CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENT
BEFORE YOU BEGIN.................................................................................................................................... 3
WHAT IS INCLUDED......................................................................................................................................... 3
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch. Before applying power to a
fixture, check that the source voltage matches the fixture’s requirement.
Check the fixture or device carefully to make sure that if a voltage selection
switch exists that it is set to the correct line voltage you will use.
Warning! Verify that the power select switch on your unit matches the
line voltage applied. All fixtures must be connected to circuits
with a suitable Earth Ground.
Figure 1 - AC Voltage Switch
Not all fixtures have a voltage
select switch. Please be sure to
connect to the proper voltage.
LRG-55 User Manual 311/14/2007/18:46
Page 4
Introduction
g
Safety Instructions
Please read these instructions carefully, which
includes important information about the installation,
•Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
•Always make sure that you are connecting to the proper voltage and that the line voltage you are
connecting to is not higher than that stated on decal or rear panel of the fixture.
• This product is intended for indoor use only!
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
•The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces. Be sure that no ventilation slots are blocked.
•Always disconnect from power source before servicing or replacing lamp or fuse and be sure to
replace with same lamp source.
•Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use
its carrying handles.
• Maximum ambient temperature is Ta: 35°. Do not operate fixture at temperatures higher than this.
• In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit
by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
• Don’t connect the device to a dimmer pack.
• Make sure power cord is never crimped or damaged.
• Never disconnect power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to lamp while it is on.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
e and maintenance?
usa
LRG-55 User Manual4 11/14/2007/18:46
Page 5
INTRODUCTION
You may notice that both the red and green beams coming out of the projector are larger than the
4.95mW projectors. There is a very distinct reason for this. Unlike 4.95mW projectors the output of
the CHAUVET laser projectors with Fatbeam™ technology inside outputs <20mW for each beam.
Normally outputs greater than 4.95mW require a variance from the FDA. This product has been
designed to meet a special classification of ClassIIIR. Under this classification with the Fatbeam™
technology the acceptable energy levels (AEL) have been met. Therefore the maximum potential
exposure to the unaided eye is less than 4.95mW for a static beam. Additionally the (MPE) or
Maximum Permissible Exposure with this product is below acceptable levels for human ocular or
tissue exposure.
Features
CONTROL FEATURES
• 8-channel DMX controlled green and red laser
• 41 Dynamic, 50 Static patterns, laser off & sound active mode
- Scan and speed adjustment yields 500 laser effects
- 44 patterns in sound active mode
- 48 patterns in auto mode
•X and Y position adjustment of laser effect
- X moves lasers in opposite movements
- Y moves lasers in unison
• Dynamic Scan speed adjust
• Dynamic pattern speed adjust
• Static pattern size adjust
• Laser color selection; red, green or both red & green
FEATURES
•Dual 10mW Fatbeam™ Laser
technology produces 10-14mm
beam which complies with IEC
Safety Standards under ClassIIIR
2 Pattern Selection
3 X Position
4 Y Position
5 Scan speed
6 Dynamic Pattern select
7 Static Pattern size
8 Color
LRG-55 User Manual 511/14/2007/18:46
Page 6
Product Overview
DANGER: Laser Radiation emitted from this aperture.
Before connecting the unit to AC power, make certain that
the front aperture is pointed away from you or others.
Dipswitch settings
for DMX
addressing &
other functions
DMX
connectors
Sound
Sensitivity
Knob
Switch selectable
power
Power Switch
Fan
AC Power Input
LRG-55 User Manual 611/14/2007/18:46
Page 7
AC Power Connection:
The unit is supplied with a power plug appropriate to its voltage and destination. Should any other
connections be required they must be carried out with the following configuration.
Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable
General Instructions
Please read carefully and thoroughly the contents of this manual before operating the Laser system.
These instructions contain important safety information regarding the use and maintenance of this
system. Please keep this manual for future reference.
• Every unit has been thoroughly tested and has been shipped in perfect operating condition.
• Check the shipping carton for damage that may have occurred during shipping.
• If the carton appears to be damaged carefully inspect your unit for any damage.
