Check Point VSX-1 3070, VSX-1 9070, VSX-1 9090 Getting Started Manual

VSX-1
Getting Started Guide
VSX NGX R65
U-40, P-20
703522 February 2009
All rights reserved. This product and related documentation are protected by copyright and distributed under licensing restricting their use, copying, distribution, and decompilation. No part of this product or related documentation may be reproduced in any form or by any means without prior written authorization of Check Point. While every precaution has been taken in the preparation of this book, Check Point assumes no responsibility for errors or omissions. This publication and features described herein are subject to change without notice.
RESTRICTED RIGHTS LEGEND:
Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS
252.227-7013 and FAR 52.227-19.
TRADEMARKS:
Please refer to http://www.checkpoint.com/copyright.html for a list of our trademarks.
For third party notices, see http://www.checkpoint.com/3rd_party_copyright.html.
3
4
Health and Safety Information
Read the following warnings before setting up or using the appliance.
Warning - Do not block air vents. A minimum 1/2-inch clearance is
required.
Warning - This appliance does not contain any user-serviceable parts.
Do not remove any covers or attempt to gain access to the inside of the
product. Opening the device or modifying it in any way has the risk of
personal injury and will void your warranty. The following instructions
are for trained service personnel only.
To prevent damage to any system board, it is important to handle it with care. The following measures are generally sufficient to protect your equipment from static electricity discharge:
When handling the board, to use a grounded wrist strap designed for static discharge elimination.
Touch a grounded metal object before removing the board from the antistatic bag.
Handle the board by its edges only. Do not touch its components, peripheral chips,
memory modules or gold contacts.
When handling processor chips or memory modules, avoid touching their pins or gold edge fingers.
Restore the communications appliance system board and peripherals back into the antistatic bag when they are not in use or not installed in the chassis. Some circuitry on the system board can continue operating even though the power is switched off.
Under no circumstances should the Lithium battery cell used to power the real-time clock be allowed to short. The battery cell may heat up under these conditions and present a burn hazard.
Warning - DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY
REPLACED. REPLACE ONLY WITH SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER. DISCARD USED
BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS
Disconnect the system board power supply from its power source before you connect or disconnect cables or install or remove any system board components. Failure to do this can result in personnel injury or equipment damage.
Avoid short-circuiting the lithium battery; this can cause it to superheat and cause burns if touched.
Do not operate the processor without a thermal solution. Damage to the processor can occur in seconds.
Chapter 1
Introduction
Welcome................................................................................... 9
VSX-1 Overview .......................................................................11
Shipping Carton Contents ......................................................... 13
VSX-1 3070 ................................................................... 13
VSX-1 9070 ................................................................... 14
VSX-1 9090 ................................................................... 15
Terminology ............................................................................16
Chapter 2
Contents
Installation and Configuration
Installation and Configuration Workflow .....................................17
Installing and Setting Up VSX-1................................................18
Ear Mount Installation..................................................... 18
Installing VSX-1 in a Rack ............................................... 20
Connecting the Cables and Power On................................ 21
Initial Configuration .................................................................23
Logging in for the First Time ............................................ 23
Configuring the Management Interface.............................. 25
Setting Network and Time/Date Properties......................... 27
Selecting Cluster Options................................................. 27
Completing the Configuration........................................... 28
VSX Appliance Recovery ...........................................................29
Chapter 3
VSX-1 Hardware
Overview .................................................................................31
Front Panel Components.................................................. 32
7
Rear Panel Components................................................... 38
Customer Replaceable Parts......................................................40
Power Supply.................................................................. 40
Cooling Fan .................................................................... 42
Expansion Line Card........................................................ 43
Hard Disk Drive............................................................... 45
Chapter 4
Registration and Support
Registration.............................................................................47
Support...................................................................................48
Where To From Here? ...............................................................48
8
Chapter
Introduction
In This Chapter
Welcome page 9
VSX-1 Overview page 11
Shipping Carton Contents page 13
Terminology page 16
Welcome
1
Thank you for choosing Check Point’s VSX-1 appliance. We hope that you will be satisfied with this solution and our support services. Check Point products provide your business with the most up to date and secure solutions available today.
