Charnwood SLX20 User Manual

Page 1
CHARNWOOD
SLX20Multi-Fuel
Roomheater
Operating
and
InstallationInstructions
BishopsWay,Newport,IsleofWight,PO305WS,U.K.
Tel:+44(0)1983537799Fax:+44(0)1983537788
Page 2
CHARNWOOD
SLX20
OperatingandInstallation
Instructions
Contents
OperatingInstructions
GeneralPoints...................3
Fuels..........................3
DoorOperation.................4
MultifuelGrate..................4
Lighting........................3
ControllingTheFire..............4
RunningWithTheDoorsOpen.....4
AshClearance...................4
Riddling........................5
Refuelling......................5
OvernightBurning................5
ThroatPlateandFluewayCleaning...5 SpecialPointsWhenBurningCoal...5
CleaningandMaintenance..........5
Throatplate&FluewayCleaning.....5
ChimneySweeping...............6
TroubleShooting.................6
InstallationInstructions
Health&SafetyPrecautions........8
Performance....................8
Chimney.......................8
HeathandFireSurround..........8
PreparationoftheFireplace........8
FittingtheFire...................9
HotWaterSystem...............9
FittingtheOptionalAdd-InBoiler....9
FlueConnections&Infilling........10
Thermostat....................10
PreLightingCheck..............11
Commissioning.................11
OverallDimensions..............11
BishopsWay,Newport,IsleofWight,PO305WS,U.K.
Tel:+44(0)1983537799Fax:+44(0)1983537788
Page 3
OPERATINGINSTRUCTIONSFORTHE
CHARNWOODSLX20
GENERALPOINTS
Beforelightingthefirecheckwiththeinstallerthatthework andchecksdescribedintheinstallationinstructionshave beencarriedoutcorrectlyandthatthechimneyhasbeen swept,issound,andfreeofanyobstructions. WARNINGTheremustnotbeanextractorfanfittedinthe sameroomasthisapplianceasthiscancausetheappliance toemitsmokeandfumesintotheroom. Iftheapplianceisfittedinplaceofanopenfirethenthe chimneyshouldbesweptonemonthaftertheinstallationto clearanysootfallswhichmayhaveoccurredduetothe differenceincombustionbetweentheappliance andthe openfire. Whenusingthefireinsituationswherechildrenorinfirm peoplearepresentpleaseuseafireguardtoprevent accidents.Thefireguardshouldbemanufacturedin accordancewithBS6539.
PETROLEUMCOKEISNOTSUITABLEFORUSEON
THISAPPLIANCE,ITSUSEWILLINVALIDATETHE
GUARANTEE
Atfirstyoumayfindithelpfultotryseveralfuelstofindthe mostsuitable.Ifyouareunabletoobtainthefuelyouwant, askyoursupplieroranapprovedfueldistributortosuggest analternative,orringtheSolidFuelAssociationHelplineon Freephone0800600000.
FUELS
Thefollowingsmokelessfuelsaresuitableforuseonthis appliance:
Ancit(PhurnacitePlus), AnthraciteLargeNuts, Centurion, Cosycoke, Extracite, Maxibrite, Phurnacite, WelshDrySteamCoal(largeNuts)
Theabovefuelsareallsuitableforuseinsmokecontrol areas.Inotherareasthefollowingfuelsmayalsobeburnt:
COAL
HousecoalDoubles,Treblesorcobblesmayallbeburnt.Do notusesingles,smallnuts,orcoaldust.Itisimportantthat thelargesizecoalisused(i.e.Largerthan2”or50mmin size).
Thecoalshouldbedry.Whenburningbituminouscoala littleextracareisneeded.PleaseTakenoteofthesection “SpecialPointsForBurningCoal”
Wood
OnlyDrywellseasonedwoodshouldbeburntonthis applianceasburningwetunseasonedwoodwillgiveriseto heavytardeposits.Forthesamereasonhardwoodisbetter thansoftwood.Burningwetunseasonedwoodwillalso resultinconsiderablyreducedoutputs.Thewoodshouldbe cutandsplitandthenlefttoseasoninawellventilateddry placeforatleastoneyearpreferablytwoyearsBeforeuse.
