CHAUVIN ARNOUX C. A 8220, C. A 8230 User Manual

Measurement of all powers
C.A 8220 C.A 8230
Measurement of very weak and very strong currents
Phase shift analysis
Measurement of engine start-up current
Simultaneous access to all measurement modes
Electric
engine
maintenance
Electrical network analysis
POWER
ANALYZERS
C.A 8230
C.A 8230
SINGLE-PHASE POWER AND QUALITY ANALYZER
The C.A 8230 is designed for tradesmen and installers working in the construction industry and maintenance departments. The broad range of measurements it provides also makes it ideal for technical and technological teaching.
Extremely easy to use, it is suitable for testing electrical installations, especially if they are equipped with systems based on power electronics. Suitable for use on the ground, it can also be used on a tabletop, thanks to its retractable support.
User-friendly, it has a large graphic screen and automatically recognises the type of sensor connected.
Voltage & current:
From measurement of the real effective instant display of AC+DC at the period to peak values and overall harmonics rates, the instrument also provides instant display of the waveform. Measurement of short term Flicker is also available.
Complete analysis of power and energy:
In single-phase and balanced three-phase, all necessary and useful measurements enable the user to simply obtain a complete analysis of power and energy.
Harmonics up to order 50:
The C.A 8230 enables the various values to be measured up to order 50 RMS value, fundamental %, mini/maxi in single-phase only. Additional advantage: the expert mode enables direction of harmonics to be determined.
Recording period up to several days:
All values measured by the instrument can be recorded over a period of up to several days. The Inrush mode allows us to analyse and display at engine start-up signal period.
Personalised setting of alarms:
Alarms can be entirely set by the user and enable each event to be captured.
FOR THE C.A 8230 & C.A 8220 (ALSO COMPATIBLE WITH THE QUALISTAR AND OTHER CHAUVIN ARNOUX PRODUCTS)
DATAVIEWER SOFTWARE
DATAVIEWER SOFTWARE
Screenshots
Dataviewer Software, it greatly increases the instrument’s potential in terms of its configuration, and recovery and processing of data on a PC.
Recording: histogram or curve representations,
average value of numerous parameters according to time.
Management & log of measurement campaigns
Report printing
MAIN MEASUREMENTS
MAIN MEASUREMENTS
1
2
Geared firmly towards electrical engineering and testing of rotating machines, the C.A 8220 is designed for maintenance and testing teams.
Equipped with a liquid crystal segment screen, compact and shockproof, its user interface ergonomics make it easy and pleasant to handle via intuitive use.
Just like the C.A 8230, the C.A 8220 makes it possible to obtain an instant image of the main characteristics of a single-phase or a balanced three-phase network.
In addition, it measures all features necessary for testing rotating machines.
Accurate, thanks to a broad range of sensors, it covers measurements from several milliamps to several kilo amps.
C.A 8220
C.A 8220
THE ENGINE MAINTENANCE AND POWER ANALYZER
Rotation speed: For predictive maintenance, it
is necessary to regularly test rotation speed on rotating machines. The C.A 8220, an all-in-
one instrument, meets this requirement simply and effectively.
Temperature: Nowadays rotating engines and
machines are equipped with temperature probes that are easily accessible on a terminal board. By simply connecting the C.A 8220 to
this terminal board, it is possible to directly measure the engine’s internal temperature.
FOR THE C.A 8220 ONLY
PAT SOFTWARE
PAT SOFTWARE
The C.A 8220 comes with PAT (Power Analyzer Transfer) software, designed for processing measurements on a PC (display, analyses, etc). This software is available solely on our Website, where it can be downloaded free of charge.
