Checkline LS-GAPSENSOR User Manual

LABEL•EYE AUTOSET™
Set-Up Instructions
Normal Label Opacity Autoset™ Button
This category includes most paper or melallized film labels adhering to paper or transparent backing materials. To implement the one button Autoset routine, utilize the external alignment guides to position the gap between labels in line with the dot shown in the center of the detection zone. Then push the Autoset button marked "Normal".
An alternative set up procedure would be to remove a label and the push the "Normal" Autoset button.
On rare occasions, when the light is unable to penetrate the backing materials, both the red and green led indicators will blink four times. When this indication occurs, the sensor will be unable to detect the presence of the labels.
Translucent Label Opacity Autoset™ Button
This category includes translucent labels adhering to transparent backing materials.
This sensor cannot detect transparent labels adhering to transparent backing materials. The question is how close to transparent can the translucent labels be and still be detected? There is no definitive answer to that question. To determine if detection of a translucent label adhering to transparent backing material is to try the following Autoset procedure. First utilize the external alignment guides to position the gap between labels in line with the dot shown in the center of the detection zone. Then push the Autoset button marked "Translucent". The next step is to move the web so that the translucent label goes in and out of the light beam. If detection is possible, the red led output indicator should go on when the label passes through the detection zone.
INVERT OUTPUT: The status of the red led and output transistors can be inverted by pressing both buttons simultaneously. When the output status has been inverted, the red led and the output transistors will turn off when the label comes into view.
SPECIFICATIONS
CHECK•LINE®–PRECISION QUALITY C ONTROL I NSTRUMENTS
Electromatic Equipment Co., Inc.
600 Oakland Ave. Cedarhurst, N Y 11516 —USA
Tel: (800) 645-4330 (USA & Canada) Tel: (516) 295-4300 Fax: (516) 295-4399
Email: info@checkline.com Website: www.checkline.com
SUPPLY VOLTAGE
10 to 30 VDC
Polarity Protected
CURRENT REQUIREMENTS
45 milliamps (exclusive of load)
OUTPUT TRANSISTORS
(1) NPN and (1) PNP output transistors
Sensor outputs can sink or source up to 150 milliamps
(current limit)
All outputs are continuously short circuit protected
RESPONSE TIME
Light state response = 100 microseconds
Dark state response = 100 microseconds
LED LIGHT SOURCE
High intensity red LED
Pulse modulated
PUSH BUTTON CONTROL
Automatic set-up routines based on web opacity
One push button set-up
Simultaneously pushing both buttons inverts the output
Model Numbers:
Label•Eye Description
LER Red LED, 4 conductor 6 ft. cable LERC Red LED, 4-pin Nano connector
DIMENSIONS
HYSTERESIS
Minimal hysteresis promotes the detection between the
backing material and the label depending on the settings
LIGHT IMMUNITY
Responds to sensor’s pulsed modulated light source …
immune to most ambient light
INDICATORS
Green LED flashes when Autoset™ routine is activated
and stays illuminated when Autoset™ is completed
Red LED illuminates when sensors output transistors
are “ON”. Note: The status of the output transistors can be inverted by pushing both buttons simultaneously
AMBIENT TEMPERATURE
–40°C to 70°C (-40°F to 158°F)
RUGGED CONSTRUCTION
Chemical resistance to harsh cleaners such as
detergents, alcohols, and ketones
Waterproof, ratings: NEMA 2
Conforms to heavy industry grade CE and UL requirements
Product subject to change without notice.
Nano Cable (M8) Selection Guide
P/N Length Thread Coupling
GEC-6 6 ft. (1.8m) Straight Female GEC-15 15 ft. (4.6m) Straight Female RGEC-6 6 ft. (1.8m) 90° Female RGEC-15 15 ft. (4.6m) 90° Female
Loading...