PEAT
Ensurethatthepeatiswelldriedbeforeuse.Burningwet
peatwillgiverisetoheavytardepositsandreduceoutputs.
Turnhandle clockwisetoopen
ThermostatControlKnob
Thermostatflap(behindsidepanel)
AirwashControl
pulltoopen
Fig.1.Controls
Page3
SLX209.03
Page 4
DOOROPERATION
Thedoorsareopenedbyraisingthedoorhandleasshown inFig.1.Whenthefireisalight,avoidtouchingthedoors otherthanontheknobsasthemetalwillbecomehot. Whenclosingthedoorsdonotuseexcessiveforce.
MULTIFUELGRATE
YourCharnwoodisfittedwithamultifuelgratewhich enablessolidfuel,woodandpeattobeburnedequally effectively.
Thegratehastwopositions.Oneforsolidfuel,theother forwoodandpeat.Wheninthesolidfuelpositionashcan fallthroughthegrateandintotheashpan.Wheninthe woodpositionashisabletobuilduponthegrateasis necessaryforeffectivewoodorpeatburning.Movementof thegratefromonepositiontotheotheriseffectedusing thetoolsupplied.Thegrateisputintothewoodpositionby movingthetoolupuntilthetoolisvertical.Thegrateisput intothesolidfuel positionbymovingthetooldownuntilthe toolishorizontal.
Ifamixtureofwoodandsolidfuel,orpeatandsolidfuel,is tobeburntthenkeepthegrateinthesolidfuelposition.
DoNotGoBeyond 45°Position WhenRiddling
RiddleBetween Horizontal&
45°Positions
ToolToBe Horizontal ForSolidFuel
Tooltobe Vertical ForWood OrPeat
LIGHTING
Placesomepaperanddrykindlingwoodorfirelighterson thegrateandcoverwithasmallamountoffuel.Turnthe thermostatcontrolknobtomaximumsettingandlightthe paperorfirelighters.Closethedoorsandallowthefireto burnuntilthefueliswellignitedthenloadwithmorefuel andadjustthethermostattotherequiredlevel.
Oninitiallighting,thefiremaysmokeandgiveoffanodour asthesiliconpaintwithwhichthefireboxispaintedreacts totheheat.Thisisnormalandwillceaseafterashorttime. Inthemeantimetheroomshouldbewellventilated.
Beforerelightingthefire,riddle,removeanyclinkerfrom thefirebedandemptytheashpan.
CONTROLLINGTHEFIRE
Therateofburningandhencetheoutputiscontrolledby thecontrolknobonthelefthandsideoftheapplianceand theairwashcontrolontheright,showninfig.1.Usethe controlknobonthelefttocontroltheheatoutputfromthe fireandkeeptheairwashcontrolslightlyopenmostofthe timetokeeptheglassclean.Itwillnotbepossibletokeep theglasscleaniftheashwashcontrolisfullyclosed, particularlyafterrefuelling.Thenumberatthetopofthe controlknobisthenumberatwhichitisset,thehigherthe numberthefastertheburningrate.
Fig.2.GrateOperation
RUNNINGTHEFIREWITHTHE
DOORSOPEN
Thefiremayberunwiththedoorsopenifdesiredalthough thiswillresultinareductioninefficiencyandhenceoutput. Themorereactivefuels,likehomefire,willburnbetter whenthedoorsareleftopenthanfuelslikephurnaciteand ancit.
Forsafetyreasons,ifthefireistobeleftunattendedwith thedoorsleftopenthenuseasparkguardwhichcomplies toBS3248.
ASHCLEARANCE
Theashpanshouldbeemptiedregularlybeforeitcomestoo full.Themostconvenienttimetoremovetheashisjust beforeriddlingthefiresincetheashwillbeatit’scoolest. Usetheashpan/riddlingtoolprovidedtoremovethe ashpan,thefoldupcarryinghandleshouldbeheldwitha heatproofglove.
