CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
2005-10-10/16:02
Page 2
Table of Content
BEFORE YOU BEGIN....................................................................................................................................................... 3
WHAT IS INCLUDED .......................................................................................................................................................................................................... 3
CONTROL PANEL .............................................................................................................................................................................................................6
MENU DIAGRAM...............................................................................................................................................................................................................6
SYSTEM SETUP ............................................................................................................................................................................................................... 6
SINGLE ACTION PROGRAMS.............................................................................................................................................................................................7
Choosing Single Action Programs .....................................................................................................................................................................7
Setting the DMX address ................................................................................................................................................................................... 8
Running in DMX Mode.......................................................................................................................................................................................8
TECHNICAL SUPPORT ....................................................................................................................................................................................................12
LED-CHVA User Manual 2 2005-10-10/16:02
Page 3
AC Voltage Switch Example
BEFORE YOU BEGIN
What is included
COLORcontroller™ 2.0
1 x LED-CHVA COLORcontroller™ 2.0
1 x LED-SIG15A Signal Extension Cable
1 x AC-DC Power Adapter
Manual and Warranty Card
Unpacking Instructions
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular product, see the label affixed to the back plate
of the product or refer to the product’s specifications chart. A product’s listed current rating is its
average current draw under normal conditions. All fixtures must be powered directly off a switched
circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or
dimmer channel is used solely for a 0% to 100% switch. Before applying
power, check that the source voltage matches the product’s requirement.
Check the product or device carefully to make sure that if a voltage
selection switch exists that it is set to the correct line voltage you will use.
Warning! If applicable, verify that the power select switch on your unit
matches the line voltage applied. All fixtures must be
connected to circuits with a suitable Earth Ground.
Notice!
The LED COLOR - - - -™ 2.0 System Series is not
compatible with the previous non 2.0 system.
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive
this instruction booklet.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is
not higher than that stated on decal or rear panel of the
fixture.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure
that no ventilation slots are blocked.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same
lamp source.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
LED-CHVA User Manual 3 2005-10-10/16:02
Secure fixture to fastening device using a safety chain.
Never carry the fixture solely by its head. Use its carrying
handles.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself.
Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the
same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the
cord.
Avoid direct eye exposure to lamp while it is on.
programmed chases adjustable in speed or flash rate,
Auto mode and Sound Active
Speed control channel
Flash rate control channel (1-20 Fps)
Selection of preset color combinations
Features
1000 tubes
30 varied patterns (with color changes)
Built in Microphone
Digial LCD display
DMX Channel Summary
CHANNELFUNCTION
1
2
3
4
Color, Programs, Auto
Color Combinations
Speed
Flash
LED-CHVA User Manual 4 2005-10-10/16:02
Page 5
Introduction
A B C D
Product Overview
SEGMENT BUTTONS
BUTTONS
Mode
Setup
Up
Down
ITEMDESCRIPTION
A
3-Pin female XLR DMX output connector
B
3-Pin male XLR DMX input connector
C
COLORtube™ 2.0 signal output
D
DC input
Returns to Main Menu
Enter menu selection
Steps backward through
menu functions
Steps forward through
menu functions
SETUP
LED-CHVA Controller
LED-PC5A Power cable connects to AC outlet
The diagram above illustrates the tubes connected in series or as required for normal operation. Both plugs are unique in that one is a
2-pin and the other a 4-pin. Connect each tube in series by each matching connector and plug. The 2-pin connector is used for power.
The 4-pin connector is used for signal.
For every 30 tubes connected you will need a signal booster (LED-BOOSTA) and a power connection (LED-PC5A) to a
different AC outlet.
LED-CHVA User Manual 5 2005-10-10/16:02
Page 6
M System Setup
M Single Action
Main Menu
1 DMX Ch
(0 – 508)
For a detailed listing of Single
OPERATING INSTRUCTIONS
Control Panel
On the control panel you can set the controller for single action mode where preset programs are run
either statically, automatically or by sound-activation or assign a starting DMX channel address.
