Technical Specifications
Power
AC 120V~60Hz
AC 230V~50Hz
Fuse
20mm Glass 5A Fast Blow
Lamps
1 x 24V 250W
Part No. ELC3 24V 250W (300 Hrs)
Dimension
DMX-100
263mm x 314mm x 202mm / 10.35in x 12.36in x 7.95in
DMX-100S/DMX-100B
470 x 314 x 245 mm / 18.5in x 12.36in x 9.65in
Weight
7.7 kg / 16.94 lbs ( DMX-100 )
10 kg / 22 lbs ( DMX-100S/DMX-100B )
User Information (Please complete for your records)
Data Purchased : / / Serial No. :
Dealer Stamp : Model : DMX-100 FASCINATION
DMX-100S IMAGINATION
DMX-100B SENSATION
FASCINATION
DMX-100
IMAGINATION
DMX-100S
SENSATION
DMX-100B
User Guide
Please read these instructions carefully before use
World-wide Headquarters:
3000 North 29th Ct., Hollywood, FL
USA 33020
Tel: +1-954-929-1115 Fax: +1-954-929-5560
www.ChauvetLighting.com
Page 2
E. FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be
carried out periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates: damp, smoky or particularly dirty
surroundings can cause greater accumulation of dirt on the unit’s optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 20 days. Clean the internal
optics at least every 30/60 days.
EC Declaration of Conformity
We declare that our products ( lighting equipments ) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility ( EMC ) Directive 89/336/EEC.
EN55014-1: 1993, EN61000-3-2: 1995, EN61000-3-3:1995 EN55014-2: 1997 CATEGORY II EN61000-4-2: 1995, EN61000-4-3: 1995, EN61000-4-4:1995 EN61000-4-5: 1995, EN61000-4-6: 1995, EN61000-4-11: 1994
&
Harmonized Standard
EN60598-1: 1993 Safety of household and similar electrical appliances Part 1 : General requirements
Following the provisions of the Low Voltage Directive 73/23/EEC and 93/68/EEC.
EC Declaration of Conformity
We declare that our products ( Remote Controller ) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility ( EMC ) Directive 89/336/EEC.
EN55015: 1993 EN50082-1: 1997 EN61000-3-2: 1995 EN61000-3-3: 1995
Page 3
( 3 ) By easy controller CA-6
The easy remote control is used only in master/slave mode. By connecting
to the 1/4” microphone jack of the first unit (its DMX input plug is not used), you
will find that the remote control on the first unit will control all the other units for
stand by, Strobe/Next and Fast/Slow function.
1. STAND BY : Stand by and blackout all the unit.
2. STROBE/NEXT : Press the button and keep pressed
up, when the unit is in fast mode, it will strobe by sound.
Strobe function is only effective while the button is held
down. It has three strobe modes. If the unit was in slow
mode, you can select the next color and gobo. It will
change ten colors and then change one gobo.
3. FAST/SLOW : When the led light off, it is in FAST
Mode. The unit movement by sound activated. If the led
light on, it is in SLOW mode, the unit movement slowly.
TABLE OF CONTENTS
A. GENERAL INSTRUCTIONS
B. MAIN FEATURES
C. LAMP
D. HOW TO CONTROL THE UNIT
-----(1) By universal DMX controller
-----(2) Preprogrammed function
-----(3) By easy controller CA-6
E. FIXTURE CLEANING
Page 4
( 2 ) Preprogram functions
DMX-100 can be linked together as master/slave in 2 or 4 channels and run
by built in preprogrammed chase sequences by sound activation. When sound
stops, all the lights will shut down (blackout) immediately and then the bulb will
turn off 15 seconds later. Please refer to the unit dipswitch-setting table for how
to set the dipswitches to achieve master/slave linking.
In master/slave mode, the dipswitch 10 must be on of the master unit.
DMXS/DMXB can be linked together as master/slave in daisy chain in
linkage as many units as required and run by built in preprogrammed chase
sequences automatically or by sound activation. Not need to set the
dipswitches in master/slave mode.
When linking the PANTHER and the JAGUAR in stand-alone mode, the
JAGUAR must be used as the master head.
2-light show
Dipswitch 10 “off” means the unit works normally and “on” means inversion. In
order to creating a great light show, you can set dip switch 10 “on” on any unit
that is linking to the master unit to get contrast movement to each other, even if
you have two units only. Dipswitch 10 on the first unit is no use in the DMX linking,
as it is the master unit that operates the light show.
