Chauvet Hurricane 700 User Manual

Page 1
User Manual
Page 2
TABLE OF CONTENTS
What Is Included ............................................................................................................................... 3
Unpacking Instructions ..................................................................................................................... 3
Claims ....................................................................................................................................................... 3
Text Conventions ............................................................................................................................. 3
Symbols ............................................................................................................................................ 3
Disclaimer ......................................................................................................................................... 3
Product at a Glance .......................................................................................................................... 4
Safety Notes ..................................................................................................................................... 4
2. Introduction ................................................................................................................... 5
Overview ........................................................................................................................................... 5
AC Power ......................................................................................................................................... 6
Fuse Replacement .................................................................................................................................... 6
Mounting ........................................................................................................................................... 7
Orientation ................................................................................................................................................. 7
Rigging ...................................................................................................................................................... 7
Using the Wired Remote .................................................................................................................. 8
Fogger Maintenance ........................................................................................................................ 8
Storage ............................................................................................................................................. 8
6. Technical Specifications ............................................................................................... 9
Returns ........................................................................................................................................... 10
Contact Us ...................................................................................................................................... 10
Page 2 of 10 Hurricane™ 700 User Manual Rev. 8
Page 3
What Is
Unpacking
Instructions
and check the container to make sure all the
included accessories) appear damaged from
, damage not related to shipping,
Text
1 to 512
A range of values
50/60
A set of values of which only one can be chosen
Symbols
Critical installation, configuration, or operation information. Not damage to the product, or cause harm to the operator.
Disclaimer
are subject to change ity for any errors or
and reserves the right to revise or recreate this manual at any time.
1. BEFORE YOU BEGIN
Included
Claims
Conventions
Hurricane™ 700
Fog Fluid (1 pint)
Power Cord
Carefully unpack the product immediately parts are in the package and are in good condition.
If the box or the contents (the product and shipping, or show signs of mishandling, notify the carrier immediately, not CHAUVET®. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts or concealed damage, file a claim with CHAUVET® within 7 days of delivery.
Convention Meaning
Symbol Meaning
following these instructions may make the product not work, cause
Important installation or configuration information. The product may not function correctly if this information is not used.
Warranty Card
Quick Reference Guide
Permanently Wired Remote
Useful information.
The information and specifications contained in this User Manual without notice. CHAUVET® assumes no responsibility or liabil omissions, Download the latest version from www.chauvetlighting.com.
© Copyright 2013 CHAUVET®. All rights reserved.
Electronically published by CHAUVET® in the United States of America.
Author Date Editor Date
A. Leon 10/15/13 D. Couppe 10/15/13
Hurricane™ 700 User Manual Rev. 8 Page 3 of 10
Page 4
Product at a
x
x
x
P
x
P
x
x
x
Safety Notes
Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.
Drain the tank before transporting the product.
Glance
Use on Dimmer Outdoor Use Sound-Active DMX Master/Slave
These notes i nclude important information about the mounting, usage, and maintenance of this product; read before using the product.
Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect the product from the power source before cleaning or replacing
the fuse.
Make sure the power cord is not crimped or damaged.
Never disconnect the product from power by pulling or tugging on the cord.
If mounting the product overhead, always secure to a fastening device using a
safety cable.
Make sure there are no flammable materials close to the product when operating.
Do not touch the product’s housing when operating because it may be very hot.
Do not mount the product on a flammable surface (linoleum, carpet, wood, paper,
carton, plastic, etc.).
Do not touch the output nozzle on this product. It is very hot during operation and it may remain hot for several hours after turning the product off.
The fog exits the nozzle at a very high temperature. Keep a minimum distance of
6.5 ft (2 m) from the nozzle to the nearest object.
Do not drink the fog fluid. If you do, call your local emergency service (911 in the US) for help.
Auto Programs Fixed voltage (120 V or 230 V) Replaceable Fuse User-Serviceable
Depending on the amount of fog generated, all fog machines may set off smoke detectors.
Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product.
Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the product’s housing are blocked.
Never connect the product to a dimmer or rheostat.
Make sure to replace the fuse with another of the same type and rating.
Never carry the product from the power cord or any moving part. Always use the
hanging/mounting bracket.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.
In the event of a serious operating problem, stop using the product immediately.
Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction. Contact the nearest authorized technical assistance center.
This product is not intended for permanent installation.
Do not use for space heating purposes.
Use only CHAUVET® water-based fog fluid.
Keep this User Manual for future use. If you sell the product to another user, be sure to give this document to the next owner.
FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET® to clean your Hurricane™ 700. Make sure you use FCQ regularly to increase the life of your fogger.
Page 4 of 10 Hurricane™ 700 User Manual Rev. 8
Page 5
2. INTRODUCTION
Overview
Power In
Fuse Holder
Fog Fluid
Cover
Fog Fluid
Indicator
Reservoir
Permanently
Wired Remote
Nozzle
Level
Back Panel View
Hurricane™ 700 User Manual Rev. 8 Page 5 of 10
Page 6
AC Power
can work with an input
circuit breaker, power outlet, and
’s back panel, or
’s specifications chart. The listed current rating indicates the
(circuit breaker or fuse). Make
an appropriate electrical ground to avoid the risk of
a rheostat (variable resistor) or dimmer circuit, even
Fuse
Installed fuse (held by plastic clip)
Spare fuse holder
(inside safety cap)
Safety cap
3. SETUP
The Hurricane™ 700 has a fixed voltage power supply and it voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product’s power requirements ( wiring), use the current value listed on the label affixed to the product refer to the product product’s average current draw under normal conditions.
Always connect the product to a protected circuit sure the product has electrocution or fire.
Never connect the product to if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Replacement
Disconnect the product from power before replacing the fuse.
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the fuse holder out of the housing.
4. Remove the blown fuse from the holder.
5. Replace with a fuse of the exact same type and rating.
6. Insert the fuse holder back in place and reconnect power.
A spare fuse is not included; however, the safety cap has room for a spare.
Always replace a blown fuse with another of the same type and rating.
Page 6 of 10 Hurricane™ 700 User Manual Rev. 8
Page 7
Mounting
, read and follow the safety recommendations indicated in
ventilation is provided around
Mount the
appropriate
knobs allow for directional adjustment when aiming the
Mounting Clamp
Rubber Feet (x4)
for floor mounting
Bracket
Adjustmen Knob
Before mounting the product the Safety Notes.
Orientation
When mounting the Hurricane™ 700, make sure adequate the product.
Rigging
Before deciding on a location, always make sure there is easy access to the product for maintenance and fluid replenishment.
Make sure that the structure or surface onto which you are mounting the product can support the product’s weight (see the Technical Specifications
).
When mounting the product overhead, always use a safety cable. product securely to a rigging point, such as an elevated platform or a truss.
When rigging the product onto a truss, you should use a mounting clamp of appropriate weight capacity. The bracket has 8.89-mm holes, which are for this purpose.
The bracket adjustment product to the desired angle. Only loosen or tighten the bracket knobs manually. Using tools could damage the knobs.
Hanging/Mounting
Mounting Diagram
Bracket
Safety Cable
(x 2)
Hurricane™ 700 User Manual Rev. 8 Page 7 of 10
Page 8
Using the
Trigger the Hurricane™ 700 using the included wired remote. The LED indicator on the remote indicates when the fogger has reached the required operating temperature. Press
Fogger
to become contaminated. After every 40 hours of continuous
cleaning the system to prevent the accumulation of
FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET® to clean your fogger.
Storage
, run distilled water (not tap water) through the system as
described in the cleaning method above. This will help to avoid any particles condensing
run the machine on a monthly basis in order to
LED Indicator Light
Momentary Fog Button
4. OPERATION
Wired Remote
the button on the remote to momentarily output fog. The length of the wired remote is 13 ft (4m).