Check Point also delivers worldwide technical services including educational, professional and support services through a network of Authorized Training Centers, Certified Support Partners and Check Point technical support personnel to ensure that you get the most out of your security investment.
9
Welcome
For additional information on the NGX Internet Security Product Suite and other security solutions, refer to: http://www.checkpoint.com or call Check Point at 1(800) 429-4391. For additional technical information, refer to: http://support.checkpoint.com.
Welcome to the Check Point family. We look forward to meeting all of your current and future network, application and management security needs.
10
VSX-1 Overview
The VSX-1 (Virtual System eXtension) appliance is a security and VPN solution, designed to meet the demands of large-scale environments. Based on the proven security of VPN-1, VSX provides comprehensive protection for multiple networks or VLANs within complex infrastructures. It securely connects them to shared resources such as the Internet and DMZs, and allows them to safely interact with each other. VSX is supported by SmartDefense™ Services, which provide up-to-date preemptive security.
VSX incorporates the same patented Stateful Inspection and Application Intelligence technologies used in the Check Point VPN-1 product line. It runs on high speed platforms (known as VSX gateways) to deliver superior performance in high-bandwidth environments. Administrators manage VSX via a SmartCenter server or
VSX-1 Overview
a Provider-1 Multi-Domain Server (MDS), delivering a unified management architecture that supports enterprises and service providers.
A VSX gateway contains a complete set of virtual devices that function as physical network components, such as VPN-1 gateways (firewalls), routers, switches, interfaces, and even network cables. Centrally managed, and incorporating key network resources internally, VSX allows businesses to deploy comprehensive firewall and VPN functionality, while reducing hardware investment and improving efficiency.
Key Features:
Combines Virtual Firewall, VPN, and IPS
Consolidates Up to 250 Security Gateways Onto a Single
Hardware Platform
Includes Virtualized Networking Components- Virtual routers, Virtual switches & Virtual cabling
Wire-Speed Security for Gigabit Networks
High Availability with Linear Growth Clustering
Chapter 1 Introduction 11
VSX-1 Overview
Bridge Mode Support for Transparent Internal Firewalls
Flexible Virtual Network Design
SmartDefense Services Updates
URL Filtering
This document provides:
A brief overview of essential VSX-1 appliance concepts and
features
A step by step guide to getting VSX-1 appliance up and running
12
Shipping Carton Contents
Shipping Carton Contents
This section describes the contents of the shipping carton.The contents of the carton vary depending on your appliance model.
VSX-1 3070
Table 1-1 Contents of the VSX-1 3070 Shipping Carton
Item Description
Appliance A single VSX-1 3070 appliance
Rack Mounting Accessories Hardware mounting kit
Cables •1 Power cable
1 Standard RJ-45 network cable
1 Serial console cable
1 RJ-45 loopback plug
2 CDs Includes the following:
CD1: VSX-1 Installation
CD2: VSX-1 Getting Started Guide
VSX NGX R65 documentation
Certifications, Regulations, and Documentation
Certification data sheet and user license agreement
Chapter 1 Introduction 13
Shipping Carton Contents
VSX-1 9070
Table 1-2 Contents of the VSX-1 9070 Shipping Carton
Item Description
Appliance A single VSX-1 9070 appliance
Rack Mounting Accessories Hardware mounting kit
Cables 2 Power cables
1 Standard RJ-45 network cable
1 Serial console cable
1 RJ-45 loopback plug
2 CDs Includes the following:
CD1: VSX-1 Installation
CD2: VSX-1 Getting Started Guide
VSX NGX R65 documentation
Certifications, Regulations,
Certification data sheet and user license
and Documentation
agreement
14
Shipping Carton Contents
VSX-1 9090
Table 1-3 Contents of the VSX-1 9090 Shipping Carton
Item Description
Appliance Two VSX-1 9070 appliances
Rack Mounting Accessories Hardware mounting kit
Cables •4 Power cables
2 Standard RJ-45 network cable
2 Serial console cable
2 RJ-45 loopback plug
2 CDs Includes the following:
CD1: VSX-1 Installation
Certifications, Regulations, and Documentation
CD2: VSX-1 Getting Started Guide
VSX NGX R65 documentation
Certification data sheet and user license agreement
Chapter 1 Introduction 15
Terminology
Terminology
The following VSX terms are used throughout this chapter:
Gateway: The VPN-1 engine that enforces the organization’s security policy and acts as a security enforcement point.
