The Ovation FD-105WW User Manual includes a description, safety precautions, installation,
programming, operation and maintenance instructions for the Ovation FD-105WW.
Trademarks
CHAUVET, the Chauvet logo and Ovation FD-105WW are registered trademarks or trademarks of
Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries.
Other company and product names and logos referred to herein may be trademarks of their respective
companies.
Copyright Notice
The works of authorship contained in this manual, including, but not limited to, all design, text and images
are owned by Chauvet.
Electronically published by Chauvet in the United States of America.
Manual Use
Chauvet authorizes its customers to download and print this manual for professional information purposes
only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this
manual or its content for any other purpose without written consent from Chauvet.
Document Printing
For best results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. If using A4
paper (210 x 297 mm), configure the printer to scale the content accordingly.
Intended Audience
Any person installing, operating, and/or maintaining this product should completely read through the guide
that shipped with the product, as well as this manual, before installing, operating, or maintaining this
product.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However,
Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss,
damage or disruption caused by any errors or omissions in this document, whether such errors or
omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the
content of this document without any obligation to notify any person or company of such revision, however,
Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest
version from www.chauvetprofessional.com
.
Document Revision
This Ovation FD-105WW User Manual is the 2nd edition of this document. Go to
www.chauvetprofessional.com
for the latest version.
Ovation FD-105WW User Manual Rev. 2
Page 3
Table of Contents
TABLE OF CONTENTS
1. Before You Begin ....................................................................... 1
What Is Included ........................................................................................... 1
Contact Us .................................................................................. 18
ii
Ovation FD-105WW User Manual Rev. 2
Page 5
BEFORE YOU BEGIN
1. Before You Begin
What Is Included
•Ovation FD-105WW
•Neutrik® powerCON® Power Cord
Claims
Carefully unpack the product immediately and check the container to make sure all the parts are in the
package and are in good condition.
If the box or the contents (the product and included accessories) appear damaged from shipping, or show
signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier
immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed
damage, file a claim with Chauvet within 7 days of delivery.
Manual Conventions
ConventionMeaning
1–512A range of values
50/60A set of values of which only one can be chosen
<SET>A button on the product’s control panel
SettingsA product function or a menu option
Symbols
•Gel Frame (6.25 in/158mm accessories)
•Quick Reference Guide
SymbolMeaning
Electrical warning. Not following these instructions may cause electrical damage to
the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these
instructions may make the product not work, cause damage to the product, or cause
harm to the operator.
Important installation or configuration information. The product may not function
correctly if this information is not used.
Useful information.
Any reference to power connections in this manual assumes the use of Neutrik®
powerCON® cables.
The term “DMX” used throughout this manual refers to the USITT DMX512-A
digital data transmission protocol.
Ovation FD-105WW User Manual Rev. 2
Page 1 of 18
Page 6
BEFORE YOU BEGIN
Safety Notes
Read all the following safety notes before working with this product. These notes contain important
information about the installation, usage, and maintenance of this product.
This product contains no user-serviceable parts. Any reference to servicing in
this User Manual will only apply to properly trained, certified technicians. Do not
open the housing or attempt any repairs.
Proper installation of this product must meet all applicable local codes and
regulations.
Personal Safety
•Avoid direct eye exposure to the light source while the product is on.
•Always disconnect the product from the power source before cleaning or replacing the fuse.
•Always connect the product to a grounded circuit to avoid the risk of electrocution.
•Do not touch the product’s housing when operating because it may be very hot.
Mounting and Rigging
•This product is not intended for permanent installation.
•This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to
rain or moisture. (IP20)
•CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to
warm humid ballroom) condensation may form on the internal electronics of the product. To avoid
causing a failure, allow product to fully acclimate to the surrounding environment before connecting
it to power.
•Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent
surfaces.
•Make sure there are no flammable materials close to this product while it is operating.
•When hanging this product, always secure to a fastening device using a safety cable.
•Never carry the product by the power cord.
Power and Wiring
•Make sure the power cord is not crimped or damaged.
•Always make sure you are connecting this product to the proper voltage in accordance with the
specifications in this manual or on the product’s specification label.
•To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
•Make sure to replace the fuse with another of the same type and rating.
•Never disconnect this product by pulling or tugging on the power cable.