Fill the fog fluid reservoir with CHAUVET® water-bas ed fog fluid be fore operat ing the Hurricane™ 700.
Permanently Wired Remote
5. TECHNICAL INFORMATION
Do not allow the fogger
Maintenance
operation, CHAUVET® recommends particulate matter in the heating element.
The recommended cleaning procedure is as follows:
1. Empty all fog liquid from the machine.
2. Add cleaning solution to the tank.
3. Connect the product to power and allow it to warm up.
4. Run the unit in a well-venti late d area until the ta nk is almost empty . Do not allow the pump to run dry.
5. Cleaning is now complete. Refill with fog liquid. Run the machine briefly to clear any cleaning solution from the pump and heater.
Hurricne™ 700. Make sure you use FCQ regularly to increase the life of your
Before storing the product inside the pump or heater.
It is strongly recommended to test­achieve its best hazing condition.
Page 8 of 10 Hurricane™ 700 User Manual Rev. 8
Page 9
Dimensions and
Length
Width
Height
Weight
8.5 in (215 mm)
7.1 in (180 mm)
4.9 in (124 mm)
4 lb (1.8 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Voltage Selection
120 VAC, 60 Hz
or 230 VAC, 50 Hz
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
471 W
471 W
Operating current
3.9 A
2.0 A
Fuse
T 7 A, 250 V
T 7 A, 250 V
Power I/O
US/Worldwide
UK/Europe
Power input connector
IEC
IEC
Power Cord plug
Edison (US)
Local plug
Operation/Capacity/
Consumption
Heat-up Time
Tank Capacity
Fluid Consumption
2.5 min
0.2 gal (0.6 l)
7.5 ml/min
Misc.
Output
1500 cfm
Wired Remote
Length
13 ft (4 m)
Thermal
Maximum External Temp.
Cooling System
104 °F (40 °C)
Convection
Ordering
Product Name
Item Code
UPC Number
Hurricane™ 700 (120 V)
09070161
781462202941
Hurricane™ 700 (230 V)
09070323
781462206758
6. TECHNICAL SPECIFICATIONS
Weight
Model-specific
Fixed
Hurricane™ 700 User Manual Rev. 8 Page 9 of 10
Page 10
, United Kingdom, or Ireland, contact your distributor of
s to
Returns
Support office and request a Return
. Be prepared to
provide the model number, serial number, and a brief description of the cause for the
ndise prepaid, in its original box, and with its original packing
the following information on a piece of paper
properly. Any shipping damage resulting from inadequate
reserves the right to use its own discretion to repair or replace
Contact Us
Fax: +44 (0)1773 511110
Email: tech@chauvetlighting.com
www.chauvetlighting.com
www.chauvetlighting.co.uk
To return a product or reques t supp ort :
In the U.S., contact CHAUVET® World Headquarters (see below).
In the UK or Ireland, contact CHAUVET® Europe Ltd. (see below).
In any other country, DO NOT contact CHA UV E T®. Contact your distributor. See
www.chauvetlighting.com
for distributors outside the U.S., United Kingdom, or
Ireland.
If you live outside the U.S. record and follow their instructions on how to return CHAUVET® product them. Visit our website for contact details.
Call the corresponding CHAUVET® Technical Merchandise Authorization (RMA) number before shipping the product
return. You must send the mercha
and accessories. CHAUVET® will not issue call tags. Clearly label the package with the RMA number. CHAUVET® will refuse any product
returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Before sending the product, clearly write and place it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product packaging will be your responsibility. FedEx packing or double-boxing are recommended.
CHAUVET® returned product(s).
World Headquarters
CHAUVET® General Information
Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll free: (800) 762-1084
Technical Support
Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015
United Kingdom & Ireland
CHAUVET® Europe Ltd. General Information
Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115
Technical Support
Email: uktech@chauvetlighting.com
World Wide Web
Page 10 of 10 Hurricane™ 700 User Manual Rev. 8
World Wide Web
Loading...