>> Voltage range from 6 VRMS to 600 VRMS AC+DC ±(0.5%+2pts) >> AC current range from 5mA to 6500 A ±(0.5%+1pts) >> DC current range from 1 A to 1700 A ±(1%+1pts) >>
Mini, Maxi, Avge., Peak values (+ and -), CF
Ye s
>> Fundamental frequency from 40 Hz to 70 Hz >> Screen Colour 1/4 VGA LCD Backlit 173-segment LCD >>
Single-phase and three-phase balanced
Ye s
>> W, VA, var powers, DF, THD, Cos
ϕϕ
Ye s
>> varh and VAh energy Ye s >> Harmonics (IEC 1000-4-7) Up to 50thorder >> Recordings up to several days >> Alarms 4096 >> Flicker PST (IEC 1000-4-15) Ye s >> Engine rotation speed from 6 RPM to 120 kRPM ±(0.5%) >> Temperature (Pt100) from – 200°C to 850°C ±(1%+10pts) >> Resistance (coiling) from 0.0 to 2000 ±(0.5%+1Ω)
>> Phase rotation
Yes,
with display of phase order in three-phase
>> Measurement storage Ye s >> Use
• Ambient temperature 23°C ±3K
• Moisture content (relative) (45% ; 75%)
>> Protection factor IP54 >> RS232 Port Ye s >> IEC 61010-1 600 V, Cat. III >> Power Batteries, autonomy up to 40 hours Batteries (6 x AA) >> Weight 880 g (with accumulators) 840 g (with batteries) >>Dimensions 211 x 108 x 60 mm
ACCESSORIES:
TO ORDER COMPOSITION
YOUR DISTRIBUTOR
C.A 8230 analyzer only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1606.30
C.A 8230 analyzer with MN93A current sensor (5 mA to 120 A) . . . . . . . . . . . . . . . . . . . . . . P01.1606.31
C.A 8230 analyzer with flexible Ampflex 450 current sensor (6500A) . . . . . . . . . . . . . . . P01.1606.32
C.A 8220 analyzer only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1606.20
C.A 8220 analyzer with MN93A current sensor (5 mA to 120 A) . . . . . . . . . . . . . . . . . . . . . . P01.1606.21
C.A 8220 analyzer with flexible Ampflex 450 current sensor (6500A) . . . . . . . . . . . . . . . P01.1606.22
P01.1606.30: 1 C.A 8230 instrument supplied with 1 carrying case, 6 mounted 1.2 V accumulators, 1 red banana lead (straight-straight), 1 black banana lead (straight-straight), 2 x 4-mm test probes (1 red, 1 black), 2 alligator clamps (1 red, 1 black), 1 mains adaptor, 1 RS232/USB optical cable and Dataviewer® software pack
P01.1606.20: 1 C.A 8220 instrument supplied with 6 mounted AA bat­teries, 1 red banana lead (straight-straight), 1 black banana lead (straight-straight), 2 x 4-mm test probes (1 red, 1 black), 2 alligator clamps (1 red, 1 black), 1 RS232/USB optical cable
906 211 137 - Ed.01 • 05/2006 • Non contractual document. Confirm specifications before ordering.
4-mm red and black test probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1018.55
Red and black alligator clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1018.48
4-mm red and black banana/banana lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1018.48
MN93A BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.2950.91
MN93 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1204.25
A 193 Ampflex, 450 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1205.26
A 193 Ampflex, 800 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1205.31
PAC93 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1200.79
C193 BK clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P01.1203.23
TECHNICAL FEATURES
TECHNICAL FEATURES
FRANCE Chauvin Arnoux
190, rue Championnet 75876 PARIS Cedex 18 Tel: +33 1 44 85 44 85 Fax: +33 1 46 27 73 89 info@chauvin-arnoux.fr www.chauvin-arnoux.fr
UNITED KINGDOM Chauvin Arnoux Ltd
Waldeck House - Waldeck Road MAIDENHEAD SL6 8BR Tel: +44 1628 788 888 Fax: +44 1628 628 099 info@chauvin-arnoux.co.uk www.chauvin-arnoux.co.uk
MIDDLE EAST Chauvin Arnoux Middle East
P.O. BOX 60-154 1241 2020 JAL EL DIB (Beyrouth) Tel: +961 1 890 425 Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com
Loading...