Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENTS
1. BEFORE YOU BEGIN................................................................................................................................3
HAT IS INCLUDED......................................................................................................................................... 3
POWER ................................................................................................................................................... 3
USE REPLACEMENT...................................................................................................................................... 7
Data Cabling ...........................................................................................................................................
DMX Data Cable............................................................................................................................... 7
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
This fixture has an auto-switching power supply that can accommodate a wide range of input
voltages. The only thing necessary to do before powering on the unit is to make sure the line voltage
you are applying is within the range of accepted voltages. This fixture will accommodate between
100V and 240V AC. All fixtures must be powered directly off a switched circuit and cannot be run off a
rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for
a 0% to 100% switch.
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance of this
product.
•Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
y also receive this instruction booklet.
the
•Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher tha
• This product is intended for indoor use only!
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit w
•The unit must be installed in a location with adequate ventilation, at least 50cm (20in) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
•Always disconnect from power source before servicing or replacing lamp or fuse and
replace with same lamp source.
•Secure fixture to fastening device using a safety chain. Never carr
its carrying handles.
•Maximum ambient temperature (Ta) is 95°F (35°C). Do n
than this.
•In the event of a serious operating problem, stop using the unit immediately
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
• Don’t connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
n that stated on the decal or rear panel of the fixture.
hile operating.
y the fixture solely by its head. Use
ot operate fixture at temperatures higher
. Never try to repair the
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET at: 954-929-1115.
be sure to
Vue™ II User Manual 4 2007-05-10/13:15
Page 5
2.INTRODUCTION
Features
• 6-channel DMX-512 LED moon flower
• Blackout/static/dimmer/strobe
• Individual control of red, green and blue LEDs
• Built-in automated programs via master/slave or DMX
• Built-in sound activated programs via master/slave or DMX
Additional Features
• Creates firework-like projections
• Additional power output for dais
• Linkable with Vue™ I
• Low-power consumption
DMX Channel Summary
CHANNEL FUNCTION
1
2
3
4
5
6
Mode
Red
Green
Blue
Mode 1-9 Speed, Strobe Speed
Dimmer
y chaining units together
Vue™ II User Manual 5 2007-05-10/13:15
Page 6
Product Overview
DMX Input
Connector
Hanging
Bracket
Tilt
Adjustment
Knob
Dipswitches
Signal/Sound
Indicator LED
Power LED
DMX
Output
Connector
Sound
Sensitiv
Knob
Microphone
AC Power Input
& Fuse
Power
Output
Connector
Vue™ II User Manual 6 2007-05-10/13:15
ity
Page 7
3.SETUP
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
Fuse Replacement
With a flat head screwdriver wedge the fuse
holder out of its h
fuse from its holder and replace with exact
same type fuse. Insert the fuse holder back in
its place and reconnect power.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a serial data link determines the number
of fixtures the data link can support.
This fixture uses 6 channels of DMX control.
ousing. Remove the damaged
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
Important:
Maximum recommended serial data link distance:
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485
standard no more than 32 devices should be connected on one data link. Connecting more than 32
fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in
deterioration of the digital DMX signal.
500 meters (1640 ft.)
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
Vue™ II User Manual 7 2007-05-10/13:15
Page 8
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
1
INPUT OUTPUT
3
2
CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
3-PIN TO 5-PIN CONVE
Note! If you use a controller with a 5
PIN TO 5PIN C
3
duc3 Pin Female (output) 5 Pin Male (Input)
Contor
Ground/Shield Pin 1 Pin 1
Data ( - ) signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3
Do not use Do not use
Do not use Do not use
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
DMX
1
3
2
+
-
1
3
Termination reduces signal errors and
2
to avoid signal transmission problems
and interference, it is always
advisable to connect a DMX signal
terminator.
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to
verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each othe
RSION CHART
pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
CHAUVET Model No: DMX5M, or DMX5F.
The chart below details a proper cable co
ONVERSION CHART
nversion:
r.
UX Controller niversal DM
Setting up a DMX Serial Data Link
1. Connect the (male) 3 pin connector sid
the DMX cable to the output (female) 3
connector of the controller.
2.
Connect the end
the controller which will have
of the cable coming from
a (female) 3
pin connector to the input connector of the
ure consisting of a (male) 3 pin
next fixt
connector.
3. t
Then, proceed to connect from the outpu
as stated ab
ove to the input of the following
fixture and so on.