[MODE] Returns to Main menu or step backward through functions
[SET UP] Enters menu selection
[UP] Steps backward through menu selection
[DOWN] Steps forward through menu selection
MODE SETUP UP DOWN
Menu Diagram
System Setup
You will need to let the controller be aware of the number of tubes connected in series. This is
essential in order for the chase and flow programs to perform correctly through out the entire stretch
of tubes.
Initial Setup
1. Press the MODE button until the display shows “M System Setup”.
2. Press the SETUP button then the UP button once. It will show “3 Tube Amount”.
3. Press the SETUP button to enter the function. A number will now appear to the right of the text as
4. Use the UP and DOWN buttons to locate a number between 0 and 999. This represents the
5. Press the MODE button to set this function.
Re-initialization
Whenever a tube is removed, replaced or exchanged please follow the following instructions.
1. Press the MODE button until the display shows “M System Setup”.
2. Press the SETUP button then the UP button twice. It will show “2 Set Address”.
3. Press the SETUP button to re-initialize.
4. Proceed to prior instruction “Initial Setup” and re-do.
2 Set Address (N / A)
3 Tube Amount (0 – 999)
shown here in an example. “3 Tube Amount 34”.
number of tubes connected.
Action programs proceed to the
next page.
LED-CHVA User Manual 6 2005-10-10/16:02
Page 7
Operating Instructions
Single Action Programs
Single Action programs are pre-built chase and flow patterns. They can be executed either manually
or by DMX control. Depending on the program the following attributes can be modified; Run Speed,
Flash Frequency and Color Selection.
NUMBERPROGRAMTYPEMODIFICATIONS (MODIFIER)
1 Black Static None
2 Red Static None
3 Green Static None
4 Blue Static None
5 Yellow Static None
6 Purple Static None
7 Cyan Static None
8 White Static None
9 Color Change Auto Run Speed, Flash Speed
10 Slow Flow 1 Auto Run Speed, Flash Speed
11 Slow Flow 2 Auto Run Speed, Flash Speed
12 Roll Chase 1 Auto Run Speed, Flash Speed
13 Roll Chase 2 Auto Run Speed, Flash Speed
14 Multi Color Auto Run Speed, Flash Speed
15 Fast Flow 1 Auto Run Speed, Flash Speed
16 Fast Flow 2 Auto Run Speed, Flash Speed
17 Fast Flow 3 Auto Run Speed, Select Color Combination (1)
18 Fast Flow 4 Auto Run Speed, Select Color Combination (1)
19 2 Color Chase Auto Run Speed, Flash Speed, Select Color Combination (1)
20 2 Color Flow Auto Run Speed, Flash Speed, Select Color Combination (1)
21 Color Fade Auto Run Speed
22 Auto Run Auto Run Speed, (runs all built in programs)
(1) Refer to “DMX Channel Values” for Color Combinations Table.
Choosing Si ngle Action Programs
1. Press the MODE button until the display shows “M System Setup”.
2. Press the UP button to arrive at “M Single Action”.
3. Press the SETUP button to enter menu function.
4. Press the UP and DOWN buttons to toggle built in programs. Press SETUP button to choose the
presently viewed program number.
5. Upon selecting the program, the menu will immediately display whatever modifier may exist for
that individual program selected. It can display “Flash Speed: 100” or “Run Speed: 100” for
example. Pressing the SETUP button will toggle the various modifiers available for the program as
listed in the table above.
6. Use the
7. Press the MENU button to retain the new settings..
8. Press
UP and DOWN buttons to adjust the values of modifiers accordingly. Remember that
SETUP will toggle the various options while UP and DOWN changes the values.
MENU again if necessary to return to the Main Menu.
