Chemtronics 1217 Data Sheet

@ 77°F
@ 77°F F/1 atm
5 years
CHEMTRONICS
Technical Data Sheet
TDS # 1217
Duster
PRODUCT DESCRIPTION
Duster is a high pr essure duster that removes particulates from e lectronic de vices. T his duster / cleaner is nonflammable, residue-free and won’t scratch delicate surfaces.
Nonflammable Leaves no residueHigh pressure for contamination control NonabrasiveExcellent material compatibility Penetrates hard to reach areasContains no ozone depleting compounds
TYPICAL APPLICATIONS Duster is engineered for all phases of electronic equipment maintenance and is particularly suited for applications involving:
Audio/Video Equipment Fax MachinesKeyboardsLaboratory Instruments MicrocomputersPhoto EquipmentPrinters
TYPICAL PRODUCT DATA AND PHYSICAL PROPERTIES
Boiling Point -15.7°F
Vapor Density (air=1)
Solubility in Water
Specific Gravity (water = 1 @77°F)
Evaporation Rate >1 (butyl acetate=1)
Appearance Clear, Colorless Gas
Odor
Flash Point (TCC)
Shelflife
COMPATIBILITY
Duster is ge nerally c ompatible w ith m ost materials used in printed circuit boa rd fabrication, including sensitive plastics and compounds. A s w ith a ny duster/cleaner, compatibility m ust be de termined on a non­critical area prior to use.
3.18
0.10% by weight
1.21
Slight Ethereal
None
Material
Compatibility
Buna-N
Excellent
Graphite
Excellent
HDPE
Excellent
LDPE
Excellent
Lexan
Excellent
Neoprene
Excellent
Cross-Linked PE
Excellent
Polyacrylate
Excellent
Polystyrene
Excellent
PVC
Excellent
Silicone Rubber
Excellent
Teflon
Excellent
Viton
Excellent
PERFORMANCE
Pressure PSIG / Temperature F
200 - P 150 S - I 100 G - 50 - 0
20
40
60
80
100
120
140
Temperature F
CFC
0.0%
VOC
0.0%
HCFC
0.0%
HFC
100.0%
CL Solv.
0.0%
ODP
0.0
Chemtronics provides a technical hotline to answer your technical and application related questions. The toll free number is:
1-800-TECH-401
.
ENVIRONMENTAL IMPACT DATA
ENVIRONMENTAL IMPACT DATA
CFC, HCFC, CL. SOLV., VOC, and HFC numbers shown are t he co ntent by w eight. O zone depletion potential (ODP) is determined in accordance with the Montreal Protocol and U .S. C lean A ir A ct of 1990. T he O DP of this product is 0.0. I t i s t he s um of t he O DP of t he substances t hat m ay c ontribute t o t he de pletion of stratospheric ozone, based upon the weight of each substance in the product’s formulation.
NOTE:
This i nformation is believed to be accurate. It is intended for professional end users having the skills to evaluate and use the data properly. CHEMTRONICS does not guarantee the accuracy of the data and assumes no liability in connection with damages incurred while using it.
USAGE INSTRUCTIONS For industrial use only. Read MSDS carefully prior to use. No special surface preparation is required prior to using Duster. Direct high pressure spray onto the area to be cleaned to remove dust, dirt and other contaminants. For optimum performance and pin point control, use Duster with the attached extension tube.
AVAILABILITY
ES517 5 oz. Aerosol ES1017 10 oz. Aerosol ES1217 8 oz. Aerosol ES1617 12 oz. Aerosol
TECHNICAL & APPLICATION ASSISTANCE
DISTRIBUTED BY:
Loading...