Operation
•Do not operate this product if there is damage on the housing, lenses, or cables. Have the damaged
parts replaced by an authorized technician at once.
•Do not cover the ventilation slots when operating to avoid internal overheating.
•The maximum ambient temperature is 113 °F (45 °C). Do not operate the product at higher temperatures.
•In the event of a serious operation problem, stop using this product immediately!
If your Chauvet product requires service, contact Chauvet Technical Support.
Expected LED Lifespan
LEDs gradually decline in brightness over time, primarily because of heat. LEDs that are arranged in
clusters experience higher operating temperatures than single LEDs. For this reason, operating clustered
LEDs at their fullest intensity significantly reduces the LEDs’ lifespan. Under normal conditions, this
lifespan is 40,000 to 50,000 hours. If extending this lifespan is vital, lower the operating temperature by
improving the ventilation around the product, thus reducing the ambient temperature. In addition, limiting
the overall projection intensity may extend the LEDs’ lifespan.
Page 2 of 18
Ovation FD-105WW User Manual Rev. 2
Page 7
Introduction
2. Introduction
Description
Ovation FD-105WW is a LED Fresnel wash utilizing data and power sensors to run on both dimming power
systems and constant power rigs. A zoom range of 25° to 76° and a soft, warm white wash with high CRI
make it a worthy LED replacement for aging incandescent six-inch Fresnels. Enjoy the benefits of LED
lighting without being held back by previous investments made in major dimming systems.
Features
•Operating modes:
•UNO: 8bit Dim: dimmer control
•DOS: 16bit Dim: dimmer and fine dimmer control
•STD.P: dimmer, dimmer fine, and strobe
•6“ warm white LED Fresnel with class leading output
•Soft and even field of light
•Works perfectly on conventional dimmers or constant power with DMX
•Auto-senses power/data and responds appropriately
•Superior low end dimming whether using dimmers or constant power
•Perfect fixture for the retrofit market, utilizes existing dimming infrastructure flawlessly
•16-bit dimming resolution (DMX mode) for smooth fades
•Flat, even field of light, with manual zoom (25-76 deg)
•Virtually silent operation for use in any situation
Ovation FD-105WW User Manual Rev. 2
Page 3 of 18
Page 8
Product Overview
Control Panel
5-Pin DMX Out
Gel Frame
Holder Clip
Yolk
Voltage Input Switch
Adjustment
Handle
Menu Buttons
5-Pin DMX In
Power Out
3-Pin DMX Out
3-Pin DMX In
Dimmer Control
Knob
Power In
Handle
Safety Cable
Loop
Zoom Control
Knob
Introduction
Page 4 of 18
Ovation FD-105WW User Manual Rev. 2
Page 9
Introduction
6.65 in
169 mm
12.82 in
325.7 mm
6.31 in
160.3 mm
9.37 in
238 mm
8.06 in
204.8 mm
11.08 in
388.5 mm
15.3 in
388.5 mm
Product Dimensions
Ovation FD-105WW User Manual Rev. 2
Page 5 of 18
Page 10
Setup
3. Setup
AC Power
Each Ovation FD-105WW has a switchable power supply that can work with an input voltage of 120 VAC,
60 Hz or 230 VAC, 50 Hz. To determine the power requirements for each Ovation FD-105WW, refer to the
label affixed to the product. You can also refer to the Technical Specifications chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website: www.chauvetprofessional.com
• Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
AC Plug
The Ovation FD-105WW comes with a power input cord terminated with a Neutrik® powerCON®
connector on one end and an Edison plug on the other end (U.S. market). If the power input cord that
came with your product has no plug, or if you need the change the plug, use the table below to wire the
new plug.
ConnectionWire (U.S.)Wire (Europe)Screw Color
AC LiveBlackBrownYellow or Brass
AC NeutralWhiteBlueSilver
AC GroundGreen/YellowGreen/YellowGreen
Power Linking
The product supports power linking. You can power link up to 14 products at 120 V, or up to 24 products at
230 V.
This product comes with a power input cord. Power linking cables are available from Chauvet for purchase
Fuse Replacement
1.Disconnect this product from power.
2.Using a Phillip-head screwdriver, unscrew the fuse holder cap from the housing.
3.Remove blown fuse and replace with a good fuse of the same type and rating (T 3.15 A, 250V).
4.Screw the fuse holder cap back in place and reconnect power.