AUVET Certified DMX Data Cables
CH
Order Code D
escription
DMX1.5 DMX Cable 1.5m/4.9ft
DMX4.5
DMX Cable 4
DMX10 DMX Cable 10m/32.8ft
Vue™ II User Manual 8 2007-05-10/13:15
e of
pin
.5m/14.8ft
Continue the link
This drawing provides a
general illustration of the
DMX Input/Output panel of
a lighting fixture.
Page 9
y
nd-Alone/Master/Slave Fixture Linking
Sta
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
ounting
M
RIENTATION
O
RIGGING
2. Connect the end of the cable coming from the first
connector to the input connector of the next fixture
proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave
and Standalone operation requires
at the first fixture in the cha in be
th
itialized for this purpose via either
in
ttings in the control panel or DIP-
e
s
switches. Secondarily, the fixtures
that follow may also require a slave
setting. Please consult the
“Operating Instructions” section in
this manual for complete ins tructions
for this type of setup and
configuration.
This fixture may be mounted in any position provided there is adequate room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the
fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the
fixture by loosening both knobs and tilting the fixture. After finding the
desired position, retighten both knobs.
fixture which will have a (female) 3 pin
consisting of a (male) 3 pin connector. Then,
Hanging Clamp
When selecting installation location, take into consideration lamp
•
replacement access and routine
Safety cables should always be used.
•
• Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
Vue™ II User Manual 9 2007-05-10/13:15
maintenance.
Note!
Clamp is sold separatel
.
Page 10
4.OPERATING INSTRUCTIONS
Operation
Stand-Alone Mode (Sound-Active, Auto Mode, Strobe Mode, All On):
This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto
Mode.
1) Set dipswitches position to Sound-Active or Auto
Mode
Strobe Mode
All On 1-7: Off, 8: On, 9-10: Off
*Effect speed **Strobe speed
1 on = slow
1-2 on = medium 5 on = slow strobing
1-3 on = fast 5-6 on = medium strobing
1-4 on = very fast 5-7 on = fast strobing
2) The unit will react to the low frequencies of music v
3) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in
Dipswitches
Sound-Active 1-8: Off, 9: On, 10: Off
Auto Mode 1-4: Effect speed*, 5-7: Off, 8-9: Off, 10: On
1-4: Off, 5-7: Strobe speed**, 8-10: Off
5-7 off = no strobing
mode, or the unit will auto change in Auto Mode.
Sound-Active mode. Tur
knob clockwise increases the sensitivity.
ning the knob counterclockwise decreases the sensitivity; turning the
Mode.
ia the internal microphone in Sound-Active
Master/Slave Mode (Master Sound, Master Auto):
This mode will allow you to link up to 32 units together without a controller.
1) Use standard DMX cables to daisy chain your units together via th
of the units. For longer cable runs we suggest a terminator at the last fixture. For more
information about terminators, see page 8.
e DMX connector on the rear
2) Determine which fixture will be the master. Connect a DMX cable from the DMX output
connector of the
3) Continue connecting the slaves
4) Set the dipswitches on the master according to the desired mode of operation.
Mode
Master Sound 9 = On, 10 = Off
Master Auto 9 = Off, 10 = On
5) For auto mode, set dipswitches to the desired mode.
Mode Dipswitches
Auto Mode 1-4: Effect speed*, 5-7: Off, 8-9: Off, 10: On
Strobe Mode
All On 1-7: Off, 8: On, 9-10: Off
*Effect speed **Strobe speed
1 on = slow
1-2 on = medium 5 on = slow strobing
1-3 on = fast 5-6 on = medium strobing
1-4 on = very fast 5-7 on = fast strobing
Vue™ II User Manual 10 2007-05-10/13:15
master to the DMX input connector of another Vue I™ or Vue II™.
together with DMX cables
Dipswitches
1-4: Off, 5-7: Strobe speed**, 8-10: Off
5-7 off = no strobing
Page 11
DMX Mode
This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with
DMX, please read the DMX Primer on page 15.
1) Set dipswitches 1-9 to the desired DMX addr
“SETTING THE STARTING ADDRESS” section on the next page.
