Chauvet TFX-UVLED User Manual

LED Shadow™
TFX-UVLED
USER MANUAL
CHAUVET, 3000 N 29
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
th
Ct, Hollywood, FL 33020 U.S.A
2006-10-11
Table of Contents
1. BEFORE YOU BEGIN....................................................................................................................................................... 3
UNPACKING INSTRUCTIONS..............................................................................................................................................................................................3
CONTACT US................................................................................................................................................................................................................... 3
IMPORTANT SAFETY INFORMATION...................................................................................................................................................................................4
2. INTRODUCTION ............................................................................................................................................................... 5
FEATURES....................................................................................................................................................................................................................... 5
DMX CHANNEL SUMMARY...............................................................................................................................................................................................5
PRODUCT OVERVIEW.......................................................................................................................................................................................................6
3. SETUP............................................................................................................................................................................... 7
AC POWER .....................................................................................................................................................................................................................7
MOUNTING ......................................................................................................................................................................................................................7
FIXTURE LINKING............................................................................................................................................................................................................. 8
Data Cabling ............................................................................................................................................................................................................8
DMX Data Cable.................................................................................................................................................................................................8
Cable Connectors...............................................................................................................................................................................................8
3-Pin to 5-Pin Conversion Chart........................................................................................................................................................................9
SETTING UP A DMX SERIAL DATA LINK............................................................................................................................................................................9
STANDALONE/MASTER-SLAVE FIXTURE LINKING ..............................................................................................................................................................9
4. OPERATING INSTRUCTIONS........................................................................................................................................ 10
STANDALONE MODE......................................................................................................................................................................................................10
Single-Fixture Mode...............................................................................................................................................................................................10
Master-Slave Mode................................................................................................................................................................................................10
Setup................................................................................................................................................................................................................10
Dipswitch Options..................................................................................................................................................................................................10
DMX CONTROL MODE...................................................................................................................................................................................................11
Configuring for DMX control ..................................................................................................................................................................................11
Setting the DMX address.......................................................................................................................................................................................11
DAISY CHAIN (SERIAL DATA LINK)..................................................................................................................................................................................11
5. APPENDIX....................................................................................................................................................................... 12
DMX PRIMER................................................................................................................................................................................................................12
RETURNS PROCEDURE..................................................................................................................................................................................................12
CLAIMS .........................................................................................................................................................................................................................12
MAINTENANCE...............................................................................................................................................................................................................12
BINARY & DMX DIP-SWITCH ADDRESSING.....................................................................................................................................................................13
BINARY ADDRESSING QUICK REFERENCE CHART...........................................................................................................................................................14
DMX CHANNEL VALUES ................................................................................................................................................................................................15
TECHNICAL SPECIFICATIONS..........................................................................................................................................................................................16
TECHNICAL SUPPORT....................................................................................................................................................................................................16
©CHAUVET, 2006, All Rights Reserved Information and specifications in this User Manual are subject to change without
notice. CHAUVET assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.
TFX-UVLED User Manual 2 2006-10-11
/12:19

1. Before You Begin

Unpacking Instructions

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Note: If you should require sending any items back to CHAUVET, call CHAUVET for
a (RMA) Return Merchandise Authorization number. The factory will not allow any shipments without an RMA.
Your shipment includes the following:
1 x LED Shadow™ TFX-UVLED
1 x Power cable
2 x Flush Mount Brackets with screws
Warranty Card
Users Manual

Contact Us

World Wide
General Information Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
Technical Support Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
World Wide Web www.chauvetlighting.com
th
Court
th
Court
TFX-UVLED User Manual 3 2006-10-11
/12:19
Before You Begin

Important Safety Information

This product is designed for professional use. It is not intended for use in a household environment. This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and injury from falls. Read this manual before installing or powering the fixture, follow the safety precautions listed below and observe all warnings in this manual and on the fixture. If you have any questions about how to operate the fixture safely, please contact CHAUVET.
Protection against Electric Shock
Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source.
All Class I fixtures must be connected to circuits with a suitable Earth Ground.
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
Do not operate the fixture if covers are open or if any internal component is missing or damaged: an unshielded discharge lamp emits dangerous UV radiation that can cause burns and eye damage.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the cord.
Protection against Fire & Burns
This product is designed to be used with very specific lamp(s). Use of any other type of lamp not stated in this manual may create a fire hazard due to possible risk of lamp explosion. Using the wrong type of lamp in this product VOIDS the warranty.
Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
Maintain a minimum distance of 1 meter (3.28 feet) from combustible materials.
Allow this product to cool for a minimum of 15 minutes before opening, handling or removing the
lamp in this product.
Maximum ambient temperature is Ta: 40°. Do not operate fixture at temperatures higher than this.
Protection against exposure to (UV) Ultraviolet Radiation
Avoid direct eye exposure to lamp while it is on.
Do not operate the fixture if covers are open or if any internal component is missing or damaged.
Protection against Injury to persons
Secure fixture to fastening device using a safety chain.
A hot lamp is an explosion hazard. Do not open fixture for a minimum of 15 minutes after
switching off. Wear eye and hand protection when re-lamping.
Fixture surface may reach temperatures of up to 160° C (320° F). Handle fixture after it cools.
In the event of serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET.
TFX-UVLED User Manual 4 2006-10-11/12:19

