Chenbro RM23612 User Manual

12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
CHENBRO
Storage Chassis
12-Port 6Gb/s Mini-SAS Backplane
80H10323602A1
User’s Manual
w w w . c h e n b r o . c o m
Feb / 10 / 2013
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
1
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Copyright
Copyright © 2013 Chenbro Micom Co., Ltd.. All rights reserved.
Unless otherwise indicated, all materials in this manual are copyrighted by Chenbro Micom Co., Ltd.. All rights reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission.
Chenbro Micom Co., Ltd. reserves the right to make improvement and modification to the products indicated in this manual at any time. Specifications are therefore subject to change without prior notice.
Information provided in this manual is intended to be accurate and reliable. However, Chenbro Micom Co., Ltd., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use.
Technical Support
Chenbro works hard to offer our customers maximum performance from our chassis. But in case you have any problem with our product you can find supports from the following resources.
Web Support
Detail information of our products is in our website. You can find technical updates, installation guides, FAQs, technical specifications and more. Our web address is: www.chenbro.com.
Email Support
You can also fill out the technical support form at our Technical Support page. You technical issue inquiries will be sent directly to our support professionals.
Phone Support
You can also contact Chenbro HQ or branch office for immediate support; contact Information is as following:
Chenbro HQ Chenbro Europe B.V.
Tel: 886-2-8226-5500 Tel: 31-40-295-2045 Tel: 1-909-947-3200
Chenbro Micom (USA) Inc.
w w w . c h e n b r o . c o m
Fax: 886-2-8226-5423 Fax: 31-40-295-2044 Fax : 1-909-947-4300
Chenbro UK LTD Chenbro China Office
Tel: 44-(0)161-425-5341 Tel: 86 010-6709-1786 Fax: 86 010-8791-0567
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
2
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Contents Technical Support Copyright Revision History Backplane Specification Backplane Hardware Backplane Assembly Backplane Wiring
Appendix
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
3
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Revision History
Date Modifications
Feb / 10 / 2013 First release (V1.0)
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
4
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
6Gb/s Backplane Specification
P/N : 80H10323602A1 (Version A0)
Specification Host Interface HDD Interface Hot-Swap
Display
Cooling Audio Environment Monitor
Connectors
MINI-SAS SAS Yes, allows user to replace hard disk drive during power on LED indicates Hard Disk Drive status
Power LED – Blue (When HDD is present) Access LED – Green (When HDD is busy) Error LED – Red (When HDD is error)
Four PWM fan connector One system monitor buzzer warning Temperature sensor detect (RT1, RT2)
1.SAS 29P *12
2.MINI-SAS Connector *3
3.Standard 4P Power connector *4 for +5V, +12V from power supply
4. 2P Wafer Connector 2.54mm (1x2) *1 -- CN06
5. Pin header 2.54mm (2x3) *1 -- CN05
6. 2510 Wafer Connector 2.54mm (1x2) *2 -- JP1 & JM1
7. 2510 Wafer Connector 2.54 (1x4)*4 -- JF1 ~ JF4
Dimension Material
425(L) x 72.7(W) x 2.4(H) mm FR4 4 layer
Accommodation Chassis
RM23612
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
5
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1
JM1
User’s Manual
Backplane Hardware
Backplane Layout
Front View
CH111 CH101 CH091
CH121
CH071 CH061 CH051
CH081
CH031 CH021 CH011
CH041
Rear View
JT1
JT2
CN06
JP1 CN05
CN01 CN03
CN02
CB3
CB2
CN04
JF1 JF2 JF3 JF4
CB1
SW1
JA4
JA3
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
6
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Components Description Function CN011 ~ CN121 29 pin SAS Connector – to HDD For SAS/SATA HDD connection CB1 ~ CB3 Mini-SAS SFF-8087
Connector – Input JF1 ~ JF4 PWM fan Connector Chassis cooling fan connection CN01 ~ CN04 Power Connector DC in, 4-Pin, +5V/+12V from Power Supplier SW1 DIP Switch The function is for fan control enable and disable
JP1 Power Failure Alarm Connector Connect to Redundant PSU for power failure alarm
JM1 Power Failure Mute Connector Connect to Redundant PSU for power failure mute
CN05 LED board connector Signal connection to chassis LED board CN06 M/B PWM fan Connector Gets either PWM duty cycle of M/B or B/P for
Internal input from SAS RAID Card or M/B
switching.
signaling
signaling
comparison to control fan speed , required one optional special cable (26H11313601A0)
(Please see Appendix 1 for duty cycle definition) JA3/JA4 Multi ICE pin connector Factory reserved for upgrade & debug JP2/JP3 IIC Connector Factory reserved JT1/JT2 Test Connector Factory reserved for thermal contact
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
7
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Backplane Connectors
POWER Connector (CN01 ~ CN04)
Pin
Descriptions
NO.
