Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
Page 2
TABLE OF CONTENTS
1. BEFORE YOU BEGIN................................................................................................................................ 3
HAT IS INCLUDED......................................................................................................................................... 3
POWER ................................................................................................................................................... 3
USE REPLACEMENT...................................................................................................................................... 7
Data Cabling........................................................................................................................................... 7
DMX Data Cable............................................................................................................................... 7
¾ 1 x COLORpalette™ 2
¾ 2 x Flush mount brackets
¾ 1 x Wall/Truss mounting bracket
¾ Power Cord
¾ Warranty Card
¾ User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
This fixture has an auto-switching power supply that can accommodate a wide range of input
voltages. The only thing necessary to do before powering on the unit is to make sure the line voltage
you are applying is within the range of accepted voltages. This fixture will accommodate between
100V and 240V AC. All fixtures must be powered directly off a switched circuit and cannot be run off a
rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for
a 0% to 100% switch.
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance of this
product.
•Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
•Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
• This product is intended for indoor use only!
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no
flammable materials close to the unit while operating.
•The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked.
•Always disconnect from power source before servicing or replacing lamp or fuse and be sure to
replace with same lamp source.
•Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use
its carrying handles.
•Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher
than this.
•In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
• Don’t connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
• Do not daisy chain power to more than 8 units.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET at: 954-929-1115.
COLORpalette 2 User Manual 4 2008-01-10/13:06
Page 5
2.INTRODUCTION
Features
• 6, 9, 15 or 27-channel DMX-512 LED panel
• Operating modes
6-channel: RGB control
9-channel: 2 sections of RGB control
15-channel: 4 sections of RGB control
27-channel: 8 sections of RGB control
• Built-in automated programs via master/slave or DMX
• Built-in sound activated programs via master/slave or DMX
Additional Features
• High-power, 1W (350mA) LEDs
• Additional power output: max 8 units @ 120V (see manual for details)
• Includes brackets for wall or truss mounting
DMX Channel Summary (27 channel mode)
CHANNEL FUNCTIONCHANNEL FUNCTIONCHANNEL FUNCTION
1
Mode
10
Red 3
19
Red 6
2
3
4
5
6
7
8
9
Auto Speed
Strobe
Red 1
Green 1
Blue 1
Red 2
Green 2
Blue 2
11
12
13
14
15
16
17
18
Green 3
Blue 3
Red 4
Green 4
Blue 4
Red 5
Green 5
Blue 5
DMX Channel Summary (15 channel mode)
CHANNEL FUNCTIONCHANNEL FUNCTIONCHANNEL FUNCTION
1
2
3
4
Mode
Auto Speed
Strobe
Red 1
6
7
8
9
Blue 1
Red 2
Green 2
Blue 2
20
21
22
23
24
25
26
27
11
12
13
14
Green 6
Blue 6
Red 7
Green 7
Blue 7
Red 8
Green 8
Blue 8
Green 3
Blue 3
Red 4
Green 4
5
COLORpalette 2 User Manual 5 2008-01-10/13:06
Green 1
10
Red 3
15
Blue 4
Page 6
r
DMX Channel Summary (9 channel mode)
CHANNEL FUNCTIONCHANNEL FUNCTIONCHANNEL FUNCTION
1
Mode
4
Red 1
7
Red 2
2
3
Auto Speed
Strobe
5
6
DMX Channel Summary (6 channel mode)
CHANNEL FUNCTIONCHANNEL FUNCTIONCHANNEL FUNCTION
1
2
Mode
Auto Speed
3
4
Product Overview
Power
Connector and
Fuse Holder
Mounting
Bracket
Mode
Button
Green 1
Blue 1
Strobe
Red 1
Mode
Display
8
9
5
6
Green 2
Blue 2
Green 1
Blue 1
Up
Button
Sound
Sensitivity
Knob
DMX
Output
Connector
DMX Input
Connecto
COLORpalette 2 User Manual 6 2008-01-10/13:06
Enter
Button
Status
Display
Down
Button
Page 7
3.SETUP
Disconnect the power cord before replacing a fuse and always
replace with the same type fuse.
Fuse Replacement
With a flat head screwdriver wedge the fuse
holder out of its housing. Remove the damaged
fuse from its holder and replace with exact
same type fuse. Insert the fuse holder back in
its place and reconnect power.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller
or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a serial data link determines the number
of fixtures the data link can support.
Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485
Maximum recommended serial data link distance: 500 meters (1640 ft.)
Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.
The fuse is located
inside this
compartment.
Remove using a flat
head screwdriver.
standard no more than 32 devices should be connected on one data link. Connecting more than 32
fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in
deterioration of the digital DMX signal.
