Power Connections 
The unit is supplied with a power plug appropriate to its voltage and destination. Should any 
other connections be required they must be carried out with the following configuration. 
Earth = Green/Yellow cable 
Neutral = Blue cable 
Live = Brown cable 
In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground 
connection. 
In the UK, it is required that all mains plugs are fitted with 5A fuses. 
Technical Specifications 
Power 
Power Protection  20mm Glass 1A Fast Blow  20mm Glass 0.5A Fast Blow 
Lamps 
Dimensions  241 x 127 x 127mm / 10in x 4.5in x 5.5in 
Weight  3.4kg / 7.5lbs 
115V~60Hz AC  230V~50Hz AC 
1 x 12V 50W 
Part No BRL 12V 50W 
1 x 12V 50W 
Part No BRL 12V 50W  
User Information (Please complete for your records) 
Date Purchased:   /  /  Serial No: _______________________ 
Dealer Stamp:      Model: CH-202B MINI MOON 
Mini Moon™ 
CH-202B 
Please read these instructions carefully before use 
Tel: +1-954-929-1115  Fax: +1-954-929-5560 
Users Guide 
World-wide Headquarters: 
3000 North 29th Ct. 
Hollywood, FL 33020 
www.ChauvetLighting.com 
CH-202B_UG.doc  1/14/2005 11:27:00 AM 
CH-202B_UG.doc  1/14/2005 11:27:00 AM 
 

At the Rear: 
 Mode Selector Switch  
 Screw Cap Fuseholder 
 Voltage Selector 
(Not on European Model) 
Lamp Replacement Cover 
Mounting Bracket 
Lens 
Fig. 1 
Introduction 
Congratulations on the purchase of your new CHAUVET lighting effect. We are confident you 
will enjoy many trouble free hours with this unit. To assist with the care and use of the product 
we have prepared this short guide. 
Operation 
Before connecting this unit to the mains power supply for the first time you must first install the 
lamps. (See ‘Replacing Lamps’ for details). 
This lighting effect has been designed to function on a mains power supply of either 
120V~60Hz or 230V~50Hz and has been fitted with a suitable power plug for use with your 
local voltage. Check the label and voltage selector switch (if fitted) on the unit and the power 
plug for the correct voltage. 
When connected to the mains power supply the unit should illuminate. This effect has three 
modes of operation – static, continuous rotation or sound activated. There is a selector switch 
at the rear which determines the mode (see fig.1). 
Your unit also comes supplied with four colored gels to suit your mood. Simply place the color 
gel over the lens and slip edges of gel into holder surrounding lens. There is an optional color 
wheel (CH-04) and selection of effects dishes available for this unit. 
Due to the high operating temperature of halogen lamps it is advisable that the effect be used 
in well ventilated areas taking care not to obstruct the air vents. After use allow time to ‘cool’ for  
safety and to ensure lamp life before moving or touching. 
The duty cycle for this effect should be no more than 15 minutes on then 15 minutes off. 
Installation / Mounting 
Although this unit can be used in an upright position, it is recommended that, for safety 
purposes, your lighting effect be properly mounted using a suitable hanging clamp and safety 
cable. CHAUVET offers a range of items, which are ideal for safe mounting. 
Use in a well-ventilated area without obstruction to air vents. 
Replacing Lamps 
1. Disconnect from main power supply before attempting to replace either lamps or fuse. 
2. Ensure that the unit is sufficiently cool, before removing blown lamps. 
3. Never touch new lamps with your fingers; use a tissue or a cloth. 
CH-202B_UG.doc  1/14/2005 11:27:00 AM 
In order to replace the lamp, disconnect from main power supply first, and unscrew the lamp 
replacement cover, which is highlighted on the diagram (fig.1). Only use the appropriately rated 
lamps as use of any other lamp type may cause the unit to be non-operational. 
Due to the nature of halogen lamps it is vitally important that you do not touch the new 
replacement lamp with your fingers, as this will reduce lamp life considerably. Once again a 
tissue or cloth can be used for fitting the replacement lamp. 
Finally before using, check that the lamp is housed correctly in the lamp holder and that the 
lamp replacement cover has been screwed back into place. 
If after replacement of the lamp, the unit is still not working then please contact CHAUVET for 
servicing. 
Replacing Fuses 
If the unit does not function at all when connected to the main power supply i.e. the fan does 
not rotate or the mechanism does not spin. Then it is highly likely that the fuse has blown. 
Disconnect from main power supply before attempting to replace either lamps or fuse. 
In order to replace the fuse, disconnect from the main power supply first, and then unscrew the 
fuseholder cover to reveal the fuse. The unit has a label attached which indicates the correct 
fuse rating and you will also find this listed as part of the specifications for the unit later in this 
guide. It is most important that replacement fuses are of the correct rating. Failure to use the 
correct fuse could damage the lighting effect beyond economic repair. 
The fuse should simply be placed inside the holder and the screw cap replaced, when this is 
done connect to the main power supply to check. If the unit is still not working then please 
contact CHAUVET for servicing. 
Cleaning 
The most important part of your lighting effect to keep clean is the lens as it allows the light 
output to transmit. This should be cleaned with a soft damp cloth. The body of the unit may also 
be cleaned in the same way. We recommend internal cleaning be carried out by a fully qualified 
technician. 
Maintenance & Servicing 
Work on internal parts should be carried out by a qualified technician. Removal of any covers 
other than the lamp replacement access or the fuse holder is considered a breach of warranty 
and will not be covered under any such agreement unless authorized first CHAUVET. 
Troubleshooting 
• If the unit is not functional – check main power supply is ‘on’ and check fuses. 
• If the unit is functional but lamp does not light - lamp may require replacing. 
• If the unit lights but will not move – check mode selector switch. 
If after trying this solution you still have a problem contact CHAUVET. 
Caution 
Do not obstruct the air vents. 
Do not touch unit or lamps while hot. 
No user serviceable parts inside, please refer to CHAUVET for service. 
CH-202B_UG.doc  1/14/2005 11:27:00 AM