Charnwood Country 8 Mk2, Country 12 Mk2 User Manual

CHARNWOOD
Country 8 MkII and Country 12 MkII
Flat Top, Low Canopy & High Canopy
Multifuel Roomheaters
Operating
and
Installation Instructions
Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
E-Mail: charnwood@ajwells.co.uk
CHARNWOOD
COUNTRY 8 Mk II & COUNTRY 12 Mk II
Operating and
Installation Instructions
Contents
Operating Instructions
Fuels................................................................... 3
Door Operation................................................... 3
Multifuel Grate................................................... 3
Lighting.............................................................. 4
Controlling The Fire........................................... 4
Riddling ............................................................. 4
Refuelling........................................................... 4
Ash Clearance.................................................... 4
Special Points When Burning Coal..................... 4
Special Points When Burning Wood and Peat.... 4
Overnight Burning ............................................. 5
Maintenance....................................................... 5
Throat Plate & Flueway Cleaning....................... 5
Chimney Sweeping............................................. 5
Trouble Shooting................................................ 6
Installation Instructions
Health & Safety Precautions............................... 7
Performance........................................................ 7
Chimney............................................................. 7
Hearth and Fire Surround................................... 7
Hot Water System............................................... 7
Fitting The Optional Add-In Boiler.................... 8
Connections To Flues ......................................... 8
Soot Doors.......................................................... 9
Pre-Lighting Check ............................................ 9
Commissioning................................................... 9
Overall Dimensions Country 8 ........................... 10
Overall Dimensions Country 12 ......................... 11
Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.
Tel: (01983) 537799 Fax: (01983) 537788
E-Mail: charnwood@ajwells.co.uk
OPERATING INSTRUCTIONS FOR THE
CHARNWOOD
COUNTRY 8 MkII & COUNTRY 12 MkII
Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept, is sound and free from any obstructions.
FUELS
The following fuels may be burnt on this stove. Please pay careful attention to the special points made with each type of fuel as they will help you to get the best from your stove. It must be remembered that only smokeless fuels may be burnt in smoke control areas on this stove. If you are not sure whether you are in a smoke control area, then please check with your Local Authority.
Smokeless Fuels
The recommended smokeless fuels which are suitable for use in smoke control areas on this stove are as follows:
Ancit, (Phurnacite Plus) Anthracite Large Nuts, Cosycoke Homefire, Maxibrite, Phurnacite, Sunbrite Doubles, Welsh Dry Steam Coal (Large Nuts).
Coal
Housecoal doubles, trebles or cobbles may all be burnt. Do not use singles, small nuts, or coal dust
It is important that large size coal is used (ie. larger than 2 inch or 50 mm in size). The coal should be dry.
When burning bituminous coal a little extra care is needed. Please take note of the section "Special Points For Burning Coal".
Wood
Only dry well seasoned wood should be burnt on this appliance as burning wet unseasoned wood will give rise to heavy tar deposits in the stove, on the glass and within the chimney. For the same reason hard wood is better than soft wood. Burning wet unseasoned wood will also result in considerably reduced outputs. The wood should be cut and split and then left to season in a well ventilated dry place for at least one year but preferably two years before use.
Peat
Ensure that the peat is well dried before use. Burning wet peat will give rise to heavy tar deposits and reduced outputs.
PETROLEUM COKE IS NOT
SUITABLE FOR USE ON THIS
APPLIANCE. ITS USE WILL
INVALIDATE THE
GUARANTEE.
At first you may find it helpful to try several fuels to find the most suitable. If you are unable to obtain the fuel you want ask your supplier, or an approved fuel distributor to suggest an alternative.
DOOR OPERATION
Use the door opening and ashpan tool to open and close the doors. Turn the right-hand door knob anti-clockwise to open and clockwise to close.(see Fig. 1)
MULTIFUEL GRATE
Your Charnwood stove is fitted with a multifuel grate which enables both solid fuels and wood to be burned equally effectively. The grate has two positions:-
1) In the solid fuel position the grate
Airwash
Control Closed Open
Door handle
To Open
Riddler Lever
Door Airslide
Closed......Open
Door Airslide
Closed......Open
Door Airslide
Open......Closed
Country 8
Door Airslide
Open......Closed
Country 12
Airwash Control Closed Open
Door handle
To Open
Riddler Lever
Fig. 1. Stove Controls
bars are vertical with gaps in between allowing the primary combustion air to come up through the grate and through the fuel bed.
