Checkline MCT-HS User Manual

NOTES
TABLE OF CONTENTS
2.0 Design of the device .................................................................... 2
3.0 Measuring procedure ................................................................... 3
4.0 Direction of plug in ....................................................................... 4
5.0 Menu level overview .................................................................... 5
6.0 Keypad symbols .......................................................................... 6
7.0 List of calibration curves .............................................................. 6
8.0 Activation of the “super user” function ......................................... 6
9.0 Changing the User level .............................................................. 7
10.0 Measuring value out of range ...................................................... 7
11.0 Transfer saved data to the PC .................................................... 8
12.0 Print saved data .......................................................................... 9
13.0 Changing batteries ...................................................................... 10
14.0 Determination of the material reference moisture ....................... 10
15.0 Exemption from liability ............................................................... 11
16.0 Technical data ............................................................................. 11
17.0 Most common reasons for miss readings .................................... 12
18.0 Warranty ...................................................................................... 13
Electromatic Equipment Co., Inc.
-16-
Electromatic Equipment Co., Inc.
-1-
1.0 CALIBRATION CURVES
Compressed
Measuring
Measuring head
Insertion probe
POWER button
Temperature
Water content
calibration curve
PC interface
Calibration curves Declaration
straw round bal.
Straw round bales
density
range limit
> 130kg/m³ 8,5% - 30%
straw bales Straw bales 100 up to 130kg/m³ 8,5% - 30% straw loose Straw 8,5% - 30% hay round bales hay round bales > 130kg/m³ 8,5% - 25% hay bales hay bales 100 up to 130kg/m³ 8,5% - 25% hay loose Hay 8,5% - 25% cellulose Insulting material 38 – 65kg/m³ 10,0% - 35% Digit Special products 0,0% - 100% Test block
! Only for testing the device with the test block !
Free Calibration curves: There are another 2 empty calibration curves stored in the measurement device. These can be used to add some curves of special materials.
2.0 DESIGN OF THE DEVICE
NOTES
Batteries slot
(flipside)
Electromatic Equipment Co., Inc.
-2-
Changing the
Electromatic Equipment Co., Inc.
-15-
NOTES
3.0 MEASURING PROCEDURE
1. For a correct measurement please ensure that the device has the same temperature than the material you want to measure (+/-3°C). For that reason, let your MCT-HS-PRO adjust to the surrounding temperature of the material for at least half an hour before measuring (protect from direct sunlight!).
2.) Switch on the device: Press the seconds.
3.) To change the calibration curve, please press the
or key.
4.) Plug the probe into the material. The display shows the water content immediately.
5.) Pay attention to the direction of plugging in! (pay attention to the following page!)!
6.) To save the results in the save menu press the (
button). The storage was successful when the number in front of the symbol increased. To reach the store menu please press ( ) until the
appears.
ATTENTION! Risk of injury!
key for 3
Electromatic Equipment Co., Inc.
-14-
Electromatic Equipment Co., Inc.
-3-
4.0 DIRECTION OF PLUG IN
Insert the device into the bale like shown in the picture below. Any other direction of plugging lead to a significant deviation of the measuring results. Pull the unit straight out again. Any mechanical damage due to mishandling is no case of guarantee.
Round bales have to be measured on the face side. Measurements at the bearing surface lead to miss readings.
Rectangle bales have to be measured on the face side. Measurements at the other side can lead to miss readings.
Measuring of loose material
Fix the delivered compression plate like it is shown in the pictures. Switch to the right calibration curve (“straw loose” or “hay loose”) and stab in the material. It is very important that there is a good contact between the material and the plate. These curves should be used before you press the material to bales.
18.0 WARRANTY
Electromatic Equipment Co., Inc. (Electromatic) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect in workmanship or material in the product existing at the time of delivery thereof which manifests itself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at Electromatic’s option, except where unauthorized repair, disassembly, tampering, abuse or misapplication has taken place, as determined by Electromatic. All returns for warranty or non-warranty repairs and/or replacement must be authorized by Electromatic, in advance, with all repacking and shipping expenses to the address below to be borne by the purchaser.
THE FOREGOING WARRANTY’S IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER’S OR SUPPLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. The duration of any implied warranty, including, without limitation, fitness for any particular purpose and merchantability with respect to this product, is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts but, not withstanding, this warranty, in the absence of such limitations, shall extend for one year from the date of invoice.