• Be sure all equipment necessary to operate the system gas arrived intact.
• In the event that damage has been found or parts are missing, please contact CHAUVET customer
support for further instructions.
•Please do not return the unit to your dealer without first contacting CHAUVET customer support.
Notice!
1) Please insure the power supply has good connect with ground before operating the unit in order
to prevent electrical shock.
2) This system is intended to only be operated indoors. Avoid any direct contact with water, and
make certain the unit is firmly mounted.
0
3) Ensure the operating temperature is within the specified normal range of 18~30
4) Prolonged operation shortens the life of the laser device.
5) The system over a long period of time may build up dust and other contaminants on the scanner
optics and or the aperture window.
6) Do not remove any of the laser safety warning labels, manufacturing label, and warranty labels.
If the warranty labels are broken the warranty will be voided.
7) Please contact us if you experience any problems with this unit.
8) NO USER SERVICABLE PARTS INSIDE:
Warranty Void if Warranty Seals are missing or
appear tampered with.
9) Please do not discard the shipping materials. In the event you must return the unit please do so
in the original factory packaging to avoid further damage.
C.
LRG-55 User Manual7 11/14/2007/18:46
Page 8
COMPLIANCE STATEMENT
Your LRG-55 complies with FDA/CDRH 21CFR1040 and Laser Notice 50 as well as IEC 608251:2003. Due to a unique optic design, this product does not exceed output powers that exceed its
classification and output levels government agencies have determined to be appropriate for the
products function.
Laser Safety and Compliance Information
This product is manufactured to comply with the IEC 60825-1 and in accordance with U.S. Food and
Drug Administrations (FDA) Standards listed under FDA Document 21 CFR 1040 and subsequent
laser notices.
Product Classification and Manufacturing Label Identification
Laser Classification Class IIIa
Laser Medium
Cooling Fan Cooled
Output Dual <20mW
Beam Diameter at aperture 10 – 14mm
Beam Divergence Optically adjusted for compliance
Radiant Exposure at
Aperture
DPSS YVO4 532nm / Diode 650nm
<4.95mW (7mm Human Limiting Aperture)
There is only one
laser aperture on
this product.
CAUTION: AVOID EXPOSURE TO BEAM: Avoid
direct eye contact with laser light. Never intentionally
expose your eyes or others to direct laser radiation.
Non-Interlocked Housing Warning Labels. This unit
contains an embedded laser device that exceeds the output
of the intended class internally. Exposure to unsafe levels
of laser radiation when opened.
Additionally there are no user
serviceable parts inside. Tampering
or removing warranty seals will void
your products limited warranty.
CAUTION:
The use of corrective eye wear or
optics for viewing at distances such
as telescopes or binoculars within a
distance of 100mm may pose an eye
hazard.
LRG-55 User Manual8 11/14/2007/18:46
Page 9
Proper Usage
This unit has been designed to be hung. It is recommended that, for safety purposes, your
lighting effect are properly mounted using a suitable hanging clamp and safety cable.
CHAUVET offers a range of items, which are ideal for safe mounting.
It is the responsibility of the manufacturer to provide useful instruction on the proper use of
this product. According to FDA Regulations you should operate the product in the fashion
illustrated below.
CAUTION: Use of controls, adjustments, or performance of
procedures other than what is specified herein may result in
hazardous radiation exposure
CONTROL &FUNCTION
This unit uses dipswitches to assign a units function, DMX address and DMX MODE of function. Each
dipswitch represents a binary value.
Dipswitch Chart
1 2 3 4 5 6 7 8 9 10 11 12
X X X X X X X X X 0 0 0 SOUND ACTIVE
X X X X X X X X X 0 0 1 AUTO MODE
X X X X X X X X X 0 1 0 MASTER_SOUND
X X X X X X X X X 0 1 1 MASTER_AUTO
X X X X X X X X X 1 0 0 SLAVE
X X X X X X X X X 1 1 0 TEST MODE
SET DMX ADDRESS 1 0 1 DMX MODE
Dipswitches #10,#11,and #12 is set system function, from #1 to #9 is set
DIPSWITCH CHART FUNCTION
Function chart
DMX512 address in DMX MODE.
