Chenbro RM23608 User Manual

8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
CHENBRO
Storage Chassis
8-Port 6Gb/s SAS/SATA Backplane
80H10323601A1
User’s Manual
w w w . c h e n b r o . c o m
Feb / 10 / 2013
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
1
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
Copyright
Copyright © 2012 Chenbro Micom Co., Ltd.. All rights reserved.
Unless otherwise indicated, all materials in this manual are copyrighted by Chenbro Micom Co., Ltd.. All rights reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission.
Chenbro Micom Co., Ltd. reserves the right to make improvement and modification to the products indicated in this manual at any time. Specifications are therefore subject to change without prior notice.
Information provided in this manual is intended to be accurate and reliable. However, Chenbro Micom Co., Ltd., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use.
Technical Support
Chenbro works hard to offer our customers maximum performance from our chassis. But in case you have any problem with our product you can find supports from the following resources.
Web Support
Detail information of our products is in our website. You can find technical updates, installation guides, FAQs, technical specifications and more. Our web address is: www.chenbro.com.
Email Support
You can also fill out the technical support form at our Technical Support page. You technical issue inquiries will be sent directly to our support professionals.
Phone Support
You can also contact Chenbro HQ or branch office for immediate support; contact Information is as following:
Chenbro HQ Chenbro Europe B.V.
Tel: 886-2-8226-5500 Tel: 31-40-295-2045 Tel: 1-909-947-3200
Chenbro Micom (USA) Inc.
w w w . c h e n b r o . c o m
Fax: 886-2-8226-5423 Fax: 31-40-295-2044 Fax : 1-909-947-4300
Chenbro UK LTD Chenbro China Office
Tel: 44-(0)161-425-5341 Tel: 86 010-6709-1786 Fax: 86 010-8791-0567
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
2
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
Contents Technical Support Copyright Revision History Backplane Specification Backplane Hardware Backplane Assembly Backplane Wiring
Appendix
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
3
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
Revision History
Date Modifications
Feb / 10 / 2013 First release (V1.0)
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
4
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
6Gb/s Backplane Specification
P/N : 80H10323601A1 (Version A0)
Specification Host Interface HDD Interface Hot-Swap
Display
Cooling Environment Monitor
Connectors
SATA SAS Yes, allows user to replace hard disk drive during power on stage LED indicates Hard Disk Drive status
Power LED – Blue (When HDD is present) Access LED – Green (When HDD is busy) Error LED – Red (When HDD is error)
Four PWM FAN CONNECTOR Temperature sensor detect(RT1, RT2)
1.SAS 29P *8
2.SATA 7P *8
3.Standard 4P Power connector *4 for +5V, +12V from power supply
4. 2P Wafer CONN 2.54mm (1x2) *1
5. Pin header 2.54mm (2x5) *2
Dimension Material
Accommodation Chassis
RM23608
425(L) x 54.7(W) x 2.4(H) mm FR4 4 layer
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
5
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1
CN07
CN06
User’s Manual
Backplane Layout
Backplane Connectors
Front View
CH71 CH61 CH51
CH81
CH11
CH21
CH31
CH41
CN04
Rear
CN03
View
CH82
CH72
CH52CH62
JF4
JF1
JF2
JF3
CH22
CN02
CN01
CH32CH42
CN05
CH12
SW1
(1) [CH11 ~ CH41 / CH51 ~ CH81] : 22-pin SATA-II or 29-pin SAS ( for HDD)
(2) [JF1 / JF2 / JF3 / JF4] : PWM Fan connectors 1~4
(3) [CN01 ~ CN04] : 4-pin Power connectors
(4) [CN07] : M/B fan signal connector ( Clock and PWM )
(gets either PWM duty cycle of M/B or B/P for comparison to
control fan speed , required one special cable)
(5) [SW1] : DIP switch function for fan control enable and disable
(detail information see below)
(6) [CH12 ~ CH42 / CH52 ~ CH82] : 7-pin SATA connector (for system)
(7) [CN05 ~ CN06] : 10-pin connector (for SGPIO signaling) (8) [JA1] : 10-pin connector (factory reserved)
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
6
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
POWER Connector (CN01 ~ CN04)
Pin
Descriptions
NO.
1 12V 2 GND 3 GND 4 5V
Fan Connector (JF1 ~ JF4)
Pin
Descriptions
NO.