Electromatic Equipment Co., Inc. 600 Oakland Ave. Cedarhurst, NY 11516 - USA Tel: 1-800-645-7330 / Tel: 516-295-4300 / Fax: 516-295-4399
Every precaution has been taken in the preparation of this manual. Electromatic assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of information contained herein. Any brand or product names mentioned herein are used for identification purposes only, and are trademarks or registered trademarks of their respective holders.
Electromatic Equipment Co., Inc.
-4-
Electromatic Equipment Co., Inc.
-13-
17.0 MOST COMMON REASONS FOR MISS READINGS
Overview main menu
Product temperature out of application range Material below 0°C resp. above +40°C may cause faul ty measurements. The storage of cold material in a warm storage area usually creates condensed water which may lead to major measuring errors.
Discrepancy in temperature between device and material Please ensure that the device and the material under test are being stored at the same temperature (+/- 3°C) before measuring. Protect your measuring device from direct sunlight for a reasonable time period before taking a measurement. A high temperature difference has a negative effect on the stability of the measurement results.
Wrong calibration curve Double check the correct selection of the calibration curve before measuring.
Wet or mouldy material
Frozen measuring material or material containing snow
This leads to a major decrease in accuracy.
Direction of plugging in The Direction of plugging has a great influence on the accuracy. Necessarily follow the instructions according to the beginning of the manual!
Compressed density outside the application range If the compressed density differs from that specified, there may be deviations!
Moving the measuring head after the plug in leads to miss readings!
Water film at the measuring head
After measuring wet material a water film can arise on the sensor head. This could lead to a too high result in the following measurements. After measuring wet material clean both black plastic parts of the measuring head accurately with a dry cloth.
ATTENTION: Risk of injury by measuring head! Keep away from children younger than 16 years!
5.0 MENU LEVEL OVERVIEW
Type selection
Watch the saved data (logs) Save new value (log) Power off (3 sec.)
Next calibration curve Previous calibration curve Power off (3 sec.)
Switch upper Switch lower Open this menu / Enter
Main menu
Edit Logs
Manual Logs Clear Logs
Print Logs
Last Log All Logs Clear Logs
Send Logs
Manual Logs Clear Logs
Options
Date / Time Log Time Language Unlock
°C / °F o Userlevel BL On
Time Auto Off Time o Online Send o Online Print Materialcalib. Password Reset
Electromatic Equipment Co., Inc.
-12-
Electromatic Equipment Co., Inc.
-5-
6.0 KEYPAD SYMBOLS
Measuring window:
Rolling Menu Power ON / OFF Switch upper Switch lower Save Hold
Watch the saved data
Menu:
Enter Switch upper Switch lower Exit
Enter numbers
Enter letters Next or right Left Yes No Shift
OK
7.0 LIST OF CALIBRATION CURVES
Pressing the or key in the measuring window for at least 3 seconds and a list with all available sorts will appear. Select your sort by pressing with the
key. The measurement will continue
or and confirm it
automatically.
8.0 ACTIVATION OF THE “SUPER USER” FUNCTION
2 times - Options – Unlock Enter the 4-digit password by using the button (standard is the 4-digit serial number) and confirm by pressing the
button.
15.0 EXEMPTION FROM LIABILITY
For miss-readings and wrong measurements and of this resulting damage we refuse any liability.
This is a device for quick determination of moisture. The moisture depends on multiple conditions and multiple materials. Therefore we recommend a plausibility check of the measuring results.
Each device includes a serial number and the guarantee stamp. If those are broken, no claims for guarantee can be made. In case of a faulty device, please contact Electromatic.
16.0 TECHNICAL DATA
Resolution of the display 0,1% water content 0,5°C temperature
Measuring range 8 to 30 % (60%) Operation temperature 0°C to 40°C Temperature measuring range -20°C to 120°C (only me asuring head) Storage temperature -20°C to 60°C Temperature compensation automatically Power supply 4 pcs. 1,5 Volt AA Alkaline batteries
Auto Switch Off after approx. 6 minutes Current consumption 55 mA (with light) Display 128 x 64 matrix display, lighted Dimensions 740 x 65 x 40 mm Weight approx. 450g (incl. batteries) Degree of protection IP 40 Scope of supply MCT-HS-PRO, wooden case
Software LogMemorizer USB cable
(for approx. 1000 measurements)
4 x 1,5Volt AA Alkaline batteries Compression plate
Electromatic Equipment Co., Inc.