0=OFF 1=ON X=0FF or ON
LRG-55 User Manual9 11/14/2007/18:46
Page 10
DMX Mode
In this mode you will be able to control each individual trait of the fixture independently. The LRG-55
occupies 8 channels of DMX control. For detailed listing of the DMX channel values refer to the
Appendix section.
SETTING THE STARTING ADDRESS
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start
address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data
on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels
of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101,
102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate
the start address selected for future reference.
If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping
to the Appendix Section and read the heading “DMX Primer”. It contains very useful information that
will help you understand its use.
Set the start address using the group of DIP switches located usually on bottom of the fixture. Each
dip switch has an associated value. Adding the value of each switch in the ON position will provide
the start address. Determining which switches to toggle ON given a specific start address can be
accomplished in the following manner. By subtracting the largest switch value possible from the
selected start address which does not cause a negative number.
EXAMPLE STARTING ADDRESS
Address 10
Pin # 4 = 8
Pin # 2 = 2
Total = 10
Address 24
Pin # 5 = 16
Pin # 4 = 8
Total = 24
Resolving address
using simple math.
Address 233
1
4
2
16
8
32
64
ON
OFF
1
4
2
16
8
64
32
ON
OFF
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
1 – (1) = 0, Turn ON Dip # 1
You will most likely use the first
available number which maybe number
1. This number was selected for
example purposes.
256
128
DIP
1211
128
10987654321
256
DIP
10987654321
IP SWITCH (DMXVALUE)
D
1
2
3
4
5
6
7
8
9
1211
1
2
4
8
16
32
64
128
256
LRG-55 User Manual10 11/14/2007/18:46
Page 11
Operation
Stand-Alone Operation (Sound_Active, Auto Mode):
This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto
Mode.
1) Set dipswitches position to Sound Active or Auto Mode.
Mode Dipswitches
Sound Active 10 = Off, 11 = Off, 12 = Off
Auto Mode 10 = Off, 11 = Off, 12 = On
2) The unit will react to the low frequencies of music via the internal microphone in Sound Active
mode, or the unit will auto change in Auto Mode.
3) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in
This mode will allow you to link up to 32 units together without controller.
1) Use standard XLR DMX cable to daisy chain your units together via the XLR connector on the
rear of the units. For longer cable runs we suggest a terminator on the last fixture.
2) Choose a unit to function as Master mode. Turn dipswitches to the Master position on the unit.
The unit must be first unit in line. Then simply chain the units together using XLR cable.
Mode Dipswitches
Master Sound 10 = Off, 11 = On, 12 = Off
Master Auto 10 = Off, 11 = On, 12 = On
3) Turn switch to the Slave position on the slave units, and they will react the same as the Master.
Mode Dipswitches
Slave 10 = On, 11 = Off, 12 = Off
1: MASTER 2: SLAVE N: SLAVE
LRG-55 User Manual11 11/14/2007/18:46
POWER
IN
Page 12
Universal DMX Control (DMX Mode):
This mode allows you to use a universal DMX-512 controller to control lasers operation and effects.
1) To control your fixture in DMX Mode use standard XLR DMX cable to daisy chain your units
together via the XLR connector on the rear of the units. For long cable runs we suggest a
terminator at the last fixture.
Mode Dipswitches
DMX mode 10 = On, 11 = Off, 12 = On
2) Assign a DMX address to the unit by following the dipswitch chart.
3) Use DMX controller to control your units.
DMX-512
Note! System doesn’t use DMX controller in Master-Slave Mode.
System may not set to two Master units in Master-Slave Mode.
Trouble Shooting
1) If the power supply indicator does not light up and the laser does not work, please check if the
power supply and the corresponding parts have the right input electric current.
2) If it is in stand-alone mode operation, the power supply indicator is lit and the laser is not
working, please check if the operation system is set up in Master/Slave mode.
