Chauvet Amhaze Stadium User Manual

Page 1
Model ID (120V): AMHAZESTADIUM
Model ID (230V): 230VAMHAZESTADIUM
User Manual
Page 2
TABLE OF CONTENTS
TABLE OF CONTENTS
Trademarks ................................................................................................... 1
Copyright Notice............................................................................................ 1
Manual Use .................................................................................................................... 1
Document Printing......................................................................................... 1
Intended Audience ........................................................................................ 1
Disclaimer ..................................................................................................... 1
Document Revision....................................................................................... 1
What Is Included ........................................................................................... 2
Claims ........................................................................................................... 2
Manual Conventions ..................................................................................... 2
Symbols ........................................................................................................ 2
Safety Notes.................................................................................................. 3
Personal Safety.............................................................................................................. 3
Mounting and Rigging .................................................................................................... 3
Power and Wiring........................................................................................................... 3
Operation ...................................................................................................... 3
Description .................................................................................................... 4
Features ......................................................................................................................... 4
Product Overview.......................................................................................... 4
Product Dimensions ...................................................................................... 5
AC Power...................................................................................................... 6
AC Plug .......................................................................................................................... 6
Resetting the Breaker ................................................................................... 6
DMX Linking.................................................................................................. 6
DMX Personalities.......................................................................................................... 6
Mounting ....................................................................................................... 7
Orientation...................................................................................................................... 7
Rigging ........................................................................................................................... 7
Procedure....................................................................................................................... 7
Preparing for Operation................................................................................. 8
Control Panel Operation................................................................................ 9
Control Options ............................................................................................. 9
Programming................................................................................................. 9
Menu Map ..................................................................................................... 9
Configuration (DMX) ..................................................................................... 10
DMX Control................................................................................................................... 10
DMX Values .................................................................................................. 10
Configuration (Standalone) ........................................................................... 10
Interval ........................................................................................................................... 10
Duration.......................................................................................................................... 10
6. Technical Information ........................................................................ 11
Product Maintenance .................................................................................... 11
Storage.......................................................................................................... 11
7. Technical Specifications.................................................................... 12
8. Returns ................................................................................................ 13
9. Contact Us........................................................................................... 14
TOC 1 of 1
AmHaze Stadium User Manual Rev. 3
Page 3
EDITION NOTES

1. EDITION NOTES

The AmHaze Stadium User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the AmHaze Stadium as of the release of this edition.

Trademarks

CHAUVET, the Chauvet logo and AmHaze Stadium are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.

Copyright Notice

The works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet.
© Copyright 2020 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America.

Manual Use

Chauvet authorizes its customers to download and print this manual for professional information purposes only. Chauvet expressly prohibits the usage, copy, storage, distribution, modification, or printing of this manual or its content for any other purpose without written consent from Chauvet.

Document Printing

For best results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. If using A4 paper (210 x 297 mm), configure the printer to scale the content accordingly.

Intended Audience

Any person installing, operating, and/or maintaining this product should completely read through the guide that shipped with the product, as well as this manual, before installing, operating, or maintaining this product.

Disclaimer

Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetprofessional.com.

Document Revision

This AmHaze Stadium User Manual is the 3nd edition of this document. Go to
www.chauvetprofessional.com for the latest version.
AmHaze Stadium User Manual Rev. 3
Page 1 of 14
Page 4
BEFORE YOU BEGIN
!
!

2. BEFORE YOU BEGIN

What Is Included

AmHaze Stadium
Seetronic Powerkon IP65 power cord

Claims

Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Manual Conventions

Convention Meaning
1–512 A range of values
50/60 A set of values of which only one can be chosen
<SET> A button on the product’s control panel
Settings A product function or a menu option

Symbols

Quick Reference Guide
Symbol Meaning
Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.
Any reference to power connections in this manual assumes the use of Seetronic IP rated cables.
The term “DMX” used throughout this manual refers to the USITT DMX512-A digital data transmission protocol.
Page 2 of 14
AmHaze Stadium User Manual Rev. 3
Page 5
BEFORE YOU BEGIN
!

Safety Notes

Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product.
This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs.
All applicable local codes and regulations apply to proper installation of this product.

Personal Safety

Depending on the amount of haze generated, all haze machines may set off smoke detectors.
Drain the tank before transporting the product.
Always disconnect this product from its power source before servicing.
The product’s nozzle is very hot during operation and it remains hot for a long time after operation has stopped.
Always connect this product to a grounded circuit to avoid the risk of electrocution.
Do not drink or become in contact with the fluid. If you do, call your local emergency service (911 in the US) for help.
Do not use for space heating purposes.
Do not touch this product’s housing during operation because it may be very hot.

