Chauvet MIST-PAR80, MIST-PANEL, MIST-PS8, MIST-CON User Manual

COLORmist System
USER MANUAL
MIST-PAR80
COLORmist (Par)
MIST-PANEL
COLORmist Panel
MIST-CON
COLORmist Controller
MIST-PS8
COLORmist Power Unit
CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
2005-10-10/18:36
Table of Content
BEFORE YOU BEGIN....................................................................................................................................................... 3
COLORMIST SYSTEM.................................................................................................................................................................................................. 3
UNPACKING INSTRUCTIONS..............................................................................................................................................................................................3
AC POWER ..................................................................................................................................................................................................................... 3
SAFETY INSTRUCTIONS....................................................................................................................................................................................................3
INTRODUCTION............................................................................................................................................................... 4
FEATURES.......................................................................................................................................................................................................................4
MIST-CON DMX CHANNEL SUMMARY ............................................................................................................................................................................ 4
PRODUCT OVERVIEW.......................................................................................................................................................................................................5
SETUP .............................................................................................................................................................................. 6
POWER ...........................................................................................................................................................................................................................6
MOUNTING (MIST-PAR80)..............................................................................................................................................................................................6
MOUNTING (MIST-PAN)..................................................................................................................................................................................................6
OPERATING INSTRUCTIONS.......................................................................................................................................... 7
CONTROL PANEL .............................................................................................................................................................................................................7
MENU DIAGRAM............................................................................................................................................................................................................... 7
SYSTEM SETUP ...............................................................................................................................................................................................................7
Initial Setup.........................................................................................................................................................................................................7
Re-initialization...................................................................................................................................................................................................7
SINGLE ACTION PROGRAMS............................................................................................................................................................................................. 8
Choosing Single Action Programs ..................................................................................................................................................................... 8
DMX CONTROL MODE..................................................................................................................................................................................................... 9
Setting the DMX address ...................................................................................................................................................................................9
Running in DMX Mode....................................................................................................................................................................................... 9
Daisy Chain Connection..................................................................................................................................................................................... 9
SYSTEM CONFIGURATION & CONNECTION........................................................................................................................................................................9
APPENDIX...................................................................................................................................................................... 10
DMX PRIMER ................................................................................................................................................................................................................10
Fixture Linking ..................................................................................................................................................................................................10
DMX CHANNEL VALUES ................................................................................................................................................................................................11
MIST-PS8 (POWER UNIT) CONFIGURATIONS ................................................................................................................................................................. 12
RETURNS PROCEDURE ..................................................................................................................................................................................................12
CLAIMS .........................................................................................................................................................................................................................12
TECHNICAL SPECIFICATIONS .......................................................................................................................................................................................... 13
TECHNICAL SUPPORT ....................................................................................................................................................................................................13
COLORmist System User Manual 2 2005-10-10/18:36
MIST-
PS8 AC Voltage Switch

BEFORE YOU BEGIN

COLORmist System

Your COLORmist LED color system may include either of the two packages listed;
SYS-PAR4, PAR Pack System SYS-PANEL2, Panel Pack System
1 x MIST-CON, Controller 1 x MIST-CON, Controller 4 x MIST-PAR80, Par Can 2 x MIST-PANEL, Panel 1 x MIST-PS8, Power Unit 1 x MIST-PS8, Power Unit 1 x MIST-CBL33, Power/Signal Cable 33 1 x MIST-CBL33, Power/Signal Cable 33 4 x MIST-CBL5, Power/Signal Cable 5 2 x MIST-CBL5, Power/Signal Cable 5 User Manual & Warranty Card User Manual & Warranty Card

Unpacking Instructions

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.

AC Power

To determine the power requirements for a particular product, see the label affixed to the back plate of the product or refer to the products specifications chart. A products listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power, check that the source voltage matches the products requirement. Check the product or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use.
Warning! If applicable, verify that the power select switch on your unit matches the line
voltage applied. All fixtures must be connected to circuits with a suitable Earth Ground.

Safety Instructions

Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive this instruction booklet.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture.
This product is intended for indoor use only!  To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same lamp source.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
Dont connect the device to a dimmer pack. Make sure power cord is never crimped or damaged.  Never disconnect power cord by pulling or tugging on the
cord.
COLORmist System User Manual 3 2005-10-10/18:36

INTRODUCTION

Features

COLORmist (MIST-PAR80) COLORmist Panel (MIST-PANEL)
80 LEDs per surface
- Red (27), Green (27) and Blue (26)
Ultra bright LED's Stand alone color change programs using
(COLORmist Power unit)
7 static colors, 13 color pattern chase programs with
adjustable speeds, auto run, sound active mode and RGB Mix via (MIST-CON COLORmistTM Controller)
Low power consumption and heat generation No infra-red or UV emissions Up to 100,000-hour LED life span Master/Slave mode (requires COLORmist Power unit) MIST-PAR80 and MIST-PANEL require the
COLORmist Power unit for operation
Also links with COLORmist Panel
72 LEDs per Panel, distributed into 4 square sections
with 18 LEDs each
- Red (24), Green (24) and Blue (24)
Ultra bright LED's Stand alone color change programs using
(COLORmist Power unit)
7 static colors, 13 color pattern chase programs with
adjustable speeds, auto run, sound active mode and RGB Mix via (MIST-CON COLORmistTM Controller)
Low power consumption and heat generation No infra-red or UV emissions Up to 100,000-hour LED life span Master/Slave mode (requires COLORmist Power unit) MIST-PAR80 and MIST-PANEL require the
COLORmist Power unit for operation
Also links with COLORmist
COLORmist Controller (MIST-CON)
CONTROL FEATURES
4 channel DMX controlled (controller device)  7 independently selectable preset colors, 13
programmed chases adjustable in speed or flash rate, Auto mode, Sound Active and RGB Mix control mode
Select quantity of fixtures  Speed, Flash or Chase control channel
FEATURES
Built in Microphone  Digital LCD display

MIST-CON DMX Channel Summary

CHANNEL FUNCTION
1
2
3
4
Program mode
Red / Run Speed
Green / Flash Speed
Blue / Select Color
COLORmist System User Manual 4 2005-10-10/18:36
Loading...
+ 9 hidden pages