Typical Product Data and Physical Properties
IPA Presaturated Wipes
Product# SIP100P, SIP100TR, SIP100K, IPA100B
Product Description
IPA Presaturated Wipes remove solder paste, inks and other
contaminants. These highly effective cleaning wipes are ideal
for all general cleaning applications. IPA Presaturated Wipes
are well suited for touch-up cleaning of automatic printer
stencils and cleaning of semi-automatic printer stencils during
and at the end of production runs.
Presaturated Wipes contain ultra-pure 70% electronics grade
isopropyl alcohol and 30% pure deionized water. The wipes
are available in a center pull pop-up canister.
Rev. He (5/20) Page 1 of 2
Plastic Saf
Lint free
RoHS Compliant
Flammable
Regular Cleaning Strength
California - CARB Electronics Cleaner 75% Compliant
e
Typical Applications
IPA Presaturated Wipes are engineered for cleaning:
Screens & Stencils
Cables
Hard-line Coax Cable
Metal & Fiber Optic Cable Splices
Printed Circuit Boards
Boiling Point: 180ºF / 82ºC Initial
Flash Point (TCC): 68ºF / 20ºC
Specific Gravity: 0.88
(Water = 1)
Vapor Density 198 mm Hg
@ 68ºF / 20ºC
Odor Mild Alcohol
Solubility in Water Soluble
Evaporation Rate: <1
(ether =1)
VOC Content*:
CARB 70%
SCAQMD 616 g/L
Federal 70%
Kauri-Butanol 56
(KB) Number
Shelf Life 2 years after opening
RoHS Compliant Yes
*Volatile Organic Compound (VOC) information is calculated on a weight basis
using the VOC definition of California Air Resources Board (CARB) Consumer
Product Regulations, South Coast Air Quality Management District (SCAQMD)
Rule 102 and the Federal definition published in 40 CFR 51.100(s).

IPA Presaturated Wipes
Product# SIP100P, SIP100TR, SIP100K, IPA100B
Compatibility
IPA Presaturated Wipes are generally compatible with most
materials. As with any chemical product, component
compatibility must be determined on a non-critical area prior
to use.
SIP100P
SIP100TR
Rev. He (5/20) Page 2 of 2
Wipes in pull-up tub, presaturated with
70% IPA and 30% deionized water,
(100/tub)
Refill Wipes, presaturated with
70% IPA and 30% deionized water,
(100/roll, 2 rolls/bag)
Usage Instructions
For industrial use only. Read SDS carefully prior to use.
SIP100P tub directions:
Remove top of container and peel foil seal from top of tub.
Pull the first wipe from center of roll and feed it through the
opening in the lid. Replace lid and pull first wipe from the tub
and separate at perforation. Keep container closed to prevent
wipes from drying out.
SIP100TR & SIP100K directions:
Open the reclosable slider bag and take out a roll of wipes.
From here follow the directions of the SIP100P, however
make sure to reclose the slider bag containing the remaining
refill rolls until the last one has been used.
IPA100B box directions:
Open box and remove wipes from pouch found inside box.
Pull wipes as needed from the box and close box between
uses to prevent wipes from drying out.
Cleaning directions:
General cleaning: Wipe surfaces thoroughly to remove
contaminants. When removing heavy soils, use a clean wipe
for final wipe down.
Stencil cleaning: Wipe away residual solder paste until
surface is thoroughly cleaned. Repeat with a clean wipe to
remove any trace contaminants.
SIP100K
IPA100B
Kit consists of 1 pull-up tub and 2 refill
wiper rolls, presaturated with 70% IPA
and 30% deionized water (100/roll).
C-Fold wipes presaturated with 70% IPA
and 30% deionized water, (100/box)
Environmental Impact Data
HCFC-141b None
HCFC-225 None
HFC None
ODP None
Hydrochlorofluorocarbons (HCFCs) are regulated under the Montreal Protocol
as Class II ozone depleting substances. HCFC-141b is no longer produced in
the US under this legislation. HCFC-225 is planned for production phase-out in
2015. Hydrofluorocarbons (HFCs) are not currently regulated.
EPA has listed n-propyl bromide (nPB) as an acceptable alternative to ozone
depleting substances in metal, precision, and electronics cleaning under
Section 612 of the Clean Air Act.
Technical and Application Assistance
Chemtronics provides a technical hotline to answer your
technical and application related questions.
The toll free number is: 1-800-TECH-401.
Note:
This information is believed to be accurate. It is intended for
professional end users having the skills to evaluate and use the
data properly. CHEMTRONICS does not guarantee the
accuracy of the data and assumes no liability in connection
with damages incurred while using it.