If the box or the contents (the product and included accessories) appear damaged from
shipping, or show signs of mishandling, notify the carrier immediately, not CHAUVET®.
Failure to report damage to the carrier immediately may invalidate your claim. In
For other issues, such as missing components or parts, damage not related to shipping,
Text
1~512
A range of values
50/60
A set of values of which only one can be chosen
Settings
A menu option not to be modified
Menu > Settings
A sequence of menu options to be followed
<ENTER>
A key to be pressed on the product’s control panel
ON
A value to be entered or selected
Symbols
Critical installation, configuration, or operation information. Not
damage to the product, or cause harm to the operator.
Document
are subject to change
ity for any errors or
1.BEFORE YOU BEGIN
Claims
Conventions
• COLORbar™ SMD
• Locking Power Cord
Carefully unpack the product immediately
parts are in the package and are in good condition.
addition, keep the box and contents for inspection.
or concealed damage, file a claim with CHAUVET® within 7 days of delivery.
Convention Meaning
Symbol Meaning
• Warranty Card
• Quick Reference Guide
Information
following these instructions may make the product not work, cause
Important installation or configuration information. The product
may not function correctly if this inform ation is not used.
Useful information.
The information and specifications contained in this User Manual
without notice. CHAUVET® assumes no responsibility or liabil
omissions, and reserves the right to revise or recreate this manual at any time.
Download the latest version from www.chauvetlighting.com.
You can download the latest version of this document from www.chauvetlighting.com.
Electronically published by CHAUVET® in the United States of America.
Author Date Editor Date
A. Diaz 1/17/12 S. Diaz 9/19/12
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 3 of 17
Page 4
Product at a
Safety Notes
•Always make sure that the voltage of the outlet to which you are connecting the
center.
Glance
Use on Dimmer
Outdoor Use
Sound Activated
DMX
Master/Slave
Please read the following Safety Notes carefully before working with the product. The
Notes include important safety information about installation, usage, and maintenance.
• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• Always disconnect the product from the power source before cleaning or replacing
the fuse.
• Avoid direct eye exposure to the light source while the product is on.
• Make sure the power cord is not crimped or damaged.
• Never disconnect the product from power cord by pulling or tugging on the cord.
• If mounting the product overhead, always secure to a fastening device using a
safety cable.
• Make sure there are no flammable materials close to the product when operating.
• Do not touch the product’s housing when operating because it may be very hot.
product is within the range stated on the decal or rear panel of the product.
•The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not
expose the product to rain or moisture.
•Always install the product in a location with adequate ventilation, at least 20 in (50
cm) from adjacent surfaces.
• Be sure that no ventilation slots on the product’s housing are blocked.
• Never connect the product to a dimmer.
• Make sure to replace the fuse with another of the same type and rating.
• Never carry the product from the power cord or any moving part. Always use the
hanging/mounting bracket or the handles.
•The maximum ambient temperature (Ta) is 104° F (40° C). Do not operate the
product at higher temperatures.
• In the event of a serious operating problem, stop using the product immediately.
• Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
Auto Programs
Auto-ranging Power Supply
Replaceable Fuse
User Serviceable
Duty Cycle
•Keep this User Manual for future use. If you sell the product to another user, be
sure that they also receive this document.
Pag e 4 of 17 COLORbar™ SMD User Manual (Rev. 2)
Page 5
2.INTRODUCTION
Product Overview
Microphone
Sound Sensitivity Knob
Bracket Adjustment Knob
3-pin DMX In
Fuse Holder
5-pin DMX In
Power In
LED Display
Safety Loop
5-pin DMX Out
Power Out
3-pin DMX Out
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 5 of 17
Page 6
Product Dimensions
Pag e 6 of 17 COLORbar™ SMD User Manual (Rev. 2)
Page 7
AC Power
ranging power supply and it can work with an input
(circuit breaker or fuse). Make
an appropriate electrical ground to avoid the risk of
a rheostat (variable resistor) or dimmer circuit, even
Fuse
Installed fuse
(held by plastic clip)
Spare fuse holder
(inside safety cap)
Safety cap
3.SETUP
The COLORbar™ SMD has an autovoltage range of 100~240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product’s back panel, or
refer to the product’s specifications chart. The listed current rating indicates the
product’s average current draw under normal conditions.