Mounting and Rigging

This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. (IP20)
CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Make sure there are no flammable materials close to this product while it is operating.
When hanging this product, always secure to a fastening device using a safety cable.

Power and Wiring

Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
Never connect this product to a dimmer pack or rheostat.
Never disconnect this product by pulling or tugging on the power cable.

Operation

Do not operate this product if you see damage to the housing, fluid tank, or cables. Have the damaged parts replaced by an authorized technician at once.
Be sure that no ventilation slots on the product’s housing are blocked.
Never carry the product from the power cord or any moving part. Always use the handles.
The haze exits the nozzle at a very high temperature and it remains hot for a long time after operation has stopped. Keep a minimum distance of 6.5 ft (2 m) from the nozzle to the nearest object.
The operating temperature is -22 °F to 113 °F (-30 °C to 45 °C). Do not operate this product outside this temperature range.
In the event of a serious operating problem, stop using this product immediately!
Do not add perfume, alcohol, gasoline, or any other flammables to the fluid.
Use only CHAUVET water-based Premium Haze Fluid (PHF) or Grignard Pure!
If your Chauvet product requires service, contact Chauvet Technical Support.
AmHaze Stadium User Manual Rev. 3
Page 3 of 14
Page 6
INTRODUCTION
Air Intake
Vent
Foot
Control
Panel
Nozzle
DMX Input
Fluid Tank
Fog Output
Mounting
Point
Handle
Fluid Hose
Fan Control
Volume Control
DMX Output
Breaker
Power

3. INTRODUCTION

Description

The AmHaze Stadium is a water-based haze machine suited for large-scale applications. The AmHaze Stadium is built specifically to function with a wide variety of water-based fluids and features a durable road case for touring and production. The output and speed of haze can be easily adjusted via DMX or by the manual knobs, and the unit comes equipped with an M12 threaded insert for hanging.

Features

Professional water-based haze machine
30-sec heat up time nearly eliminates wait time for operation
Adjustable vent louver for directional haze flow
Tour-ready with a rugged road case and M12 threaded rigging insert
Efficient fluid consumption lasts up to 11 hours on a single fluid container
Achieve continuous variable haze output and blower speed, adjusted via DMX or manual knobs

Product Overview

Page 4 of 14
AmHaze Stadium User Manual Rev. 3
Page 7
INTRODUCTION
20.61in
523.42mm
15.97in
405.67mm
10.82in
274.93mm

Product Dimensions

AmHaze Stadium User Manual Rev. 3
Page 5 of 14
Page 8
SETUP
!

4. SETUP

AC Power

Each AmHaze Stadium has a fixed power supply that works with an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model. To determine the power requirements for each AmHaze Stadium, refer to the label affixed to the product. You can also refer to the Technical Specifications chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more information, download Sizing Circuit Breakers from the Chauvet website: www.chauvetprofessional.com
Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non­use completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

AC Plug

The AmHaze Stadium comes with a power input cord terminated with a Seetronic Powerkon IP65 connector on one end and an Edison plug on the other end (U.S. market). If the power input cord that came with your product has no plug, or if you need the change the plug, use the table below to wire the new plug.
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow or Brass AC Neutral White Blue Silver AC Ground Green/Yellow Green/Yellow Green
.

Resetting the Breaker

This product is equipped with a resettable circuit breaker. If the breaker trips, all sections of this product will lose power.
1. Remove the power cord from mains power.
2. Allow unit to cool for 15 minutes.
3. After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
4. Plug the product’s power cord into the power outlet and continue using as recommended.

DMX Linking

You can link the AmHaze Stadium to a DMX controller using a 3- or 5-pin DMX connection. If using other DMX-compatible products with this product, you can control each individually with a single DMX controller.

DMX Personalities

The AmHaze Stadium uses a 3- or 5-pin DMX data connection for the 2-channel DMX personality.
Refer to the Introduction for a brief description of each DMX personality.
Refer to the Operation chapter to learn how to configure the AmHaze Stadium to work in these personalities.
The DMX Values section provides detailed information regarding the DMX personalities.
If you are not familiar with or need more information about DMX standards, Master/Slave connectivity, or the DMX cables needed to link this product to a DMX controller, download the DMX Primer from the Chauvet website:
www.chauvetprofessional.com
.
Page 6 of 14
AmHaze Stadium User Manual Rev. 3
Page 9
SETUP
Mounting Clamp
Safety Cable
Haze Knob
Fan Knob
Rubber Feet (x4) for
floor mounting
Threaded
Mounting Hole
Size M12

Mounting

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products/

Orientation

Always mount this product in a safe position, making sure there is adequate room for ventilation, configuration, and maintenance.

