The AmHaze Stadium User Manual includes a description, safety precautions, installation, programming,
operation and maintenance instructions for the AmHaze Stadium as of the release of this edition.
Trademarks
CHAUVET, the Chauvet logo and AmHaze Stadium are registered trademarks or trademarks of Chauvet &
Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company
and product names and logos referred to herein may be trademarks of their respective companies.
Copyright Notice
The works of authorship contained in this manual, including, but not limited to, all design, text and images
are owned by Chauvet.
Electronically published by Chauvet in the United States of America.
Manual Use
Chauvet authorizes its customers to download and print this manual for professional information purposes
only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this
manual or its content for any other purpose without written consent from Chauvet.
Document Printing
For best results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. If using A4
paper (210 x 297 mm), configure the printer to scale the content accordingly.
Intended Audience
Any person installing, operating, and/or maintaining this product should completely read through the guide
that shipped with the product, as well as this manual, before installing, operating, or maintaining this
product.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in all respects. However,
Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss,
damage or disruption caused by any errors or omissions in this document, whether such errors or
omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the
content of this document without any obligation to notify any person or company of such revision, however,
Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest
version from www.chauvetprofessional.com.
Document Revision
This AmHaze Stadium User Manual is the 3nd edition of this document. Go to
www.chauvetprofessional.com for the latest version.
AmHaze Stadium User Manual Rev. 3
Page 1 of 14
Page 4
BEFORE YOU BEGIN
!
!
2. BEFORE YOU BEGIN
What Is Included
•AmHaze Stadium
•Seetronic Powerkon IP65 power cord
Claims
Carefully unpack the product immediately and check the container to make sure all the parts are in the
package and are in good condition.
If the box or the contents (the product and included accessories) appear damaged from shipping, or show
signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier
immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed
damage, file a claim with Chauvet within 7 days of delivery.
Manual Conventions
ConventionMeaning
1–512A range of values
50/60A set of values of which only one can be chosen
<SET>A button on the product’s control panel
SettingsA product function or a menu option
Symbols
•Quick Reference Guide
SymbolMeaning
Electrical warning. Not following these instructions may cause electrical damage to
the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these
instructions may make the product not work, cause damage to the product, or cause
harm to the operator.
Important installation or configuration information. The product may not function
correctly if this information is not used.
Useful information.
Any reference to power connections in this manual assumes the use of Seetronic
IP rated cables.
The term “DMX” used throughout this manual refers to the USITT DMX512-A
digital data transmission protocol.
Page 2 of 14
AmHaze Stadium User Manual Rev. 3
Page 5
BEFORE YOU BEGIN
!
Safety Notes
Read all the following safety notes before working with this product. These notes contain important
information about the installation, usage, and maintenance of this product.
This product contains no user-serviceable parts. Any reference to servicing in this
User Manual will only apply to properly trained, certified technicians. Do not open
the housing or attempt any repairs.
All applicable local codes and regulations apply to proper installation of this
product.
Personal Safety
•Depending on the amount of haze generated, all haze machines may set off smoke detectors.
•Drain the tank before transporting the product.
•Always disconnect this product from its power source before servicing.
•The product’s nozzle is very hot during operation and it remains hot for a long time after operation
has stopped.
•Always connect this product to a grounded circuit to avoid the risk of electrocution.
•Do not drink or become in contact with the fluid. If you do, call your local emergency service (911 in
the US) for help.
•Do not use for space heating purposes.
•Do not touch this product’s housing during operation because it may be very hot.
Mounting and Rigging
•This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to
rain or moisture. (IP20)
•CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to
warm humid ballroom) condensation may form on the internal electronics of the product. To avoid
causing a failure, allow product to fully acclimate to the surrounding environment before connecting
it to power.
•Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent
surfaces.
•Make sure there are no flammable materials close to this product while it is operating.
•When hanging this product, always secure to a fastening device using a safety cable.
Power and Wiring
•Always make sure you are connecting this product to the proper voltage in accordance with the
specifications in this manual or on the product’s specification label.
•To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
•Never connect this product to a dimmer pack or rheostat.
•Never disconnect this product by pulling or tugging on the power cable.
Operation
•Do not operate this product if you see damage to the housing, fluid tank, or cables. Have the
damaged parts replaced by an authorized technician at once.
