The EPIX Strip IP 50 Quick Reference Guide (QRG) has basic product information such as connection and mounting.
Download the ÉPIX Drive 2000 IP User Manual from
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
•DO NOT open this product. It contains no user-serviceable parts.
•To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
•DO NOT look at the light source when the product is on.
•CAUTION: This product’s housing may be hot when lights are operating.
•CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
•CAUTION: This product’s housing may be hot when lights are operating.
•Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
•DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
•USE a safety cable when mounting this product overhead.
•DO NOT submerge this product (IP65). Temporary outdoor operation is fine.
•When using this product in an outdoor environment, use IP65 (or higher) rated power and data cables. Be sure to
secure unused power and data ports with attached IP65 covers.
•DO NOT operate this product if the housing, ports, or cables appear damaged.
•DO NOT connect this product to a dimmer or rheostat.
•ONLY connect this product to an ÉPIX Drive 2000 IP or ÉPIX Drive 900.
•Only use the hanging/mounting bracket to carry this product.
•In the event of a serious operating problem, stop using immediately.
•The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
Contact
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux contact your distributor to request support or return a
product. Visit www.chauvetprofessional.com for contact information.
What is Included
•EPIX Strip IP 50
•Square Milky Filter (Installed)
•Black Stealth Filter
•Round Milky Filter
•Warranty Card
•Quick Reference Guide
www.chauvetprofessional.com for more details.
1
EPIX Strip IP 50 QRG Rev. 1
Product Overview
Data/Power
QUICK REFERENCE GUIDE
Mounting Bracket
Filter
EN
Data/Power
Interlocking
Hardware
Fastening Knob/
Safety Loop
Product Dimensions
5.04 in
128 mm
3.66 in
93 mm
19.68 in
500 mm
2.32 in
59 mm
3.78 in
96 mm
1.38 in
35 mm
1.89 in
48 mm
1.33 in
34 mm
3.94 in
100 mm
EPIX Strip IP 50 QRG Rev. 1
2
QUICK REFERENCE GUIDE
EN
Power
This product is powered by an ÉPIX Drive 2000 IP or ÉPIX Drive 900. Refer to the ÉPIX Drive 2000 IP/900 User Manuals
for detailed instructions on how to connect this product to power.
Power Linking
You can link up to 20 EPIX Strip IP 50 products to each port of an ÉPIX Drive 2000 IP. Never exceed this number.
•Use ONLY IP65 4-pin XLR cables with the EPIX Strip IP 50. For our CHAUVET Professional line
of IP65 4-pin XLR cables, go to https://www.chauvetprofessional.com/accessories.
!
Filter Installation
The EPIX Strip IP 50 includes a Square Milky Filter already installed. Follow the procedure below to install the included
Black Stealth Filter or Round Milky Filter.
1.Locate the end cap of the product that does not have the interlocking hardware.
2.Push in on the end-cap latch.
3.Slide the installed filter out and replace it with the desired filter.
4.Release the end-cap latch.
•To eliminate wear and improve its lifespan, during periods of non-use completely disconnect
the ÉPIX Drive 2000 IP from power via breaker or by unplugging it.
End-Cap Latch
Interlocking Hardware
3
EPIX Strip IP 50 QRG Rev. 1
QUICK REFERENCE GUIDE
EN
Mounting
Before mounting this product, read the Safety Notes. Use at least one mounting point per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For our CHAUVET Professional line of mounting
clamps, go to http://trusst.com/products.
Mounting Diagram
Safety Cable
Mounting Clamp
Safety Loop
Eye Bolts
EPIX Strip IP 50 QRG Rev. 1
4
QUICK REFERENCE GUIDE
EN
Vertical Mounting Instructions
1.Attach the clamp to the mounting bracket.
2.Attach the clamp to the desired structure or surface.
3.Attach a safety cable to the product’s safety loop.
Attach the Safety Cable
of the first product to
the mounting point
Attach the Safety Cable of the
following products to the
Bracket of the preceding product
!
Never attach more than 6 products together when hanging vertically from a single mounting point.
5
EPIX Strip IP 50 QRG Rev. 1
QUICK REFERENCE GUIDE
EN
Series Attachment Instructions
The EPIX Strip IP 50 can be attached in an end to end formation to create a strip up to 4 meters long from one mounting
point. Do not connect any more than 6 EPIX Strip IP 50 products in a row when hanging vertically.
1.Loosen the 2 fastening eye bolts.
2.Slide the connecting bracket out until it stops and tighten the eye bolt closest to the center of the product.
