Chauvet Vue II User Manual

Page 1
Vue™ II
Snapshot
Ok on Dimmer
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
Replaceable Fuse
User Serviceable
Duty Cycle
USER MANUAL
Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENTS
1. BEFORE YOU BEGIN................................................................................................................................3
HAT IS INCLUDED......................................................................................................................................... 3
W
NPACKING INSTRUCTIONS............................................................................................................................. 3
U AC
POWER ................................................................................................................................................... 3
ONTACT US................................................................................................................................................. 3
C S
AFETY INSTRUCTIONS................................................................................................................................... 4
2. INTRODUCTION ...............................................................................................................................
EATURES..................................................................................................................................................... 5
F
CHANNEL SUMMARY.............................................................................................................................. 5
DMX P
RODUCT OVERVIEW ..................................................................................................................................... 6
3. SETUP...............................................................................................................................
USE REPLACEMENT...................................................................................................................................... 7
F
IXTURE LINKING........................................................................................................................................... 7
F
......................... 7
Data Cabling ...........................................................................................................................................
DMX Data Cable............................................................................................................................... 7
Cable Connectors............................................................................................................................. 8
3-Pin to 5-Pin Conversion Chart.......................................................................................................
S
ETTING UP A DMX SERIAL DATA LINK............................................................................................................ 8
TAND-ALONE/MASTER/SLAVE FIXTURE LINKING.............................................................................................. 9
S M
OUNTING.................................................................................................................................................... 9
Orientation........................................................................................................................................
Rigging .............................................................................................................................................
4. OPERATING INSTRUCTIONS..................................................................................................................10
PERATION..................................................................................................................................................10
O
Stand-Alone Mode (Sound-Active, Auto Mode, Strobe Mode, All On): ..................................................10
Master/Slave Mode (Master Sound, Master Auto): ................................................................................10
DMX Mode.............................................................................................................................................11
DMX CHANNEL VALUES................................................................................................................................11
SETTING THE STARTING ADDRESS............................................................................................12
DMX Quick Reference Chart ...........................................................................................................13
ENERAL TROUBLESHOOTING........................................................................................................................14
G T
ECHNICAL SUPPORT....................................................................................................................................15
5. APPENDIX.................................................................................................................................................15
PRIMER...............................................................................................................................................15
DMX G
ENERAL MAINTENANCE ...............................................................................................................................15
ETURNS PROCEDURE..................................................................................................................................16
R C
LAIMS........................................................................................................................................................16
ECHNICAL SPECIFICATIONS ..........................................................................................................................16
T
......... 5
7
8
9 9
Vue™ II User Manual 2 2007-05-10/13:15
Page 3

1. BEFORE YOU BEGIN

What is included

¾ 1 x Vue™ II ¾ Power ¾ W ¾ User

Unpacking Instructions

AC Power

Cord
arranty Card
Manual
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
This fixture has an auto-switching power supply that can accommodate a wide range of input voltages. The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages. This fixture will accommodate between 100V and 240V AC. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.

Contact Us

World Wide
General Information Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
Technical Support Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
World Wide Web www.chauvetlighting.com
th
Court
th
Court
Vue™ II User Manual 3 2007-05-10/13:15
Page 4

Safety Instructions

Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product.
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that y also receive this instruction booklet.
the
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher tha
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit w
The unit must be installed in a location with adequate ventilation, at least 50cm (20in) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing lamp or fuse and
replace with same lamp source.
Secure fixture to fastening device using a safety chain. Never carr
its carrying handles.
Maximum ambient temperature (Ta) is 95°F (35°C). Do n
than this.
In the event of a serious operating problem, stop using the unit immediately
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source while it is on.
n that stated on the decal or rear panel of the fixture.
hile operating.
y the fixture solely by its head. Use
ot operate fixture at temperatures higher
. Never try to repair the
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115.
be sure to
Vue™ II User Manual 4 2007-05-10/13:15
Page 5

2. INTRODUCTION

Features

6-channel DMX-512 LED moon flower
Blackout/static/dimmer/strobe
Individual control of red, green and blue LEDs
Built-in automated programs via master/slave or DMX
Built-in sound activated programs via master/slave or DMX
Additional Features
Creates firework-like projections
Additional power output for dais
Linkable with Vue™ I
Low-power consumption

DMX Channel Summary

CHANNEL FUNCTION
1 2 3 4 5 6
Mode Red Green Blue Mode 1-9 Speed, Strobe Speed Dimmer
y chaining units together
Vue™ II User Manual 5 2007-05-10/13:15
Page 6

Product Overview

DMX Input Connector
Hanging Bracket
Tilt Adjustment Knob
Dipswitches
Signal/Sound Indicator LED
Power LED
DMX Output Connector
Sound Sensitiv Knob
Microphone
AC Power Input & Fuse
Power Output Connector
Vue™ II User Manual 6 2007-05-10/13:15
ity
Page 7
3. SETUP
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.

