Chauvet 86 User Manual

Snapshot
Use on Dimmer
Outdoor Use
Sound Activated
DMX
Master/Slave
Auto-ranging
Power Supply
Replaceable Fuse
User Serviceable
Duty Cycle
User Manual
3000 N 29th Ct, Hollywood, FL 33020 U.S.A.
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
CHAUVET®, 2009, All Rights Reserved Information and specifications in this User Manual are subject to change without notice. CHAUVET® assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.
TABLE OF CONTENTS
1. BEFORE YOU BEGIN ................................................................................................................................................... 3
WHAT IS INCLUDED ................................................................................................................................................................................ 3
UNPACKING INSTRUCTIONS .................................................................................................................................................................... 3
MANUAL CONVENTIONS ......................................................................................................................................................................... 3
ICONS .................................................................................................................................................................................................. 3
SAFETY INSTRUCTIONS .......................................................................................................................................................................... 4
2. INTRODUCTION ........................................................................................................................................................... 5
FEATURES ............................................................................................................................................................................................ 5
PRODUCT OVERVIEW............................................................................................................................................................................. 5
3. SETUP .......................................................................................................................................................................... 6
AC POWER........................................................................................................................................................................................... 6
Power Linking ........................................................................................................................................................... 6
MOUNTING............................................................................................................................................................................................ 7
Orientation ................................................................................................................................................................ 7
Rigging ..................................................................................................................................................................... 7
4. OPERATING INSTRUCTIONS ...................................................................................................................................... 8
CONFIGURING THE STARTING ADDRESS .................................................................................................................................................. 8
DMX OPERATION.................................................................................................................................................................................. 8
MASTER/SLAVE MODE (AUTO MODE, STATIC) ......................................................................................................................................... 8
STANDALONE OPERATION ...................................................................................................................................................................... 8
Automatic .................................................................................................................................................................. 8
Sound-Active ............................................................................................................................................................ 9
Static ........................................................................................................................................................................ 9
Fixture Linking .......................................................................................................................................................... 9
DMX CHANNEL VALUES ........................................................................................................................................................................ 9
5. APPENDIX .................................................................................................................................................................. 10
DMX PRIMER ..................................................................................................................................................................................... 10
GENERAL MAINTENANCE...................................................................................................................................................................... 10
DATA CABLING .................................................................................................................................................................................... 11
DMX Data Cable ..................................................................................................................................................... 11
Cable Connectors ................................................................................................................................................... 11
FIXTURE LINKING................................................................................................................................................................................. 11
3-PIN TO 5-PIN CONVERSION CHART .................................................................................................................................................... 12
SETTING UP A DMX SERIAL DATA LINK ................................................................................................................................................. 12
SETTING THE STARTING ADDRESS ........................................................................................................................................................ 13
GENERAL TROUBLESHOOTING .............................................................................................................................................................. 13
CONTACT US ...................................................................................................................................................................................... 13
RETURNS PROCEDURE ........................................................................................................................................................................ 14
CLAIMS .............................................................................................................................................................................................. 14
TECHNICAL SPECIFICATIONS ................................................................................................................................................................ 15
1. BEFORE YOU BEGIN
CONVENTION
MEANING
[10]
A DIP switch to be configured
<Menu>
A key to be pressed on the fixture’s control panel
1~512
A range of values
50/60
A set of values of which only one can be chosen
Settings
A menu option not to be modified (for example, showing the operating mode/current status)
MENU > Settings
A sequence of menu options to be followed
ON
A value to be entered or selected
ICONS
MEANING
This paragraph contains critical installation, configuration or operation information. Failure to comply with this information may render the fixture partially or completely inoperative, cause damage to the fixture or cause harm to the user.
This paragraph contains important installation or configuration information. Failure to comply with this information may prevent the fixture from functioning correctly.
This paragraph reminds you of useful, although not critical, information.
What is included
1 x DIAMONDsplash86 1 x Warranty Card 1 x User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Manual Conventions
CHAUVET® manuals use the following conventions to differentiate certain types of information from the regular text.
Icons
This manual uses the following icons to indicate information that requires special attention on the part of the user.
1. Before You Begin 3 1/6/2010 10:35 AM
Safety Instructions
Please read these instructions carefully. It includes important information about the installation, usage and maintenance of this product.
Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that
they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
This product is intended for indoor use only! To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable materials close to the unit while operating. The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent
surfaces. Be sure that no ventilation slots are blocked. Always disconnect from power source before servicing or replacing fuse and be sure to replace with
same fuse source. Secure fixture to fastening device using a safety chain. Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher
than this. In the event of a serious operating problem, stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Never connect the device to a dimmer pack. Make sure the power cord is never crimped or damaged. Never disconnect the power cord by pulling or tugging on the cord. Never carry the fixture directly from the cord. Always use the hanging/mounting bracket. Avoid direct eye exposure to the light source while it is on.
1. Before You Begin 4 1/6/2010 10:35 AM
2. INTRODUCTION
Microphone Sensitivity Adjustment Knob
Power In
Microphone
DMX In
DIP Switches
Power Out
DMX Out
Fuseholder
Features
2-channel DMX-512 white narrow beam LED wash Blackout/static/dimmer/strobe/pulse Static color, strobing and pulse effects with or without DMX controller
Additional Features
Additional power output: max 37 units Built-in automated programs via master/slave Built-in sound activated programs via master/slave
Product Overview
2. Introduction 5 1/6/2010 10:35 AM