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor and shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms
COLORpalette 2 User Manual 7 2008-01-10/13:06
Page 8
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
INPUT
1
3
2
DMX
+
-
CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common
can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to
verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.
3-PIN TO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter.
CHAUVET Model No: DMX5M, or DMX5F.
The chart below details a proper cable conversion:
PIN TO 5PIN CONVERSION CHART
3
Conductor 3 Pin Female (output) 5 Pin Male (Input)
Ground/Shield Pin 1 Pin 1
Data ( - ) signal Pin 2 Pin 2
Data ( + ) signal Pin 3 Pin 3
Do not use Do not use
Do not use Do not use
1
3
2
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
1
OUTPUT
3
Termination reduces signal errors and
2
to avoid signal transmission problems
and interference, it is always
advisable to connect a DMX signal
terminator.
Setting up a DMX Serial Data Link
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector
to the input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and
This drawing provides a
general illustration of the
DMX Input/Output panel of
a lighting fixture.
Page 9
y
Master/Slave Fixture Linking
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.
Often, the setup for Master-Slave
and Standalone operation requires
that the first fixture in the cha in be
initialized for this purpose via either
settings in the control panel or DIPswitches. Secondarily, the fixtures
that follow may also require a slave
setting. Please consult the
“Operating Instructions” section in
this manual for complete ins tructions
for this type of setup and
configuration.
Mounting
ORIENTATION
RIGGING
This fixture may be mounted in any position provided there is adequate room for ventilation.
It is important never to obstruct the fan or vents pathway. Mount the
fixture using, a suitable “C” or “O” type clamp. Adjust the angle of the
fixture by loosening both knobs and tilting the fixture. After finding the
desired position, retighten both knobs.
•When selecting installation location, take into consideration lamp
replacement access and routine maintenance.
• Safety cables should always be used.
• Never mount in places where the fixture will be exposed to rain, high
humidity, extreme temperature changes or restricted ventilation.
Note!
Clamp is sold separatel
Hanging Clamp
.
COLORpalette 2 User Manual 9 2008-01-10/13:06
Page 10
4.OPERATING INSTRUCTIONS
Navigating the Control Panel
Access control panel functions using the four panel buttons located directly underneath the LCD
Display.
Menu Map
Button Function
<MODE>
<UP>
<DOWN>
<ENTER>
The Control Panel LED Display shows the menu items you select from the menu map on page 13.
When a menu function is selected, the display will show immediately the first available option for the
selected menu function. To select a menu item, press <ENTER>.
Press the <MODE> button once to activate the control panel. Pressing the <MODE> button again will
scroll through the different top-level menu options available. Use the <UP> and <DOWN> buttons to
navigate the menu options. Press the <ENTER> button to access the menu function currently
displayed or to enable a menu option. To return to the previous option or menu without changing the
value, press the <MODE> button.
Used to access the menu or to return to a
previous menu option
Scrolls through menu options in ascending
order
Scrolls through menu options in descending
order
Used to select and store the current menu
or option within a menu
Solid On
Strobe (Slow > Fast)
Sound-active Strobing
Auto Run Delay (Auto/Sound Modes Only)
Never Auto run
Time Delay (Long > Short)
No Delay
Menu Functions
MENU
OPTION
DESCRIPTION
Auto Mode – Stand-alone: Sets the fixture to Master status for
Master-Slave operation and the built in programs will be
triggered by the sound. No data link is required; all fixtures
can be set to this mode for Stand-alone operation.
DMX: The fixture will be controlled by a DMX signal coming from
a DMX controller. The starting address must be selected, and
can be set using the up and down buttons.
Strobe Mode: Sets the fixture to strobe the selected color.
This setting is only available when the unit is set to display
a static color in standalone mode (A001-A007).
Auto Run Delay: If the unit does not trigger with sound within
a certain time period, it can automatically enter auto mode.
This setting controls the time delay before entering auto mode.
Note that auto mode is cancelled as soon as the unit triggers
with sound.
COLORpalette 2 User Manual 11 2008-01-10/13:06
Page 12
Operation
Stand-Alone Mode (Sound-Active, Auto Mode):
This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto
Mode.
1) Press the <MODE> button.
2) Use the <UP> and <DOWN> buttons to locate the desired program (A001 – A024). Some
programs are static, and some can trigger to sound. See the Menu Values section on the
previous page for a complete list of programs.
3) Each program has settings which can be configured by pressing <ENTER> while the program is
displayed. Press <ENTER> while the program is displayed. Scroll through to the desired setting
and press <MODE>. See the Menu Values section on the previous page for a complete list of
settings.
3) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in
Sound-Active mode. Turning the knob counterclockwise decreases the sensitivity; turning the
knob clockwise increases the sensitivity.
Master/Slave Mode (Master Sound, Master Auto):
This mode will allow you to link up to 32 units together without a controller.
1) Use standard DMX cables to daisy chain your units together via the DMX connector on the rear
of the units. For longer cable runs we suggest a terminator at the last fixture. For more
information about terminators, see page 8.
DMX Mode
Note: The “d” will disappear after pressing the enter button. This is to indicate that you are in DMX
2) Determine which fixture will be the master. Connect a DMX cable from the DMX output
connector of the master to the DMX input connector of another COLORpaIette™ 2.
3) Continue connecting the slaves together with DMX cables
4) Press the <MODE> button on the master.
5) Use the <UP> and <DOWN> buttons to locate the desired program (A001 – A024). Some
programs are static, and some can trigger to sound. See the Menu Values section on the
previous page for a complete list of programs.
6) Each program has settings which can be configured by pressing <ENTER> while the program is
displayed. Press <ENTER> while the program is displayed. Scroll through to the desired setting
and press <MODE>. See the Menu Values section on the previous page for a complete list of
settings.
7) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in
Sound-Active mode. Turning the knob counterclockwise decreases the sensitivity; turning the
knob clockwise increases the sensitivity.
This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with
DMX, please read the DMX Primer on page 15.
1) Press the <MODE> button.
2) Use the <UP> and <DOWN> buttons until
mode, and can now change the DMX address.
3) Use the <UP> and <DOWN> buttons to select the desired DMX address.
Make sure you have the correct audio mode on the
control switches. If audio provided via ¼” jack, make
sure a live audio signal exists
Adjust sound sensitivity knob
Possible bad lamp or fixture is overheating.
Lamp may be at end of its life.
Some discharge lamps require a cooling off period
before the electronics in the fixture can kick start it
again, wait 5 to 10 minutes before powering up
Install terminator
Note: Keep DMX cables separated from power cables
or black lights.
Lights
9
9
Foggers
& Snow
Controllers
Dimmers
& Chaser
9
9
9
9 9
9 9
9
9
9
9 9
9 9 9 9
9
9
No flash Re-install bulb, may have shifted in shipping
No laser output Bounce mirror motor may have shifted during shipping,
readjust
No light output Check slip ring & brushes for contact
Install bulb
Call service technician
Relay will not work Check reset switch
Check cable connections
Remote does not
work
Stand alone mode All Chauvet lighting fixtures featuring stand-alone
COLORpalette 2 User Manual 14 2008-01-10/13:06
Make sure connector is firmly connected to device
functions do not require additional settings, simply
power the fixture and it will automatically enter into this
mode
If you still have a problem after trying the above solutions, please contact CHAUVET Technical
Support at the location on the next page.
9
9
9
9 9
9
9
Page 15
Technical Support
Address: Service Dept.
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)
Support (Email): tech@chauvetlighting.com
Telephone: (954) 929-1115 - (Press 4)
Fax: (954) 929-5560 - (Attention: Service)
Website: http://www.chauvetlighting.com
5.APPENDIX
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
COLORpalette 2 User Manual 15 2008-01-10/13:06
Page 16
General Maintenance
To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage
and environment are contributing factors in determining frequency. As a general rule, fixtures should
be cleaned at least twice a month. Dust build up reduces light output performance and can cause
overheating. Be sure to power off fixture before conducting maintenance.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when the fixture is cold with a
mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply
solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical
surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s
optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean
the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Note: If you are given an RA #, please include the following information on a piece of paper
inside the box:
1) Your name
2) Your address
3) Your phone number
4) The RA #
5) A brief description of the symptoms
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
COLORpalette 2 User Manual 16 2008-01-10/13:06
Page 17
Technical Specifications
WEIGHT & DIMENSIONS
Length........................................................................................................................... 18.5 in (470 mm)
Width .............................................................................................................................. 7.8 in (198 mm)
Height................................................................................................................................3.5 in (89 mm)
Weight ..............................................................................................................................8.4 lbs (3.8 kg)
POWER
Autoswitching Power Supply...................................................................................100 – 240V 50/60Hz
Fuse.................................................................................................20mm Glass 3.15A 250V Fast Blow
Power Consumption 120V 60Hz ........................................................................... 58W (0.6A) operating
Inrush Power ....................................................................................................................................... 2A
Power Factor.....................................................................................................................................0.75