Chauvet FS-4200 User Manual

Page 1
Foot Master™ 4200
FS-4200
USER MANUAL
CHAUVET, 3000 N 29
FAX (954) 929-5560
www.chauvetlighting.com
th
Ct, Hollywood, FL 33020 U.S.A
2007-02-13
/14:05
Page 2
Table of Contents Table of Contents
1. BEFORE YOU BEGIN....................................................................................................................................................... 3
UNPACKING INSTRUCTIONS..............................................................................................................................................................................................3
CONTACT US................................................................................................................................................................................................................... 3
SAFETY INSTRUCTIONS.................................................................................................................................................................................................... 4
2. INTRODUCTION ............................................................................................................................................................... 5
FEATURES....................................................................................................................................................................................................................... 5
PRODUCT OVERVIEW.......................................................................................................................................................................................................6
3. SETUP............................................................................................................................................................................... 7
AC POWER .....................................................................................................................................................................................................................7
MOUNTING ......................................................................................................................................................................................................................7
4. OPERATING INSTRUCTIONS.......................................................................................................................................... 8
USING THE FS-4200........................................................................................................................................................................................................8
CONNECTION DIAGRAM ...................................................................................................................................................................................................8
5. APPENDIX......................................................................................................................................................................... 9
RETURNS PROCEDURE....................................................................................................................................................................................................9
CLAIMS ...........................................................................................................................................................................................................................9
MAINTENANCE.................................................................................................................................................................................................................9
TECHNICAL SPECIFICATIONS..........................................................................................................................................................................................10
TECHNICAL SUPPORT....................................................................................................................................................................................................10
©CHAUVET, 2006, All Rights Reserved Information and specifications in this User Manual are subject to change without
notice. CHAUVET assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.
FS-4200 User Manual 2 2007-02-13
/14:05
Page 3

1. Before You Begin

Unpacking Instructions

Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. must be retur and packing.
ned to the factory, it is important that the fixture be returned in the original factory box
Your shipment includes the following:
1 x Foot Master Switch 1 x Foot Master Relay Pack 1 x Power cable 1 x Serial link cable Warranty Card Users Manual
Save the carton and all packing materials. In the event that a fixture
Note: If you should require sending any items back to CHAUVET, call CHAUVET for a (RA)
Ret
urn Authorization number. The factory will not allow any shipments without an RA.

Contact Us

World Wide
General Information Chauvet Lighting
Technical Support Chauvet Lighting
World Wide Web www.chauvetlighting.com
th
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084
3000 North 29 Hollywood, FL 33020 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attention: Service)
Court
th
Court
FS-4200 User Manual 3 2007-02-13
/14:05
Page 4
Before You Begin
g

Safety Instructions

Please read these instructions carefully, which
includes important information about the installation,
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that y also receive this instruction booklet.
the
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher tha
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit w
The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Always disconnect from power source before servicing or replacing lamp or fuse and
replace with same lamp source.
Secure unit to fastening device using a safety chain.
Maximum ambient temperature (Ta) is 95°F (35°C). Do not operate unit at temperatures higher than
this.
In the event of a serious operating problem, stop using the unit immediately
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Avoid direct eye exposure to the light source while it is on.
Do not daisy chain power to more than 4 units.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET at: 954-929-1115.
e and maintenance of this product.
usa
n that stated on the decal or rear panel of the fixture.
hile operating.
be sure to
. Never try to repair the
FS-4200 User Manual 4 2007-02-13/14:05
Page 5

2. Introduction

Features

Pre-programmed foot controller
Foot controller powered through included relay pack
4 channels with on/off switches
Four chase options:
a) 16 pattern sound activation with sensitivity adjustment
b) Adjustable timed chase
c) Full on override
d) Blackout override
Manual override available for all control options
Includes 1 relay pack with 8 sockets (2 sockets per channel) and S
Additional linkable relay packs available (max 4 units, model: SR-8)
Additional power output for daisy chaining packs together
F-EXCB linking cable
FS-4200 User Manual 5 2007-02-13
/14:05
Page 6
Introduction Introduction
y p
y p

Product Overview

AUTO CHASE
AUTO CHASE
Activates the
Activates the
auto run chase
auto run chase
BLACKOUT
BLACKOUT
Will shut all
Will shut all
lights off
lights off
PEDAL SWITCH
PEDAL SWITCH
Each pedal will turn
Each pedal will turn
on or off power to
on or off power to
devices connected
devices connected
FULL ON
FULL ON
Turn on all
Turn on all
outputs on the
outputs on the
rela
rela
ack.
ack.
SOUND CHASE
SOUND CHASE
Activates the
Activates the sound active
sound active
chase
chase
SPEED
SPEED
CONTROL
CONTROL
POWER
POWER
OUTLET
OUTLET
2 outlets per
2 outlets per
channel
channel
LINK OUT
LINK OUT
Provides connection to
Provides connection to
an optional second
an optional second
SR8 relay pack
SR8 relay pack
AC VOLTAGE
AC VOLTAGE
SWITCH
SWITCH
120V/230V
120V/230V
SOUND
SOUND
SENSITIVITY
SENSITIVITY
CONTROL
CONTROL
RESETTABLE
RESETTABLE
CIRCUIT
CIRCUIT
BREAKER
BREAKER
Built-in Mic.
Built-in Mic.
Power
Power
POWER INPUT
POWER INPUT
POWER
POWER
OUTLET
OUTLET
Always On
Always On
LINK IN
LINK IN
Connects to
Connects to Foot Switch
Foot Switch
HANGING
HANGING BRACKET
BRACKET
LINK OUT
LINK OUT
FS-4200 User Manual 6 2007-02-13/14:05 FS-4200 User Manual 6 2007-02-13/14:05
Page 7