Neverallowtheashtoaccumulateintheashpansothatit comesincontactwiththeundersideofthegrateasthiswill seriouslydamagethegratebars.Ensurethattheairinlet damperisnotpreventedfromclosingbyspillagefuelorash.
Page4
SLX209.03
Careshouldbetakentoensurethattheashiscoolbefore emptyingitintoplasticlinersorbins.
Page 5
Tomakeashremovaleasierthereisaspecial
ashcarrier
supplieror,incaseofdifficulty,fromourselves.
available.Thismaybepurchasedfromyou
Charnwood
RIDDLING
Riddlingtwiceadayisusuallysufficient.
Thefireshouldberiddledwiththedoorsshut.Placethe toolontheknobandrotatebetweenthehorizontalandthe 45°positionseveraltimesasshowninFig.2.
Caution:whenriddlingthegrateusingsolidfueldonotgo beyondthe45°positionasthiscancausethegratetojam.
Ifjammingdoesoccurthenthefireshouldbeallowedto burnforapproximatelyhalfanhourbeforeriddlingthe grateagainasdescribedabove.
Toomuchriddlingcanresultinemptyingunburntfuelinto theashpanandshouldthereforebeavoidedClinkershould regularlyberemovedfromthefirebed.
THROATPLATEANDFLUEWAY
CLEANING
Itisimportantthatthethroatplateandalltheappliance fluewaysarekeptclean.Whenburningsmokelessfuelsthey shouldbecleanedatleastmonthly.Whenburningother fuelstheyshouldbecleanedonceaweek,andmore frequentlyiffoundnecessary.
Thethroatplateandfluewaysmaybecleanedwithalow firestillburning.Usethescrapertooltoscrapeanysooty depositsoffthefrontoftheplateuntiltheydropintothe fire.
Moresootwillbedepositedonthethroatplateandinthe fluewaysiftheapplianceisrunatlowlevelsforlongperiods. Ifthisisthecasethenmorefrequentcleaningwillbe necessary.
SPECIALPOINTSWHENBURNING
COAL
Afterriddling,thegrateshouldbeputbackintothesolid fuelorwoodpositionasrequired(thetoolshouldbe horizontalforsolidfuelorverticalforwood).
REFUELLING
Keepthefireboxwellfilled(thefuelmaybeslopedupfrom thefrontfirebars),butnottoallowthefueltospilloverthe topofthefrontfirebars.Takecare,especiallywhen burningwood,thatthefueldoesnotprojectoverthefront firebarsordamagetotheglassmaybecausedwhenthe doorsareclosed.
OVERNIGHTBURNING
Emptytheashpan,ifnecessary,andthenriddlethefireif youareburningsolidfuel.Ifthefireisverylowthenitmay benecessarytoaddalittlefuelandturnthethermostat controluptomaximumforabriefperioduntilthefireis burningbrightlybeforefillingwithfuel.Whenburning wooduselargelogsovernightastheywillburnmoreslowly thansmallones.
Someexperimentationmaybenecessarytofindthesetting mostsuitablefortheparticularfuelusedandthedrawon thechimney,butgenerallythethermostatshouldbeturned downtotheminimumsetting.
Forovernightburningthefiredoorsmustbeclosed.
Torevivethefire,emptytheashpanifnecessary,riddle (whenburningsolidfuel)andturnthethermostatcontrol tomaximum.Whenthefireisburningwellloadmorefuel asnecessaryandturnthecontrolknobtothedesired setting.
Whenburningwooddonotriddlebutsimplysettheair controlstomaximumuntilthefirepicksupandthenset themattherequiredsettingandrefuelasnecessary.
Whenburninghousecoalkeeptheairwashcontrolatleast sightlyopenallthetime(refertoFig.1.)
Whenloadingtheappliancetakecarenottosmotherthe fire,insteadfillthefireboxintwostageswaitingforthe flamestoappearabovethefire.
Afteraperiodofslumberingalwaysturntheaircontrolup tomaximumandwaituntilflamesappearabovethefuel bedbeforeopeningthedoors.