-6-
Electromatic Equipment Co., Inc.
-11-
Mn
13.0 CHANGING BATTERIES
If the batteries are empty, please change them as follows: 1 Press with your finger onto the arrow of the battery cap
and pull it back.
2. Remove the empty batteries.
3. Put four new 1,5 Volt AA Alkaline batteries into the device. Make sure that the position of the battery poles is correct.
4. Press down the batteries and close the cap.
If the battery symbol appears in the measuring window resp. if a critical charge of battery is shown in the status, the batteries have to be changed IMMEDIATELY. If you do not use your MCT-HS-PRO device for a longer period, remove the batteries. For eventual resulting damages we cannot provide any warranty.
14.0 DETERMINATION OF THE MATERIAL REFERENCE MOISTURE
The MCT-HS-PRO determines the water content, that means that it calculates the moisture referred to the total mass:
F
=
MtMn
100% ×
Mn: Mass with average moisture content M
: Mass of the dried sample
t
%F: Calculated absolute moisture
(water content) (according to norm: CEN/TS 14774)
9.0 CHANGING THE USER LEVEL
Changing from advanced user to single user: Make sure that you have activated the “super user” functions according to the
instructions above. Afterwards change to the menu and choose „Options“. In the submenu please select „o Userlevel“ (2 times - Options – o Userlevel) Confirm by pressing the button. Now the single user is activated.
Changing from single user to advanced user: Keep both the buttons
MCT-HS-PRO automatically starts the main menu. Activate the the “super user” functions according to the instructions above.
Navigate to “Options – o Userlevel” and confirm by pressing the button.
10.0 MEASURING VALUE OUT OF RANGE
If the measure value is blinking, the valid measuring range is exceeded (limits see sectien 1.0). In this case the accuracy will be decreasing.
and pressed directly after switching on the device. Your
Electromatic Equipment Co., Inc.
-10-
Electromatic Equipment Co., Inc.
-7-
11.0 TRANSFER SAVED DATA TO THE PC
To send your saved logs to the PC, connect the MCT-HS­PRO device to your PC using the USB cable that was delivered with your device. Carefully loose the protection cap on your MCT-HS-PRO and plug in the USB mini B connector. The bigger connector has to be connected to a USB slot on your PC. Start the LogMemorizer software on your PC and switch on your MCT-HS-PRO.
The data transfer can be started on your MCT-HS-PRO or on the software.
Starting the data transfer on the MCT-HS-PRO: Press the key until you reach the menu (see image on
the right). Then choose „Send Logs“ and confirm by pressing the confirm with
key. Now choose „Manual Logs“ and
again. All saved logs will be sent to your
PC.
Starting the data transfer on your PC: Press the button „remote control“ in the LogMemorizer
software. A drop-down menu with several options opens (see image below).
For transferring the data you can select „Import last manual log“ (the last saved measuring series is transferred) or „Import all manual logs“ (all saved logs are transferred).
If you click on one of these menu items, the transfer starts immediately.
For the basic adjustments of the software please look through the instructions on the LogMemorizer CD.
12.0 PRINT SAVED DATA
To print your saved data, connect the device to the printer using the printer cable that was delivered with your device. Carefully loose the protection cap on the MCT­HS-PRO. At first plug in the side of the connector with the close plastic casing at the MCT-HS-PRO. Then switch on the device.
Not till then the other side of the cable has to be plugged in at the printer. Switch on the printer by pressing . Now the green LED is blinking. If it does not blink, please change the batteries and try again.
Press the the menu (see image on the right). Choose „Print Logs“ and confirm by pressing
Now you can select if you want to print the last saved measuring series or all saved measuring series (logs).
Confirm by pressing printed out now.
To save paper, please think of clearing the data storage regularly.
Online Print and Online Send
Your device supports the function “Online Print” and “Online Send”, this can be activated in the menu „Options“. If an option is active, every newly recorded log will immediately be printed or transferred to the PC after
pressing
button at your MCT-HS-PRO until you reach
.
again. The selected logs are
key.
Electromatic Equipment Co., Inc.
-8-
Electromatic Equipment Co., Inc.
-9-
STRAW AND HAY MOISTURE METER
MCT-HS-PRO
OPERATING INSTRUCTIONS