Fuse Replacement

With a flat head screwdriver wedge the fuse holder out of its h fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power.

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
This fixture uses 6 channels of DMX control.
ousing. Remove the damaged
The fuse is located inside this compartment. Remove using a flat head screwdriver.
Important:
Maximum recommended serial data link distance: Maximum recommended number of fixtures on a serial data link: 32 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
DMX DATA CABLE
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following characteristics:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485
standard no more than 32 devices should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal.
500 meters (1640 ft.)
2-conductor twisted pair plus a shield Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor and shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft. Nominal impedance 100 – 140 ohms
Vue™ II User Manual 7 2007-05-10/13:15
Page 8
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
1
INPUT OUTPUT
3
2
CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
3-PIN TO 5-PIN CONVE
Note! If you use a controller with a 5
PIN TO 5 PIN C
3
duc 3 Pin Female (output) 5 Pin Male (Input)
Con tor Ground/Shield Pin 1 Pin 1 Data ( - ) signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use
Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture.
DMX
1
3
2
+
-
1
3
Termination reduces signal errors and
2
to avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each othe
RSION CHART
pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M, or DMX5F. The chart below details a proper cable co
ONVERSION CHART
nversion:
r.
U X Controller niversal DM

Setting up a DMX Serial Data Link

1. Connect the (male) 3 pin connector sid the DMX cable to the output (female) 3 connector of the controller.
2.
Connect the end the controller which will have
of the cable coming from
a (female) 3
pin connector to the input connector of the
ure consisting of a (male) 3 pin
next fixt connector.
3. t
Then, proceed to connect from the outpu as stated ab
ove to the input of the following
fixture and so on.
AUVET Certified DMX Data Cables
CH
Order Code D
escription DMX1.5 DMX Cable 1.5m/4.9ft DMX4.5
DMX Cable 4
DMX10 DMX Cable 10m/32.8ft
Vue™ II User Manual 8 2007-05-10/13:15
e of pin
.5m/14.8ft
Continue the link
This drawing provides a general illustration of the DMX Input/Output panel of a lighting fixture.
Page 9
y
nd-Alone/Master/Slave Fixture Linking
Sta
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture.
ounting
M
RIENTATION
O
RIGGING
2. Connect the end of the cable coming from the first connector to the input connector of the next fixture proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave and Standalone operation requires
at the first fixture in the cha in be
th
itialized for this purpose via either
in
ttings in the control panel or DIP-
e
s switches. Secondarily, the fixtures that follow may also require a slave setting. Please consult the “Operating Instructions” section in this manual for complete ins tructions for this type of setup and configuration.
This fixture may be mounted in any position provided there is adequate room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs.
fixture which will have a (female) 3 pin
consisting of a (male) 3 pin connector. Then,
Hanging Clamp
When selecting installation location, take into consideration lamp
replacement access and routine
Safety cables should always be used.
Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
Vue™ II User Manual 9 2007-05-10/13:15
maintenance.
Note! Clamp is sold separatel
.
Page 10

4. OPERATING INSTRUCTIONS

Operation Stand-Alone Mode (Sound-Active, Auto Mode, Strobe Mode, All On):
This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode.
1) Set dipswitches position to Sound-Active or Auto Mode
Strobe Mode All On 1-7: Off, 8: On, 9-10: Off
*Effect speed **Strobe speed 1 on = slow
1-2 on = medium 5 on = slow strobing 1-3 on = fast 5-6 on = medium strobing 1-4 on = very fast 5-7 on = fast strobing
2) The unit will react to the low frequencies of music v
3) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in
Dipswitches
Sound-Active 1-8: Off, 9: On, 10: Off Auto Mode 1-4: Effect speed*, 5-7: Off, 8-9: Off, 10: On
1-4: Off, 5-7: Strobe speed**, 8-10: Off
5-7 off = no strobing
mode, or the unit will auto change in Auto Mode.
Sound-Active mode. Tur knob clockwise increases the sensitivity.
ning the knob counterclockwise decreases the sensitivity; turning the
Mode.
ia the internal microphone in Sound-Active
Master/Slave Mode (Master Sound, Master Auto):
This mode will allow you to link up to 32 units together without a controller.
1) Use standard DMX cables to daisy chain your units together via th
of the units. For longer cable runs we suggest a terminator at the last fixture. For more information about terminators, see page 8.
e DMX connector on the rear
2) Determine which fixture will be the master. Connect a DMX cable from the DMX output
connector of the
3) Continue connecting the slaves
4) Set the dipswitches on the master according to the desired mode of operation.
Mode Master Sound 9 = On, 10 = Off Master Auto 9 = Off, 10 = On
5) For auto mode, set dipswitches to the desired mode.
Mode Dipswitches Auto Mode 1-4: Effect speed*, 5-7: Off, 8-9: Off, 10: On
Strobe Mode
All On 1-7: Off, 8: On, 9-10: Off
*Effect speed **Strobe speed 1 on = slow
1-2 on = medium 5 on = slow strobing 1-3 on = fast 5-6 on = medium strobing 1-4 on = very fast 5-7 on = fast strobing
Vue™ II User Manual 10 2007-05-10/13:15
master to the DMX input connector of another Vue I™ or Vue II™.
together with DMX cables
Dipswitches
1-4: Off, 5-7: Strobe speed**, 8-10: Off
5-7 off = no strobing
Page 11
DMX Mode
This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with DMX, please read the DMX Primer on page 15.
1) Set dipswitches 1-9 to the desired DMX addr
“SETTING THE STARTING ADDRESS” section on the next page.

