USER MANUAL .............................................................................................................................................. 1
1. Before You Begin ...................................................................................................................................... 3
What is included .............................................................................................................................................. 3
AC Power ........................................................................................................................................................ 3
Contact Us ...................................................................................................................................................... 3
Features .......................................................................................................................................................... 5
Data Cabling ................................................................................................................................................... 7
DMX Data Cable ............................................................................................................................................. 7
Navigating the Control Panel ........................................................................................................................ 10
Menu Map ..................................................................................................................................................... 11
User Configurations ...................................................................................................................................... 12
To set the pan to inverting or non-inverting: .................................................................................................. 12
To set the tilt to inverting or non-inverting: .................................................................................................... 12
To set the LED Readout to Inverting or Non-Inverting: ................................................................................. 12
To set the DMX channel configuration: ......................................................................................................... 12
To set the maximum pan angle: .................................................................................................................... 12
To set the maximum tilt angle: ...................................................................................................................... 12
Service Functions ......................................................................................................................................... 12
To reset the fixture: ....................................................................................................................................... 12
To restore all settings to their factory defaults: .............................................................................................. 12
Technical Support ......................................................................................................................................... 17
DMX Primer .................................................................................................................................................. 17
General Maintenance .................................................................................................................................... 18
¾ 1 x MiN™ Spot
¾ Power Cord
¾ Warranty Card
¾ User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the
source voltage matches the fixture’s requirement. Check the fixture or
device carefully to make sure that if a voltage selection switch exists that it
is set to the correct line voltage you will use.
Warning! Verify that the voltage select switch on your unit matches the
line voltage applied. Damage to your fixture may result if the
line voltage applied does not match the voltage indicated on
the voltage selector switch. All fixtures must be connected to
circuits with a suitable Earth Ground.
Contact Us
Figure 1 - AC Voltage Switch
Not all fixtures have a voltage
select switch. Please be sure to
connect to the proper voltage.
Please read these instructions carefully, it includes important
information about the installation, usage and maintenance of this
product.
•Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
•Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
• This product is intended for indoor use only!
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
•The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
•Always disconnect from power source before servicing or replacing fuse and be sure to replace with
same fuse size and type.
•Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use
its carrying handles.
•Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher
than this.
•In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
• Don’t connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET at: 954-929-1115.
MiN™ Spot User Manual 4 2008-07-15/12:39
Page 5
2.INTRODUCTION
Features
CONTROL FEATURES
• 5 or 13-channel DMX-512 LED moving yoke
• Pan: 540
• RGB color mixing
• Gobo wheel
• Variable electronic strobe
• Variable electronic dimmer (0 – 100%)
• Vector speed channel for pan/tilt, RGB color mixing and color macros
• Built-in movement macros via master/slave or DMX
ADDITIONAL FEATURES
• User-selectable basic or advanced operating modes
• User-selectable pan/tilt ranges
• Compact and lightweight
• LED display menu with invert
• Reset to factory settings option
• Display auto on/off
• Pan/tilt invert option
• Fan cooled
OPTIONAL CONTROLLERS
•Easy Controller (CA-9)
o
/ tilt: 270o
9 gobos + open
Gobo wheel spin effect
Pan: 540°, 360°, 180°
Tilt: 270°, 180°, 90°
DMX Channel Summary - 13 Channel Mode
CHANNEL FUNCTION
1
2
3
4
5
6
7
8
9
10
11
12
13
Pan
Pan Fine
Tilt
Tilt Fine
Vector Speed (Pan/Tilt)
Dimmer/Strobe
Red
Green
Blue
Color Macros
Vector Speed (Color)
Movement Macros
Gobo
MiN™ Spot User Manual 5 2008-07-15/12:39
Page 6
DMX Channel Summary - 5 Channel Mode
(
)
(
)
CHANNEL FUNCTION
1
2
3
4
5
Pan
Tilt
Shutter
Color Macro
Gobo
Product Overview
Projector Head
Focus
Control
Panel
IEC Power
Connector with
Fuse holder
(Rear)
DMX InDMX Out
Voltage Selector
Switch
rear
Lens
LED
Readout
CA-9
Controller
Input
rear
MiN™ Spot User Manual 6 2008-07-15/12:39
Page 7
3.SETUP
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
Fuse Replacement
With a flat head screwdriver wedge the fuse
holder out of its housing. Remove the damaged
fuse from its holder and replace with exact
same type fuse. Insert the fuse holder back in
its place and reconnect power.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a serial data link determines the number
of fixtures the data link can support.
Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
standard no more than 32 devices should be connected on one data link. Connecting more than 32
fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in
deterioration of the digital DMX signal.
To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less prone to
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will
have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
MiN™ Spot User Manual 7 2008-07-15/12:39
Page 8
CABLE CONNECTORS CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end. Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
INPUT
3
2
CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to
verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
1
DMX
+
-
3-PIN TO 5-PIN CONVERSION CHART 3-PIN TO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
CHAUVET Model No: DMX5M, or DMX5F.