Make sure to disconnect the product’s power cord before replacing a blown fuse.
Always replace the blown fuse with another of the same type and rating.
.
DMX Linking
You can link the Ovation FD-105WW to a DMX controller using a 3- or 5-pin DMX connection. If using
other DMX-compatible products with this product, you can control each individually with a single DMX
controller.
DMX Personalities
The Ovation FD-105WW uses a 3- or 5-pin DMX data connection for the UNO: 8bit Dim, Dos: 8bit Dim,
16bit Dim, and STD.P: 8bit Dim, 16bit Dim, and strobe DMX personalities.
•Refer to the Introduction
•Refer to the Operation chapter to learn how to configure the Ovation FD-105WW to work in these
personalities.
•The DMX Values section provides detailed information regarding the control personalities.
If you are not familiar with or need more information about DMX standards, Master/
Slave connectivity, or the DMX cables needed to link this product to a DMX controller,
download the DMX Primer from the Chauvet website: www.chauvetprofessional.com
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate
bi-directionally along existing DMX cabling. Check the DMX controller’s User Manual or with the
manufacturer as not all DMX controllers have this capability. The Ovation FD-105WW supports RDM
protocol that allows feedback to make changes to menu map options.
Page 6 of 18
chapter for a brief description of each DMX personality.
.
Ovation FD-105WW User Manual Rev. 2
Page 11
Setup
Master/Slave Connectivity
The Master/Slave mode allows a Ovation FD-105WW (the master) to control one or more Ovation FD105WW products (the slaves) without a DMX controller. One Ovation FD-105WW becomes the master
when running an auto or custom program, or by being in a Static mode.
You must configure each slave’s control panel to operate in Slave mode. During Master/Slave operation,
the slaves will operate in unison with the master.
DO NOT connect a DMX controller to products operating in Master/Slave mode. The
DMX controller signals may interfere with the signals from the master.
•The Operation
configure the master and slaves.
•If you are not familiar with DMX standards or Master/Slave connectivity,
download the DMX Primer from the Chauvet website
www.chauvetprofessional.com
section of this manual provides detailed instructions on how to
for more information.
Dimmer Modes
The Ovation FD-105WW may be plugged into and controlled using a regular dimmer.
•When in SENS mode, advanced onboard electronics automatically detect what type of power and
data the product receives and it responds accordingly. This is the factory default setting.
•When in DMX mode, the product runs only on constant power and is controlled solely on DMX. The
product will not respond to dimmer control in this mode.
•When in DMMR mode, DMX control is turned off. Intensity is controlled using a dimmer. In this
mode, the product reacts exactly like an incandescent product.
For the best performance while running on dimmers, use the settings listed below:
1.Go to the SETTING main level.
2.Select the DIMMER programming level.
3.Select DIM4.
4.Go back to SETTING main level.
5.Select the CURVE programming level.
6.Select CURVE3.
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/
Orientation
Always mount this product in a safe position, making sure there is adequate room for ventilation,
configuration, and maintenance.
Rigging
Chauvet recommends using the following general guidelines when mounting this product.
•Before deciding on a location for the product, make sure there is easy access to the product for
maintenance and programming purposes.
•Make sure that the structure onto which you are mounting the product can support the product’s
weight. See the Technical Specifications
•When mounting the product overhead, always use a safety cable. Mount the product securely to a
rigging point, whether an elevated platform or a truss.
•When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
•When power linking multiple products, mount the products close enough for power linking cables to
reach.
•The bracket adjustment knobs allow for directional adjustment when aiming the product to the
desired angle. Only loosen or tighten the bracket knobs manually. Using tools could damage the
knobs.
for weight information.
.
Ovation FD-105WW User Manual Rev. 2
Page 7 of 18
Page 12
Setup
Bracket
Mounting Clamps
Safety Cables
Bracket
Adjustment Knob
Procedure
The Ovation FD-105WW comes with a bracket to which you can attach a mounting clamp directly. You
must supply the mounting clamps. Make sure the clamps are capable of supporting the weight of this
product. Use at least one mounting point per product. For the CHAUVET Professional line of mounting
clamps, go to http://www.trusst.com/products
Mounting Diagram
.
