Table of Contents....................................................................................................................................................... 1
2.1 CE Approvals (ETSI).................................................................................................................................... 2
5 Absolute Maximum Ratings................................................................................................................................11
6 DC Electrical Characteristics..........................................................................................................................12
7 Digital IO Specifications...................................................................................................................................13
8 AC Electrical Characteristics..........................................................................................................................14
9 Physical Dimensions and Footprint............................................................................................................. 16
15 Drawing of Product Label..............................................................................................................................25
18 Data Sheet Status..............................................................................................................................................26
collection of data from all nodes can be
completed in 12 seconds in a ZigBee
network composed of 100 nodes
Serial data transmit-receive for end device in
low power mode
Remotely controlling other modules in the
network with commands
ZigBee channel scanning and PANID
scanning
Analyzing topology of current network with
commands
Updating the network key with commands
Acquiring the neighbor table, routing table,
and node information with commands
Switching the current network channel with
commands
Providing abundant module registers for
users to use and providing timers,
interruptions etc. to execute users’ built-in
functions
Scanning of ambient energy values to enable
users to view jamming intensity of network
channel signals
ZigBee multicast function
ZigBee binding function
Providing DIYUE Terminal developed from
the ZigBee PRO property set
Standard JTAG or SWD programming and
real-time online commissioning via IAR
SZU06C2 PM(Rev 2.0)
RF Features
Based on the Silicon Labs EFR32MG1 chip
solution
2.4 GHz ISM frequency band
250 Kbps data transmission rate over the air
16 channels (IEEE802.15.4: CH11–CH26)
Maximum output power: +19.5dbm
Signal sensitivity: -101dBm@1% PER
Sleep current: 3.0μA
RX current :13.7mA
TX current: 139mA @+19.5dBm
Visible barrier-free communication distance:
1300 m@-69dBm, PER=0.5‰
Smart power grid
Smart Energy
Wireless alarm
Safe home
Smart household
Smart building
Smart agriculture
Wireless sensor network
M2M Industrial control
Lighting, ventilation control
Remote monitoring
Environmental monitoring and control
Contain all of the platform which can quickly
establish a simple Mesh network and
evaluate SZU06C2 ZigBee wireless
communication module performance
AT-style software interface command
dictionary can be modified for high volume
customers.
Custom software development available
upon special request
Applications
SZU06C2 Product Manual
Development kit
SZU06C2 PM(Rev 2.0)
SZU06C2 Product Manual
1
1
General
1.1 Module introduction
1.2 Hardware description
SZU06C2 introduced in this document is an embedded wireless communication module based
on IEEE802.15.4/ZigBee technology. The hardware has taken the EFR32MG1B232
solution of Silicon Labs and the software adopts the SZU06 AT command set self developed
based on Ember Z-net_5.9.0 protocol stack released by Silicon Labs.
The advanced hardware design and the simple AT command interface enables SZU06C2
ZigBee wireless communication module to be blended into the wide range of applications.
Due to the strong configuration function of SZU06C2 AT command set, you can develop the
products without extra MCU to save more time and cost. Besides, SZU06C2 ZigBee wireless
communication module is also an ideal platform for development of ZigBee firmware apart
from the use of customized firmware.
You can add the strong network function into your products without radio frequency experience
or expertise, which can greatly shorten the research and development period of products and
further speed up the marketing of the products.
[1]
chip
SZU06C2 ZigBee wireless communication module is composed of the high performance and
low power consumption RF chip EFR32MG1B232 from Silicon Labs, 38.4MHz system clock
crystal oscillator, 32.768KHz monitoring clock oscillator and RF radio frequency front-end
matching circuit which can optimize the radio frequency performance.
The module has been integrated a snake antenna on board, so that you can integrate it into
your own products easily.
The maximum output power of RF chip is 19.5dBm, and the receive sensitivity is -101dBm
typically.