Burningcoalwillproducemoresootdepositsthanother fuels,especiallyifthefireisrunatlowlevelsforalong periods.Itisthereforevitaltocleanthethroatplate regularly,weeklycleaningis recommended.
CLEANINGANDMAINTENANCE
Cleaning
Theapplianceisfinishedinvitreousenamel.Tocleanthe surfacessimplywipeoverwithadrycloth.Abrasivepads andscouringcleanersmustnotbeusedasthesewill damagethefinish.Careshouldbetakennottoknockthe enamelwithhardobjectsasitwillchip.
CleaningtheGlass
Theglassinthedoorsisaspecialceramicglasswhichisable towithstandhightemperatures.Beforecleaningtheglass openthedoorsandallowthemtocool.Cleantheglass usingadampclothandthenwipingoverwithadrycloth. Anystubborndepositsontheglassmayberemovedwitha proprietarystoveglasscleanerorceramichobcleaner. Somedepositsontheglassmaybeburntoffsimplyby runningthefireatafastrateforafewminutes.Donotuse abrasivecleanersorpadsasthesecanscratchthesurface whichwillweakentheglassandcauseprematurefailure. Aerosolspraycleanersshouldnotbeusednearthe appliancewhilstitisunderfire.
Page5
SLX209.03
Page 6
Whennotinuse
Ifthefireisgoingtobeoutofuseforalongperiod,(for instanceinthesummer,)thentopreventcondensation,and hencecorrosion,thethermostatshouldbeleftatthe maximumsettingandthemaindoorsleftajar.Itisalso advisabletosweepthechimneyandcleanoutthefire. Sprayingtheinsideofthedoorsandfireboxwithalightoil, suchasWD40,willalsohelptokeepallinternalparts workingwell.
DoorSeals
Forthefiretooperatecorrectlyitisimportantthatthe doorsealsareingoodcondition.Checkthattheydonot becomewornorfrayedandreplacethemwhennecessary.
Servicing
Itisrecommendedthat thefireisservicedonceayearto keepitinfirstclassworkingorder.Aftercleaningoutthe fireboxthoroughly,checkthatallinternalpartsareingood workingorder,replacinganypartsthatarebeginningto showsignsofwear.Checkthatthedoorsealsareingood conditionandthatthedoorssealcorrectly.Checkthe operationofthethermostat,bothwhencoldandhot.A servicingguide,TIS48.isavailableonrequest.
CHIMNEYSWEEPING
b)thethermostatknobisturneddowntotheminimum settingandtheairwashisclosed, c)theairinletdamperisclosed(atthebottomleftof the appliance,seeFig.1.)andthatitisnotpreventedfrom closingcompletelybyapieceofash, d)asuitablefuelisbeingused, e)thedoorsealsareingoodcondition.
Over-Firing
Ifthefireisover-firingitwillcauseprematurefailureofthe internalfireparts.Overfiringisoccurringwhenanyinternal partsofthefirebegintoglowred.Topreventover-firing ensurethat: a)thedoorsealsarekeptingoodcondition,andthatthe doorsaresealingcorrectly, b)thethermostatonthefireisworkingcorrectly, c)asuitablefuelisbeingused.
FumeEmission
WarningNote:Properlyinstalledandoperatedthis appliancewillnotemitfumes.Occasionalfumefromde­ashingandre-fuelingmayoccur.Persistentfumeemission ispotentiallydangerousandmustnotbetolerated.If fumeemissiondoespersistthentakethefollowing immediateactionsshouldbetaken:
Thechimneyshouldbesweptatleasttwiceayear.Inmost installationsitwillbepossibletosweepthechimneythrough theappliance.
Firstremovethefrontfirebarsand thethroatplate.Then sweepthechimneyensuringthatsootisremovedfromall horizontalsurfacesaftersweeping.
Insituationswhereitisnotpossibletosweepthroughthe appliancetheinstallerwillhaveprovidedalternativemeans, suchasasootdoor.Aftersweepingthechimneythe applianceflueoutletandthefluepipeconnectingthe appliancemustbecleanedwithafluebrush.
