Chemtronics ES567 User Manual

Static Free(TM) Floor Finish ES167, ES567, ES167E, ES567E
Static Free(TM) Floor Finish
CONSULT MSDS FOR FURTHER INFORMATION
ES167, ES567
Other non-specified industry: Antistat.
ITW Chemtronics 8125 Cobb Center Drive Kennesaw, GA 30152
Tel. 770-424-4888 or toll free 800-645-5244
Chemtrec - 1-800-424-9300 or collect 703-527-3887 24/7
ITW Chemtronics 8125 Cobb Center Drive Kennesaw, GA 30152
Tel. 770-424-4888 or toll free 800-645-5244
3/27/2013.
Material Safety Data Sheet
Product name
Supplier
Trade name
Material uses
Manufacturer
Code
MSDS #
Validation date
Print date
In case of emergency
1. Product and company identification
Static Free(TM) Floor Finish ES167, ES567, ES167E, ES567E
:
:
:
:
: :::
:
:
Product type
:
Liquid.
3/27/2013.
Signal word
2. Hazards identification
Potential acute health effects
Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.
Severely irritating to eyes. Risk of serious damage to eyes.
Harmful if swallowed.
Harmful in contact with skin. Severely irritating to the skin.
Eyes
Skin
Inhalation Ingestion
Physical state
Liquid.
WARNING!
CAUSES EYE AND SKIN IRRITATION. MAY BE HARMFUL IF ABSORBED THROUGH SKIN OR IF SWALLOWED. CONTAINS MATERIAL THAT MAY CAUSE TARGET ORGAN DAMAGE, BASED ON ANIMAL DATA.
:
:
:
:::
Odor
:
Pleasant, ester-like. [Slight]
OSHA/HCS status
:
This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).
Potential chronic health effects
Carcinogenicity
:
No known significant effects or critical hazards.
Mutagenicity
:
No known significant effects or critical hazards.
Teratogenicity
:
No known significant effects or critical hazards.
Chronic effects
:
Contains material that may cause target organ damage, based on animal data.
Color
:
Opaque.White. [Light]
Emergency overview
Hazard statements
:
Precautionary measures
:
Do not breathe vapor or mist. Do not ingest. Do not eat, drink or smoke when using this product. Avoid contact with eyes, skin and clothing. Avoid prolonged contact with eyes, skin and clothing. Wash thoroughly after handling.
1/9
CONSULT MSDS FOR FURTHER
INFORMATION
3/27/2013.
Static Free(TM) Floor Finish ES167, ES567, ES167E, ES567E
2. Hazards identification
See toxicological information (Section 11)
Medical conditions aggravated by over­exposure
Pre-existing disorders involving any target organs mentioned in this MSDS as being at risk may be aggravated by over-exposure to this product.
:
Developmental effects
:
No known significant effects or critical hazards.
Fertility effects
:
No known significant effects or critical hazards.
Over-exposure signs/symptoms
Ingestion
:
No specific data.
Skin
:
Adverse symptoms may include the following: irritation redness
Eyes
:
Adverse symptoms may include the following: pain or irritation watering redness
Inhalation
:
No specific data.
Target organs
:
Contains material which may cause damage to the following organs: central nervous system (CNS). lithium chloride
7447-41-8
1 - 4
2-(2-methoxyethoxy)ethanol
111-77-3
1 - 3
3. Composition/information on ingredients
Name
CAS number
%
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
Wash out mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention immediately.
Check for and remove any contact lenses. Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical attention immediately.
In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention immediately.
Move exposed person to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately.
4. First aid measures
Eye contact
Skin contact
Inhalation Ingestion
In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.
Notes to physician
:
::: :
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Wash contaminated clothing thoroughly with water before removing it, or wear gloves.
2/9
CONSULT MSDS FOR FURTHER
INFORMATION
3/27/2013.
Static Free(TM) Floor Finish ES167, ES567, ES167E, ES567E
Use an extinguishing agent suitable for the surrounding fire.
5. Fire-fighting measures
Extinguishing media
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
In a fire or if heated, a pressure increase will occur and the container may burst.
Special protective equipment for fire-fighters
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
:
Special exposure hazards
:
None known.
Suitable
:
Not suitable
:
Hazardous thermal decomposition products
:
Decomposition products may include the following materials: carbon dioxide carbon monoxide nitrogen oxides phosphorus oxides halogenated compounds metal oxide/oxides
Flammability of the product
:
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment (see Section 8).
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.
Environmental precautions
6. Accidental release measures
:
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).
Personal precautions
:
Large spill
:
Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Small spill
:
Methods for cleaning up
Put on appropriate personal protective equipment (see Section 8). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.
7. Handling and storage
Handling
:
3/9
CONSULT MSDS FOR FURTHER