Security Policy: The policy created by the system administrator that regulates the flow of incoming and outgoing communication.
SmartCenter Server: The server used by the system administrator to manage the security policy. The organization’s databases and security policies are stored on the SmartCenter server and downloaded to the gateway.
SmartConsole: GUI applications that are used to manage various aspects of security policy enforcement. For example, SmartView Tracker is a SmartConsole application that manages logs.
SmartDashboard: A SmartConsole GUI application that is used by the system administrator to create and manage the security policy.
Centrally Managed Deployment: When the gateway and the SmartCenter server are installed on separate machines.
Virtual Routers: Independent routing domains within a VSX Gateway that function like physical routers.
Virtual System: A routing and security domain featuring firewall and VPN capabilities supported by a standard Check Point Gateway. Multiple Virtual Systems can run concurrently on a single VSX Gateway, isolated from one another by their use of separate system resources and data storage.
VSX Clustering: The connection of two or more VSX Gateways in such a way that if one fails, another immediately takes its place. A single VSX Gateway contains multiple Virtual Routers and Virtual Systems.
16
2
Chapter
Installation and Configuration
In This Chapter:
Installation and Configuration Workflow page 17
Installing and Setting Up VSX-1 page 18
Initial Configuration page 23
VSX Appliance Recovery page 29
This chapter covers installing and configuring the VSX-1 appliance.
Installation and Configuration Workflow
Below is an overview of the steps needed to configure your VSX-1 appliance. Each step is explained in detail further on.
To configure VSX-1:
1. Install VSX-1 by ear mount or in the rack.
2. Connect the cables and power on.
3. Log in and perform the initial configuration.
Note - A SmartCenter or Provider-1 Server is not installed locally on the VSX-1 appliance. VSX-1 appliance is only supported in a centrally managed environment.
17
Installing and Setting Up VSX-1
Installing and Setting Up VSX-1
VSX-1 appliance can be installed by ear mount or in the rack.
Ear Mount Installation
The VSX-1 appliance ships with two ear mount kits, and screws of the type shown in Figure 2-1:
Figure 2-1 Ear Mount Screws
One ear mount fits on each side of the chassis.
To assemble the ear mounts:
1. Take out the L shape ear mount kits.
2. Place the side with four holes against the chassis. The side
with two holes faces outward, as shown in Figure 2-2.
18
Figure 2-2 Ear Mounts
Installing and Setting Up VSX-1
Retaining Screws
3. Fasten the four retaining screws on each ear mount.
4. Fasten the two screws that connect the ear mount to the handle.
Chapter 2 Installation and Configuration 19
Installing and Setting Up VSX-1
Installing VSX-1 in a Rack
Install the system in the rack with the network ports facing the front of the rack.
Figure 2-3 Installing VSX-1 9070
20
Installing and Setting Up VSX-1
Figure 2-4 Installing VSX-1 3070
Connecting the Cables and Power On
1. Connect the power cables.
2. On the back panel, turn on the Power button to start the appliance.
Note - When a power supply fails or is not connected to the outlet, an alarm sounds continuously. If you hear the alarm, replace the faulty power supply immediately, and connect the new unit to an A/C outlet. See “Removing the Power Supply”
on page 41 for more information.
