Chauvet CLP-15 User Manual

Quick Reference Guide
Español ES
STRIKE™ 882 QRG EN
About this
The STRIKE™ 882 Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu options, and DMX values. Download the User Manual from www.chauvetpro.com for more details.

Disclaimer

The information and specifications contained in this QRG are subject to change without notice.

Safety Notes

DO NOT open this product. It contains no user-serviceable parts.
this product at higher temperatures.

Contact

Outside the U.S., United Kingdom, Ireland, or Mexi co, contact your distributor
for contact
information.

What is
Included

STRIKE™ 882

AC Power

This product has an auto-ranging power supply that can work with an input voltage range of 100~240 VAC, 50/60 Hz .

Power Linking

You can link up to 3 STRIKE™ 882 products at 120 V, 5 products at 208 V, or
linking cords can be
purchased separately.

AC Plug

Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow/Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Guide
DO NOT look at the light source when the product is on.
CAUTION: Flashing light is known to trigger epileptic seizures. User
must comply with local laws regarding notification of strobe use.
CAUTION: This product’s housing may be hot when lights are
operating.
Mount this product in a location with adequate ventilation, at least
20 in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product
while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT operate this product outdoors or in any location where dust,
excessive heat, water, or humidity may affect it.
DO NOT operate this product if the housing, lenses, or cables appear
damaged.
DO NOT connect this product to a dimmer or rheostat.
ONLY connect this product to a grounded and protected circuit.
ONLY use the hanging/mounting bracket to carry this product.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperat ure is 113 °F (45 °C). Do not operate
to request support or return a product. Visit www.chauvetpro.com
Neutrik® powerCON® power cord
6 products at 230 V. Never exceed this number. Power
2
Warranty Card
• Quick Reference Guide
EN STRIKE™ 882 QRG
Replacing the
1. Disconnect this product from power.
4. Screw the fuse hold er cap back in place and reconnect power.

DMX Linking

The STRIKE™ 882 will wo rk with a DM X controller usi ng a regular DM X serial connection. A DMX Primer is available from www.chauvetpro.com.

DMX Connection

The STRIKE™ 882 uses a regular DMX data connection for its DMX
. See the User M anual to conn ect
and configure for DMX operation.

Master/Slave
Connection

The STRIKE™ 882 uses the DM X dat a conn ecti on for it s Mast er/S lave mod e.

Mounting

Control Panel
Button
Function
<MENU>
Exits from the current menu or function
Enables the currently displayed menu or sets the currently selected value into the selected function
Navigates upwards through the menu list and increases the numeric value when in a function
Navigates downwards through the menu list and decreases the numeric value when in a function
Overhead Mounting
Floor Mounting
Clamp (Model #CLP-15)
Fuse
2. Using a Flat head screwdriver, unscrew the fuse hold er cap from the
housing.
3. Remove blown fuse and replace with a good fuse of the same type
and rating.
personalities: 1 Ch, 5 Ch, 6 Ch, and 10 Ch
See the User Manual to connect and configure for master/slave operation.
Product
Mounting
Diagram
Description
<ENTER>
<UP>
<DOWN>
3
STRIKE™ 882 QRG EN
Main Level
Programming Levels
Description
Auto
Auto 0–7
Speed 001–100
8 automatic programs
Dimmer
Sets the intensity of light output
Strobe
Selects the strobe frequency
On
10S
20S
30S
Auto
Test
Sets product in test mode
Version Vx.x
Shows the installed software version
Shows the total amount of time the product has been in us e
Address
001–512
Sets product’s DMX address
1 Ch
1-channel: strobe
5-channel: intensity, duration, rate, effect, macro
6 Ch
6-channel: Flash 1–6
10-channel: Flash 1–6, auto pr ograms, auto speed, dimmer, strobe
Master
Selects Master mode
Slave
Selects Slave mode
Temp xx° C
Displays product’s internal temperature

Menu Options

Static
BackLite
Info
FixHours
5 Ch
Channel
10 Ch
M&S Mode
000–255
Sets the amount of time the control panel backlight stays on
4
EN STRIKE™ 882 QRG

1 Ch

Channel
Function
Value
Percent/Setting
000 ó 005 006 ó 255
No function 0–100%

5 Ch

Channel
Function
Value
Percent/Setting
000 ó 005 006 ó 255
No function 0–100%
2
Flash Duration
000 ó 255
0–100%
000 ó 005 006 ó 255
No function 0–100%
000 ó 005
215 ó 255
No function
Spike effect
000 ó 005
215 ó 255
No function
Macro 6
To achieve blinder effects similar to a discharge strobe light, put

DMX Values

1 Strobe
1 Flash Intensity
3 Flash Rate
4 Special Effects
5
006 ó 042 043 ó 085 086 ó 128 129 ó 171 172 ó 214
006 ó 042
Pixel Control Macros
043 ó 085 086 ó 128 129 ó 171 172 ó 214
channels 1, 2, and 3 to full.
Ramp up Ramp down Ramp up – ram p down Random Lighting effect
Macro 1 Macro 2 Macro 3 Macro 4 Macro 5
5
STRIKE™ 882 QRG EN

6 Ch

Channel
Function
Value
Percent/Setting
000 ó 005 006 ó 255
No function Slow to fast
000 ó 005 006 ó 255
No function Slow to fast
000 ó 005 006 ó 255
No function Slow to fast
000 ó 005 006 ó 255
No function Slow to fast
000 ó 005 006 ó 255
No function Slow to fast
000 ó 005 006 ó 255
No function Slow to fast
Block 1
Block 2
Block 3
Block 4
Block 5
Block 6
DMX Values (cont.)
1 Block 1
2 Block 2
3 Block 3
4 Block 4
5 Block 5
6 Block 6
6
Loading...
+ 14 hidden pages