Table of Content
BEFORE YOU BEGIN....................................................................................................................................................... 3
WHAT IS INCLUDED .......................................................................................................................................................................................................... 3
POWER ...........................................................................................................................................................................................................................7
About DMX addressing ....................................................................................................................................................................................10
RGB all sections (4 channels)..........................................................................................................................................................................13
2 x 2 Vertical RGB (7 channels) 2 x 2 Horizontal RGB (7 channels) 2 x 2 Diagonal RGB (7 channels)........................................................13
TECHNICAL SUPPORT ....................................................................................................................................................................................................15
LED-PANEL4 User Manual 2 2006-03-22/12:38
Page 3
BEFORE YOU BEGIN
What is included
1 x LED-PANEL4™
DMX linking cable (RJ45 connector)
DMX input cable (3-Pin XLR to RJ45 converter)
Power cable (2-pin connector to IEC)
Warranty Card & User Manual
Unpacking Instructions
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular product, see the label affixed to the back plate
of the product or refer to the product’s specifications chart. A product’s listed current rating is its
average current draw under normal conditions. All fixtures must be powered directly off a switched
circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or
dimmer channel is used solely for a 0% to 100% switch. Before applying power, check that the source
voltage matches the product’s requirement.
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive
this instruction booklet.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is
not higher than that stated on decal or rear panel of the
fixture.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure
that no ventilation slots are blocked.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same
lamp source.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
Secure fixture to fastening device using a safety chain.
Never carry the fixture solely by its head. Use its carrying
handles.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself.
Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the
same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the
cord.
Avoid direct eye exposure to lamp while it is on.
LED-PANEL4 User Manual 3 2006-03-22/12:38
Page 4
individual panel
INTRODUCTION
Features
CONTROL FEATURES
3 ~ 13 channel DMX-512 LED panel system
Operating modes
- 13 channel mode: 4 sections of RGB mix control
- 7 channel mode: 2x2 Vertical RGB mix control
- 7 channel mode: 2x2 Horizontal RGB mix control
- 7 channel mode: 2x2 Diagonal RGB mix control
- 4 channel mode: Single RGB mix control
- 3 channel mode: Auto/Sound active, program and speed select
FEATURES
112 LEDs total in 4 panels, 28 LEDs per panel surface
- Red (40), Green (36) and Blue (36)
Ultra bright LEDs
RGB color mixing
Built in color change programs
Low power consumption
Up to 100,000-hour LED life span
Master/Slave mode
DMX Channel Summary
Blackout
CHDESCRIPTION
1
DMX: (000~010)
4 Channel Configuration
All Panels RGB Mix
CHDESCRIPTION
1
DMX: (011~045)
2
All Red
3
All Green
4
All Blue
7 Channel Configurations
Various (2x2) and
CHDESCRIPTION
1
DMX: (046~150)
2
Red
3
Green
4
Blue
5
Red
6
Green
7
Blue
13 Channel Configuration
RGB Mix
CHDESCRIPTION
1
DMX: (151-185)
2
Red
Section 1
Section 2
Section 3
Section 4
10
11
12
13
3
Green
4
Blue
5
Red
6
Green
7
Blue
8
Red
9
Green
Blue
Red
Green
Blue
3 Channel Configurations
CH
DESCRIPTION
Auto Run
DMX: (186~220)
1
Sound Run
DMX: (221~255)
2
Program Select
3
Speed adjust
For a detailed view of DMX values turn to the Appendix section in this manual.
LED-PANEL4 User Manual 4 2006-03-22/12:38
Page 5
Introduction
Built in microphone for
Large white diffused panel
Wall mount hooks
Power cable
XLR to Ethernet (RJ45) cable
Ethernet cable
Product Overview
Packing
refracts all light emitted
from four internal LEDs
panel sections to produce
one evenly spread wash of
any color. In addition, each
internal panel section can
also be controlled
independently.
(XLR 3-pin to Ethernet
RJ45 cable)
sound-active operation.
LED-PANEL4 User Manual 5 2006-03-22/12:38
Page 6
mounting.
accessory provided.
switch
Master/Slave
RJ45 connectors used for
Up to 127 panels can be powered from one
20 Amp outlet and using the attached
power link cable.
Screw or hook
holes for flush
Wall mount hook
Master/Slave
Built in and
adjustable freestanding support
for table top or
other horizontal
surface positions.
Ethernet RJ45
connectors for daisy
chain link of Panels.