3.Slide the second EPIX Strip IP 50 into the connecting bracket and tighten the remaining eye bolt.
4.Attach the safety cable as shown in Vertical Mounting Instructions.
1
2
3
Install the safety cable last when attaching EPIX Strip IP 50 products in series.
EPIX Strip IP 50 QRG Rev. 1
6
QUICK REFERENCE GUIDE
EN
Technical Specifications
Dimensions and Weight
FilterLengthWidthHeightWeight
Square Milky Filter19.68 in (500 mm)1.33 in (34 mm)3.93 in (100 mm)3.4 lb (1.5 kg)
Black Stealth Filter19.68 in (500 mm)1.33 in (34 mm)3.46 in (88 mm)3.4 lb (1.5 kg)
Round Milky Filter19.68 in (500 mm)1.77 in (45 mm)5.03 in (128 mm)3.4 lb (1.5 kg)
Note: Dimensions in inches are rounded.
Power
Power SupplyRangePower Linking
ÉPIX Drive 2000 IP100 to 240 VAC, 50/60 Hz20 per ÉPIX Drive 2000 IP port
Data I/OChannel Range (Art-Net™/sACN)Channel Range (Kling-Net)
IP65 4-pin XLR7, 15, 30, 75, or 150
Thermal
Maximum External Temp.Cooling
113 °F (45 °C)Convection
Ordering
Product NameItem NameItem CodeUPC Number
EPIX Strip IP 50EPIXSTRIPIP03091435781462217839
Determined by ArKaos MediaMaster
software
7
EPIX Strip IP 50 QRG Rev. 1
GUÍA DE REFERENCIA RÁPIDA
ES
Acerca de esta guía
La guía de referencia rápida (GRR) del EPIX Strip IP 50 contiene información básica sobre el producto, como conexión y
montaje. Descargue el manual de usuario del ÉPIX Drive 2000 IP www.chauvetprofessional.com para una información
más detallada.
Exención de responsabilidad
La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.
Notas de seguridad
Estas notas de seguridad incluyen información importante sobre el montaje, uso y mantenimiento.
•NO abra este producto. No contiene ninguna pieza reparable por el usuario.
•Para evitar un desgaste innecesario y alargar su vida útil, desconecte completamente el producto de la
alimentación mediante el interruptor o desenchufándolo durante periodos en que no se use.
•NO mire a la fuente de luz cuando el producto esté encendido.
•CUIDADO: la carcasa de este producto puede estar caliente cuando las luces están en funcionamiento.
•CUIDADO: cuando traslade el producto desde ambientes de temperatura extrema (p. ej., desde un camión frío a
una sala de fiestas húmeda y caliente) se puede formar condensación en la electrónica interna del producto. Para
evitar que se produzca un fallo, deje que el producto se aclimate totalmente al entorno antes de conectar la
alimentación.
•CUIDADO: la carcasa de este producto puede estar caliente cuando las luces están en funcionamiento.
•Monte este producto en una ubicación con ventilación adecuada, al menos a 20 in (50 cm) de superficies
adyacentes.
•NO deje ningún material inflamable a menos de 50 cm de este producto mientras esté funcionando o conectado
a la alimentación.
•USE un cable de seguridad cuando monte este producto en lo alto.
•NO sumerja este producto (IP65). Es adecuado para un funcionamiento temporal en exteriores.
•Cuando utilice este producto en exteriores, use cables de datos y alimentación con protección IP65 (o superior).
Asegúrese de proteger los puertos de datos y alimentación que no se usen colocando tapas IP65.
•NO ponga en funcionamiento este producto si la carcasa, puertos o cables parecen dañados.
•NO conecte este producto a un atenuador o reostato.
•Conecte este producto UNICAMENTE a un ÉPIX Drive 2000 IP ÉPIX o Drive 900.
•Use solamente los soportes de colgar/montar para mover este producto.
•En caso de un problema grave de funcionamiento, deje de usarlo inmediatamente.
•La temperatura ambiente máxima es de 113 °F (45 °C). No haga funcionar este producto a temperaturas más
altas.
Contacto
Fuera de EE. UU., Reino Unido, Irlanda, México o Benelux póngase en contacto con su distribuidor para solicitar
asistencia o devolver un producto. Visite www.chauvetprofessional.com para información de contacto.
Qué va incluido
•EPIX Strip IP 50
•Filtro turbio cuadrado (instalado)
•Filtro neutro negro
•Filtro turbio redondo
•Tarjeta de garantía
•Guía de referencia rápida
EPIX Strip IP 50 QRG Rev. 1
8
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.