Chauvet M-Mover, M-Mover Multi Mover User Manual

Page 1
M-MOVER
Multi Mover™
Snapshot
Ok on Dimmer
Outdoor OK
Sound Activated
DMX512
Master/Slave
115V/230V Switch
User Serviceable
Duty Cycle
USER MANUAL
Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENTS
1. BEFORE YOU BEGIN................................................................................................................................3
WHAT IS INCLUDED......................................................................................................................................... 3
UNPACKING INSTRUCTIONS............................................................................................................................. 3
AC POWER ................................................................................................................................................... 3
CONTACT US................................................................................................................................................. 3
SAFETY INSTRUCTIONS................................................................................................................................... 4
2. INTRODUCTION ........................................................................................................................................ 5
FEATURES..................................................................................................................................................... 5
DMX CHANNEL SUMMARY.............................................................................................................................. 5
PRODUCT OVERVIEW ..................................................................................................................................... 6
3. SETUP........................................................................................................................................................ 7
PLATFORM PLATE MOUNTING.......................................................................................................................... 7
FUSE REPLACEMENT...................................................................................................................................... 7
FIXTURE LINKING........................................................................................................................................... 7
Data Cabling ........................................................................................................................................... 7
DMX Data Cable............................................................................................................................... 8
Cable Connectors............................................................................................................................. 8
3-Pin to 5-Pin Conversion Chart....................................................................................................... 8
SETTING UP A DMX SERIAL DATA LINK............................................................................................................ 9
STAND-ALONE/MASTER/SLAVE FIXTURE LINKING.............................................................................................. 9
MOUNTING...................................................................................................................................................10
Orientation.......................................................................................................................................10
Rigging ............................................................................................................................................10
4. OPERATING INSTRUCTIONS..................................................................................................................10
NAVIGATING THE CONTROL PANEL .................................................................................................................10
MENU MAP...................................................................................................................................................11
Menu Functions .....................................................................................................................................12
User Configurations ...............................................................................................................................12
To set the pan to inverting or non-inverting: ....................................................................................12
To reverse the display: ....................................................................................................................12
Service Functions ..................................................................................................................................12
To turn the Platform Power on or off:...............................................................................................12
To reset the fixture: ..........................................................................................................................12
To restore all settings to their factory defaults: ................................................................................12
OPERATION..................................................................................................................................................13
Stand-Alone Mode (Auto Mode):............................................................................................................13
Master/Slave Mode (Master Auto): ........................................................................................................13
DMX Mode.............................................................................................................................................14
DMX CHANNEL VALUES................................................................................................................................14
General Troubleshooting........................................................................................................................15
TECHNICAL SUPPORT....................................................................................................................................16
5. APPENDIX.................................................................................................................................................16
DMX PRIMER...............................................................................................................................................16
GENERAL MAINTENANCE ...............................................................................................................................17
RETURNS PROCEDURE..................................................................................................................................17
CLAIMS........................................................................................................................................................17
TECHNICAL SPECIFICATIONS ..........................................................................................................................18
Multi Mover User Manual 2 2007-01-03/16:45
Page 3
1. BEFORE YOU BEGIN
What is included
¾ 1 x Multi Mover™ ¾ Power Cord ¾ Warranty Card ¾ User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture’s requirement. Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the
line voltage applied. Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch. All fixtures must be connected to circuits with a suitable Earth Ground.
Figure 1 - AC Voltage Switch
Not all fixtures have a voltage select switch. Please be sure to connect to the proper voltage.
Contact Us
World Wide
General Information Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
Technical Support Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
World Wide Web www.chauvetlighting.com
Multi Mover User Manual 3 2007-01-03/16:45
th
Court
th
Court
Page 4
Safety Instructions
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source.
Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles.
Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher than this.
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115.