3. Wait for the appliance to initialize and boot. The status of the appliance appears on the LCD screen:
Chapter 2 Installation and Configuration 21
Installing and Setting Up VSX-1
The appliance is ready for use when the model number is displayed. The example shown above is specific to VSX-1
9070.
22
Initial Configuration
In This Section
Logging in for the First Time page 23
Configuring the Management Interface page 25
Setting Network and Time/Date Properties page 27
Selecting Cluster Options page 27
Completing the Configuration page 28
Logging in for the First Time
Initial Configuration
To log in to the VSX-1 appliance for the first time:
1. Connect to the appliance’s Serial console using the cord received in your shipping carton: RJ45/D subminiature cable.
The Serial console settings should be as follows:
Speed: 9600
Data bits: 8
Parity: None
Stop bit: 1
2. Log in for the first time using username and password. Follow the on-screen instructions to change the password, and optionally, to change the administrator username.
3. Press Enter. The command prompt appears.
admin
as the default
4. Type: access. Log in to expert mode using the username and password set in step 2.
expert
Chapter 2 Installation and Configuration 23
to enter the high privilege command line
Initial Configuration
5. Follow the on-screen instructions to change the expert mode password.
6. Run:
sysconfig
to begin the configuration
A welcome screen opens.
7. Type n to continue the network configuration process.
8. Follow the on-screen instructions to change the Host Name, Domain Name, and Domain Name Servers, as you choose based on your configuration.
See “Configuring the Management Interface” on page 25 for detailed instructions on changing the Management interface IP address from the pre-configured IP address to one that you choose.
24
Initial Configuration
Configuring the Management Interface
To change the configuration of the Management interface:
1. In the Network Configuration screen, type 4 to open the Network Connections screen.
2. Type 2 to select Configure connection. The Choose a connection to configure screen opens.
The Network Connections screen opens.
The image above is from VSX-1 9070. The screen is slightly different for VSX-1 3070.
Chapter 2 Installation and Configuration 25
Initial Configuration
3. Type the number corresponding to Mgmt on VSX-1 9070 or Internal on VSX-1 3070. This number may change according to your hardware configuration but is 13 in the example above.
4. Type 1 to Change IP settings and then enter an IP address, network mask, and broadcast address for the Management interface.
5. Return to the Network Configuration menu by typing e twice.
The Choose Mgmt/Internal item to configure screen opens.
26
6. Type 5 to select Routing. The Routing screen opens.
7. Type 1 to select Set Default Gateway and enter the default gateway according to your network configuration.
8. Return to the Network Configuration menu by typing e and type n to continue to the time and date configuration menu.
Setting Network and Time/Date Properties
To set the system time and date:
1. In the Time and Date Configuration screen, set the time zone, date, and local time according to the on-screen
Initial Configuration
2. Type n again to proceed to the Check Point Configuration
3. Read and type y to accept the license agreement and
instructions. Type n to continue.
Program.
proceed to the clustering options.
Selecting Cluster Options
To enable VSX clustering features:
1. The question, "Would you like to install a Check Point clustering product?” appears.
If you want to enable VSX clustering, type y.
If you do not want to install cluster functionality, type
n and proceed to “Completing the Configuration” on
page 28.
2. You are asked if you want to enable the Per Virtual System
State. This feature is required for the Virtual System Load Sharing (VSLS) and Per Virtual System High Availability
features.
Chapter 2 Installation and Configuration 27
Initial Configuration
Typ e y when prompted if you want to enable this
feature.
If you do not intend to use these features, type n. If you respond with n, a prompt appears, offering an option to enable the Active/Standby Bridge Mode. Type
y to enable this feature or n to disable.
