PRODUCT APPLICATION
Electronic Locking System For CPI Cabinets
Electronic Locking System
Automate access control and monitoring in your data center, computer
room and network facilities with the Electronic Locking System.
• Automate data center cabinet access control and monitoring
• IP addressable system increases security
• Assign and program individual user ID access codes
• Access cabinets via a network-connected computer, keypad or
proximity cards
• Create a log entry for each access attempt and configuration change
• Monitor handle conditions — opened or closed
• Forward SNMP traps to designated computers during alarm conditions
• Quickly update the system configuration and users privileges
• Easily add modules as your network grows
Communications Module (required) — Provides a single IP
addressable network connection for the Electronic Locking
System and is used to setup and configure the system.
Each Communications Module can support any
combination of up to 64 Electronic Lock Control
Modules (512 handles, 256 cabinets), 64 Keypad
Modules and 64 Proximity Card Reader Modules. Control
access to equipment with computer terminals using the
included lock control software. Provide alarm outputs for
unauthorized entries. The software also keeps a log of
each access attempt and all configuration changes.
Electronic Lock Upgrade Kit (required)
— Replace the mechanical lock on the
cabinet’s swing handle with an electronic
solenoid that releases the spring-loaded
handle when the correct code is entered.
When the correct code is entered, the
handle springs open allowing the door to
be opened.
Electronic Lock Control Module (required) —
Connects upgraded electronic locks to the
Electronic Locking System and controls the
solenoid that opens the cabinet handles.
Each Electronic Lock Control Module
connects eight handles (four cabinets) to
the system. Each handle can have up to
five access codes and can be assigned to
24 user groups. The Electronic Lock Control
Module also reports the status of the handle
(opened or closed).
Communications Module
Electronic Lock Upgrade Kit (2 per cabinet)
with Electronic Lock Extension Cable
Electronic Lock Control Module (8 handle)
Keypad Module
with Keypad Module Cable
Proximity Card Reader Module
Rear
View
Keypad Module (recommended) — Enter an
authorized access code on the Keypad Module to
open a handle. The Keypad Module can be placed
on or near the cabinets and can open any of the
cabinet handles in the system.
Proximity Card Reader Module (optional) — Use with the
Keypad Module. The proximity card acts like a key replacing the
access code. The proximity card can be programmed with a
specific handle access code or with up to 24 user group codes to
open multiple cabinets. Proximity cards can also be programmed
to open handles a specific number of times and to expire at a
specific time and date.
800-834-4969
techsupport@chatsworth.com
www.chatsworth.com
P R O D U C T A P P L I C AT I O N S H E E T
S O L U T I O N O V E R V I E W :
• User specific accounts - assign each authorized user access to specific cabinets with an individual access code or proximity card
• Records each access attempt - the lock control software keeps a log with records of each access attempt and each configuration change
• Quick changes to access permissions - software allows the system administrator to add or remove authorized users and change access codes and
permissions quickly
• Create multiple user groups - the system administrator can associate users and latches by a group number to restrict access by service group, authorization
level, facility or region with the lock control software
• Remote access control over the network - the lock control software lets authorized users see the status of all latches and open door latches remotely
• Generates alarm outputs for unauthorized entries - the Communications Module has two alarm relay outputs that can be used to send SNMP traps to
designated computers, operate external devices or to connect to the CPI Remote Infrastructure Management (RIM-600) System to notify you if there is an
unauthorized entry
• Grows with your network - simply add modules as your network grows; a single network connection provides access to 256 cabinets (512 swing handles)
• Connect the Communications, Electronic Lock Control and Proximity Card Reader Modules with RJ-45 patch cords; connect Keypad Modules with Keypad
Module Cables; connect Electronic Lock Upgrade Kits and Electronic Lock Control Modules with Electronic Lock Extension Cables
O R D E R I N G I N F O R M A T I O N
Part Number Description
16147-050 Communications Module
16147-010
16147-060
16147-061
16147-062
16147-063
16147-052 Electronic Lock Control Module for 8 Swing Handles 5 lb (2.3 kg)
16147-008 Keypad Module with (1) Keypad Module Cable 1 lb (0.5 kg)
16147-054 Proximity Card Reader Module 5 lb (2.3 kg)
60070-007 Network Patch Cord, RJ-45, 7’L (2.1 m) 1 lb (0.5 kg)
60070-014 Network Patch Cord, RJ-45, 14’L (4.3 m) 1 lb (0.5 kg)
60070-025 Network Patch Cord, RJ-45, 25’L (7.6 m) 1 lb (0.5 kg)
16147-015 Electronic Lock Extension Cable, 16’L (5 m) 1 lb (0.5 kg)
Electronic Lock Upgrade Kit for Enhanced SteelFrame Cabinet
for the Front or Rear Door (1/Door)
Electronic Lock Upgrade Kit for TeraFrame™Cabinet System
with a Single Solid or Perforated Front Door (1/Door)
Electronic Lock Upgrade Kit for TeraFrame Cabinet System with
a Single Solid Plexiglass Front Door (1/Door)
Electronic Lock Upgrade Kit with Integrated Keypad Module
for a TeraFrame Cabinet with a Single Solid or
Perforated Front Door (1/Door)
Electronic Lock Upgrade Kit for TeraFrame Cabinet System with
a Single or Double Solid or Perforated Rear Door (1/Door)
Shipping Weight
5 lb (2.3 kg)
1 lb (0.5 kg)
3 lb (1.4 kg)
3 lb (1.4 kg)
4 lb (1.8 kg)
2 lb (0.9 kg)
16147-050
16147-060
16147-052
16147-062
16147-016 Keypad Module Cable, 9’L (2.7 m) 1 lb (0.5 kg)
Note: Contact CPI Technical Support to configure TeraFrame Cabinets with electronic locks.
R E C O M M E N D E D A C C E S S O R I E S :
Part Number Description Shipping Weight
60000-001
60052-002 Door Open/Closed Sensor 1 lb (0.5 kg)
60065-001 Axis®Network Camera 1 lb (0.5 kg)
60050-001 Dry Contact Bridge (NO/NC) 1 lb (0.5 kg)
60061-007 Motion Sensor, Passive Infrared 1 lb (0.5 kg)
Remote Infrastructure Management (RIM-600)
System Host Module
14 lb (6.4 kg)
All products quoted are subject toavailability based on manufacturing capacity and shipping dates should be considered estimates only. While
every effort has been made toensure the accuracy of all information, CPI does not accept liability for any errors or omissions and reservesthe
©2009 Chatsworth Products, Inc. All rightsreserved. CPI, CPI Passive Cooling, Saf-T-Grip, Seismic Frame, SlimFrame and MegaFrame are
federally registered trademarks of Chatsworth Products,Inc. Cube-iT Plus, Evolution, OnTrac, QuadraRack, Simply Efficient and TeraFrame are
16147-054
16147-008
60000-001
Not exactly what you need?
For complete information visit
www.chatsworth.com/locks.
right to change information and descriptionsof listed services and products.
trademarks of Chatsworth Products, Inc. Allother trademarks belong to their respective companies. MKT-60020-355Rev.3 01/09