Evaporation Rate (butyl acetate=1) <1
Non-Volatile Residue < 50 ppm
Kauri-Butanol
(KB) Number
Dielectric Breakdown
(ASTM D-877)
RoHS Compliant
Shelflife 5 years
CHEMTRONICS
Technical Data Sheet
Pow-R-Wash
PRODUCT DESCRIPTION
The Pow-R-Wash Cable Cleaner is a high
flash point cleaner that quickly removes
soils, adhesives, and residues from
insulation jackets and conductors on
telecom, fiber optic and coaxial cables.
Excellent wetting action lifts and removes
soils from the tightest tolerance areas. Pow-
R-Wash
Cable Cleaner is also ideal for
removing carbonization, oxidized oils and
greases from c ontacts.
Removes encrusted dirt, silicone grease
and other contaminants
Leaves no residues
No odor
Excellent dielectric stre ngth
Contains no CFCs or HCFCs
Contains no chlorinated solvents
High flash point
All-Way Spray valve-even sprays upside
down
TYPICAL APPLICATIONS
Pow-R-Wash
Cable Cleaner is engineered
to clean:
Telecom, fiber optic and coaxial cable
Contacts and Relays
Equipment and tools
Cable Cleaner
TYPICAL PRODUCT DATA AND
PHYSICAL PROPERTIES
CARB 50
SCAQMD 756
Federal 50
*Volatile Organic Compound (VOC) information is calculated on a
weight basis using the VOC definition of California Air Resources
Board (CARB) Consumer Product Regulations, South Coast Air
Quality Management District (SCAQMD) Rule 102 and the Federal
definition published in 40 CFR 51.100(s).
COMPATIBILITY
Pow-R-Wash
compatible with most materials. As with
any cleaning agent, solvent/component
compatibility must be determined on a noncritical area prior to use.
Cable Cleaner is generally

USAGE INSTRUCTIONS
For commercial use only.
Read MSDS care fully prior to use.
Spray 4-6 inches from surface to clean.
Wash parts from top to bottom, allowing the
liquid to flush away dirt and dissolved
grease. For precise application use attached
extension tube. For controlled application,
spray into a Controlwipes and wipe
surface clean.
TECHNICAL & APPLICATION
ASSISTANCE
Chemtronics provides a technical hotline to
answer your technical and application
related questions. The toll free number is:
1-800-TECH-401.
AVAILABILITY
ES2425 13.5 oz. Aerosol
ENVIRONMENTAL IMPACT DATA
Hydrochlorofluorocarbons (HCFCs) are regulated under the Montreal
Protocol as Class II ozone depleting substances. HCFC-141b is no longer
produced in the US under this legislation. HCFC-225 is planned for
production phase-out in 2015. Hydrofluorocarbons (HFCs) are not currently
regulated.
EPA has listed n-propyl bromide (nPB) as an acceptable alternative to ozone
depleting substances in metal, precision, and electronics cleaning under
Section 612 of the Clean Air Act.
NOTE:
This information is believed to be accurate. It is
intended for professional end users having the skills
to evaluate and use the data properly.
CHEMTRONICS does not guarantee the accuracy
of the data and assumes no liability in connection
with damages incurred while using it.
Chemtronics is a registered trademark of Chemtronics. All
rights reserve d. Pow-R-Wash and Controlwipes are
trademarks of Chemtronics. All rights reserved.
All other trademarks herein are trademarks or registered
trademarks of their respective owners.
CHEMTRONICS
8125 COBB CENTER DRIVE
KENNESAW, GA 30152
1-770-424-4888
REV. C (08/13)