SZU06C2 PM(Rev 2.0)
SZU06C2 Product Manual
2
Module
Chip
FLAH
RAM
Sealing Dimension
SZU06C2
EFR32MG1B232
256KB
32KB
19mm * 25mm * 3.7mm
2
Approvals
2.1
CE Approvals (ETSI)
EMC: Draft ETSI EN 301 489-1 V2.2.0:2017
Radio: EN 300 328 V2.1.1:2016
Safety: EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013
Table 1- 1 Model of SZU06C2 Module
The SZU06C2 is used for ZigBee applications (www.zigbee.org). If you don’t want to use the
AT command interface we provided and expect to develop your own software, you need to
download the official Simplicity Studio V4 development tool and Ember Z-net_5.9.0 or later
protocol stack of Silicon Labs.
SZU06C2 ZigBee wireless communication module is certified CE by the following standards:
Draft ETSI EN 301 489-17 V3.2.0:2017
EN 62479:2010
When SZU06C2 ZigBee wireless communication module is embedded into an OEM product, it
is prohibited to declare that his OEM products comply with CE certification in the name of
approved CE certification of our company. If the OEM manufacturer wants to declare that his
final products comply with CE certification, it must be ensured that the final products shall
comply with the European EMC, Radio and Safety standards. Otherwise, ChengDu DiYue
Technology Co., Ltd. has the right to investigate and affix the responsibility for it.
SZU06C2 PM(Rev 2.0)
SZU06C2 Product Manual
3
2.2
FCC Approvals
The SUZ06C2 ZigBee wireless communication module has been tested to comply with Part 15
of the FCC rules.
FCC caution:
The "CE" marking must be placed in a prominent position of OEM products. Please refer to
http://ec.europa.eu/enterprise/faq/ce-mark.htm for more information about CE certification
mark.
Important tips:
In Europe, frequency band of 2.4GHz is used only for the equipment with the maximum
equivalent isotropically radiated power (e.i.r.p.) of less than 10mW(10dBm). In case that e.i.r.p.
of the equipment is more than 10mW, the Manufacturer or Authorized Agent must notify the
competent authorities of the spectrum management of the relevant member state prior to four
weeks that the products are put on the market. Besides, the equipment must be marked with
warning symbol to draw the user's attention to the fact that it might not be legal to use the
equipment in every member state.
For this reason, we recommend that the European customers limit the output power to 10mW
(10dBm) to avoid having to deal with the local authorities for spectrum management of each
relevant member state.
This device complies with Part 15 of the FCC rules. Operation is subject to the following
SZU06C2 PM(Rev 2.0)
SZU06C2 Product Manual
4
Note:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
Consult the dealer or an experienced radio/TV technician for help.
Please take attention that changes or modification not expressly approved by the party
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
connected.
responsible for compliance could void the user’s authority to operate the equipment.
FCC RF EXPOSURE STATEMENT:
The device has been evaluated to meet general RF exposure requirement, The device
can be used in portable exposure condition without restriction.
WARNING: To satisfy FCC RF exposure requirements for mobile transmitting
devices, a separation distance of 20cm or more should be maintained between the
antenna of this device and persons during operation. To ensure compliance,
operations at closer distances than this are not recommended.
SZU06C2 PM(Rev 2.0)
5
2.3
ATEX Approvals
The SZU06C2 ZigBee wireless communication module has been tested to comply with the
U =3.9V, I =1A, P=0.98W, C =15.32 μF, L =5.64μH, -40T80 .℃℃
And it complies with the following standard:
EN 60079-0:2012+A11:2013
EN 60079-11:2012
Ex marking:
When installing the SZU06C2 module into your own product and requiring explosion protection,
please make sure that your product must meet the above explosion-proof parameters and
indicate "Transceiver Module II 3G Ex ic IIC Gc" or similar words outside the final product.
SZU06C2 Product Manual
Certificate number:
Name And Address Of Notified Body:TÜV SÜD Product Service GmbH
Number Of Notified Body:0123
Zertifizierstellen
Ridlerstraße 65
80339 MÜNCHEN
GERMANY
Special conditions for safe use:
1. The sign “U“ placed after the certificate number indicates that the certificate must not
be mistaken with a certificate intended for an equipment or protective system. This
SZU06C2 PM(Rev 2.0)
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.