Completing the Configuration
To perform the final configuration steps and reboot the appliance:
1. Indicate whether or not you want to add a license at this time. In most cases, you should add licenses later using the GUI client.
2. Enter and confirm a SIC activation key. You will need to provide this key in order to establish SIC trust between the gateway and the management server.
3. Optionally, follow the on-screen instructions to enable ClusterXL for Active/Standby Bridge Mode.
4. Type y to reboot the appliance.
To use VSX, you must configure and install a security policy. See the VSX NGX R65 Administration Guide for more information.
To add URL Filtering capabilities to your VSX-1 appliance, see the Web Filtering for VSX NGX R65 Hotfix.
28
VSX Appliance Recovery
VSX comes preloaded on your VSX-1 appliance. If, for any reason, you need to reinstall VSX on the appliance, follow the following procedure.
1. Connect to the appliance console using the designated cord received in your shipping carton (RJ45/D-subminiature cable) and connect to the console using Terminal Emulation software, such as HyperTerminal.
2. Load the Installation CD that you received in your shipping carton into a portable USB CD-ROM/DVD-ROM drive.
3. Connect the portable CD-ROM/DVD-ROM drive to the appliance's USB socket.
VSX Appliance Recovery
4. Power-On your appliance.
5. Once the appliance boots from the CDROM/DVD drive, the following welcome screen opens:
Press Enter to start the installation.
6. The installation automatically installs all required components and the progress of each stage is shown.
7. When you see the message, “You may safely reboot your system,” reboot the appliance manually using the master power button. Turn the appliance off and disconnect the USB CD-ROM/DVD-ROM. After several seconds, press the master power button to turn on the appliance again.
Chapter 2 Installation and Configuration 29
VSX Appliance Recovery
To install the existing security policy and configuration on the recovered gateway or cluster members:
1. From the command line of the SmartCenter server or MDS run:
vsx_util reconfigure
2. Enter the following information when prompted:
a. SmartCenter server or primary CMA IP address
b. Administrator username and password
c. Gateway or member object name
d. SIC activation key for the recovered gateway or cluster
member
The VSX-1 appliance now contains the security policy and is part of the network configuration.
Note - For more information about the
vsx_util reconfigure
command, see the VPN-1 Power
VSX NGX R65 Administration Guide.
30
Chapter
VSX-1 Hardware
In This Chapter:
Overview page 31
Customer Replaceable Parts page 40
This chapter provides descriptions of the hardware components of the VSX-1 appliance and instructions for installing and removing the hardware.
3
Overview
Front Panel Components page 32
Rear Panel Components page 38
This section discusses the hardware components comprising the VSX-1 appliance.
31
Overview
Front Panel Components
VSX-1 9070 page 33
VSX-1 3070 page 34
Expansion Line Cards page 35
Hard Disk Drives page 37
This section describes the features and components located on the appliance front panel.
32
VSX-1 9070
Table 3-1 VSX-1 9070 Front Panel
Key Description
Overview
1 LCD display screen
2 Management connection port - Ethernet connection
to a remote management workstation
3 Synchronization port - for synchronizing with cluster
members or a high availability peer
4 Console port - for a serial connection to the
appliance using a terminal emulation program such as HyperTerminal.
5 USB ports
6 Screen operation keys
7 Power indicator LED
8 Future expansion slot
9 Expansion line card exp1 (2 or 4 ports)
10 Built in Ethernet ports (Lan1 - Lan8)
11 Expansion line card exp2 (2 or 4 ports)
12 Hard disk drive
Chapter 3 VSX-1 Hardware 33
Overview
VSX-1 3070
Table 3-2 VSX-1 3070 Front Panel
l
Key Description
1 LCD screen
2 Screen operation keys
3 Power indicator LED
4 USB ports
5 Console port - for a serial connection to the
appliance using a terminal emulation program such as HyperTerminal.