Multi Mover User Manual 4 2007-01-03/16:45
Page 5
2. INTRODUCTION
Features
4-channel DMX-512 media mover
Pan: 540° (ultra smooth)
Vector speed, power on/off and reset channel
Additional Features
3-pin and 5-pin DMX connections on base and platform
5 RCA in/out connections capable of up to a 720p signal (individually grounded)
1 XLR in/out connection
DMX pass-through to platform when power is on/off
IEC and Edison power connectors on platform
Convenient ¼”-turn fasteners
Multiple mounting options:
Platform plate with mounting slots Dual mounting brackets
Built-in automatic programs via master/slave
Automatic pan correction
Micro-stepping motors
LED display
16bit pan resolution
Isolated fuses for base and platform
Fan cooled
DMX Channel Summary
CHANNEL FUNCTION
1 2 3 4
Pan Fine Pan Vector Speed Platform Power
Multi Mover User Manual 5 2007-01-03/16:45
Page 6
Product Overview
r
k
Platform
XLR In/Out Connector
IEC Power Out Connector
Edison Power Out Connector
Base
Control Panel
¼ Turn Fasteners
RCA In/Out Connectors
Platform Front
5-pin DMX Output Connecto
DMX Output Connector
Platform Bac
Voltage Selector Switch
Base Back
AC Power Switch
Multi Mover User Manual 6 2007-01-03/16:45
Base Fuse
Platform Fuse
IEC Power Connector
5-pin DMX Output Connector
5-pin DMX Input Connector
DMX Input Connector
DMX Output Connector
XLR In/Out
RCA In/Out connectors
Base Front
Page 7
3. SETUP
Platform Plate Mounting
You may mount many different items to the Multi Mover ™ using the included platform and brackets.
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
Fuse Replacement
With a flat-head screwdriver, unscrew the fuse holder from its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Screw the fuse holder back in its place and reconnect power.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485
Maximum recommended serial data link distance: 500 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
The fuse is located inside this compartment. Remove using a flat head screwdriver.
standard no more than 32 devices should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal.
FUSE
Multi Mover User Manual 7 2007-01-03/16:45
Page 8
DMX DATA CABLE
COMMO
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following characteristics:
2-conductor twisted pair plus a shield Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor and shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft. Nominal impedance 100 – 140 ohms
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
1
INPUT OUTPUT
3 2
CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
3-PIN TO 5-PIN CONVE
Note! If you use a controller with a 5
PIN TO 5 PIN C
3 Conductor 3 Pin Female (output) 5 Pin Male (Input)
Grou hield nd/S Pin 1 Pin 1 Data ( - ) signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use
Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture.
DMX
1
3
N
+
1
-
2
3
Termination reduces signal errors and
2
to avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each othe
RSION CHART
pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M, or DMX5F. The chart below details a proper cable conversion:
ONVERSION CHART
r.
Multi Mover User Manual 8 2007-01-03/16:45
Page 9
Setting up a DMX Serial Data Link
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
CHAUVET Certified DMX Data Cables
Order Code Description DMX1.5 DMX Cable 1.5m/4.9ft DMX4.5 DMX Cable 4.5m/14.8ft DMX10 DMX Cable 10m/32.8ft
Universal DMX Controller
This drawing provides a general illustration of the DMX Input/Output panel of a lighting fixture.
Stand-Alone/Master/Slave Fixture Linking
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave and Standalone operation requires that the first fixture in the cha in be initialized for this purpose via either settings in the control panel or DIP­switches. Secondarily, the fixtures that follow may also require a slave setting. Please consult the “Operating Instructions” section in this manual for complete ins tructions for this type of setup and configuration.
Continue the link
Multi Mover User Manual 9 2007-01-03/16:45
Page 10
Mounting
y
ORIENTATION
This fixture must be mounted horizontally. The base may be set on a flat surface or suspended. However, the base must always be parallel to the floor.
Floor
RIGGING
It is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs.
When selecting installation location, take into consideration lamp replacement access and routine maintenance.
Safety cables should always be used.
Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
Always use heavy duty hanging clamps with this fixture.
4. OPERATING INSTRUCTIONS
Navigating the Control Panel
Access control panel functions using the four panel buttons located directly underneath the LCD Display. NOTE: The display will turn off after 30 seconds if no buttons are pushed.
Hanging Clamp
Note! Clamp is sold separatel
.
Button Function
<MODE/ESC>
<UP>
<DOWN>
<ENTER>
Multi Mover User Manual 10 2007-01-03/16:45
Used to access the menu or to scroll through top-level menu items.