CHAUVET Model No: DMX5M, or DMX5F.
The chart below details a proper cable conversion:
The chart below details a proper cable conversion:
PIN TO 5PIN CONVERSION CHART 3PIN TO 5PIN CONVERSION CHART
3
Conductor Conductor 3 Pin Female (output) 3 Pin Female (output) 5 Pin Male (Input) 5 Pin Male (Input)
Ground/Shield Pin 1 Pin 1
Data ( - ) signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3
Do not use Do not use
Do not use Do not use
1
3
2
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
1
OUTPUT
3
Termination reduces signal errors. To
2
avoid signal transmission problems
and interference, it is always
advisable to connect a DMX signal
terminator.
Setting up a DMX Serial Data Link
Universal DMX Controller
1. Connect the (male) 3 pin connector side of
the DMX cable to the output (female) 3 pin
connector of the controller.
2. Connect the end of the cable coming from
the controller which will have a (female) 3
pin connector to the input connector of the
next fixture consisting of a (male) 3 pin
connector.
This drawing provides a
general illustration of the
DMX Input/Output panel of
a lighting fixture.
3. Then, proceed to connect from the output
as stated above to the input of the following
fixture and so on.
CHAUVET Certified DMX Data Cables
Order Code Description
DMX1.5 DMX Cable 1.5m/4.9ft
DMX4.5 DMX Cable 4.5m/14.8ft
DMX10 DMX Cable 10m/32.8ft
Continue the link
MiN™ Spot User Manual 8 2008-07-15/12:39
Page 9
Master/Slave Fixture Linking
y
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave
and Standalone operation requires
that the first fixture in the cha in be
initialized for this purpose via either
settings in the control panel or DIPswitches. Secondarily, the fixtures
that follow may also require a slave
setting. Please consult the
“Operating Instructions” section in
this manual for complete ins tructions
for this type of setup and
configuration.
Mounting
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
RIGGING
It is important never to obstruct the fan or vents pathway. Mount the
fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the
fixture by loosening both knobs and tilting the fixture. After finding the
desired position, retighten both knobs.
•When selecting installation location, take into consideration lamp
replacement access and routine maintenance.
• Safety cables must always be used.
• Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
Hanging Clamp
Note!
Clamp is sold separatel
.
MiN™ Spot User Manual 9 2008-07-15/12:39
Page 10
4.OPERATING INSTRUCTIONS
Navigating the Control Panel
Access control panel functions using the four panel buttons located directly underneath the LCD
Display.
Button Function
<MODE/ESC>
<UP>
<DOWN>
<ENTER>
The Control Panel LED Display shows the menu items you select from the menu map on page #11.
When a menu function is selected, the display will show immediately the first available option for the
selected menu function. To select a menu item, press <ENTER>.
Press the <MODE/ESC> button repeatedly until you reach the desired menu function. Use the <UP>
and <DOWN> buttons to navigate the menu options. Press the <ENTER> button to select the menu
function currently displayed, or to enable a menu option. To return to the previous option or menu
without changing the value, press the <MODE/ESC> button.
Used to access the menu or to return to a
previous menu option
Scrolls through menu options in ascending
order
Scrolls through menu options in descending
order
Used to select and store the current menu
or option within a menu
MODE/ESC UP DOWN ENTER
MiN™ Spot User Manual 10 2008-07-15/12:39
Page 11
Menu Map
MiN™ Spot User Manual 11 2008-07-15/12:39
Page 12
User Configurations
TO SET THE PAN TO INVERTING OR NON-INVERTING:
1) Press the Mode button until it shows or
2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
TO SET THE TILT TO INVERTING OR NON-INVERTING:
1) Press the Mode button until it shows or
2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
TO SET THE LED READOUT TO INVERTING OR NON-INVERTING:
1) Press the Mode button until it shows or
2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
TO SET THE DMX CHANNEL CONFIGURATION:
1) Press the Mode button until it shows or
2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
TO SET THE MAXIMUM PAN ANGLE:
1) Press the Mode button until it shows or or
2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
TO SET THE MAXIMUM TILT ANGLE:
1) Press the Mode button until it shows or or
2) Use the Up/Down buttons to set to the desired inversion, press enter to confirm.
Service Functions
TO RESET THE FIXTURE:
1) Press the Mode button until the display shows
2) Press enter to confirm your selection.
TO RESTORE ALL SETTINGS TO THEIR FACTORY DEFAULTS:
1) Press the mode button until the display reads
2) Press enter to confirm your selection.
MiN™ Spot User Manual 12 2008-07-15/12:39
Page 13
Stand-Alone Mode (Auto Mode):
This mode allows a single unit to run to a factory installed program in one of two speeds.