Page 8 of 18
Ovation FD-105WW User Manual Rev. 2
Page 13
Operation
4. Operation
Control Panel Operation
ButtonFunction
<MENU>Exits from the current menu or function
<ENTER>
<UP>
<DOWN>
<DIM>
Control Options
Set the Ovation FD-105WW starting address in the 001–512 DMX range. This enables control of up to 170
products in the 3-channel STD.P personality.
Programming
Refer to the Menu Map to understand the menu options. The menu map shows the main level and a
variable number of programming levels for each option.
•To go to the desired main level, press <MENU> repeatedly until the option shows on the display.
Press <ENTER> to select. This will take you to the first programming level for that option.
•To select an option or value within the current programming level, press <UP> or <DOWN> until
the option shows on the display. Press <ENTER> to select. In this case, if there is another
programming level, you will see that first option, or you will see the selected value.
•Press <MENU> repeatedly to exit to the previous main level.
Control Panel Lock
This setting allows activation or deactivation of the control panel lock, which keeps non-authorized users
from changing the product’s settings.
1.Go to the SETTINGS main level.
2.Select KEY.
3.Select ON or OFF.
Enables the currently displayed menu or sets the currently selected
value into the selected function
Navigates upwards through the menu list or increases the numeric
value when in a function
Navigates downwards through the menu list or decreases the numeric
value when in a function
Press 2 times rapidly to access the dimmer function. Use knob to
adjust dimmer intensity.
When the control panel lock is activated, after 30 seconds of control panel
inactivity, or after turning on the product, the Ovation FD-105WW will prompt you
to enter the passcode.
Settings Lock
This setting allows activation or deactivation of the menu access lock. Activating the menu access lock
prevent non-authorized personnel from making any changes to the programming levels under the
SETTING main level.
1.Go to the SETTING main level.
2.Select SLOCK.
3.Select ON or OFF.
When the setting lock is activated, in order to access the SETTING level, the
product will prompt for the passcode. Enter the passcode as described below.
Passcode
After being prompted, enter the following passcode: <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>. This
passcode cannot be changed and must be used whenever prompted.
Ovation FD-105WW User Manual Rev. 2
Page 9 of 18
Page 14
Menu Map
Main LevelProgramming LevelsDescription
STATICDIMMER000-100Local control of output
DMX 512Sets the mode to DMX control
SLAVESets the mode to master/slave
RUN MODE
ADDRESS000-512Sets the starting address
KEY
DIMMER
CURVE
PERFORM
SLOCK
SETTING
INFO
PERSONALITY
DMX ERROR
RESET
MODE SETTING
PWM
VERSIONV__Shows total product hours
RDM
DMMR
SENS
ON
OFF
OFFNo dimmer
DIM1
DIM2
DIM3
DIM4
OFFNo dimmer
CURVE1
CURVE2
CURVE3
LIVE
STUDIO
ON
OFF
UNO
STD.P
SAVE
BLACK
PASS CODE:
(Enter Passcode)
SELF
MASTER
600Hz
1200Hz
2000Hz
4000Hz
6000Hz
25KHz
UID_ _ _ _ _Displays product UID for RDM
LABEL_ _ _ _ _Displays product label for RDM
Sets the mode to dimmer control,
which turns off data input
Automatically chooses between
DMMR and DMX
Sets the key lock (Passcode mode)
Slow (DIM4) to fast (DIM1) dimmer
speeds
Large (CURVE3) to small
(CURVE1) dimmer curves
Balances LED cooling using fans
and output power level
Maintains LED cooling by limiting
power level
SETTING menu access lock
Selects DMX personalityDOS
Continues last command upon loss
of DMX signal
Blacks out product upon loss of
DMX signal
Resets product to factory defaults
No DMX output from product in
standalone
Sends DMX output in standalone
mode
Selects the PWM output frequency
Operation
Page 10 of 18
Ovation FD-105WW User Manual Rev. 2
Page 15
Operation
DMX Personalities
This setting allows you to choose a particular DMX personality.
1.Go to the SETTING main level.
2.Select PERSONALITY.
3.Choose the desired personality (UNO, DOS, or STD.P).
•See the DMX Control section for the highest starting address you can select
for each personality.
•Make sure that the starting addresses on the various products do not
overlap due to the new personality setting.
DMX Control
In this mode, each product will respond to a unique starting address from the DMX controller. All products
with the same starting address will respond in unison.