Dipswitches used
for Master/Slave
and DMX
addressing.
switch
DMX linking. XLR to RJ45
converter used for the first
fixture, Ethernet cables for
continued link.
LED-PANEL4 User Manual 6 2006-03-22/12:38
Page 7
Free
-
standing option
SETUP
Power
The LED-PANEL4™ can operate in voltages between 100V~240V 50Hz or 60Hz. It is equipped with
an auto sensing transformer.
To determine the power requirements for a particular fixture, see the label affixed to the back plate
of the fixture or refer to the fixture’s specifications chart.
A fixture’s listed current rating is its average current draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
Before applying power to a fixture, check that the source voltage matches the fixture’s
requirement.
All fixtures must be connected to circuits with a suitable Earth Ground.
Power Cable Configuration
CABLE (EU) CABLE (US) PININTERNATIONAL
BROWN
BLUE
YELLOW/GREEN
Black Live L
White Neutral N
Green Earth EG (Ground)
Mounting
Orientation
Diffused surface should face the
environment with the back side either
flush mounted or using flush mount
hardware provided. No specific
orientation is required. The product is
not intended to be used in place of
ceiling tiles. Please make sure to
follow proper load bearing limitations if
mounting on the ceiling.
Rigging
The fixture includes 4 plastic wall
mounting accessory pieces for wall
surface mount.
1. Draw a screw hole template on a large
piece of vellum or transparent paper
for best alignment.
2. Place paper against the mounting surface and drill
holes or mark the surface for drilling.
3. Mount plastic accessory and screw into place.
4. Hang Panel.
LED-PANEL4 User Manual 7 2006-03-22/12:38
Page 8
the back of the panel
Adapter provided
OPERATING INSTRUCTIONS
The COLORpanel™ 4 is a DMX-512 controllable, full RGB color mix led tile fixture made up of highly
efficient and super bright LEDs. There are four led panels whose intensity can be controlled either
individually or together allowing the creation of an unlimited range of colors.
The COLORpanel™ 4 can operate in Stand-Alone, Master/Slave and via DMX-512 control utilizing
anywhere between 4 and 13 channels.
Connection Diagram
Whether you want to control the COLORpanel™ using DMX or via its’ built in programs the
connection method remains the same.
Power
2 pin male/female connectors
Master/Slave
1. First panel set to
Master.
2. All following
panels set to Slave.
Up to 127 fixtures can be
connected in series on one
20Amp power outlet.
XLR to RJ-45
Universal DMX-512 Controller
RJ45 Ethernet cables used for DMX signal
In a Master/Slave mode the first fixture in the chain requires the switch on
the Master side and in all other following Panels, the switch on the Slave
side You can also run each Panel in a Master state independently.
Master/Slave switch located in
Master/Slave & Stand Alone Modes
The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In
this mode, the first unit in the daisy chain will automatically command all other units following. Stand
Alone can simply be achieved by setting all units to Master. They would no longer be required to be
linked in series using the Ethernet or data cables.
1. Follow the instructions in the Connection Diagram section above.
2. Set dipswitch settings to select internal programs and their speed by following the chart on the
following page.
IMPORTANT!
FOR CONTROL USING DMX,
PLEASE READ THE SECTION
ON DMX CONTROL
THOROUGHLY!!
LED-PANEL4 User Manual 8 2006-03-22/12:38
Page 9
Dipswitch Options
1098765432
1
Change the dipswitches as described below to
enable any one of the 16 built in programs. In
addition one of 16 speeds can also be selected.
Dipswitch # 10 in the ON position will change the
fixture to Sound mode.
Legend
0 = Dipswitch in the OFF position
1 = Dipswitch in the ON position
1. Set dipswitch # 10 to the ON position for Sound Mode. Switch back to OFF for Auto.
DMX Control Mode
Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to
customizing or creating a show. In this mode you will be able to control each individual trait of the
fixture and each fixture independently.
1. Connect the panels by following the “Connection Diagram” section of this manual.
2. Set all fixtures to SLAVE and leave dipswitch # 10 in the OFF position.
LED-PANEL4 User Manual 9 2006-03-22/12:38
Page 10
Operating Instructions
About DMX addressing
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start
address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data
on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels
of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101,
102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate
the start address selected for future reference.
If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping
to the Appendix Section and read the heading “DMX Primer”. It contains very useful information that
will help you understand its use.
