Chauvet DL-LEDW, LED Durastrip DL-LEDW User Manual

Page 1
LED Durastrip™
DL-LEDW
USER MANUAL
CHAUVET, 3000 N 29
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
th
Ct, Hollywood, FL 33020 U.S.A
2006-08-28
Page 2
Table of Content
1. BEFORE YOU BEGIN.......................................................................................................................................................
UNPACKING INSTRUCTIONS..............................................................................................................................................................................................H3
CONTACT US...................................................................................................................................................................................................................H3
IMPORTANT SAFETY INFORMATION...................................................................................................................................................................................H4
2. INTRODUCTION ...............................................................................................................................................................H5
FEATURES.......................................................................................................................................................................................................................H5
FOREWORD.....................................................................................................................................................................................................................H5
OPTIONAL ACCESSORY PACK ..........................................................................................................................................................................................H5
COMPONENT OVERVIEW..................................................................................................................................................................................................H6
3. SETUP...............................................................................................................................................................................H7
AC POWER .....................................................................................................................................................................................................................H7
4. INSTALLATION.................................................................................................................................................................H8
Pattern Design .........................................................................................................................................................................................................H8
Cutting Marks (Cutting Unit) ....................................................................................................................................................................................H8
Maximum Lengths and Power Consumption...........................................................................................................................................................H8
Installation................................................................................................................................................................................................................H9
Options...................................................................................................................................................................................................................H10
5. APPENDIX.......................................................................................................................................................................H11
RETURNS PROCEDURE..................................................................................................................................................................................................H11
CLAIMS .........................................................................................................................................................................................................................H11
TECHNICAL SPECIFICATIONS..........................................................................................................................................................................................H11
TECHNICAL SUPPORT....................................................................................................................................................................................................H11
H3
©CHAUVET, 2006, All Rights Reserved Information and specifications in this User Manual are subject to change without
notice. CHAUVET assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.
Durastrip™ User Manual 2 2006-08-28
/17:47
Page 3
1. Before You Begin
Unpacking Instructions
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Note: If you should require sending any items back to CHAUVET, call CHAUVET for
a (RMA) Return Merchandise Authorization number. The factory will not allow any shipments without an RMA.
Your shipment includes the following:
30ft roll of Durastrip™
2pcs – Power Cord with 1.6A Adapter
2pcs – Splice Connector
2pcs – End Caps
10pcs – Mounting Clips
Warranty Card
Users Manual
Contact Us
World Wide
General Information Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
Technical Support Chauvet Lighting
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
World Wide Web www.chauvetlighting.com
th
Court
th
Court
Durastrip™ User Manual 3 2006-08-28
/17:47
Page 4
Before You Begin
Important Safety Information
This product is designed for professional use. It is not intended for use in a household environment. This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and injury from falls. Read this manual before installing or powering the fixture, follow the safety precautions listed below and observe all warnings in this manual and on the fixture. If you have any questions about how to operate the fixture safely, please contact CHAUVET.
Protection against Electric Shock
Always disconnect from AC power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source.
All Class I fixtures must be connected to circuits with a suitable Earth Ground.
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the cord.
Protection against Fire & Burns
This product is designed to be used with very specific lamp(s). Use of any other type of lamp not stated in this manual may create a fire hazard due to possible risk of lamp explosion. Using the wrong type of lamp in this product VOIDS the warranty.
Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture.
Maximum ambient temperature is Ta: 40°. Do not operate fixture at temperatures higher than this.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET.
Durastrip™ User Manual 4 2006-08-28/17:47
Page 5
2. Introduction
LED Durastrip™ is a professional linear lighting device using LED technology. It looks identical to traditional rope lighting, but it is much more durable, lasts longer and is 100% waterproof. Only a few tools are required for field design and installation. Durastrip™ is ideal for permanent, fixed installations requiring minimum maintenance but can also be useful when adding last minute, creative, custom design details.
Professionals in the entertainment industry will find practical, functional and creative use of the Durastrip™ product in the design of tradeshow booths, special events, merchandising, retail displays and themed environments. Commercial applications include building outlines, coves, under cabinets, aisle ways, RVs, boats and many more locations.
Features
Clear, rectangular, flexible linear LED rope
Bright, solid white LEDs
Designed for clean edge installations
Fits extrusions, tile, wood work, mirrors, flooring or walls (routed track)
Indoor and outdoor use
Lower power consumption
Shockproof and flexible
Low maintenance, low heat, long life
Light weight and easily transportable
Foreword
Please review the components overview section before commencing with installation. It will be important to have ready the tools necessary to complete the job successfully. One such item to draw special attention to is the PVC glue. CHAUVET does not provide PVC glue with the accessories enclosed. This item is continuously illustrated in all pictures and is an integral component for maintaining water-tight connections. PVC glue and cement are general terms. Be sure to use adhesive that will bond to PVC.