Aftercleaninganysootfromwithinthefire,replacethe throatplateandthefrontfirebars.
Differenttypesofsweep’sbrushesareavailabletosuit differentflueways.Forstandardbrickchimneysawire centresweep’sbrushfittedwithaguidewheelis recommended.Forprefabricatedinsulatedchimneysthe manufacturersinstructionswithregardtosweepingshould beconsulted.
TROUBLESHOOTING
FireWillNotBurn.
Checkthat: a)theairinletisnotobstructedinanyway, b)chimneysandfluewaysareclear, c)asuitablefuelisbeingused, d)thereisanadequateairsupplyintotheroom, e)anextractorfanisnotfittedinthesameroomasthefire.
FireBlazingOutOfControl.
Checkthat: a)thedoorsaretightlyclosed,
a)Openthedoorsandwindowstoventilatetheroom. b)Letthefireoutandsafelydisposeoffuelfromthe appliance. c)Checkforflueorchimneyblockage,andcleanif required. d)Donotattempttorelightfireuntilcauseoffumehas beenidentified,ifnecessaryseekprofessionaladvise.
Themostcommoncauseoffumeemissionisfluewayor chimneyblockage.Foryouownsafetythesemustbekept clean.
Freezing
Ifaboilerisfitteddonotlightthefireifthereisany possibilitythatanypartsofthesystemmaybefrozen.
Chimneyfires
Ifthechimneyisthoroughlyandregularlyswept,chimney firesshouldnotoccur.However,ifachimneyfiredoes occurthenturnthecontrolknobtotheminimumsetting (seeFig.1),andtightlyclosethedoorsoftheappliance. Thisshouldcausethechimneyfiretogooutinwhichcase thecontrolshouldbekeptattheminimumsettinguntilthe fireintheappliancehasgoneout.Thechimneyand fluewaysshouldthenbecleaned.Ifthechimneyfiredoes notgooutwhentheaboveactionistakenthenthefire brigadeshouldbecalledimmediately.
Afterachimneyfirethechimneyshouldbecarefully examinedforanydamage.Expertadviseshouldbesoughtif necessary.
DoorGlassBacksUp
Differencesinchimneydraughtsmeanthatthebestsetting oftheaircontrolswillvaryfordifferentinstallations.A certainamountofexperimentationmayberequired, howeverthefollowingpointsshouldbenotedandwitha littlecareshouldenabletheglasstobekeptcleaninmost situations: a)Theairwashreliesonasupplyofheatedairtokeepthe
Page6
SLX209.03
Page 7
glassclean,therefore,whenlightingthestoveallowthe firebedtobecomewellestablishedbeforeturningthe thermostatdown.Itmaysometimesbebeneficialtoalso keepthedoorsslightlyajarwhilstthefirebecomes established.Thiscanalsoapplywhenre-fuelling. b)Whenre-fuellingkeepthefuelbackalittlefromthefront firebars,donottrytofittoomuchfuelintothefirebox. c)Nevercompletelyclsetheairwashcontrol-asaguideit shouldbeatleastaquarteropen. d)Wetwoodorlogsoverhangingthefrontfirebarswill causetheglasstoblacken.
Itisalwaysmoredifficultto keeptheglasscleanwhen runningthestoveveryslowlyforlongperiods.
Ifblackeningoftheglassstilloccurscheckthatallflue connectionsarewellsealed.Itisalsoimportantthatthe chimneydrawissufficientandthatitisnotaffectedby down-draught.Whenthechimneyiswarmadraught readingofatleast2.5mm(0.10inches)watergaugeshould beobtained.
Page7
SLX209.03
Page 8
INSTALLATIONINSTRUCTIONSFORTHE
CHARNWOODSLX20
HEALTHANDSAFETY
PRECAUTIONS
WARNINGpleasetakecarewheninstallingtheappliance thattherequirementsoftheHealthandSafetyatWorkAct aremet.
Sometypesoffirecementarecausticandshouldnotbe allowedtocomeintocontactwiththeskin.Incaseof contactwashwithplentyofwater.