2. Introduction

Features

3-channel DMX-512 LED UV blacklight
Blackout/static/dimmer/strobe
Built-in automatic programs
Adjustable flash rate, dimmer and static via stand-alone
Automatic built-in programs with sound activation
Linkable with LED Techno Strobe™ & LED Techno Strobe RGB™ in stand-alone
Coverage up to 15ft x 30ft
Low power consumption
Additional power output for daisy chaining units together

DMX Channel Summary

Dimmer 000~029
Preset Programs
Sound Mode 225~255 No Function
CONTROL MODES & OPTIONS (Rows)
For a detailed view of DMX values turn to the Appendix section in this manual. Control mode parameters are set by DMX values in Channel # 1.
1 2 3
Intensity
(1 ~ 6)
030~209
0% ~ 100% Speed
Slow ~ Fast
Intensity 100% ~ 0%
DMX Channel
(Columns)
TFX-UVLED User Manual 5 2006-10-11
/12:19
Introduction
p

Product Overview

Hanging Yoke
Power Link Out
IEC Plug for AC Input & Fuse Compartment
DIP-switches DMX Addressing
Audio Sensitivity Rotary knob
Red LED: Power Indicator
Blue LED: Signal Indicator
DMX Out
DMX Input
ut
Flush Mounting Bracket
LED Front Panel
TFX-UVLED User Manual 6 2006-10-11/12:19

3. Setup

AC Power

Warning! Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Power Cable Configuration
CABLE Pin International Screw Color
BROWN Live L Yellow or Brass
BLUE Neutral N Silver
YELLOW/GREEN Earth EG (Ground) Green

Mounting

Orientation
This fixture can be mounted on a truss using a clamp in any position or against a flat surface using the brackets provided.
Rigging
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted and (2) Flush Mount Brackets for flush mounting to flat surfaces. You must supply your own clamp and make sure the clamp is capable of supporting the weight of this fixture. You can order C-clamps from any CHAUVET dealer or distributor.
1. Block access below the work area and use suitable and stable
platform when installing or servicing fixture.
2. Align the clamp screw with the center hole on the yoke and
tighten.
3. Verify the structure can hold 10 times the weight of all to-be
installed fixtures.
4. Adjust the angle on the yoke arm as necessary.
5. Always use a safety cable or chain as a secondary source of
attachment. The safety cable must hold 10 times the weight of the fixture. If safety cable attachment point is provided that is permanently affixed to the surface or body of the fixture, use that instead of looping through a hanging yoke/arm.
Flush Mounting
1. Draw a screw hole template on a large piece of vellum or transparent paper for best alignment.
2. Place paper against the mounting surface and drill holes or mark the surface for drilling.
3. Hang Panel.
Hanging Clamp
Flush Mounting Bracket
TFX-UVLED User Manual 7 2006-10-11
/12:19
Setup

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
The TFX-UVLED fixtures use 3 channels of DMX control.
Important: Fixtures on a serial data link must be daisy chained in one single line. To
comply with the EIA-485 standard no more than 32 devices should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
DMX Data Cable
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20 / 1000 ft.
Nominal impedance 100 - 140
Cable Connectors
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
COMMON
1
INPUT OUTPUT
3 2
DMX +
DMX -
1
3
2
1
3
Termination reduces signal errors and
2
to avoid signal transmission problems
and interference, it is always
advisable to connect a DMX signal
CAUTION Do not allow contact between the common and the fixture’s chassis ground.
Grounding the common can cause a ground loop and your fixture to perform erratically. Test cables with OHM meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture.
TFX-UVLED User Manual 8 2006-10-11/12:19
Setup
3-Pin to 5-Pin Conversion Chart
Note! If you use a controller with a 5 pin DMX output connector, you will need to use
a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M. The chart below details a proper cable conversion:
3 PIN TO 5 PIN CONVERSION CHART
Conductor 3 Pin Female (output) 5 Pin Male (Input) Ground/Shield Pin 1 Pin 1 Data ( - )signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3
Do not use Do not use
Do not use Do not use