1.Select a DMX personality as shown in DMX Personalities
2.Set the Running Mode:
a.Go to RUN MODE main level.
b.Select DMX 512.
•Note: For information on the SLAVE option, see Master/Slave Mode
3.Set the starting address:
a.Go to ADDRESS main level.
b.Select the starting address (001–512).
The highest recommended starting address for each DMX mode is as follows:
DMX ModeDMX Address
UNO512
DOS511
STD.P 510
.
.
DMX Values
STD.P
ChannelFunctionValuePercent/Setting
1Dimmer000
2Fine Dimmer000
3Strobe
DOS
ChannelFunctionValuePercent/Setting
1Dimmer000
2Dimmer Fine000
UNO
ChannelFunctionValuePercent/Setting
1Dimmer000
2550–100%
2550–100%
009Open
000
010
099Strobe (slow to fast)
100
109Open
110
179Lightning effect (slow to fast)
180
189Open
190
255Random strobe (slow to fast)
2550-100%
2550-100%
2550-100%
Ovation FD-105WW User Manual Rev. 2
Page 11 of 18
Page 16
Operation
Loss of Signal Setting
This setting controls how the product responds when the DMX signal is lost.
1.Go to the SETTING main level.
2.Select DMX ERROR.
3.Choose BLACK to turn off the LEDs when the signal is lost or SAVE to use the last command
programmed when the signal is lost.
Dimmer Control
The Ovation FD-105WW may be plugged into and controlled using a regular dimmer or by being plugged
into constant power and using DMX control. By default the product is set to SENS which automatically
senses the type of power/control being used and sets the product to react accordingly. The product may
also be set to DMMR mode which turns off the DMX control and only allows exclusive control of the
product via the dimmer.
1.Go to the RUN MODE main level.
2.Choose DMMR or SENS.
When SENS and DMMR modes are active, the only control panel button that will
work will be the <ENTER> button which will allow you to change modes.
Dimmer Menu Control
The Static mode allows for permanent dimmer, zoom, and strobe presets without a DMX controller.
1.Go to the STATIC main level.
2.Select DIMMER.
3.Select the desired value 0–100 (0-100% light output).
Dimmer - Manual Control
Manually adjust the light output by using the dimmer adjustment knob, as follows:
1.Press the dimmer adjustment knob above the display twice.
2.Select the desired dimmer setting 000–100 (0–100% light output) by turning the knob clockwise
(value increases) or counter-clockwise (value decreases).
•When using the dimmer adjustment knob, the lowest dimmer value stops at 000
and the highest dimmer value stops at 100.
•During manual dimmer control, you can also use <UP> or <DOWN>, which will
cycle through all the dimmer values.
Dimmer Speeds
This setting determines how fast the output of the Ovation FD-105WW changes when you modify the output
value. This setting provides four different options to simulate the dimming curve of an incandescent lighting
product.
1.Go to the SETTING main level.
2.Go to the DIMMER main level.
3.Select a dimmer curve (Off, DIM 1, DIM 2, DIM 3, or DIM 4).
When selecting DIM1–DIM4, the output will correspond to the dimmer curve option
selected under the dimmer curves programming level (CURV).
Dimmer Curves
Select the dimmer curve of the Ovation FD-105WW by selecting the CURVE programming level.
1.Go to the SETTING main level.
2.Select the CURVE programming level.
3.Select dimmer CURVE 1, CURVE 2, CURVE 3 (small to large), or OFF (linear output).
Page 12 of 18
Ovation FD-105WW User Manual Rev. 2
Page 17
Operation
Master/Slave Mode
The Master/Slave mode allows a single Ovation FD-105WW (the “master”) to control the actions of one or
more Ovation FD-105WW products (the “slaves”) without the need of a DMX controller to control the
slaves. The master will be set to operate in Master mode (MAST), while the slaves will be set to operate in
Slave mode (SLAVE). Once set and connected, the slaves will operate in unison with the master.
To set each of the slaves:
1.Go to the RUN MODE main level.
2.Select SLAVE.
3.Connect the DMX input of the first slave to the DMX output of the master.
4.Connect the DMX input of the subsequent slaves to the DMX output of the previous slave
5.Finish setting and connecting all the slaves
To set the master:
1.Go to the SETTING main level
2.Select MODE SETTING.
3.Select MAST.