Ifthereisapossibilityofdisturbinganyasbestosinthe courseofinstallationthenpleaseuseappropriate equipment.
Theremustnotbeanextractorfaninthesameroomasthe applianceasthiscancausetheappliancetoemitfumesinto theroom.
Theremustbeanadequateairsupplytotheroominwhich theapplianceisinstalledtotallingatleast100squarecm.(16 squareinches)toprovidecombustionair.Thisisparticularly necessaryiftheroomisdoubleglazed.
Inadditiontotheseinstructionstherequirementsof BS:8303andBS:6461Pt1&2;1984mustbefulfilled.Local AuthorityBye-lawsandBuildingRegulationsregardingthe installationofSolidFuelburningappliances,fluesand chimneymustbeobserved.
PERFORMANCE
TheratedoutputfortheSLX20is5.4kW(18500btu/h)to theroom.
checked,itmustbeingoodcondition,freefromcracksand blockages,andshould nothaveaexcessivecrosssectional area(e.g.Greaterthan250mmx250mm).Ifyoufindthat thechimneyisinpoorconditionthenexpertadviceshould besoughtregardingthenecessityofhavingthechimney lined.Ifitfoundnecessarytolinethechimneythenalining suitableforSolidFuelmustbeused.
Ifthereisnoexistingchimneythenaprefabricatedblock chimneyoratwinwalledinsulatedstainlesssteelflueto BS:4543canbeusedeitherinternallyorexternally.These chimneysmustbefittedinaccordancewiththe manufacturersinstructionsandBuildingRegulations.
Singlewall fluepipeissuitableforconnectingtheappliance tothechimneybutisnotsuitableforusingforthecomplete chimney.
Ifitisfoundthereisexcessivedrawinthechimneythena draughtstabilisershouldbefitted.
HEARTHANDFIRE
SURROUND
Theappliancemustbeinstalledonafireproofhearthand mustbesituatedatleast300mm(12inches)fromany combustiblematerial.Thepositioningoftheapplianceand thesizeoftheheartharegovernedbybuildingregulations forClass1appliances.Thesebuildingregulationsstatethat thehearthmustextendinfrontoftheappliancebyatleast 300mm(12inches)andtothesidesbyatleast150mm(6 inches).Ifindoubtastothepositioningoftheappliance expertadviseshouldbesoughteitherfromthesupplieror thelocalbuildinginspector.
Thisistheoutputobtainedburningsmokelessfuelwiththe doorsclosedovera4hourlyre-fuelinginterval.
Thereisanoptionaladd-indomestichotwaterboiler availablewithanoutputof2.0kW(6800btu/h).Ifthisis fittedthentheoutputtotheroomwillbereducedbya correspondingamount.
CHIMNEY
Inorderfortheappliancetoperformsatisfactorilythe chimneyheightmustnotbelessthan4metresmeasured fromtheoutletofthefiretothetopofthechimney.The chimneyshouldpreferablybe175mm(7inches)or200mm (8inches)internaldiameterorsquarewithsidesof175mm or200mminternallyand
150mm(6INCHES)INTERNALDIAMETEROR150x 150MMINTERNALSQUARE.
Ifanexistingchimneyistobeuseditmustbesweptand
MUSTNOTBELESSTHAN
Page8
SLX209.03
Thefireplacemustallowgoodcirculationofairaroundthe appliance,especiallyaboveit,toensurethatmaximumheat istransferredtotheroomandalsotopreventthefireplace overheating.Agapof150mm(6inches)eachsideand 300mm(12inches)abovetheapplianceshouldgive sufficientaircirculation.Ifawoodenmantelpiece,beamor surroundisusedinthefireplaceitshouldbeaminimumof 460mm(18inches),andpreferably600mm(24inches) abovetheappliance.Insomesituationsitmaybenecessary toshieldthebeamormantelpiecetoprotectit.
PREPARATIONOFTHEFIREPLACE
Beforefittingtheapplianceintoanexistingfireplaceremove thefirebackandanyloosein-fillmaterial.
