Chauvet Mayhem User Manual

Page 1
Snapshot
Use on Dimmer
Outdoor Use
Sound Activated
DMX
Master/Slave
Autoswitching
Power Supply
Replaceable Fuse
User Serviceable
Duty Cycle
User Manual
3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENTS
1. BEFORE YOU BEGIN ................................................................................................................................................... 3
WHAT IS INCLUDED ................................................................................................................................................................................ 3
UNPACKING INSTRUCTIONS .................................................................................................................................................................... 3
MANUAL CONVENTIONS ......................................................................................................................................................................... 3
ICONS .................................................................................................................................................................................................. 3
SAFETY INSTRUCTIONS .......................................................................................................................................................................... 4
2. INTRODUCTION ........................................................................................................................................................... 5
FEATURES ............................................................................................................................................................................................ 5
ADDITIONAL FEATURES .......................................................................................................................................................................... 5
PRODUCT DIMENSIONS .......................................................................................................................................................................... 5
PRODUCT OVERVIEW............................................................................................................................................................................. 6
3. SETUP .......................................................................................................................................................................... 7
AC POWER........................................................................................................................................................................................... 7
Power Linking ........................................................................................................................................................... 7
MOUNTING............................................................................................................................................................................................ 8
Orientation ................................................................................................................................................................ 8
Rigging ..................................................................................................................................................................... 8
4. OPERATING INSTRUCTIONS ...................................................................................................................................... 9
DMX Operation ......................................................................................................................................................... 9
Master/Slave Mode (Sound-Active, Auto Mode, Static Colors) .................................................................................. 9
STANDALONE OPERATION .................................................................................................................................................................... 10
Automatic ................................................................................................................................................................ 10
Sound-Active .......................................................................................................................................................... 10
Custom Program ..................................................................................................................................................... 10
DMX CHANNEL VALUES ...................................................................................................................................................................... 11
5. APPENDIX .................................................................................................................................................................. 12
DMX PRIMER ..................................................................................................................................................................................... 12
GENERAL MAINTENANCE...................................................................................................................................................................... 12
NEVER SPIN A FAN USING COMPRESSED AIR. .......................................................................................................................................... 12
FIXTURE LINKING................................................................................................................................................................................. 13
Data Cabling ........................................................................................................................................................... 13
DMX Data Cable ..................................................................................................................................................... 13
Cable Connectors ................................................................................................................................................... 13
3-Pin to 5-Pin Conversion Chart .............................................................................................................................. 14
Setting up a DMX Serial Data Link .......................................................................................................................... 14
SETTING THE STARTING ADDRESS ........................................................................................................................................................ 15
GENERAL TROUBLESHOOTING .............................................................................................................................................................. 15
CONTACT US ...................................................................................................................................................................................... 15
RETURNS PROCEDURE ........................................................................................................................................................................ 16
CLAIMS .............................................................................................................................................................................................. 16
TECHNICAL SPECIFICATIONS ................................................................................................................................................................ 17
Page 3
1. BEFORE YOU BEGIN
CONVENTION
MEANING
[10]
A DIP switch to be configured
<Menu>
A key to be pressed on the fixture’s control panel
1~512
A range of values
50/60
A set of values of which only one can be chosen
Settings
A menu option not to be modified (for example, showing the operating mode/current status)
MENU > Settings
A sequence of menu options to be followed
ON
A value to be entered or selected
ICONS
MEANING
This paragraph contains critical installation, configuration or operation information. Failure to comply with this information may render the fixture partially or completely inoperative, cause damage to the fixture or cause harm to the user.
This paragraph contains important installation or configuration information. Failure to comply with this information may prevent the fixture from functioning correctly.
This paragraph reminds you of useful, although not critical, information.
What is included
1 x Mayhem™ 1 x Power cable 1 x Warranty Card
Unpacking Instructions
Manual Conventions
1 x User Manual
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text.
Icons
This manual uses the following icons to indicate information that requires special attention on the part of the user.
1. Before You Begin 3 11/13/2009 3:17 PM
Page 4
Safety Instructions
Please read these instructions carefully. It includes important information about the installation, usage and maintenance of this product.
Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable materials close to the unit while operating. The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked. Always disconnect from power source before servicing or replacing fuse and be sure to replace with
same fuse source. Secure fixture to fastening device using a safety chain. Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher
than this. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Never connect the device to a dimmer pack. Make sure the power cord is never crimped or damaged. Never disconnect the power cord by pulling or tugging on the cord. Never carry the fixture directly from the cord. Always use the hanging/mounting bracket. Avoid direct eye exposure to the light source while it is on.
1. Before You Begin 4 11/13/2009 3:17 PM
Page 5
2. INTRODUCTION
Features
7-channel DMX-512 dual rotating LED scanner Individual control of red, green and blue LEDs for each side (with strobing) Individual control of motor direction and speed for each side Instantly set motors and/or LEDs into sound activated programs Built-in automated programs via master/slave or DMX Built-in sound activated programs via master/slave or DMX
Additional Features
High-power, 3 W (700 mA) LEDs Additional power output: max 25 units
Product Dimensions
2. Introduction 5 11/13/2009 3:17 PM
Page 6
Safety
DMX In
Power Input
(IEC)
Microphone
Audio
Adjustment
Knob
Fuseholder
Light Output
Bracket Adjustment Knob
DMX Out
Power Output
(Edison)
Bracket Adjustment Knob
DIP switches
Product Overview
2. Introduction 6 11/13/2009 3:17 PM
Page 7
Additional
power link
Fixture #1
Fixture #1
Fixture #1
3. SETUP
AC Power
This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line voltage
to which you are connecting it is within the range of accepted voltages.
Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0
to 100% switch.
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating indicates its
average current draw under normal conditions.
Always connect the fixture to a circuit with a suitable electrical ground.
Power Linking
This fixture contains power linking via the edison outlet located in front of the power input cable.
Please see the diagram below for further explanation.
The maximum quantity of fixtures that may be linked is 25.
4. Operating Instructions 7 11/13/2009 3:17 PM
Page 8
Rotating mirror
(1 of 2)
Mounting
Bracket
Bracket
Adjustment knob
Mounting
Orientation
The Mayhem may be mounted in any safe position, provided there is adequate room for ventilation.
Rigging
Be sure that the structure can support the weight of the fixture. Please see the “Technical
Specifications” section of this manual for a detailed weight listing. Mount the fixture
securely. This may be done with a screw, nut and bolt, or a hanging clamp. The hole in each bracket is 13 mm in size. When rigging, consider routine maintenance and DIP switch access. Please see the following steps for installation.
If the power link out is intended to be used with multiple fixture, take into account the
length of each power cable, and mount the fixtures close enough to one another to accommodate for this.
When aiming the fixtures, you may use the bracket adjustment knob. Loosen the
knob, adjust to the desired angle, and then tighten the knob by turning clockwise. Do not use tools for this step, as it may cause damage.
Safety cables must always be used.
4. Operating Instructions 8 11/13/2009 3:17 PM
Page 9
4. OPERATING INSTRUCTIONS
DMX Operation
Master/Slave Mode (Sound-Active, Auto Mode, Static Colors)
This is the operating mode which will allow for control with an external DMX controller. You must set
the starting address for this mode. If this is your first time using DMX, then it is recommended that
you refer to the “DMX Primer” section in the “Appendix” of this manual.
The fixture will automatically switch to DMX operating mode when a DMX controller is plugged into
the fixture.
Mode DIP switches
DMX 1~9 = set to the DMX starting address
This mode allows a single unit to run a standalone program, while 1 or more other units follow the
same operation. This requires the fixtures to be linked with DMX cables. Please see the section on
Fixture Linking.
1) Turn switch to the Slave position on the slave units, and they will react the same as the Master. The Master can be set to either Automatic or Sound-Active mode.
Mode DIP switches
Slave 1~10 = Off
4. Operating Instructions 9 11/13/2009 3:17 PM
Page 10
Standalone Operation
Automatic
Sound-Active
Custom Program
This fixture has a preprogrammed color fade program. This is accessed via the DIP switches on the back of the fixture, and the speed may be adjusted, as well. Please see the chart below for further explanation.
Mode DIP switches Master Auto 9 = On
This fixture has preprogrammed sound triggered chases. These are accessed via the DIP switches on the back of the fixture, and the sensitivity may be adjusted using the audio adjustment knob. Please see the chart below for further explanation.
Mode DIP switches Master Sound 8 = On
You may combine functions together to create a desired look. These are accessed via the DIP switches on the back of the fixture, and the sensitivity may be adjusted using the audio adjustment knob. Please see the chart below for further explanation.
Mode DIP switches Red 1 = On Green 2 = On Blue 3 = On Strobe Speed 1 4 = On Strobe Speed 2 5 = On Strobe Speed 3 6 = On Strobe Speed 4 7 = On Reverse Motors 10 = On
.
4. Operating Instructions 10 11/13/2009 3:17 PM
Page 11
DMX Channel Values
CHANNEL
VALUE
FUNCTION
1
000 020 021 040 041 060 061 080 081 100 101 120 121 140 141 160 161 180 181 200 201 220 221 240 241 255
Mode
Static Color Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 Mode 6 Mode 7 Mode 8 Mode 9 Mode 10 Mode 11 Sound
2
000 009 010 255
Strobe
No function Slow fast
3
000 009 010 255
Run Speed
No function Slow fast
4
(POD 1)
000 020 021 040 041 060 061 080 081 100 101 120 121 140 141 255
Static Color
No function Red Green Blue Red/Green Red/Blue Green/Blue Red/Green/Blue
5
(POD 2)
6
(POD 1)
000 020 021 040 041 060 061 080 081 100 101 120 121 140 141 160 161 180 181 200 201 220 221 240 241 255
Motor Rotation
Static Color (clockwise) speed 1 (slowest) (clockwise) speed 2 (clockwise) speed 3 (clockwise) speed 4 (clockwise) speed 5 (fastest) No rotation (counter-clockwise) speed 1 (slowest) (counter-clockwise) speed 2 (counter-clockwise) speed 3 (counter-clockwise) speed 4 (counter-clockwise) speed 5 (fastest) Sound
7
(POD 2)
4. Operating Instructions 11 11/13/2009 3:17 PM
Page 12
5. APPENDIX
DMX Primer
There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture capable of receiving DMX will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+).
General Maintenance
To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external
vents.
Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl
Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint.
The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. Clean the external optics at least every 20 days. Clean the fixture at least every 30/60 days.
Always dry the parts carefully after cleaning them.
Never spin a fan using compressed air.
5. Appendix 12 11/13/2009 3:17 PM
Page 13
COMMON
DMX +
DMX -
INPUT
OUTPUT
1 3 2
1
3
2
1
3
2
120 ohm ¼ W resistor between pin 2 (DMX -) and pin 3 (DMX +) on the output of the last fixture
To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.
DMX connector configuration
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA­485 standard, no more than 32 fixtures should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 m (1640 ft) Maximum recommended number of fixtures on a serial data link: 32
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.
DMX Data Cable
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must have the following characteristics:
Type: shielded, 2-conductor twisted pair Maximum capacitance between conductors: 30 pF/ft Maximum capacitance between conductor and shield: 55 pF/ft Maximum resistance: 20 ohms/1000 ft Nominal impedance: 100 ~ 140 ohms
Cable Connectors
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
5. Appendix 13 11/13/2009 3:17 PM
Page 14
This drawing provides a general illustration of the DMX input/output panel of a lighting fixture.
Universal DMX Controller
Continue the link
3-Pin to 5-Pin Conversion Chart
3-PIN TO 5-PIN CONVERSION CHART
Conductor
3-Pin Female (Output)
5-Pin Male (Input)
Ground/Shield
Pin 1
Pin 1
Data ( - ) signal
Pin 2
Pin 2
Data ( + ) signal
Pin 3
Pin 3
Not used
Pin 4
Not used
Pin 5
If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to 3-pin adapter. The chart below details a proper cable conversion:
Setting up a DMX Serial Data Link
1. Connect the (male) 3-pin connector side of the DMX cable to the output (female) 3-pin connector of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3-pin connector to the input connector of the next fixture consisting of a (male) 3-pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
5. Appendix 14 11/13/2009 3:17 PM
Page 15
Setting the Starting Address
SYMPTOM
POSSIBLE CAUSE(S)
POSSIBLE ACTION(S)
Breaker/Fuse
keeps blowing
Excessive circuit load
Check total load placed on the electrical circuit.
Short circuit along the power
wires
Check for a short in the electrical wiring (internal and/or
external).
Device does not
power up
No power
Check for power on Mains.
Loose power cord
Check power cord
Fixture is not
responding to
DMX
Wrong DMX addressing
Check Control Panel and unit addressing
Damaged DMX cables
Check DMX cables
Wrong polarity settings on the
controller
Check polarity switch settings on the controller Loose DMX cables
Check cable connections
Faulty DMX interface
Replace DMX input
Faulty Main PCB
Replace Main PCB
Loss of signal
Non DMX cables
Use only DMX compatible cables
Bouncing signals
Install terminator as suggested.
Long cable / Low level signal
Install amplifier right after fixture with strong signal.
Too many fixtures
Install an optically coupled DMX splitter after unit #32.
Interference from AC wires
Keep DMX cables separated from power cables or
black lights.
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap, and note the start address selected for future reference.
If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping to the
“Appendix” section and reading the heading “DMX Primer”. It contains very useful information that will help you
understand its use.
General Troubleshooting
If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support.
Contact Us
World Wide
5. Appendix 15 11/13/2009 3:17 PM
General Information CHAUVET
Technical Support CHAUVET
World Wide Web www.chauvetlighting.com
3000 North 29th Court Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
3000 North 29th Court Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
Page 16
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing; call tags will not be issued. Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). Products returned without the RMA # will be refused. Call CHAUVET and request an RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to pack fixture properly; any shipping damage resulting from
inadequate packaging is the customer’s responsibility. As a suggestion, proper UPS packing or
double-boxing is always a safe method to use.
CHAUVET reserves the right to use its own discretion to repair or replace product(s).
If you are given an RMA #, please include the following information on a piece of paper inside the box:
1) Your name
2) Your address
3) Your phone number
4) The RMA #
5) A brief description of the symptoms
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore, the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.
5. Appendix 16 11/13/2009 3:17 PM
Page 17
Technical Specifications
WEIGHT & DIMENSIONS
Length .......................................................................................................................... 8.2 in (208 mm)
Width.......................................................................................................................... 17.3 in (439 mm)
Height ............................................................................................................................. 8 in (203 mm)
Weight.............................................................................................................................. 6 lbs (2.7 kg)
POWER
Autoswitching Power Supply ........................................................................... 100~240 VAC, 50/60 Hz
Power Consumption @ 120 VAC, 60 Hz ...............................................31 W (0.4 A) max, 0.4 A inrush
Power Consumption @ 230 VAC, 50 Hz ...............................................31 W (0.4 A) max, 0.3 A inrush
Power output ..................................................................................................................... 25 units max
Fuse .................................................................................................................................. T 2 A, 250 V
LIGHT SOURCE
LED ........................................................................ 6 (2 red, 2 green, 2 blue) 3 W, 700 mA, 50,000 hrs
PHOTO OPTIC
Coverage Angle .............................................................................................................................. 79°
THERMAL
Maximum ambient temperature ...................................................................................... 104° F (40° C)
ORDERING INFORMATION
Mayhem™............................................................................................................................. MAYHEM
WARRANTY INFORMATION
Warranty ........................................................................................................... 2-year limited warranty
Technical Specifications 17 11/13/2009 3:17 PM
Loading...