LED-CHVA User Manual 7 2005-10-10/16:02
Page 8
DMX Control Mode
From Controller
With exception to the system setup process all control functions on the controller can be accessed
and executed externally via a Universal DMX controller. First you must connect the LED-CHVA
controller to an existing DMX daisy chain. The controller is addressable just like any other DMX
device or fixture and it will be controlled as if it were a fixture in most intelligent light consoles.
Setting the DMX address
1. Press the MODE button until the display shows “M System Setup”.
2. Press the SETUP button to enter the “M System Setup” menu function.
3. The controller should display immediately “1 Dmx Ch”. Press the SETUP button to select function.
4. Use the UP and DOWN buttons to increase or decrease the channel values. This value represents
the starting address for this device. The controller occupies 4 channels of DMX
5. The unit will now respond to DMX command. Do not press any other buttons other than to change
the channel values.
The next step may require you to create a device profile within your lighting controller. Proceed to
section “DMX Channel Values” for a detailed chart of the control values for each channel of DMX.
Running in DMX Mode
If the control panel menu displays “1 Dmx Ch“ press SETUP to activate DMX control mode. For
instructions on arriving at this menu item repeat the instructions “Setting the DMX address” located
directly above this subject.
Operating Instructions
Daisy Chain Connection
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector
of the first fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,
proceed to connect from the output as stated above to the input of the following fixture and so on.
DMX Daisy Chain
COLORtube™ 2.0
COLORcontroller™ 2.0
LED-CHVA User Manual 8 2005-10-10/16:02
Page 9
APPENDIX
COMMON
DMX +
DMX -
1 3 2 1 3 2 1 3 2
Termination reduces signal errors and to
DMX Primer
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A
fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user
must assign a starting address on the fixture that indicates the first channel reserved in the controller.
There are many different types of DMX controllable fixtures and they all may vary in the total number
of channels required. Choosing a start address should be planned in advance. Channels should
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is
set incorrectly. You can however, control multiple fixtures of the same type using the same starting
address as long as the intended result is that of unison movement or operation. In other words, the
fixtures will be slaved together and all respond exactly the same.
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which
the fixtures are connected is not important and has no effect on how a controller communicates to
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET
carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
Figure 1 - DMX connector configuration
INPUT
OUTPUT
avoid signal transmission problems and
interference, it is always advisable to
connect a DMX signal terminator.
Resistance 120
ohm 1/4w between
pin 2 (DMX -) and
pin 3 (DMX +) of
the last fixture.
Fixture Linking
Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5
pin to 3 pin adapter. CHAUVET Model No: DMX5M.
The chart below details a proper cable conversion:
Black
Red
Green
Blue
Yellow
Purple
Light Blue
White
Color Change
Slow Flow 1
Slow Flow 2
Roll Chase 1
Roll Chase 2
Multi Color
Fast Flow 1
Fast Flow 2
Fast Flow 3
Fast Flow 4
2 Color Chase
2 Color Flow
Color Fade
Auto Run
Run Speed
Slow > Fast, (1 step/Minute) > (100 steps/Second)
Flash Speed
Always On
Slow > Fast (1 – 20Hz)
Color Combinations
Red & Green
Red & Yellow
Red & Blue
Red & Purple
Red & Cyan
Red & White
Green & Yellow
Green & Blue
Green & Purple
Green & Cyan
Green & White
Yellow & Blue
Yellow & Purple
Yellow & Cyan
Yellow & White
Blue & Purple
Blue & Cyan
Blue & White
Purple & Cyan
Purple & White
Cyan & White
LED-CHVA User Manual 10 2005-10-10/16:02
Page 11
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate
packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe
method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim
for items such as missing component/part, damage not related to shipping, and concealed damage,
must be made within seven (7) days of receiving merchandise.
LED-CHVA User Manual 11 2005-10-10/16:02
Page 12
Appendix
Technical Specifications
WEIGHT & DIMENSIONS
Length.....................................................................................................................205.74 mm (8.1 in)
Width..........................................................................................................................101.60 mm (4 in)
Height .......................................................................................................................30.48 mm (1.2 in)