•Be sure that no ventilation slots on the product’s housing are blocked.
•Never carry the product from the power cord or any moving part. Always use the handles.
•The haze exits the nozzle at a very high temperature and it remains hot for a long time after
operation has stopped. Keep a minimum distance of 6.5 ft (2 m) from the nozzle to the nearest
object.
•The operating temperature is -22 °F to 113 °F (-30 °C to 45 °C). Do not operate this product outside
this temperature range.
•In the event of a serious operating problem, stop using this product immediately!
•Do not add perfume, alcohol, gasoline, or any other flammables to the fluid.
•Use only CHAUVET water-based Premium Haze Fluid (PHF) or Grignard Pure!
If your Chauvet product requires service, contact Chauvet Technical Support.
AmHaze Stadium User Manual Rev. 3
Page 3 of 14
Page 6
INTRODUCTION
Air Intake
Vent
Foot
Control
Panel
Nozzle
DMX Input
Fluid Tank
Fog Output
Mounting
Point
Handle
Fluid Hose
Fan Control
Volume
Control
DMX Output
Breaker
Power
3. INTRODUCTION
Description
The AmHaze Stadium is a water-based haze machine suited for large-scale applications. The AmHaze
Stadium is built specifically to function with a wide variety of water-based fluids and features a durable road
case for touring and production. The output and speed of haze can be easily adjusted via DMX or by the
manual knobs, and the unit comes equipped with an M12 threaded insert for hanging.
Features
•Professional water-based haze machine
•30-sec heat up time nearly eliminates wait time for operation
•Adjustable vent louver for directional haze flow
•Tour-ready with a rugged road case and M12 threaded rigging insert
•Efficient fluid consumption lasts up to 11 hours on a single fluid container
•Achieve continuous variable haze output and blower speed, adjusted via DMX or manual knobs
Product Overview
Page 4 of 14
AmHaze Stadium User Manual Rev. 3
Page 7
INTRODUCTION
20.61in
523.42mm
15.97in
405.67mm
10.82in
274.93mm
Product Dimensions
AmHaze Stadium User Manual Rev. 3
Page 5 of 14
Page 8
SETUP
!
4. SETUP
AC Power
Each AmHaze Stadium has a fixed power supply that works with an input voltage of either 120 VAC, 60 Hz
or 230 VAC, 50 Hz, depending on the specific model. To determine the power requirements for each
AmHaze Stadium, refer to the label affixed to the product. You can also refer to the Technical
Specifications chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, download Sizing Circuit Breakers from the Chauvet website: www.chauvetprofessional.com
•Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
•To eliminate unnecessary wear and improve its lifespan, during periods of nonuse completely disconnect the product from power via breaker or by unplugging
it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if
the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The AmHaze Stadium comes with a power input cord terminated with a Seetronic Powerkon IP65
connector on one end and an Edison plug on the other end (U.S. market). If the power input cord that
came with your product has no plug, or if you need the change the plug, use the table below to wire the
new plug.
ConnectionWire (U.S.)Wire (Europe)Screw Color
AC LiveBlackBrownYellow or Brass
AC NeutralWhiteBlueSilver
AC GroundGreen/YellowGreen/YellowGreen
.
Resetting the Breaker
This product is equipped with a resettable circuit breaker. If the breaker trips, all sections of this product will
lose power.
1.Remove the power cord from mains power.
2.Allow unit to cool for 15 minutes.
3.After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
4.Plug the product’s power cord into the power outlet and continue using as recommended.
DMX Linking
You can link the AmHaze Stadium to a DMX controller using a 3- or 5-pin DMX connection. If using other
DMX-compatible products with this product, you can control each individually with a single DMX controller.
DMX Personalities
The AmHaze Stadium uses a 3- or 5-pin DMX data connection for the 2-channel DMX personality.
•Refer to the Introduction for a brief description of each DMX personality.
•Refer to the Operation chapter to learn how to configure the AmHaze Stadium to work in these
personalities.
•The DMX Values section provides detailed information regarding the DMX personalities.
If you are not familiar with or need more information about DMX standards,
Master/Slave connectivity, or the DMX cables needed to link this product to a
DMX controller, download the DMX Primer from the Chauvet website:
www.chauvetprofessional.com
.