Always connect the product to a protected circuit
sure the product has
electrocution or fire.
Never connect the product to
if the rheostat or dimmer channel serves only as a 0% to 100% switch.
Replacement
Follow the instructions below to change the fuse, if necessary.
Disconnect the product from the power outlet before replacing the fuse.
1. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2. Pry the fuse holder out of the housing.
3. Remove the blown fuse from the holder and replace with a fuse of the exact same
type and rating.
4. Insert the fuse holder back in place and reconnect power.
The product does not ship with a spare fuse; however, the safety cap has room
for a spare.
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 7 of 17
Page 8
Power Linking
of the unit.
The power linking diagram shown above corresponds to the North American
in other markets, you must
consult with the local CHAUVET® distributor as power linking connectors and
1st Product
2nd Product
3rd Product
Other products
The product provides power linking via the IEC outlet located in the back
Please see the diagram below for further explanation.
Power Linking
Diagram
You can power link up to three (3) COLORbar™ SMD units @ 120 VAC or up to six
(6) COLORbar™ SMD units @ 230 VAC.
version of the product ONLY! If using the product
requirements may differ in your country or region.
Pag e 8 of 17 COLORbar™ SMD User Manual (Rev. 2)
Page 9
Mounting
, read and follow the safety recommendations indicated in
may be mounted in any position; however, make sure adequate
Rigging
can support
section of this manual for
Mount the
Mounting Bracket
Bra cket
Adjustment Knob
Text here
U Brackets (x 2)
Before mounting the product
the Safety Notes.
Orientation
Mounting Diagram
The COLORbar™ SMD
ventilation is provided around the product.
•Before deciding on a location for the product, al ways make sure there is easy
access to the product for maintenance and programming purposes.
•Make sure that the structure onto which you are mounting the product
the product’s weight. See the Technical Specifications
weight information.
•When mounting the product overhead, always use a safety cable.
product securely to a rigging point, whether an elevated platform or a truss.
•When rigging the product onto a truss, you should use a mounting clamp of
appropriate weight capacity. The bracket has a 13-mm hole, which is appropriate for
this purpose.
•When power linking multiple products, you must always consider the length of the
power linking cable and mount the products close enough for the cable to reach.
•The bracket adjustment knobs allow for directional adjustm ent when aiming the
product to the desired angle. Only loosen or tighten the bracket knobs manually.
Using tools could damage the knobs.
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 9 of 17
Page 10
Control Panel
four buttons located underneath the
on the control
Button
Function
<UP>
<DOWN>
Press to scroll down the list of options or to find a lower value
Menu Map
C4
C7
P3
P4
3-Color Fading
P6
Program Speed
S--
S001-S100
G000-G100
b000-b100
Blue
4.OPERATION
Operation
To access the control panel functions, use the
display. Please refer to the Product Overview to see the button locations
panel.
<MENU>
<ENTER> Press to activate a menu option or a selected value
Mode Programming Steps Description
Static Colors C--
Auto Programs P--
Custom Color
Mixing
Press to find an operation mode or to back out of the current menu
option
Press to scroll up the list of options or to find a higher value
C1 Red
C2 Green
C3 Blue
Cyan
C5 Magenta
C6 Yellow
White
P1 7-Color Switching
P2 7-Color Fading
3-Color Switching
P5 Chase program
Sound-Active Chase program
Selects auto program speed
R000-R100 Red
U--
Green
DMX
Personalities
Pag e 10 of 17 COLORbar™ SMD User Manual (Rev. 2)
3-CH
7-CH
24CH
d001-d512 Selects DMX starting address
Page 11
Configuration
channel mode for basic
channel DMX mode, which
the selected DMX mode uses. If you choose a starting address that is too high, you could
Set the product in DMX mode to control with a DMX controller.
(DMX)
1. Connect the product to a suitable power outlet.
2. Turn the product on.
3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input
socket on the product.
DMX
Personalities
and Starting
Address
The COLORbar™ SMD has three DMX personalities, from a 3control to a 24-channel mode with more advanced control over the lights.
The COLORbar™ SMD uses up to 24 DMX channels in its 24defines the highest configurable address to 489.
When selecting a starting DMX address, always consider the num ber of DMX channels
restrict the access to some of the product’s channels.