2-Channels dip switches setting
Master
Slaver 1
4-Channels dip switches setting
Master
Slaver 1
Slaver 2
Slaver 3
Page 5
Gobo 9 /Pink
Gobo 7 / Magenta
Gobo 5 / Orange
Gobo 3 / Yellow
Blackout
Gobo 1 / Multicolor
0
DMX512 CONFIGURATION
Channel 1
Gobo 11 / Orange
Gobo 13 / White
Gobo 14 / Green + Pink
Gobo 12 / Blue
Gobo 10 / Magenta
Gobo 2 / Blue
Gobo 4 / Green
Gobo 6 / Red
Gobo 8 / Light Blue
Open
Channel 2 Channel 3 Channel 5
TiltPanGobo / ColorShutter
8
16
24
32
40
48
56
64
72
80
88
96
104
112
120
128
255
0
255
10
121
Flat FlatBarrel Barrel
Stopped
Stopped
Stopped
Channel 4
Reflector mirror
0
255
Stopped
Slowest speed
Fastest speed
15
Slow strobe
Fast strobe
Stopped
Stopped
246
Stopped
135
14
13
1211
109
2
open
876
5
4
3
1
Start the address
How to address your DMX512 system:
1. Select the channels of DMX controller
2. Dipswitches
Dip#1#2#3#4#5#6#7#8
#9
Value1248163264128
256
Examples:
Channel 01dip / on : #1=1
Channel 06dip / on : #2, #32+4=6
Channel 11dip / on : #1, #2,#41+2+8=11
Channel 16dip / on : #5( =16)
A. GENERAL INSTRUCTIONS
Please read the enclosed instructions carefully as they include important
points about safety for the installation, usage and maintenance of the unit.
Please keep this booklet with the unit for future consultation. If you sell the unit
to another user, be sure that the new user also receives this instruction booklet
thus giving them the necessary information about the use and general
warnings regarding the unit.
Before the initial start-up, please unpack and carefully check all components in
case any damage may have occurred during shipping.
Locate a suitable spot for your device where there is good ventilation. Also,
make sure that no ventilating fans or slots are blocked.
Protect our environment! Please dispose of the packing boxes properly.
The electrical work that is necessary for installation must done by qualified
personnel.
Always remember to unplug the unit from the main power before any service is
done. Do not open the unit. There are no serviceable parts inside.
It is very important to ground the yellow/green conductor to earth in order to
meet regulations for safety.
Check the surrounding area and make sure there are no flammable liquids, water
or metal objects that could enter the fixture. If a foreign object enters the unit,
immediately disconnect the main power. Also, place the fixture in a well-
ventilated room at about 15 cm from the walls.
Do not touch any wires during operation, as high voltage is hazardous.
In the event of serious operating problems, stop using the unit immediately.
Never try to repair the unit yourself. Repairs carried out by unqualified
personnel can lead to damage or malfunction. Please contact the nearest
authorized Technical Assistance Center. Always use genuine spare parts.
Page 6
B. MAIN FEATURES
VoltageAC 120V~60Hz or 230V-250V~50 Hz
Bulb ELC3 24V 250W
The unit is a DMX512 scanner. It features full DMX512 control, 14 gobos/colors
plus open, accurate focusable optics system and stepper motor with blackout
feature. Fan cooled.
It can be operated by DMX512 control or can be used as an individual unit
without a control.
It can be linked together in master/slave combination units, as many as
required in 4 channels and run by built-in preprogrammed chase sequences
automatically or by sound activation through an internal microphone to create
an intelligent effect.
Please use a 3 pin XLR cable/plug when connecting them together.
It features different preprogrammed chase patterns.
DimensionsDMX-100
263 x 314 x 202 mm / 10.35in x 12.36in x 7.95in
DMX-100S / DMX-100B
470 x 314 x 245 mm / 18.5in x 12.36in x 9.65in
Weight: 7.7 kg / 16.94 lbs ( DMX-100 )
10 kg / 22 lbs ( DMX-100S / DMX-100B )
C. LAMP
ELC3 24V 250W (300 Hrs)
Always switch off the mains supply and never handle the lamp or luminaire
when it is hot.
Do not touch the bulb with bare hands. If this does happen, clean the lamp
with denatured alcohol and wipe with a lint free cloth before installing.
D. HOW TO CONTROL THE UNIT
( 1 ) By universal DMX controller
The DMX512 is widely used in intelligent lighting control, with a maximum of 512
channels.
DMX +
COMMON
DMX -
advisable to connect a DMX terminal.
pin3 (DMX+) of the last fixture.
transmission problems and interference. It is always
(Resistance 120 ohm 1/4W) between pin2 (DMX-) and
Termination reduces signal errors and to avoid signal
INPUT
DMX512
1
2
3
21
OUTPUT
1
2
3
120 ohm 1/4W
1
2
3
43
2
3
1
ü A DMX512 system requires a controller, lighting equipment and cable. These
are connected together in a “daisy chain” with the terminator at the end. The
cable cannot be branched or split to a “Y” cable.
ü The terminator requires a 90-120 Ohm 1/4 Watt resistor soldered between two
signal cables.
ü The DMX512 uses a very high-speed signal. Inadequate or damaged cables,
bad solder joints or corroded connectors can easily distort the signal and shut
down the system. A reliable DMX512 system starts with good quality cables.
ü Each lighting unit needs to have an address set to receive the data sent by
the controller. The address number is between 0-511. The end of the
DMX512 system should be terminated reducing signal errors.
ü 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)