In addition to your amplier and this manual, the carton should contain the following items:
• Neutrik® Speakon® plugs, depending on your amplier model:
• Line250, Line500 no Speakon plugs
• A700v: one Speakon plug
• Q6, Q1004, QB1000/600, Q900: four Speakon plugs
• All other models: two Speakon plugs
• A500 and A700v only. Detachable power cable with IEC connector.
• Warranty card. Please complete this card and return it to Chevin Research. Failure to
register may result in delays if you require warranty service. See rear cover for warranty.
Positioning
• Your amplier must have good ventilation. Air is drawn in at the rear panel and is expelled
at the front. It is vital to keep front and rear of unit free from obstruction.
• Your amplier may be used free-standing or installed in a 19” rack. If installed in a rack,
the rear of the chassis should be supported. Rear rack-mount supports are integral on all
models except the A500 & A700v.
Power
Wiring
• EARTHING: All Chevin ampliers must be earthed.
• A500 & A700v models connect to the mains supply via a supplied detachable power cable.
• All other models have xed power cables, colour coded to European standards:
Green/Yellow = Earth Blue=Neutral Brown= Live
• The A5000, A6000 and Q900 have 2 power cables.
• The live connector in certain 115V models is coloured RED.
• The amplier must be connected to a 3-pin grounded outlet via a 3-pin connector of
sufcient voltage and current rating. If the connector has provision for a fuse, a suitable
fuse must be tted.
Mains supply
• The power rating of the supply should be at least twice the total audio output of the system.
• VOLTAGE SELECTION: Your amplier is factory set to your local supply voltage and should
be changed only by an authorised Chevin dealer.
• ELECTRIC SHOCK/FIRE HAZARD: The unit must be connected to an adequately rated
grounded outlet. All related cables, connectors and switch gear must be sufciently rated
to avoid risk of overheating and re.
2
Power (continued)
Three phase systems
• IMPORTANT: The neutral current will not balance on three-phase systems.
• Use individual neutral connections from each phase outlet back to the distribution point.
• Alternatively, ensure the neutral conductor is of sufcient capacity to handle a return
current equal to the sum total of the current in the three phases.
Inputs
• XLR connectors are used on all amplier inputs except for Line250 and Line500 models.
• Do not directly connect any channel to more than one signal source, these are not mixing
ampliers.
• All inputs are electronically balanced and can accept signals from balanced and unbalanced
sources. Maintain the same phase polarity on all equipment in the signal chain.
Inputs from balanced sources
Use shielded cable with XLR connectors at both ends (except Line250 and Line500):
• Ground/screen: Connect cable braid to XLR pin 1.
• HOT (+) signal: XLR pin 2
• COLD (–) signal: XLR pin 3
Inputs from unbalanced sources
Use shielded cable with an XLR connector at the amplier end (except Line250 and Line500)
and either a jack plug, phono plug or XLR connector, as appropriate:
• Ground/screen and COLD (–): At the source end, connect the COLD signal wire and cable
braid to the sleeve of jack plug or phono connector, or pin 1 of an XLR connector (if used).
• At the source end of the cable, connect the HOT (+) signal to the tip of the jack plug, the
pin of the phono plug or pin 2 of an XLR connector (if used).
• Connect the XLR at the amplier end as per ‘Inputs from balanced sources’ above.
Inputs to Line250 and Line500 models
The Line250 and Line500 models use block connectors at the rear panel. Use connections at
the source end as explained above for balanced or unbalanced sources. At the amplier end,
make wire connections rather than using an XLR connector.
Mono bridging
Various models can have their channels bridged together (except A700v, A5000, A6000,
QB1000/600, Line250 or Line500). For details about the necessary wiring, see page 6.
Speakon is a registered trademark of Neutrik AG
XLR is a registered trademark of ITT Cannon Ltd.
3
5
Outputs
Connections are made to the amplier load using Neutrik Speakon sockets (except for Line250
and Line500 models). As with input connectors, maintain phase polarity throughout the system.
IMPORTANT: High voltages are present at output terminals during operation and for
a period afterwards. Do not connect the amplier to any other amplier output or to
any equipment other than a speaker system.
Take great care to note the wiring specications particular to your amplier model:
A700v
One Speakon socket per channel, wired as follows:
1+ = HOT 2+ = NO CONNECTION
1– = COLD (not Ground) 2– = NO CONNECTION
WARNING: The A700v output is permanently connected in bridge mode. Both hot and cold
outputs carry high level signal. Further bridging is impossible. No terminal of the speaker
socket is connected to ground. Do not connect any part of the speaker system to ground.
Two parallel-connected Speakon sockets (A500: one socket) per channel, wired as follows:
1+ = HOT 2+ = NO CONNECTION
1– = GROUND 2– = GROUND
A5000 • A6000
Two parallel-connected Speakon sockets per channel, wired as follows:
1+ = HOT 2+ = NO CONNECTION
1– = COLD (not Ground) 2– = COLD (not Ground)
WARNING: The A5000 / A6000 outputs are permanently connected in bridge mode. Both hot and
cold outputs carry high level signal. Further bridging is impossible. Do not connect any part of the
A5000 or A6000 outputs to ground. Take care when using loudspeaker controllers or processors.
Q6 • Q1004
One Speakon socket per channel, parallel connected in channel pairs: A & B, C & D.
Each socket in the pair carries the output of both channels, wired as follows:
Channel A & B sockets:
1+ = HOT A 2+ = HOT B
1– = GROUND 2– = GROUND
Channel C & D sockets:
1+ = HOT C 2+ = HOT D
1– = GROUND 2– = GROUND
QB1000/600
One Speakon socket per channel, parallel connected in pairs: A & B, C & D.
Each socket in the pair carries the output of both channels, wired as follows:
Channel A & B sockets:
1+ = HOT B 1000W 2+ = HOT A 600W
1– = GROUND 2– = GROUND
Channel C & D sockets:
1+ = HOT C 1000W 2+ = HOT D 600W
1– = GROUND 2– = GROUND
Line250 • Line500
Connect load to output connector blocks using the 0v terminal and either the 70v or 100v
HOT terminals, as appropriate to the system.
4
Speaker power ratings
Suggested speaker ratings per amplier channel, in watts.
Correct loadings for all models are shown here. Multiple speakers are connected in parallel.
A700v
WARNING: Do not use a system with a total impedance less than 8Ω.
The A700v can be used to drive a 70 volt distribution system (maximum loading 600W) or a
100 volt line system at a reduced output. Note: Do not connect a transformer between the
A700v output and distribution system. Where line transformers are used to match speakers to
the distribution system, adjust to suit the characteristics of the speaker.
WARNING: Do not use a system with a total impedance per channel less than 2Ω.
8 or less OR4 or less OR2 or less OR1 speaker
speakers of 16Ωspeakers of 8Ωspeakers of 4Ωof 2Ω
Note: The A5000 and A6000 models both incorporate an adjustable output limiting control,
concealed behind the front panel. Consult an authorised Chevin dealer to enable this feature.