Page 6 of 14
AmHaze Stadium User Manual Rev. 3
Page 9
SETUP
Mounting Clamp
Safety Cable
Haze Knob
Fan Knob
Rubber Feet (x4) for
floor mounting
Threaded
Mounting Hole
Size M12
Mounting
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/
Orientation
Always mount this product in a safe position, making sure there is adequate room for ventilation,
configuration, and maintenance.
Rigging
Chauvet recommends using the following general guidelines when mounting this product.
•Before deciding on a location for the product, make sure there is easy access to the product for
maintenance and programming purposes.
•Make sure that the structure onto which you are mounting the product can support the product’s
weight. See the Technical Specifications
•When mounting the product overhead, always use a safety cable. Mount the product securely to a
rigging point, whether an elevated platform or a truss.
•When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
for weight information.
Procedure
The AmHaze Stadium includes 4 rubber feet for floor mounting and comes with a threaded mounting hole,
size M12, at the top of the hazer. This mounting hole is appropriate for use with a mounting clamp. You
must supply the mounting clamps. Make sure the clamps are capable of supporting the weight of this
product. Use at least one mounting point per product. For the CHAUVET Professional line of mounting
clamps, go to http://www.trusst.com/products.
Mounting Diagram
.
AmHaze Stadium User Manual Rev. 3
Page 7 of 14
Page 10
Preparing for Operation
!
To prepare the AmHaze Stadium for operation:
1.Open the flight case.
2.Pull out the fluid tank and remove the cap.
3.Verify that the two plastic hoses attached to the inside of the cap are in place and in good
condition.
4.Pour Chauvet (PHF) haze fluid or Grignard Pure inside the tank, and re-cap.
5.Reinsert the tank.
6.Make sure that the plastic hose that goes from the cap to the hazer is not bent.
7.Plug in power and wait approximately 30 seconds for warm-up to complete.
Only use Chauvet approved (PHF) haze fluid or Grignard Pure. Otherwise,
you might not have satisfactory results. In addition, unapproved fluid can
damage the AmHaze Stadium or cause harm to humans or animals. This
may void your warranty.
When storing the product, ALWAYS be sure to store the fluid tank with the
cap up, as seen on the storage diagram below before installing the front
cover to avoid tube damage that may cause leakage.
SETUP
Page 8 of 14
AmHaze Stadium User Manual Rev. 3
Page 11
OPERATION
5. OPERATION
Control Panel Operation
ButtonFunction
<FUNCTION> Exits from the current menu or function
<UP>
<DOWN>
<TIMER>Starts the timer controlled operation
<MANUAL>Manual haze output
<VOLUME
KNOB>
<FAN KNOB> Controls the fan speed, 1-100%
Control Options
Set the AmHaze Stadium starting address in the 001-512 DMX range. This enables control of up to 256
products in the 2-channel personality.
Programming
Refer to the Menu Map to understand the menu options. The menu map shows the main level and a
variable number of programming levels for each option.
•To go to the desired main level, press <FUNCTION> repeatedly until the option shows on the
display. This will take you to the first programming level for that option.
•To select an option or value within the current programming level, press <UP> or <DOWN> until
the option shows on the display. If there is another programming level, you will see that first option,
or you will see the selected value.
•Press <FUNCTION> repeatedly to exit to the previous main level.
Navigates upwards through the menu list and increases the numeric value when in a
function
Navigates downwards through the menu list and decreases the numeric value when in
a function
Controls the haze volume,1-100%
Menu Map
Main LevelProgramming LevelsDescription
Interval Set10-300 Seconds
Duration Set10-255 Seconds
DMX001-512
Sets the interval between haze
output
Sets the duration of the haze
output
Selects the DMX starting
address
AmHaze Stadium User Manual Rev. 3
Page 9 of 14
Page 12
OPERATION
Configuration (DMX)
Use DMX configurations to operate the product with a DMX controller.
DMX Control
In this mode, each product will respond to a unique starting address from the DMX controller. All products
with the same starting address will respond in unison.
1.Go to DMX Add. main level.
2.Select the starting address (001–512).
