Checkline LS-REGSENSOR User Manual

Mark•Eye™ SETUP INSTRUCTIONS
Optimized for the Detection of Registration Marks on Translucent or Transparent Web Materials
Web color/background is Lighter than the mark (See Figure A)
Position the detection zone of the sensor between the registration marks and press the “LIGHTER
THAN MARK” button to initiate the AUTOSET™ routine.
The green LED AUTOSET™ indicator will rapidly blink until the proper setting is achieved. The red LED output indicator and output transistors will turn “OFF”. When the mark passes through the detection zone, the red LED output indicator and output transistors will turn “ON” for the duration of time that the mark is in view.
not penetrate through the light colored background. If this condition occurs during a light colored background AUTOSET™ routine, both the red and green LEDs will flash twice.
Web color/background is Darker than the mark (See Figure B)
Position the detection zone of the sensor between the registration marks and press the “DARKER
THAN MARK” button to initiate the AUTOSET™ routine.
The green LED AUTOSET™ indicator will rapidly blink until the proper setting is achieved. The red LED output indicator and output transistors will turn “OFF”. When the mark passes through the detection zone, the red LED output indicator and output transistors will turn “ON” for the duration of time that the mark is in view.
Inverting the Output
Depress both buttons for 3 seconds.
Pulse Stretcher
The Markeye sensor can be programmed to provide a 15-millisecond pulse stretcher timing function.
To determine if the pulse stretcher is enabled, during initial power-up the AUTOSET™ LED will rapidly flash twice, verifying that the pulse stretcher is enabled.
Enabling or Disabling the Pulse Stretcher
To toggle the status of the pulse stretcher to the opposite state:
1. Remove power from the sensor.
2. Depress and hold both buttons simultaneously and apply power.
3. After applying power, note that the AUTOSET™ LED will flash; release both buttons.
4. Depress the “LIGHTER THAN MARK” to toggle the pulse stretcher to the opposite state.
5. Remove power from the sensor.
6. Whenever power is applied, the pulse stretcher will be enabled and the AUTOSET™ LED will flash twice. The pulse stretcher can be disabled when these steps are repeated.
NOTE: The factory’s default setting for the pulse stretcher is the disabled state.
Dark Mark on a Light Web (Figure A) Light Mark on a Dark Web (Figure B)
SPECIFICATIONS
CHECK•LINE®–PRECISION QUALITY CONTROL INSTRUMENTS
Electromatic Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, N Y 11516 —USA
Tel: (800) 645-4330 (USA & Canada) Tel: (516) 295-4300 Fax: (516) 295-4399
Email: info@checkline.com Website: www. checkline.com
SUPPLY VOLTAGE
10 to 30 VDC
Polarity Protected
CURRENT REQUIREMENTS
45 milliamps (exclusive of load)
OUTPUT TRANSISTORS
(1) NPN and (1) PNP output transistors
Sensor outputs can sink or source up to 150 milliamps
(current limit)
All outputs are continuously short-circuit protected
REMOTE AUTOSET™ INPUT
Opto isolated momentary sinking input (10 milliamps)
RESPONSE TIME
Light state response = 100 microseconds
Dark state response = 100 microseconds
LED LIGHT SOURCE
Pulse modulated high intensity white LED
PUSHBUTTON CONTROL
One pushbutton set-up
Automatic set-up routines based on web opacity
Simultaneously pushing both buttons inverts the output
On power-up, simultaneously pushing both buttons enables
the program mode, allowing the pulse stretcher to be enabled or disabled
Sensor Selection Guide
Model
MEWL White LED, 5-conductor cable MEWLC White LED, 5-
DIMENSIONS
HYSTERESIS
Minimal hysteresis promotes detection of low contrast
registration marks
LIGHT IMMUNITY
Responds to sensor’s pulse modulated light source …
immune to most ambient light
INDICATORS
Green AUTOSET™ LED flashes when AUTOSET™ routine is
activated and stays illuminated when AUTOSET™ is completed
Red Output LED illuminates when sensor’s output
transistors are “ON”
On power-up, the AUTOSET™ LED flashes twice when
the pulse stretcher is enabled
AMBIENT TEMPERATURE
- 40°C to 70°C (- 40°F to 158°F)
RUGGED CONSTRUCTION
Chemical resistance to harsh cleaners, such as
detergents, alcohols, and ketones
Waterproof ratings: NEMA 4 and IP66
Conforms to heavy industry grade CE and UL requirements
SELECTABLE PULSE STRETCHER
Provides a minimum of 10 milliseconds output duration
Description
pin
micro
connector on a 6” pigtail
Product subject to change without notice.
Cable Selection Guide (5 Wire)
Model
GSEC-2MU 6.5 ft. (2.0m) Low Cost, Unshielded GSEC-5MU 16 ft. (5.0m) Low Cost, Unshielded GSEC-6 6 ft. (1.8m) Shielded Cable GSEC-15 15 ft. (4.6m) Shielded Cable GPSEC-15 15 ft. (4.6m) Shielded Cable
Micro Cable (M12) Description