If you are not familiar with the DMX protocol, you may refer to the DMX Primer at
www.chauvetlighting.com.
To select the DMX personality, do the following:
1. Press <MENU> repeatedly until 3-CH, 7-CH, or 24CH shows on the display.
2. Press <ENTER> to choose your DMX personality when it appears on the display.
To then choose your starting address:
1. The display should show d 1 once you’ve selected your DMX personality using the
steps above.
2. Use <UP> or <DOWN> to select the starting address.
3. Press <ENTER>.
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 11 of 17
Page 12
DMX Channel Assignments and Values
1
Red
000 255
0~100%
2
Green
000 255
0~100%
3
Blue
000 255
0~100%
1
Red
000 255
0~100%
2
Green
000 255
0~100%
3
Blue
000 255
0~100%
000 255
No function
000 255
Col or Mac r os
Speed (slow to fast)
(when CH.6 is 026~225)
000 255
No function
000 255
0~30 Hz
000 025
No Func ti on
026 050
Fading 0~100%
051 075
Fading100%~0
076 100
Fading 100%~0~100%
101 125
Aut o prog ram P1
126 150
Aut o prog ram P2
151 175
Aut o prog ram P3
176 200
Aut o prog ram P4
201 225
Aut o prog ram P5
226 255
Sou nd-Active mode (Auto program P6)
7
Dimmer
000 255
0~100%
3-CH
7-CH
Channel Function Value Setting
Channel Function Value Setting
4 Color Macros
Speed 000 255
5
Strobe
6 Auto Programs
Pag e 12 of 17 COLORbar™ SMD User Manual (Rev. 2)
Page 13
1
Red
000 255
0~100%
2
Green
000 255
0~100%
3
Blue
000 255
0~100%
4
Red
000 255
0~100%
5
Green
000 255
0~100%
6
Blue
000 255
0~100%
7
Red
000 255
0~100%
8
Green
000 255
0~100%
9
Blue
000 255
0~100%
10
Red
000 255
0~100%
11
Green
000 255
0~100%
12
Blue
000 255
0~100%
13
Red
000 255
0~100%
14
Green
000 255
0~100%
15
Blue
000 255
0~100%
16
Red
000 255
0~100%
17
Green
000 255
0~100%
18
Blue
000 255
0~100%
19
Red
000 255
0~100%
20
Green
000 255
0~100%
21
Blue
000 255
0~100%
22
Red
000 255
0~100%
23
Green
000 255
0~100%
24
Blue
000 255
0~100%
24-CH
Channel Function Value Setting Section
1
2
3
4
5
6
7
8
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 13 of 17
Page 14
Configuration
the DMX
to adjust the duration of each step of the automatic program
Custom Static
Set the product in one of the standalone modes to control without a DMX controller.
(Standalone)
Static Color Mode
Automatic Mode
Color Mode
1. Connect the product to a suitable power outlet.
2. Turn the product on.
Never connect a product that is operating in any standalone mode (either Static,
Automatic, or Sound) to a DMX string connected to a DMX controller. Products in
standalone mode may transmit DMX signals that could interfere with
signals from the controller.
To enable the Static Color Mode, do the following:
1. Press <MENU> repeatedly until C-- shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to choose a color (C1-C7).
4. Press <ENTER>.
To enable the Automatic Mode, follow the instructions below:
1. Press <MENU> repeatedly until P-- shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to choose your auto program (P1-P7).
4. Press <ENTER>.
You can adjust the speed of the automatic program as well.
1. Press <MENU> repeatedly until S-- shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN>
from S001 (slow) to S100 (fast).
4. Press <ENTER>.
To enable the Custom Static Color Mode, follow the instructions below:
1. Press <MENU> repeatedly until U-- shows on the display.
2. Press <ENTER>.
3. Press <UP> or <DO WN> to choose between colors (R--, G--, b--).
4. Press <ENTER>.
5. Press <UP> or <DO WN> to choose the intensity of the color (000-100).
6. Repeat the steps to mix additional colors to create the color you need.
Pag e 14 of 17 COLORbar™ SMD User Manual (Rev. 2)
Page 15
Master/Slave
units (the “slaves”) without the need of a
Active mode, while the slave units will be set to operate in Slave Mode. Once set and
all the slave units before connecting the master unit to the DMX
Never connect a DMX controller to a DMX string configured for Master/Slave
may interfere with the signals from the
Product
To maintain optimum performance and
The Master/Slave mode allows a single COLORbar™ SMD unit (the “master”) to control
Mode
the actions of one or more COLORbar™ SMD
DMX controller. The master unit will be set to operate in either Automatic or Sound
connected, the slave units will operate in unison with the master unit.