Setting up a DMX Serial Data Link

1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
Universal DMX Controller
This drawing provides a general illustration of the DMX Input/Output panel
CHAUVET Certified DMX Data Cables
Order Code Description DMX1.5 DMX Cable 1.5m/4.9ft DMX4.5 DMX Cable 4.5m/14.8ft DMX10 DMX Cable 10m/32.8ft
Continue the link

Standalone/Master-Slave Fixture Linking

1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave
and Standalone operation
requires that the first fixture in the
chain be initialized for this
purpose via either settings in the
control panel or DIP-switches.
Secondarily the fixtures that
follow may also require a slave
setting. Please consult the
“Operating Instructions” section
in this manual for complete
instructions for this type of setup
and configuration.
Fixtures displayed are for illustration purpose only!
TFX-UVLED User Manual 9 2006-10-11/12:19

4. Operating Instructions

The TFX-UVLED is a DMX-512 controllable, flash UV LED panel made up of highly efficient and super bright UV LEDs. The TFX-UVLED can operate in Stand-Alone, Master/Slave and via DMX-512 control utilizing 3 channels.

Standalone Mode

The TFX-UVLED can be operated without a DMX controller in a standalone mode. It can be operated as a single fixture or together with several other TFX-UVLED fixtures in what is called a “Master/Slave” configuration.
2 3 4 5 6 7 8 9 10
1
ON
124
8
163264
128
256
Sound
Auto
Option

Single-Fixture Mode

The TFX-UVLED can be set to operate independently of other fixtures or a DMX controller in either a sound-active or automatic mode. A serial data-link is not necessary for this mode of operation and it is recommended that no connection to other fixtures be made at all.
1. Simply choose from any one of 10 built-in “DIP-switch Options” from the table below.

Master-Slave Mode

A master-slave mode setup consists of more than one fixture connected in a serial data link without the use of a controller. In a master-slave operation the slave fixtures will synchronize and will behave either identically or in a planned chase pattern to the master unit which must be the first in the serial daisy chain. A Master-Slave TFX-UVLED system can consist of an unlimited range of fixtures or at least the number stated to conform to EIA-485 standards.
Setup
1. The TFX-UVLED sets up automatically for Master-Slave, no DIP-switch settings are required other than for selecting DIP-switch Options.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the DMX IN input connector of the Slave fixture consisting of a (male) 3 pin connector. Continue the loop from DMX OUT to DMX IN.

Dipswitch Options

Functions Dipswitches ( ON ) Notes & Description Sound Active None Music: Sound Activated, Rotary knob sets sound sensitivity
Flash
Full On 9 All LEDs full on Preset Program 10 Preset Programs run in Automatic speed
TFX-UVLED User Manual 10 2006-10-11
1 Flash Speed 1 2 Flash Speed 2 3 Flash Speed 3 4 Flash Speed 4 5 Flash Speed 5 6 Flash Speed 6 7 Flash Speed 7 8 Flash Speed 8
/12:19
Operating Instructions

DMX Control Mode

The TFX-UVLED can be operated from a DMX controller. This control mode environment gives the user the greatest flexibility when it comes to customizing or creating a show by enabling the control of each individual trait of the fixture and each fixture independently.

Configuring for DMX control

1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the DMX output as stated above to the DMX input of the following fixture and so on.
4. If you need help setting the DMX address read the section titled “Setting the DMX address” in this Chapter.

Setting the DMX address

Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference. If this is your first time, read the DMX Primer in the Appendix Section.

Daisy Chain (Serial Data Link)

DMX Output
DMX:001
DMX:004
2 3 4 5 6 7 8 9 10
1
2 3 4 5 6 7 8 9 10
1
Visit the section titled; Binary & DMX DIP-switch Addressing on page 13 & Binary Addressing Quick Reference Chart on page 14 to quickly determine the binary DIP-switch settings for addressing.
Use certified DMX XLR cable
2 3 4 5 6 7 8 9 10
1
DMX:007
TFX-UVLED User Manual 11 2006-10-11/12:19

5. Appendix

DMX Primer

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.

Claims

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.