•Note: If you select SELF, no DMX signals are sent to the slaves.
4.Make the master the first product in the DMX daisy chain.
5.Control the master using the DMX controller and the slaves will operate in unison.
•The master is the one that runs a program in Static mode.
•Do not connect a DMX controller to the products configured for Master/Slave
operation. The DMX controller may interfere with signals from the master.
•The master should be the first product in the daisy chain.
Factory Reset
This option restores the Ovation FD-105WW to factory default settings.
1.Go to the SETTING main level.
2.Select RESET.
3.Enter the passcode and press ENTER to reset the product to its factory settings.
LED Frequency
This option changes the Pulse Width Modulation (PWM) frequency of the LEDs on the Ovation FD105WW.
1.Go to the SETTING main level.
2.Select PWM.
3.Select PWM Frequency (600Hz, 1200Hz, 2000Hz, 4000Hz, 6000Hz, or 25Khz).
Power Performance Output Options
The Ovation FD-105WW offers two power output options during the cooling of the fixture’s LEDs.
1.Go to the SETTING main level.
2.Select PERFORM.
•Select LIVE to cool the LEDs by balancing the use of the fan and the power output level.
•Select STUDIO to cool the LEDs by maintaining the use of the fan and limiting the power
output level.
System Information
This option displays the total number of hours the product has run, the installed software version, and the
product’s UID.
1.Go to the INFORMATION main level.
2.Select VERSION or RDM, and the product version, UID, or label will be displayed.
Ovation FD-105WW User Manual Rev. 2
Page 13 of 18
Page 18
Technical Information
5. Technical Information
Product Maintenance
To maintain optimum performance and minimize wear, clean this product frequently. Usage and
environment are contributing factors in determining the cleaning frequency.
Clean this product at least twice a month. Dust build-up reduces light output performance and can cause
overheating. This can lead to reduced light source life and increased mechanical wear.
To clean the product:
1.Unplug the product from power.
2.Wait until the product is at room temperature.
3.Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
vents.
4.Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
5.Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
6.Softly drag any dirt or grime to the outside of the transparent surface.
7.Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Do not spin the cooling fan using compressed air because you could damage it.
Page 14 of 18
Ovation FD-105WW User Manual Rev. 2
Page 19
Technical Specifications
6. Technical Specifications
Dimensions and Weight
LengthWidthHeightWeight
12.8 in (326 mm)11 in (279 mm)16.5 in (420 mm)13 lb (5.9 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply TypeRangeVoltage Selection
Switching (internal)100 to 240 VAC, 50/60 HzAuto-ranging
Parameter120 V, 60 Hz230 V, 50 Hz
Consumption115 W125 W
Operating Current0.951 A0.541 A
Power linking current (products)13.6 A (14 products)13.6 A (24 products)
Power I/OU.S./WorldwideUK/Europe
Power input connectorNeutrik® powerCON® ANeutrik® powerCON® A
Power output connectorNeutrik® powerCON® BNeutrik® powerCON® B
Power Cord plugEdison (U.S.)Local Plug
Light Source
TypeColorQuantityPowerCurrentLifespan
LEDWarm White180 W2 A50,000 hours
Photometrics
ParameterValue
Strobe Rate0 to 25Hz
Color Temperature (at full)3197 K
Beam Angle8° to 51°
Field Angle14° to 63°
Zoom Angle14° to 63°
Illuminance @ 5 m (14°)6,609 lux
Illuminance @ 5 m (63°)340 lux
Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will
not issue call tags.
Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product.
Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the
return.
Clearly label the package with an RMA number. Chauvet will refuse any product returned without an RMA
number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number
directly on the box.
Once you have the RMA number, provide the following information on a piece of paper and place it inside
the box:
•Your name
•Your address
•Your phone number
•RMA number
•A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be
your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned
product(s).
Zona Industrial LermaWebsite: www.chauvetprofessional.mx
Voice: +52 (728) 690-2010
Email: FRtech@chauvetlighting.fr
Email: DEtech@chauvetlighting.de
Email: servicio@chauvet.com.mx
Visit the applicable website above to verify our contact information and instructions to request support.
Outside the U.S., United Kingdom, Ireland, Benelux, France, Germany, or Mexico, contact the dealer of
record.
Page 18 of 18
Ovation FD-105WW User Manual Rev. 2
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.