Rigging

Chauvet recommends using the following general guidelines when mounting this product.
Before deciding on a location for the product, make sure there is easy access to the product for maintenance and programming purposes.
Make sure that the structure onto which you are mounting the product can support the product’s weight. See the Technical Specifications
When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, whether an elevated platform or a truss.
When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
for weight information.

Procedure

The AmHaze Stadium includes 4 rubber feet for floor mounting and comes with a threaded mounting hole, size M12, at the top of the hazer. This mounting hole is appropriate for use with a mounting clamp. You must supply the mounting clamps. Make sure the clamps are capable of supporting the weight of this product. Use at least one mounting point per product. For the CHAUVET Professional line of mounting clamps, go to http://www.trusst.com/products.
Mounting Diagram
.
AmHaze Stadium User Manual Rev. 3
Page 7 of 14
Page 10

Preparing for Operation

!
To prepare the AmHaze Stadium for operation:
1. Open the flight case.
2. Pull out the fluid tank and remove the cap.
3. Verify that the two plastic hoses attached to the inside of the cap are in place and in good
condition.
4. Pour Chauvet (PHF) haze fluid or Grignard Pure inside the tank, and re-cap.
5. Reinsert the tank.
6. Make sure that the plastic hose that goes from the cap to the hazer is not bent.
7. Plug in power and wait approximately 30 seconds for warm-up to complete.
Only use Chauvet approved (PHF) haze fluid or Grignard Pure. Otherwise, you might not have satisfactory results. In addition, unapproved fluid can damage the AmHaze Stadium or cause harm to humans or animals. This may void your warranty.
When storing the product, ALWAYS be sure to store the fluid tank with the cap up, as seen on the storage diagram below before installing the front cover to avoid tube damage that may cause leakage.
SETUP
Page 8 of 14
AmHaze Stadium User Manual Rev. 3
Page 11
OPERATION

5. OPERATION

Control Panel Operation

Button Function
<FUNCTION> Exits from the current menu or function
<UP>
<DOWN>
<TIMER> Starts the timer controlled operation
<MANUAL> Manual haze output
<VOLUME
KNOB>
<FAN KNOB> Controls the fan speed, 1-100%

Control Options

Set the AmHaze Stadium starting address in the 001-512 DMX range. This enables control of up to 256 products in the 2-channel personality.

Programming

Refer to the Menu Map to understand the menu options. The menu map shows the main level and a variable number of programming levels for each option.
To go to the desired main level, press <FUNCTION> repeatedly until the option shows on the display. This will take you to the first programming level for that option.
To select an option or value within the current programming level, press <UP> or <DOWN> until the option shows on the display. If there is another programming level, you will see that first option, or you will see the selected value.
Press <FUNCTION> repeatedly to exit to the previous main level.
Navigates upwards through the menu list and increases the numeric value when in a function
Navigates downwards through the menu list and decreases the numeric value when in a function
Controls the haze volume,1-100%

Menu Map

Main Level Programming Levels Description
Interval Set 10-300 Seconds
Duration Set 10-255 Seconds
DMX 001-512
Sets the interval between haze output
Sets the duration of the haze output
Selects the DMX starting address
AmHaze Stadium User Manual Rev. 3
Page 9 of 14
Page 12
OPERATION

Configuration (DMX)

Use DMX configurations to operate the product with a DMX controller.

DMX Control

In this mode, each product will respond to a unique starting address from the DMX controller. All products with the same starting address will respond in unison.
1. Go to DMX Add. main level.
2. Select the starting address (001–512).

DMX Values

2 CH
Channel Function Value Percent/Setting
000
1Fan Speed
2 Haze Volume
005 No function
006
255 Fan speed (slow to fast)
000
005 No function
006
255 Haze volume 1-100%

Configuration (Standalone)

Use standalone configuration to operate the product without a DMX controller.