6 Internal connection port - Ethernet connection to a
remote management workstation
7 External connection port - Ethernet connection to
connect outside the organization
8 DMZ connection port - Ethernet connection to the
DMZ
9 Sync/Lan1 port- for synchronizing with cluster
members in high availability mode, or Lan1 interface in Gateway mode
10 Built in Ethernet ports (Lan2 - Lan7)
34
Overview
LCD Display Screen
After the appliance has booted up, the LCD panel located on the front of the appliance displays the model of the unit.
The arrow keys scroll the display up and down. Use the ENTER button to make selections. The ESC button is intended for future functionality. All of the buttons on the LCD display are only functional while the count down to the booting process is displayed.
Expansion Line Cards
The VSX-1 9070 appliance contains optional expansion slots that accommodate cold-swappable network line cards. VSX-1 9070 supports two network expansion slots.
or
Chapter 3 VSX-1 Hardware 35
Overview
According to type, each expansion line card contains two or four ports. The following types of expansion line card are currently available:
Table 3-3 Expansion Cards Available for VSX-1 9070
Model Description
CPPWR-ACC-4-1C 1000BaseT line card
CPPWR-ACC-4-1SRF 1GbE Multi-mode SR fiber optic line
card
CPPWR-ACC-4-1LRF 1GbE Single-mode LR fiber optic
line card
CPPWR-ACC-2-10SRF 10GbE Multi-mode SR fiber optic
line card
CPPWR-ACC-2-10LRF 10GbE Single-mode LR fiber optic
line card
36
Overview
Hard Disk Drives
VSX-1 9070 contains two redundant hot-swappable hard disk drives (RAID1).
Figure 3-1 Hard Disk Drives
RAID1 Mirroring
Implemented by a dedicated RAID controller, the VSX-1 9070 model performs RAID1 mirroring across two hard disk drives. Mirror rebuild is automatic.
VSX-1 3070 contains one hard disk drive that is not replaceable.
Chapter 3 VSX-1 Hardware 37
Overview
Rear Panel Components
This section describes components located on the rear panel of the appliance.
Main Power Switch
The main power switch controls power to the entire unit.
Redundant Power Supply Units
Located at the right rear of VSX-1 9070, two hot-swappable power supply units provide built-in power redundancy. Each power supply connects to an electric outlet.
Figure 3-2 Redundant Power Supply Units (VSX-1 9070
only)
When a power supply fails or is not connected to the outlet, an alarm sounds continuously.
38
Overview
Cooling Fans
VSX-1 9070 contains three replaceable cooling fans. Each cooling fan operates independently of the others, providing redundancy in the event of failure.
Figure 3-3 Cooling Fans in VSX-1 9070
Retaining Screws
VSX-1 3070 contains one cooling fan that is not replacable.
Retaining Screws
Chapter 3 VSX-1 Hardware 39
Customer Replaceable Parts
Customer Replaceable Parts
Power Supply page 40
Cooling Fan page 42
Expansion Line Card page 43
Hard Disk Drive page 45
To ensure maximum availability and ease of maintenance, the VSX-1 9070 appliance contains the following customer replaceable parts:
VSX-1 9070
Two power supplies
Three cooling fans
Dual expansion line card slots
Two hard drives
Unless directed to do so by Check Point technical support, customers are prohibited by warranty and support agreements from replacing any parts. Customers are prohibited from opening the VSX-1 appliance case under any circumstances.
Power Supply
This section presents the procedures for removing and installing a power supply unit. VSX-1 9070 contains two redundant power supplies.
40
Customer Replaceable Parts
Figure 3-4 Redundant Power Supply Details
Removing the Power Supply
To remove a power supply unit:
1. If the alarm sounds, press the red alarm button to the right of the power supply. The alarm stops.
2. Remove the power cord.
3. Loosen the retaining screw located above the power socket.
4. Pull the extraction handle to remove the power supply unit.
Note - Use only the extraction handle to remove the power supply unit. To prevent damaging the power supply, do not pull on the retaining screw, power cord clip or any other part of the unit.