Scrolls through menu options in ascending order
Scrolls through menu options in descending order
Used to select and store the current menu or option within a menu
CONTROL PANEL
MODE /ESC
DMX Signal Indicator
UP
ENTER
DOWN
Page 11
Menu Map
The Control Panel LED Display shows the menu items you select from the menu map on page 13. When a menu function is selected, the display will show immediately the first available option for the selected menu function. To select a menu item, press <ENTER>.
Press the <MODE/ESC> button once to activate the control panel. Pressing the <MODE/ESC> button again will scroll through the different top-level menu options available. Use the <UP> and <DOWN> buttons to navigate the menu options. Press the <ENTER> button to access the menu function currently displayed or to enable a menu option. To return to the previous option or menu without changing the value, press the <MODE/ESC> button.
Multi Mover User Manual 11 2007-01-03/16:45
Page 12
Menu Functions
MENU OPTION DESCRIPTION
Stand Alone – Automatic: The built in programs will trigger automatically to a pre-
programmed speed time. Slave Unit: Sets the fixture to run in sync with the Master. You must set the first
fixture in the data link to “Master” otherwise nothing will happen. DMX: The fixture will be controlled by a DMX signal coming from a DMX controller.
The starting address must be selected, and can be set using the up and down buttons.
User Configurations
TO SET THE PAN TO INVERTING OR NON-INVERTING:
1) Press <MODE/ESC> until is displayed. Use the <UP> and <DOWN> buttons to
scroll through the two options.
is non-inverting; is inverting.
TO REVERSE THE DISPLAY:
1) Press <MODE/ESC> until or is displayed.
2) Use the <UP> and <DOWN> buttons to scroll through the two options. is normal;
is reversed.
Service Functions
TO TURN THE PLATFORM POWER ON OR OFF:
1) Press the <MODE/ESC> button until or is displayed.
2) Use the <UP> and <DOWN> buttons to select the desired option and then press the <ENTER>
button.
TO RESET THE FIXTURE:
turns the platform power on; turns the platform power off.
1) Press the <MODE/ESC> button until is displayed, and then press the <ENTER>
button. The fixture will now reset itself.
TO RESTORE ALL SETTINGS TO THEIR FACTORY DEFAULTS:
1) Press the <MODE/ESC> button until is displayed, and then press the <ENTER>
button. The fixture will now load all factory default settings.
Multi Mover User Manual 12 2007-01-03/16:45
Page 13
Operation Stand-Alone Mode (Auto Mode):
This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode.
1) Press <MODE/ESC> until
2) Use the <UP> and <DOWN> buttons to scroll through until the is displayed and
press the <ENTER> button.
3) The unit will auto rotate in Auto Mode.
Master/Slave Mode (Master Auto):
This mode will allow you to link up to 32 units together without a controller.
1) Use standard DMX cables to daisy chain your units together via the DMX connector on the rear
of the units. For longer cable runs we suggest a terminator at the last fixture. For more information about terminators, see page 8.
2) Choose a unit to function as the master. Press <MODE/ESC> until
is displayed on the master unit.
3) Use the <UP> and <DOWN> buttons to scroll through until
press the <ENTER> button.
, or is displayed.
will be displayed.
or
is displayed and
will be displayed.
4) Press <MODE/ESC> until
the <UP> and <DOWN> buttons to scroll through until
<ENTER> button.
or is displayed on the slave units. Use
will be displayed
is displayed and press the
Multi Mover User Manual 13 2007-01-03/16:45
Page 14
DMX Mode
This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with DMX, please read the DMX Primer on page #.
1) Press <MODE/ESC> until
2) Use the <UP> and <DOWN> buttons to select the desired address and press the <ENTER>
button.
DMX Channel Values
CHANNEL VALUE FUNCTION
1 000 Ù 255
2 000 Ù 255 Fine Pan
3
000 Ù 255
000 Ù 129 130 Ù 139 140 Ù 209
4
210 Ù 219 220 Ù 229 230 Ù 239 240 Ù 255
is displayed.