Interval

1. Go to Interval Set main level
2. Select the desired speed (10-300)

Duration

1. Go to the Duration Set main level
2. Select how long the haze flow will last (10-255)
Page 10 of 14
AmHaze Stadium User Manual Rev. 3
Page 13
TECHNICAL

6. TECHNICAL INFORMATION

Product Maintenance

Do not allow the haze machine to become clogged. After every 40 hours of continuous operation, use CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent the accumulation of particulate matter in the heating element. The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-ventilated area until the tank is empty.
6. Refill with fluid to continue using the hazer. Run the machine briefly to clear any cleaning solution
from the pump and heater.
FCQ (Fog Cleaner Quart) was specifically developed by CHAUVET to clean your AmHaze Stadium. Make sure you use FCQ regularly to increase the life of your hazer.
Do not spin the fans using compressed air because you could damage the hazer.
Test-run your AmHaze Stadium on a monthly basis to achieve the best performance.

Storage

Before storing the hazer, run FCQ through the system as described in the cleaning procedure above; however, only follow steps 1 through 5. Do not refill the tank with fluid if storing the hazer. Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or heater while not in use.
AmHaze Stadium User Manual Rev. 3
Page 11 of 14
Page 14
TECHNICAL SPECIFICATIONS

7. TECHNICAL SPECIFICATIONS

Dimensions and Weight
Length Width Height Weight
20.60 in (523.42 mm) 10.80 in (274.9 mm) 15.97 in (405.7 mm) 38.4 lb (17.4 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type Range Voltage Selection
Model-specific
Parameter 120 V, 60 Hz 230 V, 50 Hz
Consumption 1,230 W 2,430 W
Operating Current 10.25 A 10.56 A
Breaker 15 A, 250 V 15 A, 250 V
Power I/O U.S./Worldwide UK/Europe
Power input connector Seetronic Powerkon IP65 Seetronic Powerkon IP65
Power Cord plug Edison (U.S.) Local Plug
120 VAC, 60 Hz or
230 VAC, 50 Hz
Fixed
Operation/Capacity/
Heat-up Time Tank Capacity Fluid Consumption
30 sec 1.3 gal (4.92 l) 7.45 ml/min (0.12 gallons/hour)
Fan Speed Maximum Run Time
157 CFM 11 hours @ full volume
Consumption
Thermal
Startup Temperature Operating Temperature Cooling System
-4 °F to 113 °F (-20 °C to 45 °C) -22 °F to 113 °F (-30 °C to 45 °C) Convection
DMX
I/O Connector Channel Range
3-or 5-pin XLR 2
Ordering
Product Name Item Code UPC Number
AmHaze Stadium AMHAZESTADIUM 781462217181
AmHaze Stadium 230V 230VAMHAZESTADIUM 781462217341
Page 12 of 14
AmHaze Stadium User Manual Rev. 3
Page 15

RETURNS

RETURNS
Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags.
Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return.
To submit a service request online, go to www.chauvetprofessional.com/service-request Clearly label the package with an RMA number. Chauvet will refuse any product returned without an RMA
number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Once you have the RMA number, provide the following information on a piece of paper and place it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned product(s).
.
AmHaze Stadium User Manual Rev. 3
Page 13 of 14
Page 16

CONTACT US

General Information Technical Support
Chauvet World Headquarters
Chauvet Europe Ltd
Chauvet Europe BVBA
Chauvet France
Chauvet Germany
Chauvet Mexico
Address: Av. de las Partidas 34 - 3B
Lerma, Edo. de México, CP 52000
CONTACT US
Address: 5200 NW 108th Ave. Voice: (844) 393-7575
Sunrise, FL 33351 Fax: (954) 756-8015
Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084 Website: www.chauvetprofessional.com
Address: Unit 1C Email: UKtech@chauvetlighting.eu
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetprofessional.eu
NG16 6NT
Voice: +4 4 ( 0 ) 1773 511115
Fax : + 4 4 ( 0) 1773 511110
Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
9770 Kruishoutem
Belgium Website: www.chauvetprofessional.eu
Voice: +32 9 388 93 97
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France Website: www.chauvetprofessional.eu
Voice: +33 1 78 85 33 59
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Germany Website: www.chauvetprofessional.eu
Voice: +49 421 62 60 20
(Entrance by Calle 2)
Zona Industrial Lerma Website: www.chauvetprofessional.mx
Voice: +52 (728) 690-2010
Email: FRtech@chauvetlighting.fr
Email: DEtech@chauvetlighting.de
Email: servicio@chauvet.com.mx
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U.K., Ireland, France, Germany, Mexico or Benelux, contact the dealer of record.
Page 14 of 14
AmHaze Stadium User Manual Rev. 3
Loading...