3) If it is in Master/Slave mode, Slave mode is exceptional, please check as below:
A. Make sure to set up Master mode for just one unit and the others are set in slave mode.
B. Make sure to control the unit with DMX controller.
C. Make sure to take a good quality power cord and connection.
4) If the unit is in DMX mode, the laser cannot be controlled by the DMX controller, and the DMX
signal indicator is not illuminated please check as below:
A. Make sure to set up the DMX mode.
B. Make sure to have a good connection.
5) If it is in DMX mode, the laser is cannot be controlled by the DMX controller but the DMX signal
indicator flashes, please make sure the DMX controller and the laser have the same DMX
Address.
6) If the no laser outputs from the projector please restart the AC power by turning off the AC
switch and leaving off for 15 seconds and then turning the switch back to the on position.
7) If the test pattern is not in the proper position restart the AC power by turning off the AC switch
and leaving off for 15 seconds and then turning the switch back to the on position.
After trying the above solution you still have a problem, please contact CHAUVET.
IN
1: DMX 2: DMX N: DMX
POWER
LRG-55 User Manual12 11/14/2007/18:46
Page 13
APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
FIXTURE LINKING
Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5
pin to 3 pin adapter. CHAUVET Model No: DMX5M.
The chart below details a proper cable conversion:
3PIN TO 5PIN CONVERSION CHART
C
GROUND/SHIELDPin 1 Pin 1
DATA (-)SIGNALPin 2 Pin 2
DATA (+) SIGNALPin 3 Pin 3
Figure 2 - DMX connector configuration
1
3
2
INPUT OUTPUT
3
2
ONDUCTOR3 Pin Female (output) 5 Pin Male (Input)
1
+
-
1
3
2
Termination reduces signal errors and to
avoid signal transmission problems and
interference, it is always advisable to connect
a DMX signal terminator.
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
Dynamic Pattern Speed Control
Fast > Slow / See page 16
Static Pattern Size Control
Small > Big / See page 17
Color
Green & Red ON
Green
Red
1) If the power supply indicator does not light up and the laser does not work, please check if the
power supply and the corresponding parts have the right input electric current.
2) If it is in stand-alone mode operation, the power supply indicator is lit and the laser is not
working, please check if the operation system is set up in Master/Slave mode.
3) If it is in Master/Slave mode, Slave mode is exceptional, please check as below:
A. Make sure to set up Master mode for just one unit and the others are set in slave mode.
B. Make sure to control the unit with DMX controller.
C. Make sure to take a good quality power cord and connection.
4) If the unit is in DMX mode, the laser cannot be controlled by the DMX controller, and the DMX
signal indicator is not illuminated please check as below:
A. Make sure to set up the DMX mode.
B. Make sure to have a good connection.
5) If it is in DMX mode, the laser is cannot be controlled by the DMX controller but the DMX signal
indicator flashes, please make sure the DMX controller and the laser have the same DMX
Address.
6) If the no laser outputs from the projector please restart the AC power by turning off the AC
switch and leaving off for 15 seconds and then turning the switch back to the on position.
7) If the test pattern is not in the proper position restart the AC power by turning off the AC switch
and leaving off for 15 seconds and then turning the switch back to the on position.
After trying the above solution you still have a problem, please contact CHAUVET.
LRG-55 User Manual 1511/14/2007/18:46
Page 16
Dynamic Patterns & DMX Values
LRG-55 User Manual 1611/14/2007/18:46
Page 17
Static Patterns & DMX Values
LRG-55 User Manual17 11/14/2007/18:46
LRG-55 User Manual17 11/14/2007/18:46
Page 18
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off
fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Claims
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
LRG-55 User Manual18 11/14/2007/18:46
Page 19
Technical Specifications
WEIGHT & DIMENSIONS
Length......................................................................................................................... 256 mm (10.08 in)
Width .......................................................................................................................... 270 mm (10.63 in)
Height........................................................................................................................... 130 mm (5.12 in)
Weight ......................................................................................................................... 4.25 Kg (9.37 lbs)
POWER
Switch-selectable power settings..............................................................120V 60Hz AC or 230V 50Hz