1) To set the fixture in auto mode Fast, select . Once confirmed the display reads
2) To set the fixture in auto mode Slow, select Once confirmed the display reads
Master/Slave Mode (Master Sound):
This mode will allow you to link up to 32 units together without a controller.
1) Use standard DMX cables to daisy chain your units together via the DMX connector on the rear
of the units. Proper performance it may be necessary to use a terminator at the last fixture. For
more information about terminators, see page 8.
2) Choose a unit to function as the Master. Select NAFA/NASL or NStS (see below for readout)
depending upon which master mode you require. The master unit must be the first unit in line.
Finally, chain the units together using DMX cable.
Master Auto or
Master Sound becomes when confirmed
3) Select slave function by using the Up/Down keys to reach SLAv in the Master/Auto menu on the
slave units, and they will react in the same as the Master.
Slave becomes when confirmed
Easy Controller Mode:
This mode allows users to control the MiN Spot with the easy controller.
1) To place the unit in easy controller mode, select
2) In Easy controller mode, the fixture will react as follows:
4)
BUTTON DESCRIPTION
Stand By Blacks out the unit.
Function First click: strobe on. Second click: strobe off.
Mode
First click: sound-active mode (LED will be on). Second click: auto mode (LED will be
off).
DMX Mode
This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with
DMX, please read the DMX Primer on page #17.
1) The default mode for the fixture is DMX, which appears as on the LED Readout.
No Function
White
Red
Green
Blue
Cyan
Magenta
Yellow
Purple
Orange
Chartreuse
Pink
Brown
Gold
Crimson
Violet
Crepe
Color-Change Macro 1
Color-Change Macro 2
Movement Macros
No Function
Auto Program 1
Auto Program 2
Auto Program 3
Auto Program 4
Auto Program 5
Auto Program 6
Auto Program 7
Auto Program 8
Sound Active1
Sound Active 2
Sound Active 3
Sound Active 4
Sound Active 5
Sound Active 6
Sound Active 7
Sound Active 8
No Function
White
Red
Green
Blue
Cyan
Magenta
Yellow
Purple
Orange
Chartreuse
Pink
Brown
Gold
Crimson
Violet
Crepe
Color-Change Macro 1
Color-Change Macro 2
Gobo
0~12
65~77
Scrolling Gobo Effect slow → fast
13~25
78~90
26~38
91~103
39~51
104~116
52~64
117~127
MiN™ Spot User Manual 15 2008-07-15/12:39
Page 16
Troubleshooting
Applies to
Symptom Solution(s)
Auto shut off Check fan thermal switch reset
Beam is very dim or
not bright
Breaker/Fuse keeps
blowing
Chase is too slow Check users manual for speed adjustment
Device has no power Check for power on Mains.
Fixture is not
responding
Fixture is on but
there is no
movement to the
audio
Lamps cuts off
sporadically
Light will not come
on after power failure
Loss of signal Use only DMX cables
Moves slow Check 220/110v switch for proper setting
Clean optical system or replace lamp
Check 220/110v switch for proper setting
Make sure you have the correct audio mode on the
control switches. If audio provided via ¼” jack, make
sure a live audio signal exists
Adjust sound sensitivity knob
Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.
Some discharge lamps require a cooling off period
before the electronics in the fixture can kick start it
again, wait 5 to 10 minutes before powering up
Install terminator
Note: Keep DMX cables separated from power cables
or black lights.
Foggers
Lights
& Snow Controllers
9
9
Dimmers
& Chaser
9
9
9
9 9
9 9
9
9
9
9 9
9 9 9 9
9
9
No flash Re-install bulb, may have shifted in shipping
No laser output Bounce mirror motor may have shifted during shipping,
readjust
No light output Check slip ring & brushes for contact
Install bulb
Call service technician
Relay will not work Check reset switch
Check cable connections
Remote does not
work
Stand alone mode All Chauvet lighting fixtures featuring stand-alone
MiN™ Spot User Manual 16 2008-07-15/12:39
Make sure connector is firmly connected to device
functions do not require additional settings, simply
power the fixture and it will automatically enter into this
mode
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
Support at the location on the next page.
9
9
9
9 9
9
9
Page 17
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): tech@chauvetlighting.com
Telephone: (954) 929-1115 - (Press 4)
Fax: (954) 929-5560 - (Attention: Service)
Website: http://www.chauvetlighting.com
APPENDIX
6.
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
Power Consumption .................................................................................... 68.1W (0.60A) Max at 120V
Inrush Power ............................................................................................ 83.6W (1.41A) inrush at 120V
Power Factor ..................................................................................................................................... 0.92
LIGHT SOURCE
LED ..................................................................................................................... 1, 14W RGB 50,000hrs
Luminance at 1M ........................................................................................................... 100fc (1,076 lux)
RANGE
Pan ................................................................................................................................................... 540°