DMX Channel Values

CHANNEL VALUE FUNCTION
000 Ù 025 Ù 049 050 Ù 074 075 Ù 099 100 Ù
1
125 Ù 150 Ù 174 175 Ù 199 200 Ù 224 225 Ù 250 Ù
2
000 Ù
3
000 Ù
4
000 Ù
5 000 Ù 255
6 000 Ù 255
Control/Operating Mode
Dimmer mode
024
Stand-alone mod Stand-alone mode 2 (automatic) Stand-alone mode 3 (automatic)
124
Stand-alone mode 4 (automatic) Stand-alone mode 5 (automatic)
149
Stand-alone mode 6 (automatic) Stand-alone mode 7 (automatic) Stand-alone mod
249
Stand-alone mode 9 (automatic)
255
Stand-alone (sou
Red (Dimmer Mode)
255
Dimmer: 0 – 100%
Green (Dimmer Mode)
255
Dimmer: 0 – 100%
Blue (Dimmer Mode)
255
Dimmer: 0 – 100%
Stand-alone Speed (Mode 1-9)
(Slow > Fast)
Strobing Speed (Dimmer Mode)
(Slow > Fast)
Dimmer
Open > Closed (100 – 0%)
ess. For help setting the address, see the
e 1 (automatic)
e 8 (automatic) nd active)
Vue™ II User Manual 11 2007-05-10/13:15
Page 12
SETTING THE STARTING ADDRESS
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that uses 6 DMX channels and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap, and note the start address selected for future reference.
If this is your first time addressing a fixture using th Appendix Section and reading the heading “DMX Primer”. It contains very useful information that will help you understand its use.
Set the start address using the group of DIP switches located usually on bott has an associated value. Adding the value of each switch in the ON position will provide the start address. Figuring out which switches to toggle ON given a specific start address can be accomplished by determining which switch values will add up to the address value, and turning these switches on. Do so by doing the following:
1) Determine the largest value switch that is less than the start address. Turn this switch on.
2) Subtract the value of the switch you just turned on from the starting address number.
3) Determine the largest value switch that is less than the remainde switch on.
4) Subtract the value of the switch you just turned on from the remainder of the previous subtraction.
5) Repeat steps three and four until you have a remainder of zero.
EXAMPLE STARTING ADDRESS
256
256
256
256
256
Address 10
Switch # 4 = 8 Switch # 2 = 2 Total = 10
256
e DMX-512 control protocol, we suggest jumping to the
om of the fixture. Each dip switch
r from the previous subtraction. Turn this
128
128
128
128
128
128
64
64
64
64
64
64
32
32
32
32
32
32
16
16
16
16
16
16
8
4
8
4
8
4
8
4
8
4
8
1
2
1
2
1
2
1
2
1
2
13456789
13456789
13456789
13456789
13456789
12222223456789
1
2
4
ON
ON
ON
ON
ON
ON OFF
OFF
OFF
OFF
OFF
OFF
128
256
128
256
128
256
128
256
128
256
128
Address 24
Switch # 5 = 16 Switch # 4 = 8 Total = 24
Resolving address using simple math.
Address 233
Vue™ II User Manual 12 2007-05-10/13:15
256
233 – (128) = 105, Turn ON Dip # 8 105 – (64) = 41, Turn ON Dip # 7 41 – (32) = 9, Turn ON Dip # 6 9 – (8) = 1, Turn ON Dip # 4 1 – (1) = 0, Turn ON Dip # 1
64
64
64
64
64
64
32
32
32
32
32
32
16
16
16
16
16
16
8
8
8
8
8
8
4
4
4
4
4
4
1
2
1
2
1
2
1
2
1
2
123456789
123456789
123456789
123456789
123456789
123456789
ON
ON
ON
ON
ON
ON OFF
OFF
OFF
OFF
OFF
OFF
DIPSWITCH (DMX VALUE)
1
1
2
2
3
4
4
8
5
16
6
32
7
64
8
128
9
256
1
2
Page 13
DMX QUICK REFERENCE CHART
DMX Address Quick Reference Chart
Dip Switch Position
DMX DIP
SWITCH SET
0=OFF #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
1=ON #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
X=OFF or ON #6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
#1 #2 #3 #4 #5
0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485 0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501 0 1 1 0 1 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502 1 1 1 0 1 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 0 0 0 1 1 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504 1 0 0 1 1 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 0 1 0 1 1 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 1 1 0 1 1 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 0 0 1 1 1 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 1 0 1 1 1 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 0 1 1 1 1 1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511
Dip Switch Position DMX Address
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
#9
30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510
Vue™ II User Manual 13 2007-05-10/13:15
Page 14