1 12V 2 GND 3 GND 4 5V
Remarks: Average loading is 7A for one connector
Fan Connector (JF1 ~ JF4)
Pin
Descriptions
NO.
1 GND 2 12V 3 FAN Clock Input 4 FAN PWM Output
MB PWM Connector (CN06)
Pin
Descriptions
NO.
1 FAN Clock Output to MB 2 FAN PWM Input from MB
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
w w w . c h e n b r o . c o m
8
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
SW1 FUNCTION
SW1-1: FAN1 Monitor Enable/Disable Setting
Sw1-1 FAN1
ON Enable
OFF Disable (Default)
SW1-2: FAN2 Monitor Enable/Disable Setting
Sw1-2 FAN2
ON Enable (Default)
OFF Disable
SW1-3: FAN3 Monitor Enable/Disable Setting
Sw1-3 FAN3
ON Enable (Default)
OFF Disable
SW1-4: FAN4 Monitor Enable/Disable Setting
Sw1-4 FAN4
ON Enable (Default)
OFF Disable
SW1-5: MB PWM Monitor Enable/Disable Setting
w w w . c h e n b r o . c o m
Sw1-5 MB PWM
ON Enable
OFF Disable (Default)
SW1-6: TEMP Threshold Setting
Sw1-6 TEMP
ON
OFF
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
9
55℃℃(Default)
65℃℃
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
HDD IN Connector pin assignment (CH011 ~ CH121)
Pin
Pin
Descriptions
NO.
NO. S1 GND P1 NC S2 RP P2 NC
Descriptions
S3 RN P3 NC S4 GND P4 GND S5 TN P5 POWER ENABLE S6 TP P6 GND S7 GND P7 5V PRE-CHARGE S8 NC P8 5V S9 NC P9 5V
S10 S11 S12 S13 S14
NC P10 NC P11 NC P12 NC P13 NC P14
P15
GND
ACCESS SIGNAL
GND
12V PRE-CHARGE
12V 12V
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
10
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Mini SAS CONNECTOR (CB1 ~ CB3)
Front View
Pin No.
Descriptions Pin No. Descriptions
A1 GND B1 GND A2 RP1 B2 TP1 A3 RN1 B3 TN1 A4 GND B4 GND A5 RP2 B5 TP2 A6 RN2 B6 TN2 A7 GND B7 GND A8 SG_CK B8 NC
A9 SG_LD B9 GND A10 GND B10 SG_DO A11 NC B11 SG_DI A12 GND B12 GND A13 RP3 B13 TP3 A14 RN3 B14 TN3 A15 GND B15 GND A16 RP4 B16 TP4 A17 RN4 B17 TN4 A18 GND B18 GND
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
11
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1
pin) see note
User’s Manual
Backplane Assembly
The Chenbro 12-Port 6Gb/s Mini-SAS Backplane can be assembled on Chenbro Storage Server Chassis RM23612 only. Please refer to the Chassis Quick Installation Guide for detail information.
Figure : Front and Rear View of 12 port Backplane
Backplane Wiring
Chassis Fan x4 ( Max.)
HBA / RAID Card
Mini-SAS cable
Fan cable
M/B PWM / clock Fan signal
Note :
cable ( 2-pin to 4-
w w w . c h e n b r o . c o m
This optional cable (26H11313601A0) subjects to PWM and clock signal connection between M/B and B/P, to get PWM duty signal ( depends on thermal sensor on M/B ) for comparison with B/P and control fan speed. Meantime, report fan clock signal to M/B for fan speed indication in the system.
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
12
12-Port 6Gb/s Mini-SAS Backplane 80H10323602A1 User’s Manual
Appendix 1
PWM fan duty cycle definition table
Temperature () <= 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Loading percentage (%) 34% 38% 42% 46% 50% 54% 58% 62% 66% 70% 73% 76% 79% 82%
85% 46 47 48 49 >= 50
88%
91%
94%
97%
100%
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 e-mail: info@chenbro.com.tw
13
Loading...