Following is a list of the accessories enclosed with this product;
2 Pieces:
............................................................................................................Power cord with AC/DC converter
....................................................................................................Splice Connector & Heath Shrink Tube
....................................................................................................................................................End Cap
10 Pieces:
............................................................................................................................................Mounting Clip
Optional Accessory Pack
Item No. Inclusions
1 pc - Power Cord with 1.6A Converter
DL-LEDACC
2 pcs - T Connector
2 pcs - Splice Connector & Heat Shrink Tube
2 pcs - End Cap
Durastrip™ User Manual 5 2006-08-28
/17:47
Page 6
Introduction
Component Overview
Items Included with your purchase:
Power Cord with
1.6A Adapter
Splice Connector & Heat Shrink Tube
Items NOT included with your purchase but recommended during installation:
Cutter
End Caps
Mounting Clips
Channel Track
Scissor
Diagonal Cutter
Durastrip™ User Manual 6 2006-08-28/17:47
PVC Glue This item is important in maintaining water tight connections. Please visit your local hardware store to purchase. Read the “Foreword” section of this manual.
Double Sided Tape
T-Connector available in DL-LEDACC accessory package.
Page 7
3. Setup
AC Power
Warning! Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
Power Cable Configuration
CABLE Pin International Screw Color
BROWN Live L Yellow or Brass
BLUE Neutral N Silver
YELLOW/GREEN Earth
Class II Device will not require a Ground
EG (Ground) W
Green
Durastrip™ User Manual 7 2006-08-28
/17:47
Page 8
4. Installation
The LED Durastrip™ is a versatile and user friendly linear lighting device; it can be cut and bent and formed in the field and easily installed on flat surfaces of varied materials, such as wood, plastic, steel, or on walls to form all kinds of pattern according to your design.
Pattern Design
Please follow the following pattern related pre-installation guidelines;
1. Mark centerlines or draw outlines of your pattern on the installation surface.
2. Place or line up Durastrip™.
3. Secure mounting clips on the centerlines at appropriate intervals with screws. Secure clips
immediately after each curve to secure.
4. Connect pieces together.
Cutting Marks (Cutting Unit)
Item No. Description Cutting Unit DL-LEDW LED Durastrip™ Every 3 Feet
It is important to always cut on the “Cutting Marks”
Maximum Lengths and Power Consumption
Do not exceed the 240 feet maximum length and only cut on the provided marks every 3 feet.
Number of LEDs Per Unit
LED Spacing
Watts Consumed Per Feet
Maximum Length with 1.6A AC/DC
Dimension
5 x 8 mm
.197 x .315 in
Cutting Unit
3 Feet 36 1 in 0.8W/Ft 240 Ft
Durastrip™ User Manual 8 2006-08-28
/17:47
Page 9
Operating Instructions
Installation
Cut only on the indicated mark. A mark should exist every 3 feet.
Before making a splice connection, bend the tip of a newly cut strip in opposing directions several times. Cut any excess copper wires that protrude from the end with a diagonal cutter.
Use the specially designed splice connector along with the splice tube to connect two sections of Durastrip™.
Do not exceed 240 feet length when using the 1.6 Amp AC/DC molded power adapters.
End the strip with end cap to maintain a water tight seal.
Durastrip™ User Manual 9 2006-08-28/17:47
Page 10
Operating Instructions
Options
Use mounting clips for flat surface mounting.
Frame objects, letters any many designs using metal wires and tie wraps.
Use double-sided tape to adhere to indoor dry surfaces.
Durastrip™ User Manual 10 2006-08-28/17:47
Page 11
5. Appendix
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.
Technical Specifications
WEIGHT & DIMENSIONS
Rectangular linear device.............................................................................5 x 8 mm (0.197 x 0.315 in)
Package Weight ........................................................................................................ 1.47Kgs ( 3.25 lbs)
POWER
AC/DC 1.6A Power Converter & plug....................................................................................115V 60 Hz
European version ..................................................................................................................240V 50 Hz
Watts Consumption............................................................................................................ 0.8W per foot
Length of Roll ................................................................................................................ 30 feet (9.14m)
Number of LEDs ................................................................................................... 12 per foot (30.5cm)
Cutting Units............................................................................................................... 3 feet (91.44 cm)
ORDERING INFORMATION
LED Durastrip™ .......................................................................................................................DL-LEDW
LED Durastrip™ Accessory Pack (see pg. 5) ..................................................................... DL-LEDACC
Technical Support
Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com
Htech@chauvetlighting.com
Durastrip™ User Manual 11 2006-08-28
/17:47
Loading...