Maintenance

To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.
TFX-UVLED User Manual 12 2006-10-11
/12:19
Appendix
2 3
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

Binary & DMX DIP-switch Addressing

Each DIP-switch has an associated value. Adding the value of each switch in the ON position will provide the final address. Determining which switches to toggle ON given a specific desired address or value can be accomplished in the following manner. By subtracting the largest switch value possible from the selected start address which does not cause a negative number.
Alternatively, using the “Binary Addressing Quick Reference Chart” in the Appendix section of this manual, you can go directly to DIP-switch settings associated with all 512 values available.
EXAMPLE ADDRESS
Address 10
Pin # 4 = 8 Pin # 2 = 2 Total = 10
1
124
4 5 6 7 8 9 10
8
163264
128
ON
256
Address 24
Pin # 5 = 16 Pin # 4 = 8 Total = 24
Resolving address using simple math.
Address 233
2 3 4 5 6 7 8 9 10
1
124
233 – (128) = 105, Turn ON Dip # 8 105 – (64) = 41, Turn ON Dip # 7 41 – (32) = 9, Turn ON Dip # 6 9 – (8) = 1, Turn ON Dip # 4 1 – (1) = 0, Turn ON Dip # 1
You will most likely use the first available
number which maybe number 1. This
number was selected for tutorial
8
163264
purposes.
128
256
ON
D
IP SWITCH (DMX VALUE)
1 2 3 4 5 6 7 8 9
10
1 2 4
8 16 32 64
128 256
TFX-UVLED User Manual 13 2006-10-11/12:19
Appendix

Binary Addressing Quick Reference Chart

DMX & Binary Address Quick Reference Chart
DIP-switch Position
DMX DIP-SWITCH SET #9
0=OFF #8 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
1=ON #7 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
X=OFF or ON #6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
#1 #2 #3 #4 #5
0 0 0 0 0 32 64 96 128 160 192 224 256 288 320 352 384 416 448 480 1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483 0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485 0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488 1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489 0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490 1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491 0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498 1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499 0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500 1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501 0 1 1 0 1 22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502 1 1 1 0 1 23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503 0 0 0 1 1 24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504 1 0 0 1 1 25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505 0 1 0 1 1 26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506 1 1 0 1 1 27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507 0 0 1 1 1 28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508 1 0 1 1 1 29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509 0 1 1 1 1 1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510
DIP-switch Position DMX Address
TFX-UVLED User Manual 14 2006-10-11/12:19
Appendix

DMX Channel Values

NOTE! Please read all instructions carefully on fixture DMX control mode and addressing.
DMX channels 2, and 3 functions are determined by the current settings of channel 1. For example, while Channel 1 is set between 000 and 029 the following conditions will apply;
Channel 2 will control Dimming Intensity from 0% to 100%  Channel 3 will control Dimming Intensity from 100% to 0%
Channel Value Function Ch 2 Ch 3
000 Ù 029 Dimmer Mode Flash Speed
030 Ù 059 Program 1 060 Ù 089 Program 2 090 Ù 119 Program 3
1
120 Ù 149 Program 4 150 Ù 179 Program 5 180 Ù 209 Program 6 210 Ù 255 Sound
No Function
0% Ù 100%
Speed
Slow Ù Fast
Intensity
100%Ù 0%
TFX-UVLED User Manual 15 2006-10-11/12:19
Appendix

Technical Specifications

WEIGHT & DIMENSIONS
Length........................................................................................................................ 355.6 mm (14.0 in)
Width ....................................................................................................................... 247.65 mm (9.75 in)
Height.......................................................................................................................... 165.1 mm (6.5 in)
Weight ......................................................................................................................... 2.22 Kgs (4.9 lbs)
Master Pack................................................................................................. (4 pcs) 12.84 Kgs (28.3 lbs)
POWER
Operating Voltage ................................................................................................. 90V ~ 240V 50/60 Hz
AC input...........................................................................................................................IEC 60320 C14
Current draw................................................................... (peak <12W @ 120V), (inrush <24W @ 120V)
FUSE
Main............................................................................................................... 20mm Glass 2A Fast Blow
LED
Quantity...........................................................................................................................192 Total, (UV)
CONTROL & PROGRAMMING
Data input................................................................................................locking 3-pin XLR male socket
Data output........................................................................................... locking 3-pin XLR female socket
Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols........................................................................................................................DMX-512 USITT
DMX Channels .......................................................................................................................................3
ORDERING INFORMATION
LED Shadow™.....................................................................................................................TFX-UVLED

Technical Support

Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com
TFX-UVLED User Manual 16 2006-10-11/12:19