2) In the wood position the grate bars are horizontal, allowing the combustion air to come round the sides of the grate and over the top of it. When in the wood position ash is able to build up on the grate as is necessary for effective wood or peat burning.
Movement of the grate from one position to the other is effected using the tool supplied as shown in Fig. 2. The grate is put into the solid fuel
Page 3
TW16 3/99
position by moving the tool up until the handle is in the 1 o'clock position. The grate is put into the wood position by moving the tool down until the handle is in the 5 o'clock position. To riddle the appliance when burning solid fuels the tool should be moved between the 1 o'clock and 3 o'clock positions several times. When burning wood or peat the ash should be allowed to build up and riddling should only be carried out once or twice a week.
Solid Fuel
Riddle
Wood
Fig. 2. Grate Operation
LIGHTING
The stove may be lit using dry kindling wood and paper or fire lighters. Set the grate into either the wood position or the solid fuel position as required. Place the paper, or fire lighters, and kindling on the grate and cover with approximately 2 inches of fuel. Open the air slides in the doors and open the airwash control fully (see fig. 1). Light the paper or fire lighters. Close the doors until the fuel is well ignited then load with fuel and adjust the air controls to the required setting.
On initial lighting, the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat. This is
normal and will cease after a short time, but meanwhile the room should be kept well ventilated.
At first only light a small fire and burn it slowly for two hours to allow any residual moisture in the bricks to evaporate.
When relighting the stove, riddle (if burning solid fuel), remove any clinker from the firebed and then empty the ashpan.
CONTROLLING THE
FIRE
The rate of burning and hence the output is controlled by the door air slides and the airwash control (see Fig. 1).
The door airslides are used when lighting and requiring rapid heating. They may be left slightly open to help keep the glass clean.
The airwash control is used most of the time to control the burning rate and to keep the glass clean. Fully extended gives full airwash for faster burning and clean glass whereas fully closed gives slow overnight burning. It will not be possible to keep the glass clean if this control is fully closed, particularly after refuelling.
RIDDLING
When burning solid fuels riddling twice a day is usually sufficient. When burning wood or peat, ash should be allowed to build up and generally weekly riddling will be sufficient. The fire should be riddled with the doors shut (see Fig 2.) Place the tool onto the riddling lever and rotate between the 1 o'clock and 3 o'clock positions several times. Too much riddling can result in emptying unburnt fuel into the ashpan and should therefore be avoided. If any clinker forms it should be removed from the firebed. After riddling, the grate should be put back into the solid fuel or wood position as required (the tool should be in the 1 o'clock position for solid fuel or in the 5 o'clock position for wood).
REFUELLING
Keep the firebox well filled but do
not overfill to prevent fuel from spilling over the top of the front fire bars.
Care should be taken especially when burning wood that fuel does not project over the front fire bars or damage to the glass may be caused when the doors are closed, it can also cause the glass to black up .
ASH CLEARANCE
The ashpan should be emptied regularly before it becomes too full. Never allow the ash to accumulate in the ashpan so that it comes in contact with the underside of the grate as this will seriously damage the grate bars. The ashpan is handled using the tool provided. Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins.
To make ash removal easier there is a special Charnwood ash carrier available. This may be purchased from your supplier or, in case of difficulty, from ourselves.
SPECIAL POINTS
WHEN BURNING
COAL
When loading the stove take care not to smother the fire, instead fill the firebox in two stages waiting between each stage for the flames to appear above the fire.
After a period of slumbering always turn the air control up to maximum and wait until flames appear above the fuel bed before opening the doors.
Burning coal will produce more soot deposits than other fuels, especially if the fire is run at low levels for long periods. It is therefore vital to clean the throat plate regularly, weekly cleaning is recommended.
Never fully close the Airwash control when burning coal.
SPECIAL POINTS
WHEN BURNING
WOOD AND PEAT
The grate should be kept in the wood burning position and should not be riddled until the ash becomes so deep
Page 4
TW16 3/99
Loading...
+ 7 hidden pages