General Troubleshooting

Applies to
Symptom Solution(s)
Auto shut off Check fan thermal switch reset
Beam is very dim or not bright
Breaker/Fuse keeps blowing
Chase is too slow Check users manual for speed adjustment
Device has no power Check for power on Mains.
Fixture is not responding
Fixture is on but there is no movement to the audio
Lamps cuts off sporadically
Light will not come on after power failure
Loss of signal Use only DMX cables
Moves slow Check 220/110v switch for proper setting
Clean optical system or replace lamp Check 220/110v switch for proper setting
Check total load placed on device
Check device’s fuse. (internal and/or external) Check DMX Dip switch settings for correct addressing
Check DMX cables Check polarity switch settings
Make sure you have the correct audio mode on the control switches. If audio provided via ¼” jack, make sure a live audio signal exists Adjust sound sensitivity knob
Possible bad lamp or fixture is overheating. Lamp may be at end of its life.
Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again, wait 5 to 10 minutes before powering up
Install terminator Note: Keep D or black lights.
MX cables separated from power cables
Lights
9 9
Foggers & Snow
Controllers
Dimmers & Chaser
9 9
9
9 9 9 9
9
9
9
9 9
9 9 9 9
9
9
No flash Re-install bulb, may have shifted in shipping
No laser output Bounce mirror motor may have shifted during
shipping, readjust
No light output Check slip ring & brushes for contact
Install bulb Call service technician
Relay will not work Check reset switch
Check cable connections
Remote does not work
Stand alone mode All Chauvet lighting fixtures featuring stand-alone
Vue™ II User Manual 14 2007-05-10/13:15
Make sure connector is firmly connected to device
functions do not require additional settings, simply power the fixture and it will automatically enter into this mode
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
ort at the location on the next page.
Supp
9 9
9
9 9
9
9
Page 15

Technical Support

Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com

5. APPENDIX

DMX Primer

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)

General Maintenance

To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air co collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mir optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Chain. A Daisy Chain connection is
mpressor and a soft brush to remove dust
rors must be carried out periodically to
Vue™ II User Manual 15 2007-05-10/13:15
Page 16

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RA #, please include the following information on a piece of paper
inside the box
1) Your name
2) Your address
3) Your phone number
4) The RA #
5) A brief description of the symptoms

Claims

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.
:

Technical Specifications

WEIGHT & DIMENSIONS
Length..............................................................................................................................
Width ...............................................................................................................................
Height............................................................................................................................. 8.5 in (216 mm)
Weight .................................................................................................................................8 lbs (3.6 kg)
Light Source
Bulb .......................................................................... 162 (60 red, 36 green, 66 blue) LED’s 100,000hrs
Beam angle ........................................................................................................................................ 38°
POWER
Auto-switching power supply.......................................................................... 100V – 240V 50/60Hz AC
Fuse............................................................................................................................................
Power Consumption...............................................................................................................15.3W Max
Inrush Power ...................................................................................................................................
THERMAL
Maximum ambient temperature............................................................................................95° F (35°C
CONTROL & PROGRAMMING
Data input................................................................................................ locking 3-pin XLR male socket
Data output...........................................................................................locking 3-pin XLR female socket
Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols........................................................................................................................
DMX Channels .......................................................................................................................................6
ORDERING INFORMATION
Vue™ II..........................................................................................................................................
WARRANTY INFORMATION
Warranty.............................................................................................................. 2-year limited w
11 in (279 mm) 10 in (254 mm)
2A 250V
4.8W
)
DMX-512 USITT
VUE II
arranty
Vue™ II User Manual 16 2007-05-10/13:15
Loading...