Thesurroundandopeningfortheappliancemustconform withFigs.3.Theflatareaaroundtheopeningmustbea minimumof750mmwideand660mmhigh.Ensurethatthe hearthandthebaseintheopeningareflat,level,andat
Page 9
theopenvent.
Theshadedareaonthefaceof
thesurroundistheminimumflat
arearequired.
750mm
B
A
Dim.A: Max.470mm(181/2") Min.405mm(16")
Dim.B: Max.575mm(222/3") Min.555mm(213/4")
660mm
Fig.3.LimitingDimensionsOf
SurroundAndOpening
rightanglestothesurround.
Makeaholeinthefontofthechimneybreasttogiveaccess forinfillingandfixingthefluepipe.Iftheoptionalboileris tobefitteditwillalsobenecessarytomakeaholeinthe sideofthechimneybreasttogiveaccessforthepipework.
FITTINGTHEFIRE
Insomecasesitmaybenecessarytoplacetheconnecting fluepipeinthechimneybeforefittingthefireintothe fireplace.
Applyfirecementtotherearfaceofthesealingflangeon theappliance.Fittheapplianceintotheopeningensuring thatitiscentralandthatagoodsealismadebetweenthe sealingflangeandthefaceofthe surround.
Ifanindirectcylinderisusedthentheprimarycircuitshould befilledwithasuitableinhibitortopreventthebuildupof scaleandcorrosion.
FITTINGTHE
OPTIONALADD-IN
BOILER
Theboilerreplacestherearfirebrickandisreversibleso thatthe1”B.S.P.maletappingsmaycomeoneithertheleft ortherighthandsideoftheboiler.
Theboilertappingsprotrudefromthesidesoftheappliance anditwillthereforebenecessarytofittheboilerintothe applianceafterpositioningtheapplianceinthefireplaceif thefiresurroundisalreadyfitted.
Beforefittingtheboiler,removethefrontfirebars,theside andbackfireplatesandthefirebricks.Knockouttheknock­outsfortheboilertappingsontheappropriatesideofthe firebox.
Removethebacknutsandfibrewashersfromtheboiler tappingsandfittheboilerintotheappliance.Placethefibre washersoverthetappingsontheoutsideoftheappliance andfitthebacknuts,ensuringthattheboilerisheldtightly againsttherearinsidefaceoftheapplianceandthatthetop edgeoftheboilerislevelorrunsuphilltotheflowtapping.
Whenre-fittingthefirebricks,notethattheshortside firebricksuppliedwiththeboilermustbefittedonthesame sideastheboilertappings.Oneoftheoriginalsidebricksis fittedontheotherside,andtherearbrickisdiscarded.The firebricksareheldinpositionbytheretainingbrackets.
Removeanyexcessfirecementfromaroundthesealing flange. Theapplianceshouldbescrewedtothehearththroughthe holesatthebaseofthesealingflange.
HOTWATERSYSTEM
Theoptionaladd-inboilerwhichmaybefittedinthe appliancehasanoutputsufficientfordomestichotwater heating.Iftheboilerisfittedthentheroomheatingwillbe reduced.
Thehotwatersystemshouldbeagravitycircuitandmust becorrectlyventedasshowninFig.4.
Adoublefeedindirecthotwaterstoragecylinderto BS:1566part1shouldbeusedinmostsituations,unlessthe applianceistobefittedinasoftwater areainwhichcasea directhotwatercylindermaybeusedprovidedthatthe boilerisstainlesssteel.
Allpipeworkintheprimarycircuitmustbe28mmdiameter andtheflowpipemustrisecontinuouslyfromtheboilerto
Page9
SLX209.03
FeedandExpansionTank
Overflow
DrainCockatLowestPoint
Fig.4.TypicalGravityHotWaterSystem
22mmOpenVents
ColdWaterTank
Overflow
DomesticHotWaterDrawOff
DrainCock
IndirectHotWaterCylinder
Page 10
Replacethebackfireplate,thesidefireplates,thefront firebarandthethroatplate.
Flaunching
Connecttheboilertotheheatingsystemensuringthatthe flowpiperisesfromtheboiler.Fillthesystemwithwater andcheckforleaks.
