15 3.5x19x15 3.5x19x15 3.5x19x15 5.25x19x15 5.25x19x15
height x width x depth (mm) 44x483x215 44x483x215 88x483x381 88x483x381 88x483x381 88x483x381 88x483x381 132x483x381 132x483x381
gross weight 5.2kg/11.5lbs 5.1kg/11.2lbs 10kg/22lbs 10kg/22lbs 13.3kg/29lbs 14kg/31lbs 14kg/30.9lbs 16kg/34lbs 20kg/44lbs
Common mode rejection (typ.) -70dB -70dB -70dB -70dB -70dB -70dB -70dB -70dB -70dB
Input sensitivity
Protection
Power consumption 1.2kVA 1.2kVA 1.5kVA 2kVA 3.3kVA 4kVA 4kVA 6.6kVA 5.2kVA
Dimensions/weight
net weight 4.7kg/9lbs 4kg/8.8lbs 8.4kg/18.5lbs 8.5kg/19lbs 11.7kg/26lbs 12.4kg/27lbs 12.3kg/27lbs 14kg/29.6lbs 18kg/40.5lbs
10k
10k
10k
10k
10k
10k
10k
10k
1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS 1V RMS
dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear dynamic linear n/a n/a
(per chan.) 1600W 1200W 1600W 2000W 2500W 2500W 3000W Line operation: Line operation:
(per chan.) 900W 650W 900W 1000W 1500W 1500W 2000W 70V 100V 70V 100V
(per chan.) 500W 350W 500W 600W 900W 900W 1200W 175W 250W 350W 500W
into 2
into 4
General specications Q900 A2000 A3000 A4000 A5000 A5003 A6000 Line250 Line500
RMS power output (10Hz-20kHz)
into 8
No. of channels 4 2 2 2 2 2 2 2 2
Power bandwidth +0dB, -3dB 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 80kHz 2Hz - 50kHz 2Hz - 80kHz 2Hz - 50kHz 30Hz - 16kHz 30Hz - 16kHz
typical @ 1dB below clip 0.04% 0.04% 0.04% 0.04% 0.04% 0.04% 0.04% 0.04% 0.04%
20kHz @ 1dB below clip 0.07% 0.07% 0.07% 0.07% 0.07% 0.07% 0.07% n/a n/a
typ. ref. full output, unweighted -125dB -125dB -125dB -125dB -125dB -125dB -125dB -120dB -120dB
Worst case 10Hz - 30kHz -95dB -95dB -95dB -95dB -95dB -95dB -95dB -95dB -95dB
typical -115dB -115dB -115dB -115dB -115dB -115dB -115dB -115dB -115dB
Slew rate in excess of 50V/µS 75V/µS 50V/µS 65V/µS 50V/µS 65V/µS 50V/µS 40V/µS 40V/µS
Gain x60 x50 x60 x65 x70 x70 x90 n/a n/a
Total harmonic distortion
Signal to noise ratio
worst case 10Hz - 30kHz -95dB -95dB -95dB -95dB -95dB -95dB -95dB -95dB -95dB
Crosstalk
Damping factor 400 400 400 400 400 400 400 n/a n/a
Input imped. electronically balanced 10k
ref. full output into 4
clipping soft soft soft soft soft soft soft soft soft
load below 1.2
shorted output, DC or RF at output immediate immediate immediate immediate immediate immediate immediate immediate immediate
50/60Hz AC in volts 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V 220-240V
internally selectable for 100-120V 100-120V 100-120V n/a 100-120V n/a 100-120V 100-120V 100-120V
rack units 4U 2U 2U 3U 4U 3U 4U 3U 3U
height x width x depth (inches) 7x19x15 3.5x19x15 3.5x19x15 5.25x19x15 7x19x15 5.25x19x15 7x19x15 5.25x19x15 5.25x19x15
height x width x depth (mm) 178x483x381 88x483x381 88x483x381 132x483x381 178x483x381 132x483x381 178x483x381 132x483x381 132x483x381
gross weight 23.5kg/59lbs 13.3kg/29lbs 14kg/31lbs 16kg/34lbs 23.5kg/59lbs 16kg/34lbs 23.5kg/59lbs 18kg/40lbs 22kg/50lbs
Common mode rejection (typ.) -70dB -70dB -70dB -70dB -70dB -70dB -70dB -70dB -70dB
Input sensitivity
Protection
Power consumption 5.3kVA per pair 3.9kVA 5.3kVA 6.6kVA 4kVA per chan. 8kVA 5.3kVA per chan. 1kVA 1.6kVA
Dimensions/weight
net weight 21.5kg/47.4lbs 11.7kg/26lbs 12.4kg/27lbs 14kg/29.6lbs 21.5kg/47.4lbs 14kg/29.6lbs 21.5kg/47.4lbs 16kg/36lbs 20kg/45lbs
15
Mono bridge loading and power outputs (see page 6 for details)
Model Minimum load Power output
A500 1 load of 8 650W A750 1 load of 8 850W A1000 1 load of 8 1200W A1004 1 load of 8 2000W A1500 1 load of 8 2500W A2000 1 load of 4 2400W A3000 1 load of 4 3000W A4000 1 load of 4 4000W A5003 1 load of 4 5000W Q900 1 load of 4 per channel pair 3000W per channel pair Q6 1 load of 8 per channel pair 1200W per channel pair Q1004 1 load of 8per channel pair 2000W per channel pair
Warranty
This precision engineered CHEVIN product is guaranteed against defects due to faulty materials and workmanship for a period of twenty four (24) months from the date of the original purchase, subject to the following restrictions:
• This warranty is only valid in the country of purchase
• The equipment has not been abused or operated in conjunction with unsuitable or faulty apparatus. The equipment has not been disassembled, modied or tampered with by any person other than our CHEVIN staff or overseas by our own or distributors’ staff.
• The equipment has not suffered damage in transit.
Should service be required, notify the dealer from whom you purchased the equipment to arrange for an authorised CHEVIN agent to conrm the need for attention.
• Do not dispatch the goods without the prior approval of CHEVIN or its authorised agents. If asked to return the goods, pack them carefully (preferably in the original carton) and return pre-paid. Insurance is recommended as goods are returned at owner’s risk.
• Packing insurance and freight on the return journey will be paid for by CHEVIN or its authorised agents only if warranty work proves necessary. If warranty work proves unnecessary, goods will be released upon payment by the owner for charges for non-warranty repair work and return packing, insurance and freight.
• The attached warranty card should be completed and returned to CHEVIN RESEARCH LTD.
• Failure to register by not returning the warranty card in no way limits or invalidates the warranty, but in the event of service being required, delay may result since warranty work cannot begin until the original sale has been veried.
• In case of difculty, contact CHEVIN RESEARCH LTD. This warranty in no way affects your statutory rights.
Chevin Research Ltd., 41a Ilkley Road, Otley, West Yorkshire LS21 3LP ENGLAND
Tel: +44 (0)1943 466060 • Fax: +44 (0)1943 466020
www.chevin-research.com • sales@chevin-research.com
This manual is intended for informational purposes only. All details included herein are subject to change
without notice. Chevin Research Ltd. shall not be held responsible for any damages, direct or indirect,
arising from or relating to the use of this manual.
© Chevin Research Ltd. 2004. All rights reserved.
Range guide • 1.0c • Dec 2004
Loading...