Pan
0 – 540° 128 = halfway point
Vector Speed
Normal > Slow Control/Service
No function Pan movement reset No function Platform power on No function Platform power off No function
Multi Mover User Manual 14 2007-01-03/16:45
Page 15
General Troubleshooting
Applies to
Symptom Solution(s)
Auto shut off Check fan thermal switch reset
Beam is very dim or not bright
Breaker/Fuse keeps blowing
Chase is too slow Check users manual for speed adjustment
Device has no power Check for power on Mains.
Fixture is not responding
Fixture is on but there is no movement to the audio
Lamps cuts off sporadically
Light will not come on after power failure
Loss of signal Use only DMX cables
Moves slow Check 220/110v switch for proper setting
Clean optical system or replace lamp Check 220/110v switch for proper setting
Check total load placed on device
Check device’s fuse. (internal and/or external) Check DMX Dip switch settings for correct addressing
Check DMX cables Check polarity switch settings
Make sure you have the correct audio mode on the control switches. If audio provided via ¼” jack, make sure a live audio signal exists Adjust sound sensitivity knob
Possible bad lamp or fixture is overheating. Lamp may be at end of its life.
Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again, wait 5 to 10 minutes before powering up
Install terminator Note: Keep DMX cables separated from power cables or black lights.
Lights
9 9
Foggers
& Snow
Controllers
Dimmers
& Chaser
9 9
9
9 9 9 9
9
9 9
9 9
9 9 9 9
9
9
No flash Re-install bulb, may have shifted in shipping
No laser output Bounce mirror motor may have shifted during shipping,
readjust
No light output Check slip ring & brushes for contact
Install bulb Call service technician
Relay will not work Check reset switch
Check cable connections
Remote does not work
Stand alone mode All Chauvet lighting fixtures featuring stand-alone
Multi Mover User Manual 15 2007-01-03/16:45
Make sure connector is firmly connected to device
functions do not require additional settings, simply power the fixture and it will automatically enter into this mode
If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support at the location on the next page.
9 9
9
9 9
9
9
Page 16
Technical Support
Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com
5. APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
Multi Mover User Manual 16 2007-01-03/16:45
Page 17
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Claims
Note: If you are given an RA #, please include the following information on a piece of paper
inside the box:
1) Your name
2) Your address
3) Your phone number
4) The RA #
5) A brief description of the symptoms
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.
Multi Mover User Manual 17 2007-01-03/16:45
Page 18
Technical Specifications
WEIGHT & DIMENSIONS
Length........................................................................................................................... 17.5 in (445 mm)
Width ............................................................................................................................ 14.5 in (368 mm)
Height........................................................................................................................... 10.3 in (262 mm)
Weight ..........................................................................................................................37.2 lbs (16.9 kg)
POWER
Switch-selectable power settings..............................................................120V 60Hz AC or 230V 50Hz
Power Consumption..................................................................................................................24W Max
Inrush Power .................................................................................................................................... 36W
Power Output (AC Plug).............................................................. 1650W at 110V, 3450W at 230V Max
LOAD CAPACITY
Platform ................................................................................................................... 110 lbs (50 kg) Max
ROTATION
Pan................................................................................................................................................... 540°
THERMAL
Maximum ambient temperature...........................................................................................104°F (40°C)
FUSE
Main....................................................................................................20mm Glass 10A 250V Fast Blow
Platform..............................................................................................20mm Glass 15A 250V Fast Blow
CONTROL & PROGRAMMING
Data input..............................................locking 3-pin XLR male socket, locking 5-pin XLR male socket
Data output......................................locking 3-pin XLR female socket, locking 5-pin XLR female socket
Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)
Protocols........................................................................................................................DMX-512 USITT
DMX Channels .......................................................................................................................................4
Bandwidth (-3dB)
RCA In/Out....................................................................................................... 85 MHz at Z
XLR In/Out........................................................................................................ 85 MHz at Z
ORDERING INFORMATION
Multi Mover.............................................................................................................................M-MOVER
WARRANTY INFORMATION
Warranty.............................................................................................................. 2-year limited warranty
= 75 ohms
in
= 75 ohms
in
Multi Mover User Manual 18 2007-01-03/16:45
Loading...