1 GND 2 12V 3 FAN Clock Input 4 FAN PWM Output
MB PWM Connector (CN07)
Pin
Descriptions
NO.
1 FAN Clock Output to MB 2 FAN PWM Input from MB
(gets either PWM duty cycle of M/B or B/P for comparison to control fan speed , required one special cable P/N: 26H11313601A0)
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
7
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
SGPIO SIGNAL CONNECTOR (CN05 & CN06)
Pin
Pin
Descriptions
NO.
NO.
Descriptions
1 SGPIO DATA INPUT 2 NC 3 SGPIO DATA OUTPUT 4 GND 5 GND 6 SGPIO LOAD 7 CONTROL TYPE 8 SGPIO CLOCK 9 NC 10 KEY PIN
Remarks: CN05 for HDD connector CH11 ~ CH41 CN06 for HDD connector CH51 ~ CH81 Recommend SAS/SATA cable with SGPIO side band supporting as below,
mini SAS SFF-8087 to 4 SATA with side band (P/N: 26H12323601A0)
HOST IN Connector (CH12, CH22, CH32, CH42, CH52, CH62, CH72, CH82)
Pin NO.
Descriptions
1 GND 2 RP 3 RN 4 GND 5 TN 6 TP 7 GND
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
8
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
SW1 FUNCTION
SW1-1: FAN1 Monitor Enable/Disable Setting
Sw1-1 FAN1
ON Enable
OFF Disable (Default)
SW1-2: FAN2 Monitor Enable/Disable Setting
Sw1-2 FAN2
ON Enable (Default)
OFF Disable
SW1-3: FAN3 Monitor Enable/Disable Setting
Sw1-3 FAN3
ON Enable (Default)
OFF Disable
SW1-4: FAN4 Monitor Enable/Disable Setting
Sw1-4 FAN4
w w w . c h e n b r o . c o m
ON Enable (Default)
OFF Disable
SW1-5: MB PWM Monitor Enable/Disable Setting
Sw1-5 MB PWM
ON Enable
OFF Disable (Default)
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
9
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
HDD IN Connector (CH11, CH21, CH31, CH41, CH51, CH61, CH71, CH81)
Pin
Pin
Descriptions
NO.
NO. S1 GND P1 NC S2 RP P2 NC
Descriptions
S3 RN P3 NC S4 GND P4 GND S5 TN P5 POWER ENABLE S6 TP P6 GND S7 GND P7 5V PRE-CHARGE S8 NC P8 5V S9 NC P9 5V
S10 S11 S12 S13 S14
NC P10 NC P11 NC P12 NC P13 NC P14
P15
GND
ACCESS SIGNAL
GND
12V PRE-CHARGE
12V 12V
w w w . c h e n b r o . c o m
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
10
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1
pin) see note
User’s Manual
Backplane Assembly
The Chenbro 8-Port 6Gb/s SAS/SATA Backplane can be assembled on Chenbro Storage Server Chassis RM23608 only. Please refer to the Chassis Quick Installation Guide for detail information.
Figure : Front and Rear View of 8-port Backplane
Backplane Wiring
HBA / RAID Card
HBA / RAID Card Chassis Fan x4 ( Max.) Chassis Fan x4 ( Max.)
Mini-SAS to SATA cable
Fan cable
M/B PWM / clock Fan signal
cable ( 2-pin to 4-
w w w . c h e n b r o . c o m
Note : This optional cable (26H11313601A0) subjects to PWM and clock signal connection between M/B and B/P, to get PWM duty signal ( depends on thermal sensor on M/B ) for comparison with B/P and control fan speed.
15Fl., No.150, Jian Yi Road, Chung Ho City, Taipei Hsien, Taiwan R.O.C.,
Tel: +886 2 82265500 Fax: +886 2 82265392 Email: info@chenbro.com.tw
Chassis Fan x4 ( Max.)
11
Meantime, report fan clock signal to M/B for fan speed indication in the system.
8-Port 6Gb/s SAS/SATA Backplane 80H10323601A1 User’s Manual
Appendix 1
PWM fan duty cycle definition table
Temperature () <= 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Loading percentage (%) 34% 38% 42% 46% 50% 54% 58% 62% 66% 70% 73% 76% 79% 82%
85% 46 47 48 49 >= 50
88%
91%
94%
97%
100%