ADA COMPLIANT ACCESS
ADA ACCESS COMPLIANT
FOR USE WITH SELECT LINEBACKER, GUARD DOG, AND SIDE-KICK CABLE PROTECTORS*
ASSEMBLY:
• Modular, 36-inch wide ramps can be attached to single or multiple cable
protectors in series to provide an ADA compliant access ramp of any length.
• Side rails provide required edge protection to prevent wheelchairs from rolling off
ramp sides.
• ADA ramps and rails attach only to the existing cable protector ramps and do not
interfere with the operation of the cable protector lid and accessibility of the
electrical cables.
• Lightweight modular design allows for quick and easy assembly by one person.
• Gentle slope and slip resistant ramps provide an excellent crossing point for carts
and vehicles with small wheels.
COMPONENTS
Shown with Guard Dog Cable Protectors
HEAVY DUTY
RAMPS AND RAILS
ADA RAIL CAN BE
USED IF REQUIRED.
RAMP
CABLE PROTECTOR
RAMP
CABLE PROTECTOR
RAMP
Modular components
allow you to create an
ADA system of any length
LOAD CAPACITY:
CROSS-GUARD ADA compliant access ramp load supporting capabilities could
vary depending on type of vehicle and temperature. Suitability must be verified
by testing under actual conditions.
ADA SYSTEMS
Ramps
MAXIMUM LOAD PER TIRE
70˚F (21˚C)
10,500 lbs. (4,763 kg)
OPERATING TEMPERATURE:
-40˚F to 120˚F (-40˚C to 48˚C)
CHEMICAL RESISTANCE:
Tested for compatibility with common motor oils, gasoline and
diesel fuel. Limited resistance to brake fluids and other chemicals.
MAXIMUM LOAD PER AXLE
70˚F (21˚C)
21,000 lbs. (9,526 kg)
*
WARNING!
Cross-Guard ramps and rails are compatible only
with Linebacker and Guard Dog cable protectors as
specified. Cross-Guard ramps are also compatible
with Side-Kick cable protector expanders. Improper
use with other cable protector brands may result
in product failure or injury.
ADA
COMPLIANT
RAMP
RAIL BARRIERS AVAILABLE IF NEEDED
For additional stability, it
is recommended that two 75
pound weights (for a total
weight of 150 pounds) be placed in
the recessed areas of each Rail Barrier.
MATERIAL:
UV-stabilized polyurethane elastomer
#ZIS-CPRP
Ver: 2/11

HEAVY DUTY
ADA COMPLIANT ACCESS
ADA ACCESS COMPLIANT
RAMPS AND RAILS
FOR USE WITH SELECT LINEBACKER, GUARD DOG, AND SIDE-KICK CABLE PROTECTORS*
INSTALLATION INSTRUCTIONS CAUTION MISUSE CAN CAUSE INJURY
1. Position as many modular interlocking lineal cable
protectors (as specified above) as required for your
particular application on firm surface.
2. Single CROSS-GUARD ADA ramps or multiple CROSSGUARD ADA ramps in series can be added anywhere
within the run length of the cable protection system.
3. Each CROSS-GUARD ADA ramp is connected to a lineal
cable protector with two (2) ADA ramp connectors.
4. Position an ADA ramp connector under each lineal cable
protector in four (4) locations (2 on each side of protector)
by locating the two (2) notched areas at the bottom edge
of the cable protector ramp.
5. Slightly lift the bottom ramp edge of the cable protector
at the notched location and slide the large block end of
the ADA ramp connector under the cable protector ramp
and into the corresponding block recess.
6. Position all connectors on one side of the cable
protectors in series before repeating this procedure on the
opposite side.
7. Align the top and side edge of each ADA ramp with the
top and side edge of the cable protector ramp and lower
the ADA ramp down onto the exposed male pin on the
ADA ramp connector. ADA ramps in series are also
connected to each other by the male/female 'T' connectors
molded into each ADA ramp.
8. Complete the ADA compliant installation by attaching
the side rails to the ADA ramps on each end of the single
or multiple cable protectors with ADA ramps in series.
9. Rails are attached by using the male/female 'T'
connectors molded into each ADA ramp.
10. Optional end caps can be added to the system to
provide gradual taper to the ground or floor. The end caps
connect only to the lineal cable protector and not to the
CROSS-GUARD ADA ramps.
• DO NOT use as work surface. NO CUTTING, NO
DRILLING, NO HAMMERING.
• Use with momentary loads only, DO NOT place ladders,
scaffolds, or any type of structure on the system.
• Avoid concentrated loads.
• Use only on a stable surface. Inclined surfaces, slippery
surfaces and broken ground can cause injury.
• This system can be a trip hazard to pedestrian traffic if
they are unaware of its presence.
• Keep the ADA ramps and rails clean and bright.
• Load-supporting capacity varies by type of loading
conditions and environmental conditions. The load
capacity decreases in warm environments. Test before
use and inspect periodically.
• Polyurethane is attacked by some chemicals. Always test
a small amount for chemical compatibility before using
and follow maintenance procedure.
• Vehicular traffic must pass over this system slowly and
with caution.
• Test installation for intended use.
• Periodically inspect installation.
• Store in a clean dry area.
• Inspect system for damage and replace it if damaged.
Remove any foreign materials, solids and liquids. Keep
clean by using a detergent and water solution.
*
WARNING!
Cross-Guard ramps and rails are compatible only
with Linebacker and Guard Dog cable protectors as
specified. Cross-Guard ramps are also compatible
with Side-Kick cable protector expanders. Improper
use with other cable protector brands may result
in product failure or injury.
MAINTENANCE
#ZIS-CPRP
Ver: 2/11
www.checkersindustrial.com
620 COMPTON ST • BROOMFIELD, CO 80020 • PH: 720-890-1187 • FAX: 720-890-1191 • TOLL FREE: 800-438-9336