DMX Channel Values
CHANNEL VALUE FUNCTION
000 Ù
025 Ù 049
050 Ù 074
075 Ù 099
100 Ù
1
125 Ù
150 Ù 174
175 Ù 199
200 Ù 224
225 Ù
250 Ù
2
000 Ù
3
000 Ù
4
000 Ù
5 000 Ù 255
6 000 Ù 255
Control/Operating Mode
Dimmer mode
024
Stand-alone mod
Stand-alone mode 2 (automatic)
Stand-alone mode 3 (automatic)
Stand-alone mode 6 (automatic)
Stand-alone mode 7 (automatic)
Stand-alone mod
249
Stand-alone mode 9 (automatic)
255
Stand-alone (sou
Red (Dimmer Mode)
255
Dimmer: 0 – 100%
Green (Dimmer Mode)
255
Dimmer: 0 – 100%
Blue (Dimmer Mode)
255
Dimmer: 0 – 100%
Stand-alone Speed (Mode 1-9)
(Slow > Fast)
Strobing Speed (Dimmer Mode)
(Slow > Fast)
Dimmer
Open > Closed (100 – 0%)
ess. For help setting the address, see the
e 1 (automatic)
e 8 (automatic)
nd active)
Vue™ II User Manual 11 2007-05-10/13:15
Page 12
SETTING THE STARTING ADDRESS
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address"
from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel
indicated by the start address. For example, a fixture that uses 6 DMX channels and was addressed to start on
DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses
so that the channels used do not overlap, and note the start address selected for future reference.
If this is your first time addressing a fixture using th
Appendix Section and reading the heading “DMX Primer”. It contains very useful information that will help you
understand its use.
Set the start address using the group of DIP switches located usually on bott
has an associated value. Adding the value of each switch in the ON position will provide the start address.
Figuring out which switches to toggle ON given a specific start address can be accomplished by determining
which switch values will add up to the address value, and turning these switches on. Do so by doing the
following:
1) Determine the largest value switch that is less than the start address. Turn this switch on.
2) Subtract the value of the switch you just turned on from the starting address number.
3) Determine the largest value switch that is less than the remainde
switch on.
4) Subtract the value of the switch you just turned on from the remainder of the previous subtraction.
5) Repeat steps three and four until you have a remainder of zero.
EXAMPLE STARTING ADDRESS
256
256
256
256
256
Address 10
Switch # 4 = 8
Switch # 2 = 2
Total = 10
256
e DMX-512 control protocol, we suggest jumping to the
om of the fixture. Each dip switch
r from the previous subtraction. Turn this
128
128
128
128
128
128
64
64
64
64
64
64
32
32
32
32
32
32
16
16
16
16
16
16
8
4
8
4
8
4
8
4
8
4
8
1
2
1
2
1
2
1
2
1
2
13456789
13456789
13456789
13456789
13456789
12222223456789
1
2
4
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
128
256
128
256
128
256
128
256
128
256
128
Address 24
Switch # 5 = 16
Switch # 4 = 8
Total = 24
Resolving address
using simple math.
Address 233
Vue™ II User Manual 12 2007-05-10/13:15
256
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
1 – (1) = 0, Turn ON Dip # 1
Make sure you have the correct audio mode on the
control switches. If audio provided via ¼” jack, make
sure a live audio signal exists
Adjust sound sensitivity knob
Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.
Some discharge lamps require a cooling off period
before the electronics in the fixture can kick start it
again, wait 5 to 10 minutes before powering up
Install terminator
Note: Keep D
or black lights.
MX cables separated from power cables
Lights
9
9
Foggers
& Snow
Controllers
Dimmers
& Chaser
9
9
9
9 9
9 9
9
9
9
9 9
9 9 9 9
9
9
No flash Re-install bulb, may have shifted in shipping
No laser output Bounce mirror motor may have shifted during
shipping, readjust
No light output Check slip ring & brushes for contact
Install bulb
Call service technician
Relay will not work Check reset switch
Check cable connections
Remote does not
work
Stand alone mode All Chauvet lighting fixtures featuring stand-alone
Vue™ II User Manual 14 2007-05-10/13:15
Make sure connector is firmly connected to device
functions do not require additional settings, simply
power the fixture and it will automatically enter into
this mode
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
ort at the location on the next page.
Supp
9
9
9
9 9
9
9
Page 15
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): tech@chauvetlighting.com
Telephone: (954) 929-1115 - (Press 4)
Fax: (954) 929-5560 - (Attention: Service)
Website: http://www.chauvetlighting.com
5.APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air co
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mir
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Chain. A Daisy Chain connection is
mpressor and a soft brush to remove dust
rors must be carried out periodically to
Vue™ II User Manual 15 2007-05-10/13:15
Page 16
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Note: If you are given an RA #, please include the following information on a piece of paper
inside the box
1) Your name
2) Your address
3) Your phone number
4) The RA #
5) A brief description of the symptoms
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.