3. Setup

AC Power

Warning! Verify that the power requirement label on your unit matches the line voltage
applied. All fixtures must be connected to circuits with a suitable Earth Ground.
To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average curren
All fixtures must be powered directly off a s
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.
All fixtures must be connected to circuits w
Power Cable Configuration
CABLE Pin International Screw Color
BROWN Live L Yellow or Brass
BLUE Neutral N Silver
YELLOW/GREEN Earth EG (Ground) Green
t draw under normal conditions.
witched circuit and cannot be run off a rheostat
ith a suitable Earth Ground.

Mounting

Orientation
This power relay-pack can be mounted on a truss using a clamp in any position or against a flat surface using the screw holes
Rigging
The relay pack includes (3) clamp mounting holes for convenience of placement. You only need to use one to adhere to a truss or light stand. You must supply your own clamp and make sure the clamp is capable of supporting the weight of the relay pack. You can order C­clamps from any CHAUVET dealer or distributor.
1. Block access below the work area and use suitable and stable platform when installing or servicing the relay pack.
2. Affix clamp to relay-pack u clamp holes provided.
3. Verify the structure can hold 10 times the weight of al
l to-be installed fixtures.
4. Always use a safety cable or chain as a secondary cable must hold 10 times the weight of the accessory. If safety cable attachment point is provided that is permanently affixed to the surface or body of the fixture, use that instead of looping through a hanging yoke/arm.
source of attachment. The safety
sing any of the (3)
Hanging Clamp
Surface
mounting
FS-4200 User Manual 7 2007-02-13
/14:05
Page 8

4. Operating Instructions

Using the FS-4200

The Foot Master™ 4200 comes with a relay pack and foot controller. The relay pack has 16 built in chase patterns that can be triggered either by sound or automatically using the foot controller. The foot controller provides additional control options such as;
Full On : Will turn on all pow
Soun
Au
Blacko
Indi
d : All chase patterns will be triggered via sound, the sensitivity to sound can be adjusted
to : Chase patterns will be triggered at a pre-determined speed
ut : All lights will be turned off momentarily or for as long as you hold the foot button
vidual ON/OFF pedals : Each output can be turned on or off independently.

Connection Diagram

LIGHTING
FIXTURE
er on all receptacles
LIGHTING
FIXTURE
LIGHTING
FIXTURE
LIGHTING
FIXTURE
Provides continuous power to any
Relay Pack
Optional additional SR8 relay pack
Mains Power
FS-4200 User Manual 8 2007-02-13
Serial Link Cable
Please limit your power use on this
output. The relay pack will only allow
device
CAUTION!
15Amps of power.
Foot Master
/14:05
Page 9

5. Appendix

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.

Claims

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.

Maintenance

To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air co collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or becomes dirty, clean the lamps with an alcohol wipe.
The cleaning of internal and external optical lenses and/or mir optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
mpressor and a soft brush to remove dust
rors must be carried out periodically to
FS-4200 User Manual 9 2007-02-13
/14:05
Page 10
Appendix

Technical Specifications

WEIGHT & DIMENSIONS
...............................................................................................................................................Relay Pack
Length...........................................................................................................................
Width ............................................................................................................................
Height.............................................................................................................................
Weight .................................................................................................................................
.............................................................................................................................................
Length........................................................................................................................ 12.0 in (304.8
Width ...........................................................................................................................
Height............................................................................................................................
Weight ..........................................................................................................................
POWER
Operating Voltage .........................................................................................110V 60 Hz or 230V 50 Hz
AC input...........................................................................................................................
Load (110V)...........................................................(10A, 1100W) per channel, (15A, 1650W) maximum
Load (220V)...........................................................(10A, 2200W) per channel, (15A, 3300W) maximum
FUSE
Main................................................................................................................Resettable Circuit Breaker
ORDERING INFORMATION
Foot Master™ 4200....................................................................................................................
8.25 in (210 mm)
7.65 in (194 mm)
2.75 in (70 mm) 5 lbs (2.2 kg)
Foot Switch
mm)
6.5 in (165.1 mm)
3.0 in (76.2 mm)
3.56 lbs (1.59 kg)
IEC 60320 C14
FS-4200

Technical Support

Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com
FS-4200 User Manual 10 2007-02-13/14:05
Loading...