Configure the units as indicated below.
Slave units:
1. Press <MODE> repeatedly until d 1 shows on the display.
2. Press <ENTER> to accept.
3. Set the DMX address to 001.
4. Connect the DMX input of the first slave unit to the DMX output of the master unit.
5. Connect the DMX input of the subsequent slave units to the DMX output of the
previous slave unit.
6. Finish setting and connecting all the slave units.
Master unit:
1. Set the master unit to operate in either Automatic or Sound mode.
2. Make the master unit the first unit in the DMX daisy chain.
• Configure
daisy chain.
•
operation because the controller
master unit.
• Do not connect more than 31 slave units to the master unit.
5.TECHNICAL INFORMATION
Dust build-up reduces light output performance and can cause overheating. This can
Maintenance
lead to reduction of the light source’s life.
minimize wear, you should clean your lighting products at least twice a month. However,
be aware that usage and environmental conditions could be contributing factors to
increase the cleaning frequency.
To clean the product, follow the instructions below:
• Unplug the product from power.
• Wait until the product is cold.
• Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on
the external surface/vents.
• Clean all transparent surfaces with a mild soap solution, ammonia-free glass
cleaner, or isopropyl alcohol.
• Apply the solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
• Softly wipe any dirt or grime to the outside edges of the transparent surface.
• Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
COLORbar™ SMD Us er Manual (Rev. 2) Pag e 15 of 17
Page 16
Dimensions and
Length
Width
Height
Weight
31.8 in (803 mm)
4.7 in (121 mm)
7 in (178 mm)
12 lbs (5.4 kg)
Note: Dimensions in inches rounded to the nearest decimal digit .
Power
Power Supply Type
Range
Voltage Selection
Switching (internal)
100~240 V, 50/60 Hz
Auto-ranging
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
300 W
292 W
Operating
2.3 A
1.3 A
Power linking current (units)
8 A (3 units)
8 A (6 units)
Fuse
F 5 A, 250 V
F 5 A, 250 V
Power I/O
US/Worldwide
UK/Europe
Power input connector
IEC
IEC
Power output c onnector
Edison
IEC
Power Cord plug
Edison (U S)
Local plug
Light Source
Type
Lifespan
SMD LED
50,000 hours
Color
Quantity
Current
Tri-color
648
20 mA x 3
Photo Optic
Parameter
Illuminance @ 2 m
328 lx
Str obe R ate
0~30 Hz
Beam angle
67º
Field angle
110°
Viewing angle
120°
Thermal
Maximum External Temp.
Cooling System
104° F (40° C)
Convection
DMX
I/O Connector s
Connector Type
Channel Range
3-pin and 5-pin XLR
Sockets
3, 7, 24
Ordering
Product Name
Item Code
Item Number
COLORbar™ SMD
03030478
COLORBARSMD
6.TECHNICAL SPECIFICATIONS
Weight
Pag e 16 of 17 COLORbar™ SMD User Manual (Rev. 2)
Page 17
Contact Us
Fax: +44 (0)1773 511110
Email: tech@chauvetlighting.com
www.chauvetlighting.com
www.chauvetlighting.co.uk
record and follow their instructions on how to return CHAUVET® products to
Returns
Tech Support office and request a Return
Merchandise Authorization (RMA) number before shipping the product. Be prepared to
provide the model number, serial number, and a brief description of the cause for the
, in its original box, and with its original packing
will refuse any product
number
the following information on a piece of paper
properly. Any shipping damage resulting from inadequate
reserves the right to use its own discretion to repair or replace
To return a product or request support:
• In the U.S., contact CHAUVET® World Headquarters (see below).
• In the UK or Ireland, contact CHAUVET® Europe Ltd. (see below).
• In any other country, DO NOT contact CHAUVET®. Instead, contact your distributor
of record. Refer to our website for contact details of distributors outside the U.S.,
United Kingdom, or Ireland.