DMX Values
2 CH
ChannelFunctionValuePercent/Setting
000
1Fan Speed
2Haze Volume
005No function
006
255Fan speed (slow to fast)
000
005No function
006
255Haze volume 1-100%
Configuration (Standalone)
Use standalone configuration to operate the product without a DMX controller.
Interval
1.Go to Interval Set main level
2.Select the desired speed (10-300)
Duration
1.Go to the Duration Set main level
2.Select how long the haze flow will last (10-255)
Page 10 of 14
AmHaze Stadium User Manual Rev. 3
Page 13
TECHNICAL
6. TECHNICAL INFORMATION
Product Maintenance
Do not allow the haze machine to become clogged. After every 40 hours of continuous operation, use
CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter
in the heating element.
The recommended cleaning procedure is as follows.
1.Unplug the product from power.
2.Empty all fluid from the machine.
3.Add cleaning solution to the tank.
4.Connect the product to power and allow it to warm up.
5.Run the unit in a well-ventilated area until the tank is empty.
6.Refill with fluid to continue using the hazer. Run the machine briefly to clear any cleaning solution
from the pump and heater.
•FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET to clean
your AmHaze Stadium. Make sure you use FCQ regularly to increase the life of
your hazer.
•Do not spin the fans using compressed air because you could damage the
hazer.
•Test-run your AmHaze Stadium on a monthly basis to achieve the best
performance.
Storage
Before storing the hazer, run FCQ through the system as described in the cleaning procedure above;
however, only follow steps 1 through 5. Do not refill the tank with fluid if storing the hazer. Cleaning the
system prior to storage will help prevent any particles from condensing inside the pump or heater while not
in use.
AmHaze Stadium User Manual Rev. 3
Page 11 of 14
Page 14
TECHNICAL SPECIFICATIONS
7. TECHNICAL SPECIFICATIONS
Dimensions and Weight
LengthWidthHeightWeight
20.60 in (523.42 mm)10.80 in (274.9 mm)15.97 in (405.7 mm)38.4 lb (17.4 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply TypeRangeVoltage Selection
Model-specific
Parameter120 V, 60 Hz230 V, 50 Hz
Consumption1,230 W2,430 W
Operating Current10.25 A10.56 A
Breaker15 A, 250 V15 A, 250 V
Power I/OU.S./WorldwideUK/Europe
Power input connectorSeetronic Powerkon IP65Seetronic Powerkon IP65
Power Cord plugEdison (U.S.)Local Plug
120 VAC, 60 Hz or
230 VAC, 50 Hz
Fixed
Operation/Capacity/
Heat-up TimeTank CapacityFluid Consumption
30 sec1.3 gal (4.92 l)7.45 ml/min (0.12 gallons/hour)
Fan SpeedMaximum Run Time
157 CFM11 hours @ full volume
Consumption
Thermal
Startup TemperatureOperating TemperatureCooling System
-4 °F to 113 °F (-20 °C to 45 °C)-22 °F to 113 °F (-30 °C to 45 °C)Convection
DMX
I/O ConnectorChannel Range
3-or 5-pin XLR2
Ordering
Product NameItem CodeUPC Number
AmHaze StadiumAMHAZESTADIUM781462217181
AmHaze Stadium 230V230VAMHAZESTADIUM781462217341
Page 12 of 14
AmHaze Stadium User Manual Rev. 3
Page 15
RETURNS
RETURNS
Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will
not issue call tags.
Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product.
Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the
return.
To submit a service request online, go to www.chauvetprofessional.com/service-request
Clearly label the package with an RMA number. Chauvet will refuse any product returned without an RMA
number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number
directly on the box.
Once you have the RMA number, provide the following information on a piece of paper and place it inside
the box:
•Your name
•Your address
•Your phone number
•RMA number
•A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be
your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned
product(s).
Zona Industrial LermaWebsite: www.chauvetprofessional.mx
Voice: +52 (728) 690-2010
Email: FRtech@chauvetlighting.fr
Email: DEtech@chauvetlighting.de
Email: servicio@chauvet.com.mx
Visit the applicable website above to verify our contact information and instructions to request support.
Outside the U.S., U.K., Ireland, France, Germany, Mexico or Benelux, contact the dealer of record.
Page 14 of 14
AmHaze Stadium User Manual Rev. 3
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.