Technical Data Sheet
Typhoon Blast™ 70 Duster
TDS # 1025
PRODUCT DESCRIPTION
Typhoon B last™ 70 Duster i s engineered t o provide
effective p article r emoval from sen sitive an d d ifficult t o
reach surfaces, while minimizing global warming impact.
It pr ovides a m ore e conomical a lternative t o Typhoon
Blast™, and also pr ovides a lower blasting force at t he
nozzle. This moisture free and oil free duster provides the
cleanest and most efficient, non-contact method available
for particle r emoval. It i s al so e fficient as a m eans t o
quickly remove slow-drying solvents.
High pressure for particle removal and contamination
control
Useful for drying and removing solvents from
surfaces
Ultra-low global warming impact of 6
Nonflammable
Nonabrasive and Noncorrosive
Leaves no residue
Ultra-pure, filtered to <0.2 microns
CFC, HCFC and HFC free
VOC free
Non-ozone depleting
TYPICAL APPLICATIONS
Typhoon Blast™ 70 Duster is engineered for all aspects
of electronic equipment maintenance and is particularly
suited for applications involving:
Audio/Video Equipment
Computers and Other Electronic Equipment
Telephone Junction Panels
Network Routers and Switches
Lenses and Optical Surfaces
Office Equipment, Paper Shredders, Fax
Machines and Printers
Laboratory Instruments
Photo Equipment
Printed Circuit Boards
Electrical Connectors and Contacts
TYPICAL PRODUCT DATA AND PHYSICAL
PROPERTIES
-2 °F / -19 °C
47 psia @ 70 °F
Vapor Density (air=1)
Solubility in Water
@ 77°F F/1 atm
Specific Gravity
(water = 1 @77°F)
Evaporation Rate >1
(butyl acetate=1)
Appearance Clear, Colorless
Liquified Gas
Odor
Flash Point (TCC)
Shelflife
RoHS/WEEE
Status
*Global warming potential (GWP) is calculated based on a 100
year time horizon. Carbon dioxide has a GWP of 1.
4.0
0.10% by weight
1.17
Slight Ethereal
6.0*
None
COMPATIBILITY
Typhoon B last™ 70 Duster is g enerally co mpatible
with mo st ma terials u sed in p rinted c ircuit b oard
fabrication, i ncluding s ensitive pl astics a nd
compounds. A s w ith an y d uster/cleaner,
compatibility m ust be de termined on a non -critical
area prior to use.

Pressure PSIG / Temperature F
USAGE INSTRUCTIONS
For industrial use only.
Read MSDS carefully prior to use.
No s pecial s urface pr eparation i s r equired pr ior t o
using Typhoon B last™ 70 Duster. D irect high
pressure spray onto the area to be cleaned to remove
dust, di rt a nd ot her c ontaminant. F or opt imum
performance and pi n p oint c ontrol, us e w ith t he
attached extension tube.
AVAILABILITY
ES1025 10 oz. Aerosol
TECHNICAL & APPLICATION
ASSISTANCE
Chemtronics provides a technical hot line t o a nswer
your technical and application related questions. The
toll free number is: 1-800-TECH-401.
ENVIRONMENTAL IMPACT DATA
ENVIRONMENTAL IMPACT DATA
CFC, H CFC, C L. S OLV., V OC, a nd H FC num bers
shown a re t he c ontent by w eight. O zone de pletion
potential (ODP) is determined in accordance with the
Montreal Protocol and U.S. Clean Air Act of 1990. The
ODP of this product is 0.0. I t is the sum of the ODP of
the substances t hat m ay co ntribute t o t he d epletion o f
stratospheric oz one, ba sed upon t he w eight of e ach
substance i n the p roduct’s f ormulation.
VOC
consideration i s b ased on t he m aterials be ing n ot
photochemically reactive b y C ommonly U sed
Standards (material supplier).
NOTE:
This i nformation i s be lieved t o be a ccurate. It i s
intended for professional end users having the skills
to ev aluate an d u se t he d ata p roperly.
CHEMTRONICS does not guarantee the accuracy of
the data and assumes no liability in connection with
damages incurred while using it.
Chemtronics® is a r egistered tr ademark o f Chemtronics. A ll
rights reserved. Typhoon Blast™ is a tr ademark of
Chemtronics. All rights reserved.
All o ther t rademarks h erein ar e t rademarks o r r egistered
trademarks of their respective owners.
DISTRIBUTED BY: