Chauvet led par 38 tri-b, led par 38 tri-c User Manual

Page 1
LED PAR 38 TRI-B
Snapshot
LED PAR 38 TRI-C
User Manual
Use on Dimmer
Outdoor Use
Sound Activated
DMX
Master/Slave
Autoswitching
Power Supply
Replaceable Fuse
User Serviceable
Duty Cycle
5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENTS
1. BEFORE YOU BEGIN ....................................................................................................................................................... 3
WHAT IS INCLUDED ................................................................................................................................................................................ 3
UNPACKING INSTRUCTIONS .................................................................................................................................................................... 3
MANUAL CONVENTIONS ......................................................................................................................................................................... 3
ICONS .................................................................................................................................................................................................. 3
SAFETY INSTRUCTIONS .......................................................................................................................................................................... 4
2. INTRODUCTION ............................................................................................................................................................... 5
FEATURES ............................................................................................................................................................................................ 5
PRODUCT DIMENSIONS .......................................................................................................................................................................... 5
PRODUCT OVERVIEW ............................................................................................................................................................................ 5
3. SETUP ............................................................................................................................................................................... 6
AC POWER........................................................................................................................................................................................... 7
Power Linking ............................................................................................................................................................... 7
Orientation .................................................................................................................................................................... 8
Rigging .......................................................................................................................................................................... 8
FIXTURE LINKING .................................................................................................................................................................................. 9
DATA CABLING ...................................................................................................................................................................................... 9
4. OPERATING INSTRUCTIONS.......................................................................................................................................... 9
CONFIGURING THE STARTING ADDRESS .................................................................................................................................................. 9
CONTROL PANEL FUNCTIONS ................................................................................................................................................................. 9
MENU MAP ......................................................................................................................................................................................... 10
DMX OPERATION ............................................................................................................................................................................... 10
MASTER/SLAVE .................................................................................................................................................................................. 10
STANDALONE OPERATION .................................................................................................................................................................... 11
Automatic .................................................................................................................................................................... 11
Sound-Active ............................................................................................................................................................... 11
Preset Colors .............................................................................................................................................................. 11
Custom Static Color Mixing......................................................................................................................................... 11
Fixture Linking ............................................................................................................................................................. 12
5. APPENDIX ....................................................................................................................................................................... 14
GENERAL MAINTENANCE ..................................................................................................................................................................... 14
SETTING THE STARTING ADDRESS ........................................................................................................................................................ 14
GENERAL TROUBLESHOOTING .............................................................................................................................................................. 15
RETURN PROCEDURE .......................................................................................................................................................................... 15
CLAIMS .............................................................................................................................................................................................. 15
TECHNICAL SPECIFICATIONS ................................................................................................................................................................ 16
CONTACT US ...................................................................................................................................................................................... 16
Page 3

1. BEFORE YOU BEGIN

What is Included

1 x LED PAR 38 Tri-B/C 1 x Gel Frame 1 x Warranty Card 1 x User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Manual Conventions
CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text.
Icons
CONVENTION
[10] A DIP switch to be configured
<Menu> A key to be pressed on the fixture’s control panel
1~512 A range of values
50/60 A set of values of which only one can be chosen
Settings
MENU > Settings A sequence of menu options to be followed
ON A value to be entered or selected
This manual uses the following icons to indicate information that requires special attention on the part of the user.
ICONS
A menu option not to be modified (for example, showing the operating mode/current status)
This paragraph contains critical installation, configuration or operation information. Failure to comply with this information may render the fixture partially or completely inoperative, cause damage to the fixture or cause harm to the user.
This paragraph contains important installation or configuration information. Failure to comply with this information may prevent the fixture from functioning correctly.
This paragraph reminds you of useful, although not critical, information.
MEANING
MEANING
LED PAR 38-Tri B&C User Manual 3 Rev. 2
Page 4

Safety Instructions

Please read these instructions carefully. It includes important product.
information about the installation, usage and maintenance of this
Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture.
This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to rain or moisture.
Make sure there are no flammable materials close to the unit while operating.
The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source.
Secure fixture to fastening device using a safety chain.
Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher
than this.
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center.
Never connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Never carry the fixture directly from the cord. Always use the hanging/mounting bracket.
Avoid direct eye exposure to the light source while it is on.
LED PAR 38-Tri B&C User Manual 4 Rev. 2
Page 5

2. INTRODUCTION

Features

3 or 7-channel DMX-512 tri-color LED PAR can
Operating modes:
Static colors and RGB color mixing with or without DMX controller
Built-in automated programs via master/slave or DMX with variable speed
Built-in sound activated programs via master/slave or DMX
Pulse effect with adjustable speed
Additional Features
Available in black or chrome
Tri-color LEDs for superior color mixing (1,050mA total)
Additional power output: max 16 units
Double-bracket yoke doubles as floor stand
Includes gel frame
Product Dimensions
3-channel: RGB control 7-channel: RGB, macros, run speed, strobe, automatic/sound, dimmer
LED PAR 38-Tri B&C User Manual 5 Rev. 2
Page 6
Product Overview
Power Output
Control Panel
DMX In
Power Input
Power Input
(Hardwired)
Microphone
Audio
Knob
Fuseholder
Gel Frame
Gel Frame Release
Bracket Adjustment
Knob
Bracket Adjustment Knob
Attachment Bolt
be adjusted)
DMX Out
Light Output
Power Output
(Edison)
Safety
Hanging/mounting (13 mm hole)
(not meant to
Adjustment
attachment point
(Hardwired)
LED PAR 38-Tri B&C User Manual 6 Rev. 2
Page 7
3. SETUP
Additional power

AC Power

This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line voltage to which you are connecting it is within the range of accepted voltages.
Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 to 100% switch.
To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating indicates its average current draw under normal conditions.
Always connect the fixture to a circuit with a suitable electrical ground.
Power Linking
This fixture contains power linking via the edison outlet located in front of the power input cable. Please see the diagram below for further explanation.
The maximum quantity of fixtures that may be linked is 16.
link out
LED PAR 38-Tri B&C User Manual 7 Rev. 2
Page 8
Do not use a tool
Mounting
Bracket
Secondary bracket
standing position)
Aim the fixture with
diagram)
Mounting
Orientation
The LED PAR 38 Tri-B/C may be mounted in any safe position provided there is adequate room for ventilation.
Rigging
Be sure that the structure can support the weight of the fixture. Please see the “Technical Specifications” section of this manual for a detailed weight listing. Mount the fixture securely. This may be done with a screw, nut and bolt, or a hanging clamp. The hole in each bracket is 13 mm in size. When rigging consider routine maintenance and control panel access. Please see the following steps for installation.
Be sure to orient the gel frame release so that it is pointing up. Please see the diagram below for a visual reference.
If the power link out is intended to be used with multiple fixture, take into account the length of each power cable, and mount the fixtures close enough to one another to accommodate for this.
When aiming the fixtures, you may use the bracket adjustment knob. Loosen the knob, adjust to the desired angle, and then tighten the knob by turning clockwise. Do not use tools for this step, as it may cause damage.
There is a secondary portion of the bracket, which may be used primarily for floor standing positions.
Safety cables must always be used.
(used primarily for
on the bracket
the gel frame release pointing up, (as shown in this
LED PAR 38-Tri B&C User Manual 8 Rev. 2
Page 9

Fixture Linking

BUTTON
FUNCTION
You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA­485 standard, no more than 32 fixtures should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended serial data link distance: 500 m (1640 ft) Maximum recommended number of fixtures on a serial data link: 32
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.

4. OPERATING INSTRUCTIONS

Configuring the Starting Address

Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose the starting addresses for each fixture so that the channels used do not overlap. In addition, you should note the starting address selected for future reference.
The LED PAR 38 Tri-B/C DMX, we recommend reading the “DMX Primer” section in the “Appendix”.
fixture uses seven or three DMX channels. If this is your first time using

Control Panel Functions

Access control panel functions using the four buttons located directly underneath the LED display on the included wired remote.
Used to scroll through the
<MENU>
<DOWN>
<UP>
<ENTER>
LED PAR 38-Tri B&C User Manual 9 Rev. 2
current operating mode, as well as back out of the current menu option
Used to select decreasing advancement in the value
Used to select increasing advancement in the value
Used to select a value and store it to memory
Page 10
P1
P2
P3
P4
P5
7 Color sound active
Use the Audio Adjustment of the fixture
P6
3-CH
d001~d512
-
-
Select 3-channel DMX mode (RGB control)
7-CH
d001~d512
Select 7-channel DMX mode: RGB, macros, run speed, strobe, automatic/sound, dimmer
C1
Red
C2
Green
C3
C4
C5
C6
Yellow
C7
S--
S001~S100
S050
This is the speed range for the 4 switching and fading built-in programs
r---
g---
B---
Blue
MENU DOWN UP ENTER
The Control Panel shows the current state of the unit. It is used to select the operating mode, as well as the sub-features. For a detailed layout of the control panel functions, please see the “menu map” section on the following page.
Menu Map
MAIN FUNCTION SUB-FUNCTION SELECTION SUB-SELECTION INSTRUCTION
7 Color Switching
P--
7 Color fading 3 Color Switching 3 Color Fading
-
Select between 2 switching and 2 fading built-in programs
C--
U--

DMX Operation

This is the operating mode which will allow for control with an external DMX controller. You must set the starting address for this mode. If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer” section in the “Appendix” of this manual.
1. Press <MENU> until
2. Press <ENTER>.
3. Using <UP> and <DOWN>, select the desired DMX address (

Master/Slave

This is the operating mode which will allow 1 fixture to act as the “master” and control all of the other “slave” fixtures. You must set both the master and the slave(s) fixtures to the correct mode for this operation.
Master Settings:
1. Connect the fixtures with DMX cables, as shown in the “Fixture Linking” section.
2. Use any one of the standalone modes for the master unit. This includes:
Slave Settings:
1. Press <MENU> until
3 Color sound active
- -
Blue Cyan Magenta
White (default range is Red
Green
Knob located on the back
)
000~100
3-CH or 7-CH appears on the LED screen.
3-CH or 7-CH appears on the LED screen.
-
-
Select between 2 sound active programs
Select between 7 static colors. The display will read these represent are indicated to the left.
Combine red, green, and blue to create a custom, static, color
C1~C7. The colors that each of
d001~d512).
P--, C--, and U--
LED PAR 38-Tri B&C User Manual 10 Rev. 2
Page 11
2. Press <ENTER>.
3. Using <UP> and <DOWN>, set the DMX address to
It is not necessary to set the master fixture as the first fixture in the daisy chain. It may be any fixture in the daisy chain. For example: fixture 2, 5, 10 or 12, etc.
Only 1 fixture may be set to master.
Do not connect a DMX controller to the daisy chain for this operating mode.

Standalone Operation

Automatic
This fixture has preprogrammed chases. These are accessed via the control panel, and the speed may be adjusted for the chases. Please see the instructions below for further explanation.
1. Press <MENU> until
2. Press <ENTER>.
3. Using <UP> and <DOWN>, select the desired program (
4. Press <ENTER> to confirm settings.
Sound-Active
This fixture has preprogrammed sound triggered chases. These are accessed via the control panel, and the speed may be adjusted using the audio adjustment knob. Please see the instructions below for further explanation.
1. Press <MENU> until
2. Press <ENTER>.
3. Using <UP> and <DOWN>, select the desired program (
4. Press <ENTER> to confirm settings.
Preset Colors
This fixture has preprogrammed static color presets. These are accessed via the control panel. Please see the instructions below for further explanation.
1. Press <MENU> until
2. Press <ENTER>.
3. Using <UP> and <DOWN>, select the desired color preset (
4. Press <ENTER> to confirm settings.
Custom Static Color Mixing
This fixture has the ability to accept custom static color settings. These are accessed via the control panel. Please see the instructions below for further explanation.
1. Press <MENU> until
2. Press <ENTER>.
3. Using <UP> and <DOWN>, select the desired color value ( color will remain off.
4. Press <ENTER> to continue to the next color (
5. Using <UP> and <DOWN>, select the desired color value ( color will remain off.
6. Continue until the desired mix is obtained. The order of colors is red, green, and then blue.
7. Press <ENTER> to save the final color setting. This will move the selection to the following color. However, this is necessary to save the modification.
d001.
P-- appears on the LED screen.
P1~P4).
P-- appears on the LED screen.
P5~P6).
C-- appears on the LED screen.
C1~C7).
U-- appears on the LED screen.
000~100). By selecting 000, the
r, G, b).
000~100). By selecting 000, the
LED PAR 38-Tri B&C User Manual 11 Rev. 2
Page 12
Fixture Linking
Additional signal
DMX controller
In order to use this fixture in a DMX or master/slave operation, you must daisy chain, using DMX cables to link from one fixture to another. In a master/slave operation, the DMX controller is not connected.
link out
(only in DMX
operation)
LED PAR 38-Tri B&C User Manual 12 Rev. 2
Page 13
DMX Channel Values
CHANNEL
VALUE
FUNCTION
000 255
Red
Dimmer: 0%~100%
000  255
Green
Dimmer: 0%~100%
000 255
Blue
Dimmer: 0%~100%
016 255
Color Macros (override CH.1~3)
Color Macros
000 255
Speed (CH.6 @ values 032~223)
Slow~Fast
016 255
Strobe (Red, Green, Blue, & Color Macro channels only)
Slow~Fast (6 Hz ~ 18 Hz)
224 255
Mode
Sound triggering mode
032~223, CH.5
000  255
Dimmer Intensity (RGB/Macro modes): 0%~100%
CHANNEL
VALUE
FUNCTION
000 255
Red
Dimmer: 0%~100%
000 255
Green
Dimmer: 0%~100%
000 255
Blue
Dimmer: 0%~100%
7-CH Mode
1
2
3
4
000 015
5
000 015
No Function
No Function
6
7
000 031 032 063 064 095 096 127 128 159 160 191 192 223
RGB mode Pulse effect 0%~100% (using RGB faders) Pulse effect 100%~0% (using RGB faders) Pulse effect 100%~0%~100% (using RGB faders) Auto fade transition Auto snap transition (3 colors) Auto snap transition (7 colors)
When CH.6 is set between controls the speed.
3-CH Mode
1
2
3
LED PAR 38-Tri B&C User Manual 13 Rev. 2
Page 14

5. APPENDIX

General Maintenance
To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.
Unplug fixture from power.
Use a vacuum or air compressor and a soft brush to remove dust collected on external
vents.
Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue.
Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens.
Gently polish optical surfaces until they are free of haze and lint.
The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. Clean the external optics at least every 20 days. Clean the fixture at least every 30/60 days.
Always dry the parts carefully after cleaning them.
Never spin a fan using compressed air.
Setting the Starting Address
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap, and note the start address selected for future reference. If you are unfamiliar with DMX, download the DMX Primer from
www.chauvetlighting.com.
LED PAR 38-Tri B&C User Manual 14 Rev. 2
Page 15

General Troubleshooting

SYMPTOM POSSIBLE CAUSE(S) POSSIBLE ACTION(S)
Breaker/Fuse
keeps blowing
Device does not
power up
Fixture is not
responding to
DMX
Loss of signal
Excessive circuit load Check total load placed on the electrical circuit. Short circuit along the power wires Check for a short in the electrical wiring (internal and/or
No power Check for power on power outlet Loose power cord Check power cord Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the
controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable/Low level signal Install amplifier right after fixture with strong signal Too many fixtures Install an optically coupled DMX splitter after unit #32 Interference from AC wires Keep DMX cables separated from power cables or black
If you still have a problem after trying provided solutions, contact CHAUVET® Technical Support.
external)
Check polarity switch settings on the controller
lights
Return Procedure
Returned merchandise must be sent prepaid and in the original packing; call tags will not be issued. Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). Products returned without the RMA # will be refused.
Call CHAUVET® and request an RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to pack fixture properly; any shipping damage resulting from inadequate packaging is the customer’s responsibility. FedEx packing or double-boxing are recommended.
CHAUVET® reserves the right to use its own discretion to repair or replace product(s).
If you are given an RMA #, please include the following information on a piece of paper inside the box:
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore, the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.
1) Your name
2) Your address
3) Your phone number
4) The RMA #
5) A brief description of the symptoms
LED PAR 38-Tri B&C User Manual 15 Rev. 2
Page 16

Technical Specifications

WEIGHT & DIMENSIONS
Length ............................................................................................................................................................. 9.3 in (235 mm)
Width ............................................................................................................................................................... 8.8 in (223 mm)
Height ............................................................................................................................................................ 11.4 in (290 mm)
Weight ............................................................................................................................................................... 3.3 lbs (1.5 kg)
POWER
Autoswitching Power Supply ............................................................................................................. 100~240 VAC, 50/60 Hz
Power Consumption @ 120 VAC, 60 Hz ................................................................................ 26 W (0.4 A) max, 0.2 A inrush
Power Consumption @ 230 VAC, 50 Hz ................................................................................ 24 W (0.2 A) max, 0.2 A inrush
Power output ........................................................................................................................................................ 16 units max
Fuse ...................................................................................................................................................................... F 1 A, 250 V
LIGHT SOURCE
LED ............................................................................................................................................................. 7 3 W, 350 mA X3
PHOTOOPTIC
Luminance @ 1 m ...................................................................................................................................................... 1,996 lux
Beam Angle ........................................................................................................................................................................ 22°
Field Angle .......................................................................................................................................................................... 42°
THERMAL
Maximum ambient temperature ......................................................................................................................... 104° F (40° C)
ORDERING INFORMATION
LED PAR 38 Tri-B (Black).............................................................................................................................. LEDPAR38TRIB
LED PAR 38 Tri-C (Chrome) ......................................................................................................................... LEDPAR38TRIC
WARRANTY INFORMATION
Warranty .............................................................................................................................................. 2-year limited warranty

Contact Us

World Wide
General Information CHAUVET® Lighting
Technical Support CHAUVET® Lighting
World Wide Web www.chauvetlighting.com
LED PAR 38-Tri B&C User Manual 16 Rev. 2
5200 NW 108th Avenue Sunrise, FL 33351 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
5200 NW 108th Avenue Sunrise, FL 33351 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
Loading...