Set the start address using the group of DIP switches located near the “Maser/Slave switch”. Each
dipswitch has an associated value. These values may not be screen printed on the fixture but will be
represented in these instructions. Adding the value of each switch in the ON position will provide the
start address. Determining which switches to toggle ON given a specific start address can be
accomplished in the following manner. By subtracting the largest switch value possible from the
selected start address which does not cause a negative number. This is obviously a good reference;
however continue on for a visual guide.
EXAMPLE STARTING ADDR
Address 10
Pin # 4 = 8
Pin # 2 = 2
Total = 10
Address 24
Pin # 5 = 16
Pin # 4 = 8
Total = 24
Resolving address using
simple math.
Address 233
ON
1
ON
1
233 – (128) = 105, Turn ON Dip # 8
105 – (64) = 41, Turn ON Dip # 7
41 – (32) = 9, Turn ON Dip # 6
9 – (8) = 1, Turn ON Dip # 4
1 – (1) = 0, Turn ON Dip # 1
You will most likely use the first available
number which maybe number 1. This
number was selected for example
purposes.
8
4
2
8
4
2
10987654321
256
128
64
32
16
10987654321
256
128
64
32
16
DIP SWITCH(DMXVALUE)
1
2
3
4
5
6
7
8
9
10
1
2
4
8
16
32
64
128
256
LED-PANEL4 User Manual 10 2006-03-22/12:38
Page 11
Example: DMX channel addressing
Fixture # 1: DMX 001
Fixture # 2: DMX 014
Fixture # 3: DMX 027
Fixture # 4: DMX 040
Fixture # 5: DMX 053
There are 6 different DMX control configuration on the LED-PANEL4, ranging from 3 channels and up
to 13 channels. These configurations are set using the first channel of DMX control on each fixture.
We suggest that in order to avoid fixture overlapping of controls you dedicate 13 channels of control
to every LED-PANEL4 unless you are an experienced operator. In this example we will separate each
fixture by 13 channels of control.
ON
ON
ON
ON
1
2
1
2
1
2
1
2
16
8
4
987654321
256
128
64
32
16
8
4
987654321
256
128
64
32
16
8
4
987654321
256
128
64
32
16
8
4
987654321
256
128
64
32
LED-PANEL4 User Manual 11 2006-03-22/12:38
ON
1
2
16
8
4
987654321
256
128
64
32
Page 12
APPENDIX
COMMON
DMX +
DMX -
1 3 2 1 3 2 1 3 2
educes signal errors and to
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
Fixture Linking
DMX connector configuration
INPUT
OUTPUT
Termination r
avoid signal transmission problems and
interference, it is always advisable to
connect a DMX signal terminator.
Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5
pin to 3 pin adapter. CHAUVET Model No: DMX5M.
The chart below details a proper cable conversion:
3PIN TO 5PIN CONVERSION CHART
Conductor
Ground/Shield
Data ( - )signal
Data ( + ) signal
Do not use
3 Pin Female (output) 5 Pin Male (Input)
Pin 1 Pin 1
Pin 2 Pin 2
Pin 3 Pin 3
Do not use
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
Do not use
LED-PANEL4 User Manual 12 2006-03-22/12:38
Do not use
Page 13
Operating Instructions
DMX Channel Values
NOTE!
Please read all instructions carefully on fixture DMX control mode and addressing.
Channel 1 remains the same in every control configuration
CHANNELVALUEFUNCTION
Blackout & DMX Channel Configurations
000 010
011 045
046 080
1
081 115
116 150
151 185
186 220
221 255
RGB all sections (4 channels)
CHANNELVALUEFUNCTION
2
000 255
3
000 255
4
000 255
Blackout
RGB all sections (4 channels)
2 x 2 Vertical RGB (7 channels)
2 x 2 Horizontal RGB (7 channels)
2 x 2 Diagonal RGB (7 channels)
4 separate RGB (13 channels)
Auto Mode: Program (ch2) , Speed (ch3)
Sound Mode: Program (ch2), Speed (ch3)
Red: 0 > 100%
Green: 0 > 100%
Blue: 0 > 100%
All Sections
2 x 2 Vertical RGB (7 channels)
2 x 2 Horizontal RGB (7 channels)
2 x 2 Diagonal RGB (7 channels)
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
LED-PANEL4 User Manual 14 2006-03-22/12:38
Page 15
Operating Instructions
Technical Specifications
WEIGHT & DIMENSIONS
Length......................................................................................................................500 mm (19.69 in)
Width........................................................................................................................500 mm (19.69 in)
Height ..........................................................................................................................37 mm (1.46 in)