Please read these instructions carefully before use
3000 North 29th Ct., Hollywood, Florida, USA, FL 33020
Tel: +1-954-929-1115 Fax: +1-954-929-5560
World-wide Headquarters:
www.ChauvetLighting.com
Page 2
Mounting Bracket
On Side
Scanning Mirror
Aperture
DMX In
DMX Out
DIP Switches
On rear
DMX LED Indicator
Fuse Holder
Power Connector
Introduction
Congratulations on the purchase of your new CHAUVET lighting effect. We are confident you will enjoy many trouble free
hours with this unit. To assist with the care and use of the product we have prepared this short guide.
Setting Up
This lighting effect has been designed to function on a mains power supply of 120V~60Hz and has been fitted with a suitable
power plug.
When connected to the mains power supply the unit should illuminate and shoot a single 4.9mW green laser beam. The unit
will also begin to run through its pre-programmed sound activated patterns.
Do not switch the fixture on and off in short intervals as this will cause damage to the laser.
Do not shake the fixture.
Due to the high operating temperature of the laser it is advisable that the effect be used in well
ventilated areas taking care not to obstruct the air vents. After use allow time to ‘cool’ for safety and to ensure longevity before
moving or touching.
The Lazer Scan (LGG3100X) is a DMX fixture that can be operated with Chauvet's DMX-6 controller, DMX-40, DMX controller,
ShowXpress or any other universal DMX controller. The LGG3100X will also work in stand alone mode, either automatic or
sound activated. To operate in DMX mode, you must link the units together using a premium quality 3-pin DMX cable in the
following configuration. 'Out' from the first unit to 'In' on the second, 'Out' from the second to 'In' on the third and so on.
The Lazer Scan (LGG3100X) is a three channel DMX fixture. In order to activate the DMX mode, DIP switch # 10 must be in
the OFF position. Please consult the controller manual to determine the proper address for theLazer Scan (LGG3100X).
Page 3
Example: To set the address at 12
12345678910
Off
On
Value1248163264128256
DMX Signal Levels
1. Set SW 10 to OFF.
2. Count the value of the switches in the on position.
and SW 4 equals 8.
3. Set SW 3 and SW 4 to the ON position. (4 + 8 = 12)
When both Channel 1 and Channel 2 and 3 are set at 255, the LGG3100X will function in stand alone beat activation mode.
Page 4
Function Selection
The LGG3100X will operate in stand alone as well as DMX mode. In stand alone mode, the user has the option of beat
activation or automatic. To access these functions, the DIP switches are utilized as per the chart below.
Installation / Mounting
Although this unit can be used in an upright position, it is recommended that, for safety purposes, your lighting effect be
properly mounted using a suitable hanging clamp and safety cable. CHAUVET offers a range of items, which are ideal for safe
mounting.
Use in a well-ventilated area without obstruction to air vents.
Unit should be mounted in such a manner that the emitted beam will not strike people.
Replacing Fuses
If the unit does not function at all when connected to the main power supply i.e. the mechanism does not spin. Then it is highly
likely that the fuse has blown.
Disconnect from main power supply before attempting to replace either lamps or fuse.
In order to replace the fuse, disconnect from the main power supply first, and then unscrew the fuseholder cover to reveal the
fuse. The unit has a label attached which indicates the correct fuse rating and you will also find this listed as part of the
specifications for the unit later in this guide. It is most important that replacement fuses are of the correct rating. Failure to use
the correct fuse could damage the lighting effect beyond economic repair.
The fuse should simply be placed inside the holder and the screw cap replaced, when this is done connect to the main power
supply to check. If the unit is still not working then please contact your dealer or
CHAUVET for servicing.
Page 5
Cleaning
The most important part of your lighting effect to keep clean are the mirrors as they allow the light output to transmit. They
should be cleaned with a soft damp cloth. There is also a single mirror located under the center cap that should also be
cleaned. The body of the unit may also be cleaned in the same way. We recommend internal cleaning be carried out by a fully
qualified technician.
Maintenance & Servicing
Work on internal parts should be carried out by a qualified technician. Removal of covers other than the front to replace lamp or
effect dish, or the fuseholder is considered a breach of warranty and will not be covered under any such agreement unless
authorized first by the company.
Troubleshooting
• If the unit is not functional – check main power supply is ‘on’ and check fuses.
• If the unit is not moving to the music check the sound-activation adjustment (when applicable)
• If after trying this solution you still have a problem contact your dealer or CHAUVET.
Do not obstruct the air vents.
Do not touch unit while hot.
No user serviceable parts inside, please refer to CHAUVET for service.
Unit should be mounted in such a manner that the emitted beam will no strike people.
Power Connections
The unit is supplied with a power plug appropriate to its voltage and destination. Should any other
connections be required they must be carried out with the following configuration.
Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable
In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground connection.
In the UK, it is required that all mains plugs are fitted with 5A fuses.
Technical Specifications
Power120V, 60Hz AC240V, 50Hz Ac
Fuse20mm Glass 1A Fast Blow20mm Glass 1A Fast Blow
1 x 4.9mW Green Laser1 x 4.9mW Green Laser
DiodePart No. 4.9mW GreenPart No. 4.9mW Green
Dimensions457 x 101.6 x 101.6mm / 18 x 4 x 4in457 x 101.6 x 101.6mm / 18 x 4 x 4in
Weight5 kg / 12.75 lbs5 kg / 12.75 lbs
Page 6
Chauvet Lighting
CAUTION - CLASS 3R
LASER RADIATION WHEN
OPEN AVOID DIRECT EYE
E X P O S U R E
CAUTION - CLASS 3R
LASER RADIATION WHEN
OPEN AVOID DIRECT EYE
E X P O S U R E
Push button ON/OFF switch
3000 North 29th Ct.
Hollywood, Fl 33020 USA
Manufactured: January,2002
Complies with FDA performance
standards for laser products
with the exception of deviation
pursuant to Laser Notice No. 50,
dated July 26, 2001
LASER RADIATION
AVOID DIRECT EYE EXPOSERE
CLASS 3R LASER PRODUCT
5.0 mW max CW Diode 532 nm
IEC/EN 60825-1, ed 1.2
CAUTION - CLASS 3R
LASER RADIATION WHEN
OPEN AVOID DIRECT EYE
E X P O S U R E
Caution- use of controls or adjustments or
performance of procedures
other than as specified herein may result in
hazardous radiation exposure.
(Prolonged exposure to single static laser beam can cause retinal damage)
Warning: Do not look directly into the Laser!