4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
CHENBRO
4-Port SAS / SATA-II Backplane
80H102209-010
User’s Manual
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
Version B0
July / 18 / 2008
1
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Copyright
Copyright © 2006 Chenbro Micom Co., Ltd.. All rights reserved.
Unless otherwise indicated, all materials in this manual are copyrighted by Chenbro Micom Co., Ltd.. All rights reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission.
Chenbro Micom Co., Ltd. reserves the right to make improvement and mo dification to the pro duct s indicated in this manual at any time. Specifications are therefore subject to change without prior notice.
Information provided in this manual is intended to be accurate and reliable. However, Chenbro Micom Co., Ltd., assumes no responsibility for its use, nor for any infringement s upon the right s of third p arties, whi ch may result from its use.
Technical Support
Chenbro works hard to offer our customers maximum performance from our chassis. But in case you have any problem with our product you can find supports from the following resources.
Web Support
Detail information of our products is in our website. You can find technical updates, installation guides, FAQs, technical specifications and more. Our web address is: www.chenbro.com
Email Support
You can also fill out the technical support form at our Technical Support page. You technical issue inquiries will be sent directly to our support professionals.
Phone Support
You can also contact Chenbro HQ or branch offic e for immediate support; contact Information is as
.
following:
Chenbro HQ Chenbro Europe B.V.
Tel: 886-2-8226-5500 Tel: 31-40-295-2045 Tel: 1-909-947-3200 Fax: 886-2-8226-5423 Fax: 31-40-295-2044
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
Chenbro Micom (USA) Inc.
Fax : 1-909-947-4300
2
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Contents
Copyright.....................................................................................................................................................2
Technical Support.....................................................................................................................................2
Contents.......................................................................................................................................................3
Revision History ........................................................................................................................................4
Backplane Specification..........................................................................................................................5
Hardware Specification....................................................................................................................5
Accommodated Chassis..................................................................................................................5
Backplane Layout..............................................................................................................................6
Power Supply Alarm Mute Connector Definition......................................................................8
Power Supply Alarm Signal Connector Definition ...................................................................8
Chassis Assembly Example ...................................................................................................................9
Example for RM31408 chassis SATA backplane wiring..........................................................9
Ordering Information..............................................................................................................................10
Compatible Chassis List................................................................................................................10
HDD Cage with Backplane - Bulk Packing Part Number List..............................................10
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
3
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Revision History
Date Modifications
July / 18 / 2008 z First Release
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
4
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Backplane Specification
Hardware Specification
Host Interface SA TA-II HDD Interface SAS (22+7) and SATA-II compatible Hot-Swap Yes, allo ws user to replace Har d Disk Drive (HDD) on line
LED indicates HDD status (Defined by Chenbro)
Display
Cooling Two Fan connectors Environment Monitor Fan speed and temperature detect
Connectors
Dimensions 107.8 (Width) x 114.8 (Height) x 2.1 (Thickness) mm Material FR4 4 layer
Power LED – Blue ( When HDD is present ) Access LED –Green (When HDD is busy ) Error indicator – Red (Error when retreating signals )
SATA 7-pin x4 to host SAS (22+7) x4 ( for HDD ) Standard 4P Power connector x 2 (+5V & +12V from power supply)
Accommodated Chassis
This backplane can be applied to the Chassis as below:
z SR105 / SR107 / SR108 / SR209 z RM31408
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
5
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0
CN5
SW1CN3
CN23
CN13
CN33
CN43
C
C
CN3
C
User’s Manual
Backplane Layout
Backplane Connectors
N41
1
N21
N11
LD41 LD42
LD31 LD32
LD21 LD22
LD11 LD12
Front View (HDD Side)
CN4
Rear View (Host Side)
CN2
CN1
JF2
JF1JP1JM1
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
6
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
(1) [CN11 / CN21 / CN31 / CN41] : Connect to 22-pin SATA-II or 29-pin SAS HDD
(2) [LD11 / LD21 / LD31 / LD41] : Blue LED Indicate HDD Power (3) [LD12 / LD22 / LD32 / LD42] : Green LED Indicate HDD Activity Red LED Indicate HDD Failure (4) [CN13 / CN23 / CN33 / CN43] : Connect to 7-pin SATA-II Host (5) [CN1 /CN2] : 4-pin Power connectors (6) [JF1 / JF2] : 3-pin Fan1 & Fan2 connectors (7) [JP1] : Power Failure Input (From Redundant Power Supply) (8) [JM1] : Power Failure Alarm Mute Outpu t (to Redunda nt Power Supply) (9) [CN3] : HDD Activity LED Signal Input connector (from RAID Card)
Pin 1
HDD1 HDD2
HDD3
HDD4
Key Pin
Remove Jumper and connect the 5-pin to 4-pin HDD LED cable to the CATHODE of the HDD activity connector on RAID card. Refer to your RAID card’s user manual for the detailed pin definition
(10) [CN4] : HDD Fail LED Signal Input connector (from RAID Card)
Pin 1
HDD1 HDD2
HDD3
HDD4
(11) [CN5] : Fan / Power / Temperature Fail LED output connector (to Front Panel LED Display)
Pin Definition Function
1 LED(+) FAN/Power/Temp Fail LED 2 N/A 3 LED(-) Alarm Mute Switch 4
Buzzer Mute (+)
Key Pin
5 Key Pin 6 Buzzer Mute (-)
(12) [SW1] : Function Switch
SW1-1 SW1-2 SW1-3
Fan1 Monitoring
ON
Enable Fan1 Monitoring
OFF
Disable
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
Fan2 Monitoring Enable
Fan2 Monitoring Disable
7
System Alarm T emperature is 65°C
System Alarm T emperature is 55°C
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Power Supply Alarm Mute Connector Definition
Pin 1: Ground Pin 2: Alarm mute signal output to PSU (Active low)
Power Supply Alarm Signal Connector Definition
Pin 1: Ground Pin 2: PSU fail signal (TTL) input from PSU (Active low)
Only redundant PSU come with the failure alarm and alarm mute reset control via signal connector. Make s ure the redundant PSU that user applied come with the connectors above.
Pin 2
Pin 1
Pin 2
Pin 1
This picture shows the standard “2510 2-pin” type PSU alarm signal connectors which fitting Chenbro LED board.
Mute (Yellow & Black wire)
TTL (Red & Black wire)
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
8
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Chassis Assembly Example
See below for the example of how the wiring to be performed.
Example for RM31408 chassis SATA backplane wiring
SA TA RAID Card
LED Cable
SATA cable (BP to Host Adaptor, 4x cables per BP)
Chassis fans wiring (Connection start from Fan1)
2-pin System Failure LED & Alarm Mute Cables (BP to Front Panel LED Display)
Chassis Fan x2Chassis Fan x2
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
9
4-Port SAS / SATA-II Backplane 80H102209-010 ver. B0 User’s Manual
Ordering Information
Compatible Chassis List
Part No. Description Chassis Model
80H102209-010 SAS/SA TA-II, 4-port Backplane
SR209 / SR105 / SR107 / SR108 / RM31408
HDD Cage with Backplane - Bulk Packing Part Number List
Part No. Description Chassis Model
84H220910-041 HDD Cage with SAS/SATA-II, 4-port Backplane SR209 / SR105
84H210710-045 HDD Cage with SAS/SATA-II, 4-port Backplane SR107 / SR108
84H331410-009 HDD Cage with SAS/SATA-II, 4-port Backplane RM31408
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
10
Loading...