LED Foll owspot 75 QRG 
The LED Foll owspot 75 Quick Reference Guide (QRG) only contains the 
’s connection and mounting information as well as the menu options 
Please read the following notes carefully before s tarti ng to wor k with this 
• Always connect this product to a grounded circuit to avoid the risk of 
• Always make sure tha t t he voltage of the ou t let t o w hich you a re 
can lead to damage or malfunction. Please contact the nearest authorized 
Guide
Disclaimer
Safety Notes 
product 
and the DMX values. 
• This Quick Reference Guide DOE S NOT re place t he prod uct’ s user 
manual, which you can download from the CHAUVET® website 
(www.chauvetlighting.com). 
• Read ALL the disclaimers and safety notes in this document as well as 
those in the product ’s user manual before installing, operating, or 
maintaining this product. 
product. They include important safety information about its 
usage, and maintenance. 
electrocution. 
• Always discon nect t his product from the pow er sou rce before cleaning it 
or replacing the fuse. 
• Avoi d direct eye exposure to the light source while t he fixture i s on. 
• Make sure t he power cord is not c rimped or dama ged. 
• Make sure th ere are no flammable mate rials close to the unit while 
operating. 
• Do not touch this product’s housing when operating because it may be 
connecting this product is within the range stated on the decal or rear 
panel of the fixture. 
• Thi s produ ct is for ind oor us e only! (IP20) To preve nt risk of fire or 
shock, d o not ex pose this fi xture to rain or m oi sture. 
• Never connect this product to a dimmer pack. 
• Make sure to replace the fuse wit h another of the same type and rating. 
• Never carry this product from the power cord or any moving part. 
Always use the hanging/mounting bracket or the handles. 
• The maximum ambient temperature (Ta) is 104° F (40° C). Do not 
operate this pr oduct at h igher tem peratures. 
• In the event of a serious operating problem, stop using the unit 
immediately. 
• Never try to repair this product. Repairs carried out by unskilled people 
technical ass istanc e center. 
• Power Cor d 
• Quick Reference Guide 
Page 2 of 8 

LED Foll owspot 75 QRG 
The LED Followspot 75 is a portable, LED-powered product tha t offers 
smooth LED 
dimming and an extremely fast electronic strobe makes it a fantastic beam 
Focus Lens Adjustment Knobs 
DMX or manual controls to suit a variety of needs. Super-
Description
Product Overview
for any performance. 
Page 3 of 8 

LED Foll owspot 75 QRG 
This product has a switchable power supply that can work with an input 
1. Disconnect this product from power. 
Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from 
5. Screw the fuse holder cap back in place and reconnect power. 
The LED F ollow spot 75 can work with a DMX controller when linked using 
The LED Followspot 75 uses a regular DMX data connection for its  
chapter to learn how to connect this fixture for DMX operation, and the 
chapter to learn in detail how to configure this fixture 
The LED Fol l ow sp ot 7 5 uses the DMX data connection for i ts Mast er /S la ve 
chapter to learn in detail how to configure this fixture for 
volt age of 1 15 VAC or 230 VA C , 50/60 Hz. 
Replacement
2. 
the housing. 
3. Remove th e blown fuse. 
4. Replace with a good fuse of the same type and rating. 
a regu lar DMX s erial connection .  
If you are not familiar DMX, download the DMX P rimer 
www.chauvetlighting.com. 
3-channel DMX personality.  
Download the LED Followspot 75 user manual and refer to the Setup
Operation Instruc tions 
for DMX ope r ation. 
mode.  
Download the LED Followspot 75 user manual and refer to the Setup
chap ter to l ear n how to c onne ct t his fi xtur e for Mas ter /S lave oper ati on, and  
the Operation 
Master/Slave operation. 
Page 4 of 8 

Before mounting this product, read the safety notes at the beginning of this 
guide and in the product’s user manual. 
Bracket Adju stment 
Knob (x2) 
Diagram
LED Foll owspot 75 QRG 
Page 5 of 8 

LED Foll owspot 75 QRG 
For d e tails on h ow to program this prod uct, please refer to t he pr oduct’s user 
Turns LED on (default setting) 
Selects Manual or DMX Mode 
In DMX M od e, moves channel number up 
In DMX Mode, moves channel number down 
To ensure full access to all channels in each DMX mode, the highest 
manual. 
Button  Function 
Description
<DIMMER MAX> 
<DIMMER MIN> 
recommended DMX address is 510. 
Opens dimmer to a maximum of 100% (h old to 
Cl oses dimm er to a max im um of 0% (hold to 
Page 6 of 8 

LED Foll owspot 75 QRG 
Sets the DMX starting address 
Menu Options 
Main Level  Programming Levels  Description 
DMX Values 
Channel 
2 
  Value  Percent/Setting 
Page 7 of 8 

LED Foll owspot 75 QRG 
United Kingdom and Ireland 
    www.chauvetlighting.co.uk  
Outside the U.S., United Kingdom, or Ireland, contact your distributor. 
CHAUVET® 
General Inform ation 
Address:  5200 NW 108th Avenue 
  Sunrise, FL 33351 
Voice:  (954) 929-1115 
Fax:  (954) 929-5560 
Toll free:  (800) 762-1084 
CHAUVET® Europe Lt d. 
General Inform ation 
Address:  Unit 1C 
  Brookhill Road Industrial Estate 
  Pinxton, Nottingham, UK 
  NG16 6NT 
Voice:  +44 (0)1773 511115
Voice:  (954) 929-1115 (Press 4)  
Fax:  (954) 756-8015 
Email:  tech@chauvetlighting.com 
Email:  uktech@chauvetlighting.com  
Foll ow t hei r inst r ucti ons to req ues t sup por t or t o ret urn a prod uct. Vis it our 
website for contact details. 
LED Followspot 75 QRG – Rev. 3 
© Copyrigh t 2012 CHAUVET® 
All rights reserved 
Printed in the P. R. C.
Page 8 of 8