Chapter 3 VSX-1 Hardware 41
Customer Replaceable Parts
Installing the Power Supply
To install a replacement power supply:
1. Insert the power supply into its slot and push firmly until it clicks into place.
2. Tighten the retaining screws.
3. Insert the power cord. Verify that the green LED is illuminated.
Cooling Fan
This section presents the procedures for removing and installing a fan unit. VSX-1 9070 contains three cooling fans. It is not necessary to power off the appliance before adding or removing a fan unit.
Figure 3-5 Cooling Fan
42
Customer Replaceable Parts
Removing Cooling Fan Units
To remove a fan unit:
1. Loosen the four retaining screws in the corners of the fan assembly.
2. Gently pull the fan unit out of the appliance.
Installing Cooling Fan Units
To install a fan unit:
1. Insert the fan unit into the appliance. Push firmly until it clicks into place.
2. Tighten the four retaining screws in the corners of the fan assembly.
Expansion Line Card
This section presents the procedures for removing and installing an expansion line card unit. The built-in ethernet ports (Lan1 Lan8) are not customer replaceable. VSX-1 9070 has two expansion line card slots.
Warning - Make certain that you are electromagnetically grounded when performing the following procedures. Static electricity can damage the appliance.
Chapter 3 VSX-1 Hardware 43
Customer Replaceable Parts
Figure 3-6 Expansion Line Card
Removing Expansion Line Cards
To remove an expansion line card:
1. Power off the appliance and remove the power cords from the power supply units.
2. Loosen the retaining screws on either side of the expansion line card.
3. Holding the screws, pull the expansion line card out of the slot.
Installing Expansion Line Cards
To install an expansion line card:
1. Power off the appliance and remove the power cords from the power supply units.
2. Insert the expansion line card into the slot.
3. Push until the card clicks into place.
44
4. Tighten the retaining crews on either side of the expansion line card.
Hard Disk Drive
This section covers installing or removing a hard disk drive.
VSX-1 9070 contains two hot swappable (RAID-1) hard disk drives.
Figure 3-7 Hard Disk Drives
Customer Replaceable Parts
Removing a Hard Disk Drive
To remove a hard disk drive:
1. Using the key supplied in the toolkit, unlock the drive.
2. Slide the release latch toward the left. The extraction handle springs out.
3. Using the extraction handle, remove the drive from the slot.
Chapter 3 VSX-1 Hardware 45
Customer Replaceable Parts
Installing a Hard Disk Drive
To install a hard disk drive:
1. Slide the replacement hard disk drive into the slot.
2. Push the extraction handle until it closes and the drive clicks into place.
3. Using the key supplied in the toolkit, lock the new drive in place.
46
Chapter
Registration and Support
In This Chapter
Registration page 47
Support page 48
Where To From Here? page 48
Registration
4
You must install a VSX-1 appliance license before operation. To obtain a license and register your appliance, please visit:
http://register.checkpoint.com/cpapp
if you are evaluating a VSX-1 appliance, you will have access to a 15-day evaluation license key.
Note - The Management interface (Mgmt on VSX-1 9070 and Internal on VSX-1 3070) MAC address is required to obtain a license.
47
Support
Support
For further information about the VSX-1 appliance, visit:
https://usercenter.checkpoint.com/usercenter/login/cpapp
For technical assistance, contact CheckPoint 24 hours a day, seven days a week at:
+1 972-444-6600 (Americas)
+972 3-611-5100 (International)
or visit:
http://support.checkpoint.com
Where To From Here?
You have now learned the basics that you need to get started. The next step is to obtain more advanced knowledge of your Check Point software.
Check Point documentation elaborates on this information and is available in PDF format on the Check Point CD as well as on the Technical Support website at http://support.checkpoint.com.
Be sure to also use our Online Help when you are working with the Check Point SmartConsole clients.
48
Loading...