FLUECONNECTION
ANDINFILLING
Maketheflueconnectionwiththespecial150°elbow,Part No.010/AV12.Pleasenotethatthisitemisordered separatelyfromtheappliance.Thelegsoftheelbowmaybe cutonsitetosuitthechimney.Alsonotethatthelegsofthe elbowaredifferentlengthstoenablesomesituationstobe cateredforbyturningtheelbowaround.
Theendofthefluepipemustlineupwiththecentre-lineof thechimney,andmustalsoextendtothepointwherethe chimneynarrowstoitsfinalsize.Anylargevoidsmustbe filledandflaunchedtothefluepipetoensurethatallsoot depositscanbeclearedwhentheapplianceisswept,andto preventproblemswiththeoperationoftheappliance.
Ensurethatthefluepipeisnotobstructedorrestrictedin anywayandthatalljointsarewellsealed.
Beforeinfillingcoverthefrontoftheappliancetoprotectit. Ensurethatthefluepipeiscentralandthenfillthespace betweenthebodyoftheapplianceandthestructural brickworkwithvermiculite(e.g.Micafilorsimilar)concrete. Ensurethattherearenoairpockets.Therecommended mixissixvolumesofvermiculitetoonevolumeofportland cementthroughlymixedtogether.Enoughwatershouldbe addedsothatnomorethanoneortwodropsofwaterare releasedwhenahandfulofmixtureissqueezed.
TakeFluePipe UpToNarrowest PartOfChimney.
150°Elbow PartNo.010/AV12
150°
Vermiculite Infill
Fig.5.TypicalInstallation
Afterfillingwithvermiculiteflaunchthetopoftheflue connectorpipetothechimneywithlimemortar.Ensure thatthefluepipeiswellsealedtothechimney.
Makegoodhole(s)inthechimneybreastmakingsurethatit iscompletelyairtight.Atypicalinstallationisshowninfig.5.
Inmostinstallationsitwillbepossibletosweepthechimney throughtheappliance.Ifthisisnotpossiblethensome alternativemeans(suchasasootdoor)mustbeprovided.
Thefreeinsetmethodofinstallationmaybeusedinsteadof infilling.Detailsareavailableonrequest.
THERMOSTAT
Beforelightingthefirecheckthecoldsettingdistanceofthe thermostat.
Withthecontrolknobattheminimumsettingtheflap shouldbejustclosedasshowninFig.6.Toadjustthe distanceslackenthelockingnutandadjustasnecessary. Whensetcorrectlyre-tightenthelockingnut.Ensurethat theflapopensandclosesfreelyastheknobisturned.
FlapJustClosedWith KnobSetToMinimum
LockingNut
ThermostatFlap
Fig.6.ThermostatSetting
Page10
SLX209.03
Page 11
ASSEMBLY
Fitthesidepanelsandthehoodontotheappliance. Instructionsforthisareenclosedwiththepanelpack.
Replaceanyinternalpartspreviouslyremoved.
PRELIGHTING
CHECK
Beforeinitiallightingcheckthefollowingpoints:
1.Thebottomgratebarsmustallbefittedandshouldmove freelyandeasilywhentheriddlingmechanismisoperated.
2.Theplatesroundthesidesandbackofthegratemustbe inpositionandsittingcorrectly.
3.Thethroatplatemustbefittedintheroofofthe appliance.
COMMISSIONING
Oncompletionoftheinstallationandafterallowingtimefor thefirecementandmortartodryout,thefireshouldbelit andcheckedtoensurethatthesmokeandfumesaretaken fromtheapplianceupthechimneyandemittedsafely.Also checkalljointsandseals.
Oncompletionoftheinstallationandcommissioningplease leavetheoperatinginstructionswiththecustomerand adviseontheuseoftheappliance.
Knockoutsforoptionalboiler eitherside
150°
547
506
405
265
199
260
147
170
394
156 i/d
84
608
548
SLX20Dimensions
(Alldimensionsareinmm)
Page11
SLX209.03
Loading...